Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Additive Manufacturing of Electronics for Space Applications

Additive manufacturing techniques for electronics will enable new detector and electronic assemblies that were not previously possible with traditional assembly processes. This technology has the potential to reduce mass and volume for fabrication and assembly of detector, instrument, and electronics concepts by printing fine feature sizes, printing on complex geometries, and allowing new concept production. This presentation summarizes efforts developing printing techniques to manufacture detectors and circuitry for two different space applications.

Additive Manufacturing↗

Pioneer Venus Orbiter neutral gas mass spectrometer experiment

The Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) is designed to measure the vertical and horizontal density variations of the major neutral constituents in the upper atmosphere of Venus. The mass spectrometer sensor includes a retarding potential ion source, hyperbolic quadrupole rod analyzer, and electron multiplier detector. The supporting electronic system consists of hybrid integrated circuits to reduce weight and power. The ONMS instrument was launched aboard the Pioneer Venus Orbiter on May 20, 1978, and turned on in orbit around Venus on December 4, 1978. It has operated flawlessly for over a Venus year (243 earth days) and has returned data of the composition of the major constituents in the Venus atmosphere between the altitudes of 150 and 350 km.

Niemann, H. B.↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Electron Velocity Moments in the Solar Wind. I. Calibration of the Wind 3DP EESA Low Detector

Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.

plasmas↗

First Measurement of $𝜈_𝑒$ and $\bar{𝜈}_𝑒$ Charged-Current Single Charged-Pion Production Differential Cross Sections on Argon Using the MicroBooNE Detector

Understanding electron neutrino interactions is crucial for measurements of neutrino oscillations and searches for new physics in neutrino experiments. We present the first measurement of the flux-averaged $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ charged-current single charged-pion production cross section on argon using the MicroBooNE detector and data from the NuMI neutrino beam. The total cross section is measured to be [0.93 ± 0.13⁢(stat) ± 0.27⁢(syst)] × 10 −39 cm 2 /nucleon at a mean $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ energy of 730 MeV. Differential cross sections are also reported in electron energy, electron and pion angles, and electron-pion opening angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multichannel Phase and Power Detector

An electronic signal-processing system determines the phases of input signals arriving in multiple channels, relative to the phase of a reference signal with which the input signals are known to be coherent in both phase and frequency. The system also gives an estimate of the power levels of the input signals. A prototype of the system has four input channels that handle signals at a frequency of 9.5 MHz, but the basic principles of design and operation are extensible to other signal frequencies and greater numbers of channels. The prototype system consists mostly of three parts: An analog-to-digital-converter (ADC) board, which coherently digitizes the input signals in synchronism with the reference signal and performs some simple processing; A digital signal processor (DSP) in the form of a field-programmable gate array (FPGA) board, which performs most of the phase- and power-measurement computations on the digital samples generated by the ADC board; and A carrier board, which allows a personal computer to retrieve the phase and power data. The DSP contains four independent phase-only tracking loops, each of which tracks the phase of one of the preprocessed input signals relative to that of the reference signal (see figure). The phase values computed by these loops are averaged over intervals, the length of which is chosen to obtain output from the DSP at a desired rate. In addition, a simple sum of squares is computed for each channel as an estimate of the power of the signal in that channel. The relative phases and the power level estimates computed by the DSP could be used for diverse purposes in different settings. For example, if the input signals come from different elements of a phased-array antenna, the phases could be used as indications of the direction of arrival of a received signal and/or as feedback for electronic or mechanical beam steering. The power levels could be used as feedback for automatic gain control in preprocessing of incoming signals. For another example, the system could be used to measure the phases and power levels of outputs of multiple power amplifiers to enable adjustment of the amplifiers for optimal power combining.

Li, Samuel↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A Radiation Dosimeter Concept for the Lunar Surface Environment

A novel silicon detector configuration for radiation dose measurements in an environment where solar energetic particles are of most concern is described. The dosimeter would also measure the dose from galactic cosmic rays. In the lunar environment a large range in particle flux and ionization density must be measured and converted to dose equivalent. This could be accomplished with a thick (e.g. 2mm) silicon detector segmented into cubic volume elements "voxels" followed by a second, thin monolithic silicon detector. The electronics needed to implement this detector concept include analog signal processors (ASIC) and a field programmable gate array (FPGA) for data accumulation and conversion to linear energy transfer (LET) spectra and to dose-equivalent (Sievert). Currently available commercial ASIC's and FPGA's are suitable for implementing the analog and digital systems.

Adams, James H.↗

Electron-Photon Coincidence Calibration Of Photon Detectors

Absolute and relative detector efficiencies measured. Apparatus uses coincidence-counting techniques to measure efficiency of ultraviolet or vacuum ultraviolet detector at very low radiation intensity. Crossed electron and atomic beams generate photons used to calibrate photon detector. Pulses from electron counter and photon detector(s) processed by standard coincidence-counting techniques. Used to calibrate other detectors or make absolute measurements of incident photon fluxes.

Srivastava, Santosh K.↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗