Full configuration interaction simulations of exchange coupled donors in silicon in an effective mass theory framework.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
We use microwave observations from the South Pole Telescope (SPT) to examine the Sunyaev-Zel'dovich effect (SZE) signatures of a sample of 46 X-ray selected groups and clusters drawn from similar to 6 deg(2) of the XMM-Newton Blanco Cosmology Survey. These systems extend to redshift z = 1.02 and probe the SZE signal to the lowest X-ray luminosities (>= 10(42) erg s(-1)) yet; these sample characteristics make this analysis complementary to previous studies. We develop an analysis tool, using X-ray luminosity as a mass proxy, to extract selection-bias-corrected constraints on the SZE significance and Y-500 mass relations. The former is in good agreement with an extrapolation of the relation obtained from high-mass clusters. However, the latter, at low masses, while in good agreement with the extrapolation from the high-mass SPT clusters, is in tension at 2.8 sigma with the Planck constraints, indicating the low-mass systems exhibit lower SZE signatures in the SPT data. We also present an analysis of potential sources of contamination. For the radio galaxy point source population, we find 18 of our systems have 843 MHz Sydney University Molonglo Sky Survey sources within 2 arcmin of the X-ray centre, and three of these are also detected at significance >4 by SPT. Of these three, two are associated with the group brightest cluster galaxies, and the third is likely an unassociated quasar candidate. We examine the impact of these point sources on our SZE scaling relation analyses and find no evidence of biases. We also examine the impact of dusty galaxies using constraints from the 220 GHz data. The stacked sample provides 2.8 sigma significant evidence of dusty galaxy flux, which would correspond to an average underestimate of the SPT Y-500 signal that is (17 +/- 9) per cent in this sample of low-mass systems. Finally, we explore the impact of future data from SPTpol and XMM-XXL, showing that it will lead to a factor of 4 to 5 tighter constraints on these SZE mass-observable relations.
Highlights: • We present model for anisotropic compact star under general relativity. • Here a 4-dimensional spacetime is embedded into the 5-dimensional flat metric. • The spherically symmetric metric has class 1 under which solution set is obtained. • Interesting and physically viable results are found out. • Investigations on the physical features of the model are performed. - Abstract: We present model for anisotropic compact star under the general theory of relativity of Einstein. In the study a 4-dimensional spacetime has been considered which is embedded into the 5-dimensional flat metric so that the spherically symmetric metric has class 1. A set of solutions for the field equations are found depending on the index n involved in the physical parameters. The interior solutions have been matched smoothly at the boundary of the spherical distribution to the exterior Schwarzschild solution which necessarily provides values of the unknown constants. We have chosen the values of n as n=2 and n=10 to 20000 for which interesting and physically viable results can be found out. The investigations on the physical features of the model include several astrophysical issues, like (i) regularity behaviour of stars at the centre, (ii) well behaved condition for velocity of sound, (iii) energy conditions, (iv) stability of the system via the following three techniques — adiabatic index, Herrera cracking concept and TOV equation, (v) total mass, effective mass and compactification factor and (vi) surface redshift. Specific numerical values of the compact star candidates LMC X-4 and SMC X-1 are calculated for central and surface densities as well as central pressure to compare the model value with actual observational data.
Based on the isospin-dependent Boltzmann-Uehling-Uhlenbeck transport model and the scaling model according to nucleon effective mass, effects of elastic and inelastic NN scattering cross sections on {pi}{sup -}/{pi}{sup +} in the neutron-rich reaction of {sup 48}Ca+{sup 48}Ca at a beam energy of 400 MeV/nucleon are studied. It is found that cross-section effects of both NN elastic and inelastic scatterings affect {Delta}{sub 1232}, {pi}{sup -} and {pi}{sup +} production, as well as the value of {pi}{sup -}/{pi}{sup +}.
We have proposed a novel concept of Resonance Ionization Mass Spectrometry using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS). Isotope ratio analysis using ICP-RIMS is expected to be a convenient and precise technique with high throughput. However, the mass discrimination effect caused from difference in kinetic energy of neutral atoms in ICP-RIMS is crucial for precise isotope analysis. We, therefore, investigated the atom kinetic energy distribution introduced into the laser ionization region. The mass-dependent kinetic energy was confirmed in the initial kinetic energy distributions. We preliminary estimated a mass discrimination effect caused by mass-dependent kinetic energy in ICP-RIMS for various detector sizes. We proposed that this effect can be suppressed by selecting the appropriate detector size and adopting the scanning mode of the deflecting voltage.
A novel technique is developed to cancel the effect of environmental parameters, e.g., temperature and humidity, in resonant mass sensing. Utilizing a single resonator, the environmental cancellation is achieved by monitoring a pair of resonant overtones and the effective sensed mass in those overtones. As an eminent advantage, especially compared to dual-mode temperature compensation techniques, the presented technique eliminates any need for previously measured look-up tables or fitting the measurement data. We show that a resonant cantilever beam is an appropriate platform for applying this technique, and derive an analytical expression to relate the actual and effective sensed masses on a cantilever beam. Thereby, it is shown that in applying the presented technique successfully, the effective sensed masses must not be the same in the investigated pair of resonance overtones. To prove the feasibility of the proposed technique, flexural resonance frequencies of a silicon cantilever are measured before and after loading with a strip of photoresist. Applying the presented technique shows significant reductions in influence of environmental parameters, with the temperature and humidity coefficients of frequency being improved from -19.5 to 0.2 ppm deg. C{sup -1} and from 0.7 to -0.03 ppm %RH{sup -1}, respectively.
The anisotropic effective electron masses in wurtzite GaN are determined by generalized infrared spectroscopic ellipsometry. Nonpolar (112{sup ¯}0) oriented thin films allow accessing both effective masses, m{sub ⊥}{sup *} and m{sub ∥}{sup *}, by determining the screened plasma frequencies. A n-type doping range up to 1.7 × 10{sup 20} cm{sup −3} is investigated. The effective mass ratio m{sub ⊥}{sup *}/m{sub ∥}{sup *} is obtained with highest accuracy and is found to be 1.11 independent on electron concentration up to 1.2 × 10{sup 20} cm{sup −3}. For higher electron concentrations, the conduction band non-parabolicity is mirrored in changes. Absolute values for effective electron masses depend on additional input of carrier concentrations determined by Hall effect measurements. We obtain m{sub ⊥}{sup *}=(0.239±0.004)m{sub 0} and m{sub ∥}{sup *}=(0.216±0.003)m{sub 0} for the parabolic range of the GaN conduction band. Our data are indication of a parabolic GaN conduction band up to an energy of approximately 400 meV above the conduction band minimum.
Explore the source record for details and available documents.
Assuming a schematic form of the nucleon effective mass as a function of nuclear excitation energy and mass, we provide a simple explanation for understanding the experimentally observed mass dependence of the nuclear caloric curve. It is observed that the excitation energy at which the caloric curve enters into a plateau region could be sensitive to the nuclear mass evolution of the effective nucleon mass.
Mass injection effect on compressible three- dimensional laminar boundary layers analyzed for nonreacting gas, using conservation equations for flow velocity profiles
I observe a modification to the original Fast Multipole Method (FMM) of Greengard & Rokhlin that approximates the gravitation field of an FMM cell as a small uniform grid (a “gridlet”) of effective masses. The effective masses on a gridlet are set from the requirement that the multipole moments of the FMM cells are reproduced exactly, thus preserving the accuracy of the gravitational field representation. The measurement of the gravitational field from a multipole expansion can then be computed for all multipole orders simultaneously, with a single Fast Fourier Transform, significantly reducing the computational cost at a given value of the required accuracy. The described approach belongs to the class of “kernel independent” variants of the FMM method and works with any Green function.
Conduction and rectification in nanoantenna-coupled NbO{sub x}- and NiO-based metal-insulator-metal (MIM) diodes (“nanorectennas”) are studied by comparing new theoretical predictions with the measured response of nanorectenna arrays. A new quantum mechanical model is reported and agrees with measurements of current–voltage (I–V) curves, over 10 orders of magnitude in current density, from [NbO{sub x}(native)-Nb{sub 2}O{sub 5}]- and NiO-based samples with oxide thicknesses in the range of 5–36 nm. The model, which introduces new physics and features, including temperature, electron effective mass, and image potential effects using the pseudobarrier technique, improves upon widely used earlier models, calculates the MIM diode's I–V curve, and predicts quantitatively the rectification responsivity of high frequency voltages generated in a coupled nanoantenna array by visible/near-infrared light. The model applies both at the higher frequencies, when high-energy photons are incident, and at lower frequencies, when the formula for classical rectification, involving derivatives of the I–V curve, may be used. The rectified low-frequency direct current is well-predicted in this work's model, but not by fitting the experimentally measured I–V curve with a polynomial or by using the older Simmons model (as shown herein). By fitting the measured I–V curves with our model, the barrier heights in Nb-(NbO{sub x}(native)-Nb{sub 2}O{sub 5})-Pt and Ni-NiO-Ti/Ag diodes are found to be 0.41/0.77 and 0.38/0.39 eV, respectively, similar to literature reports, but with effective mass much lower than the free space value. The NbO{sub x} (native)-Nb{sub 2}O{sub 5} dielectric properties improve, and the effective Pt-Nb{sub 2}O{sub 5} barrier height increases as the oxide thickness increases. An observation of direct current of ∼4 nA for normally incident, focused 514 nm continuous wave laser beams are reported, similar in magnitude to recent reports. This measured direct current is compared to the prediction for rectified direct current, given by the rectification responsivity, calculated from the I–V curve times input power.
Thermally grown SiO{sub 2} layers were treated by a plasma nitridation process realized in a vertical furnace. The combination of a pulsed-low frequency plasma and a microwave remote plasma with N{sub 2}/NH{sub 3}/He feed gas mixture was used to nitride the thermally grown SiO{sub 2} gate dielectrics of MIS structures. Temperature dependency of effective masses and the barrier heights for electrons in pure thermally grown SiO{sub 2} as well as plasma nitrided SiO{sub 2} in high electric field by means of Fowler-Nordheim regime was determined. It is frequently seen from the literature that either effective electron mass or barrier height (generally effective electron mass) is assumed to be a constant and, as a result, the second parameter is calculated under the chosen assumption. However, in contrast to general attitude of previous studies, this work does not make any such assumptions for the calculation of neither of these two important parameters of an oxide at temperature ranges from 23 to 110 deg. C for SiO{sub 2}, and 23 to 130 deg. C for nitrided oxide. It is also shown here that both parameters are affected from the temperature changes; respectively, the barrier height decreases while the effective mass increases as a result of elevated temperature in both pure SiO{sub 2} and plasma nitrided SiO{sub 2}. Therefore, one parameter could be miscalculated if the other parameter, i.e., effective mass of electron, was assumed to be a constant with respect to variable physical conditions like changing temperature. Additionally, the barrier heights were calculated just by taking constant effective masses for both types of oxides to be able to compare our results to common literature values.
Effects of altered load on testosterone levels and testicular mass in mammals are not well defined. Two separate studies (loading;centrifuged; +2G(sub z) and unloading;hindlimb suspension;HLS) were conducted to provide a better understanding of the effects of mass loading on testosterone levels and testicular mass. Daily urine samples were collected, and testicular mass measured at the end of the study. +2G(sub z): Sprague-Dawley rats (230-250 g) were centrifuged for 12 days at +2G(sub z): 8 centrifuged (EC) and 8 off centrifuge controls (OCC). EC had lower body mass, however relative testicular mass was greater. EC exhibited an increase in excreted testosterone levels between days 2 (T2) and 6 (T6), and returned to baseline at T9. HLS: To assess the effects of unloading Sprague-Dawley rats (125-150 g) were studied for 12 days: 10 suspended (Exp) and 10 ambulatory (Ctl). Exp had lower body mass during the study, with reduced absolute and relative testicular mass. Exp demonstrated lower excreted testosterone levels from T5-T12. Conclusions: Loading appears to stimulate anabolism, as opposed to unloading, as indicated by greater relative testicular mass and excreted testosterone levels. Reported changes in muscle mass during loading and unloading coincide with similar changes in excreted testosterone levels.
Effect of chemical properties of pyrolysis gases on heat shield mass required for lifting reentry vehicle in typical reentry trajectory