Cladding for transverse-pumped solid-state laser

In a transverse pumped, solid state laser, a nonabsorptive cladding surrounds a gain medium. A single tranverse mode, namely the Transverse Electromagnetic (TEM) sub 00 mode, is provided. The TEM sub 00 model has a cross sectional diameter greater than a transverse dimension of the gain medium but less than a transverse dimension of the cladding. The required size of the gain medium is minimized while a threshold for laser output is lowered.

Byer, Robert L.↗

Theory for anomalous terahertz emission in striped cuprate superconductors

Recent experiments in the doped cuprates La 2−𝑥 ⁢Ba 𝑥⁢ CuO 4 have revealed the emission of anomalous terahertz radiation after impulsive optical excitation. Here, we theoretically investigate the nonlinear electrodynamics of such striped superconductors and explore the origin of the observed radiation. We argue that photoexcitation is converted into a photocurrent by a second-order optical nonlinearity, which is activated by the breaking of inversion symmetry in certain stripe configurations. We point out the importance of including umklapp photocurrents modulated at the stripe periodicity itself, which impulsively drive surface Josephson plasmons and lead to a resonant structure of outgoing radiation, consistent with the experiments. We speculate on the utility of the proposed mechanism in the context of generating tunable terahertz radiation.

36 MATERIALS SCIENCE↗

Electromagnetic induction imaging with a radio-frequency atomic magnetometer

We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

Compact Receiver Front Ends for Submillimeter-Wave Applications

The current generation of submillimeter-wave instruments is relatively mass and power-hungry. The receiver front ends (RFEs) of a submillimeter instrument form the heart of the instrument, and any mass reduction achieved in this subsystem is propagated through the instrument. In the current implementation, the RFE consists of different blocks for the mixer and LO circuits. The motivation for this work is to reduce the mass of the RFE by integrating the mixer and LO circuits in one waveguide block. The mixer and its associated LO chips will all be packaged in a single waveguide package. This will reduce the mass of the RFE and also provide a number of other advantages. By bringing the mixer and LO circuits close together, losses in the waveguide will be reduced. Moreover, the compact nature of the block will allow for better thermal control of the block, which is important in order to reduce gain fluctuations. A single waveguide block with a 600- GHz RFE functionality (based on a subharmonically pumped Schottky diode pair) has been demonstrated. The block is about 3x3x3 cubic centimeters. The block combines the mixer and multiplier chip in a single package. 3D electromagnetic simulations were carried out to design the waveguide circuit around the mixer and multiplier chip. The circuit is optimized to provide maximum output power and maximum bandwidth. An integrated submillimeter front end featuring a 520-600-GHz sub-harmonic mixer and a 260-300-GHz frequency tripler in a single cavity was tested. Both devices used GaAs MMIC membrane planar Schottky diode technology. The sub-harmonic mixer/tripler circuit has been tested using conventional metal-machined blocks. Measurement results on the metal block give best DSB (double sideband) mixer noise temperature of 2,360 K and conversion losses of 7.7 dB at 520 GHz. The LO input power required to pump the integrated tripler/sub-harmonic mixer is between 30 and 50 mW.

Mehdi, Imran↗

Quantum Theory of Surface Lattice Resonances

The collective interactions of nanoparticles arranged in periodic structures give rise to high‐ in‐plane diffractive modes known as surface lattice resonances. Although these resonances and their broader implications have been extensively studied within the framework of classical electrodynamics and linear response theory, a quantum optical theory capable of describing the dynamics of these structures, especially in the presence of material nonlinearities beyond ad hoc few‐mode approximations, is largely missing. To this end, we consider a lattice of metallic nanoparticles coupled to the electromagnetic field and derive the quantum input–output relations within the electric dipole approximation. As applications, we analyze coupling between the nanoparticle array and external quantum emitters, and show how the formalism extends to molecular optomechanics, where the high ‐factors of SLRs enable coupling to collective vibrational modes. We further consider arrays composed of saturable excitonic emitters, demonstrating how emitter nonlinearities can be used to switch the SLR condition between electronic transitions. Using a perturbative approach that accounts for population dynamics, we show how these effects can be probed in pump–probe experiments and give rise to nonlinear phase‐matching phenomena. Our work provides a microscopic framework for modeling SLRs interacting with quantum emitters without phenomenological descriptions of the electromagnetic environment.

molecular optomechanics↗

Onset of stimulated Raman scattering of a laser in a plasma in the presence of hot drifting electrons

Stimulated Raman scattering of a laser in plasmas with energetic drifting electrons was investigated by analyzing the growth of interacting waves during the Raman scattering process. The Langmuir wave and scattered electromagnetic sideband wave grow initially and are dampened after attaining a maximum level that indicates a periodic exchange of energy between the pump wave and the daughter waves. The presence of energetic drifting electrons in the laser-produced plasma influences the stimulated Raman scattering process. The plasma wave generated by Raman scattering may be influenced by the energetic electrons, which enhance the growth rate of the instability. Our results show that the presence of energetic (hot) drifting electrons in a plasma has an important effect on the evolution of the interacting waves. This phenomenon is modeled via two-dimensional particle-in-cell simulations of the propagation and interaction of the laser under Raman instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

4.5-kW Hall Effect Thruster Evaluated

As part of an Interagency Agreement with the Air Force Research Lab (AFRL), a space simulation test of a Russian SPT 140 Hall Effect Thruster was completed in September 1999 at Vacuum Facility 6 at the NASA Glenn Research Center at Lewis Field. The thruster was subjected to a three-part test sequence that included thrust and performance characterization, electromagnetic interference, and plume contamination. SPT 140 is a 4.5-kW thruster developed under a joint agreement between AFRL, Atlantic Research Corp, and Space Systems/Loral, and was manufactured by the Fakal Experimental Design Bureau of Russia. All objectives were satisfied, and the thruster performed exceptionally well during the 120-hr test program, which comprised 33 engine firings. The Glenn testing provided a critical contribution to the thruster development effort, and the large volume and high pumping speed of this vacuum facility was key to the test s success. The low background pressure (1 10 6 torr) provided a more accurate representation of space vacuum than is possible in most vacuum chambers. The facility had been upgraded recently with new cryogenic pumps and sputter shielding to support the active electric propulsion program at Glenn. The Glenn test team was responsible for all test support equipment, including the thrust stand, power supplies, data acquisition, electromagnetic interference measurement equipment, and the contamination measurement system.

Mason, Lee S.↗

Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid-Metal-Fed Pulsed Plasma Thrusters

A short document proposes liquid-metal-fed pulsed plasma thrusters for small spacecraft. The propellant liquid for such a thruster would be a low-melting-temperature metal that would be stored molten in an unpressurized, heated reservoir and would be pumped to the thruster by a magnetohydrodynamic coupler. The liquid would enter the thruster via a metal tube inside an electrically insulating ceramic tube. A capacitor would be connected between the outlet of the metal tube and the outer electrode of the thruster. The pumping would cause a drop of liquid to form at the outlet, eventually growing large enough to make contact with the outer electrode. Contact would close the circuit through the capacitor, causing the capacitor to discharge through the drop. The capacitor would have been charged with enough energy that the discharge would vaporize, ionize, and electromagnetically accelerate the contents of the metal drop. The resulting plasma would be ejected at a speed of about 50 km/s. The vaporization of the drop would reopen the circuit through the capacitor, enabling recharging of the capacitor. As pumping continued, a new drop would grow and the process would repeat.

Markusic, Thomas↗

Piezohydraulic Pump Development

Reciprocating piston piezohydraulic pumps were developed originally under the Smart Wing Phase II program (Lynch) and later under the CHAP program (CSA, Kinetic Ceramics). These pumps focused on 10 cm scale stack actuators operating below resonance and, more recently, at resonance. A survey of commercially available linear actuators indicates that obtaining power density and specific power greater than electromagnetic linear actuators requires driving the stacks at frequencies greater than 1 KHz at high fields. In the case of 10 cm scale actuators the power supply signal conditioning becomes large and heavy and the soft PZT stack actuators generate a lot of heat due to internal losses. Reciprocation frequencies can be increased and material losses significantly decreased through use of millimeter scale single crystal stack actuators. We are presently targeting the design of pumps that utilize stacks at the 1-10 mm length scale and run at reciprocating frequencies of 20kHz or greater. This offers significant advantages over current approaches including eliminating audible noise and significantly increasing the power density and specific power of the system (including electronics). The pump currently under development will comprise an LC resonant drive of a resonant crystal and head mass operating against a resonant fluid column. Each of these resonant systems are high Q and together should produce a single high Q second order system.

Lynch, Christopher S.↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Magnetic Partitioning Nanofluid for Rare Earth Extraction from Geothermal Fluids

Rare earth metals are critical materials in a wide variety of applications in generating and storing renewable energy and in designing more energy efficient devices. Extracting rare earth metals from geothermal brines is a very challenging problem due to the low concentrations of these elements and engineering challenges with traditional chemical separations methods involving packed sorbent beds or membranes that would impede large volumetric flow rates of geothermal fluids transitioning through the plant. We are demonstrating a simple and highly cost-effective nanofluid-based method for extracting rare earth metals from geothermal brines. Core-shell composite nanoparticles are produced that contain a magnetic iron oxide core surrounded by a shell made of silica or metal-organic framework (MOF) sorbent functionalized with chelating ligands selective for the rare earth elements. By introducing the nanoparticles at low concentration (≈0.05 wt%) into the geothermal brine after it passes through the plant heat exchanger, the brine is exposed to a very high concentration of chelating sites on the nanoparticles without need to pass through a large and costly traditional packed bed or membrane system where pressure drop and parasitic pumping power losses are significant issues. Instead, after a short residence time flowing with the brine, the particles are effectively separated out with an electromagnet and standard extraction methods are then applied to strip the rare earth metals from the nanoparticles, which are then recycled back to the geothermal plant. Recovery efficiency for the rare earths at ppm level has now been measured for both silica and MOF sorbents functionalized with a variety of chelating ligands. A detailed preliminary techno-economic performance analysis of extraction systems using both sorbents showed potential to generate a promising internal rate of return (IRR) up to 20%.

58 GEOSCIENCES↗

Embedded Sensors and Controls to Improve Component Performance and Reliability -- Bench-scale Testbed Design Report

Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings to support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility of coherent X-ray production by X-ray pumping

It is suggested that coherent soft X rays can be produced by inverting the electron population in a suitable target, such as Li, through irradiation with X rays generated by fast electrons traversing an electromagnetic field (as in a storage ring). Conditions to be satisfied by target and radiation parameters are stated, and examples given.

Csonka, P. L.↗

Inelastic tunnel diodes

Power is extracted from plasmons, photons, or other guided electromagnetic waves at infrared to midultraviolet frequencies by inelastic tunneling in metal-insulator-semiconductor-metal diodes. Inelastic tunneling produces power by absorbing plasmons to pump electrons to higher potential. Specifically, an electron from a semiconductor layer absorbs a plasmon and simultaneously tunnels across an insulator into metal layer which is at higher potential. The diode voltage determines the fraction of energy extracted from the plasmons; any excess is lost to heat.

Anderson, L. M.↗