Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENERGY CONSUMPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

Experimental driving performance evaluation of battery-powered medium and heavy duty all-electric vehicles

As the push to reduce air pollutants and carbon dioxide for global warming continues, there is increasing interest in the development and deployment of battery electric vehicles for heavy-duty applications as one of the critical and challenging steps of a broader effort to fully electrify the transportation sector. This study evaluated and quantified the energy consumption rates and energy regeneration rates for three heavy-duty battery electric vehicles (a step van, a yard tractor, and a class 8 truck) using driving cycle tests with a heavy-duty vehicle chassis dynamometer. Information in this area is currently very limited, and yet it is critical to understanding how effective heavy-duty battery electric vehicles will be for a wide range of applications as the electrification of the heavy-duty vehicle market continues to expand. Energy consumption rates ranged from 0.37 and 2.71 kWh/km for most vehicle/cycle combinations. On a diesel liter energy-equivalent basis, the heavy-duty vehicles had approximately 3 to 6 times better energy consumption rates compared to comparable diesel vehicles, with weight normalized energy consumption rates also comparing favorably to the current and future greenhouse gas/fuel economy standards for equivalent diesel vehicles. Based on battery capacities ranging from 80 to 215 kWh, the vehicle ranges varied from 38.18 km to 171.2 km, with ranges of 115.9 km to 171.2 km for most types of driving and lower ranges of 38.18 to 42.20 km for sustained grade cycles. Overall, the advantage of improved energy consumption rates coupled with improvements that can be expected for battery technology and vehicle range, provide promise for expanded use of heavy-duty vehicles going into the future.

33 ADVANCED PROPULSION SYSTEMS↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Needs to Support the Reconstruction Strategy of Ukraine

Ukraine has been facing difficult times. Russia started a full-scale invasion on February 24, 2022, and has caused huge human and infrastructure losses. As a result of the invasion, more than 8 million people left their homes. The Russian army has targeted Ukrainian energy sources, destroying or damaging over 50% of thermal power generation capacity (coal and gas), 30% of solar generation, and 90% of wind generation. The Russians are also threatening Ukrainian energy security, as they currently control the Zaporizhzhia nuclear power plant – Europe’s largest. In addition, Russia has destroyed 121,000 buildings, including 5,300 multistory buildings - more buildings than Ukraine built during the past five years. The occupiers destroyed or damaged 343 district heat boiler stations (destroyed 12 / damaged 331) and 8 CHPs (destroyed 4/ damaged 4). There is no doubt that Ukraine will be able to protect its sovereignty and restore its territorial integrity; however, this will be a long process. The Government of Ukraine needs to simultaneously focus on many issues, from waging war to the restoration of electricity, water, and heat supply in the territories close to the front line. In addition to these time-sensitive issues, the government also needs to plan a long term multi-sector strategy for the reconstruction of Ukraine’s economy. Ukraine initiated a broad-based political process for recovery at the International Ukraine Recovery Conference (URC 2022) in Lugano, Switzerland. Prior to URC 2022, Ukraine applied for EU membership on February 28 and was granted the status of candidate country by the European Council on June 23, 2022. More than 40 nations are fully committed to supporting Ukraine throughout its path from early to long-term recovery. In addition, these countries link a successful recovery to Ukraine’s European future (URC, 2022a). The reconstruction process will be long. The government also recognizes that it is not enough to build energy infrastructure back – it should be built back better. The government is committed to building a more sustainable and cleaner energy sector. Energy modeling can provide important insights into paths to decarbonize Ukraine’s economy while rebuilding it after the war. Pacific Northwest National Laboratory (PNNL) and the Institute for Economics and Forecasting of the National Academy of Sciences of Ukraine (IEF) work on modeling decarbonization scenarios in the energy sector of Ukraine. The teams focus on the heat sector, which includes district heat, autonomous and individual heating, and energy consumption by final energy consumption sectors, including buildings. Since the teams use world-class integrated assessment models, other sectors will be analyzed as well. The purpose of the document is to describe the needs of key Ukrainian ministries in modeling the reconstruction process. The scope of this document is limited to modeling energy consumption by the power and heat sectors, final energy consumption by buildings, and GHG emissions from these two sectors. The rest of this policy memo is organized as follows. After this introduction, Chapter 2 discusses key provisions of the reconstruction strategy with a focus on energy, buildings, heat supply, environment, and European integration aspirations. Section 3 provides an overview of recent developments and key decisions of the Government of Ukraine in the area of energy efficiency and decarbonization. Finally, Section 4 provides key suggestions on how PNNL and IEF can help the Government of Ukraine in developing strategic documents.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computer Vision-Enabled Smart Traffic Monitoring for Sustainable Transportation Management

Transportation accounts for a significant portion of total global energy consumption. Excessive energy consumption usually occurs in urban traffic environments with congestion and travel delays. With the advancement of remote sensing and computer vision technologies, real-time traffic conditions can be monitored. Therefore, sustainable transportation management strategies can be developed to optimize the overall energy and environment performance and reduce congestion and emissions. This work presents a smart traffic monitoring system based on remote camera sensors. Real-time and historical traffic conditions at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) were monitored and analyzed to develop optimal transportation management strategies for sustainability. Computer vision algorithms were developed and applied to process the real-time camera data to obtain complete traffic information across the ORNL campus. Weeks of historical data were collected and processed to analyze the traffic and identify bottlenecks. The proposed traffic monitoring and management approach can be applied and extended to benefit other campuses or urban areas.

Shao, Yunli↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗

Eco Look-Ahead Control of Battery Electric Vehicles and Roadway Grade Effects

Roadway grade is one of the major variables that affects a vehicle’s energy consumption. This study demonstrates the potential benefits of an eco look-ahead control for battery electric vehicles (BEVs). The proposed eco look-ahead controller was developed for the lead vehicle of a platoon of BEVs. The eco look-ahead control predicts the optimum speed and acceleration levels within a preset speed window to minimize energy consumption considering the instantaneous energy used and the regenerated energy. The developed BEV eco look-ahead control system integrates a BEV energy consumption model and a powertrain model to save fuel while maintaining vehicle speed within a user-specified window. In addition, the study demonstrates the effects of roadway grade on BEV energy consumption. The results show that the energy consumption of BEVs are significantly reduced on downhill roads compared with internal combustion engine vehicles owing to regenerative braking. Specifically, testing showed that BEVs could even produce extra energy on downhill roads. The study also tested the eco look-ahead control on an 18-km section of I-81 and found that the system produced savings of 8.51% and 26.88% in the uphill and downhill directions, respectively. This study demonstrated that regenerative energy in BEVs is a critical factor in energy efficiency and the developed eco look-ahead control significantly improved the energy efficiency for BEVs.

Engineering↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wattchmen: Watching the Wattchers – High Fidelity, Flexible GPU Energy Modeling

Modern GPU-rich HPC systems are increasingly becoming energy-constrained. Thus, understanding an application’s energy consumption becomes essential. Unfortunately, current GPU energy attribution techniques are either inaccurate, inflexible, or outdated. Therefore, we propose Wattchmen, a flexible methodology for measuring, attributing, and predicting GPU energy consumption. We construct a per-instruction energy model using a diverse set of microbenchmarks to systematically quantify the energy consumption of GPU instructions, enabling finer-grain prediction and energy consumption breakdowns for applications. Compared with the state-of-the-art systems like AccelWattch (32%) and Guser (25%), across 16 popular GPGPU, graph analytics, HPC, and ML workloads, Wattchmen reduces the mean absolute percent error (MAPE) to 14% on V100 GPUs. Furthermore, we show that Wattchmen provides similar MAPEs for water-cooled V100s (15%) and extends to later architectures, including air-cooled A100 (11%) and H100 (12%) GPUs. Finally, to further demonstrate Wattchmen ’s value, we apply it to applications such as Backprop and QMCPACK, where Wattchmen ’s insights enable energy reductions of up to 35%.

Tran, Brandon [University of Wisconsin, Madison] (↗

Simple Diesel Train Fuel Consumption Model for Real-Time Train Applications

This paper introduces a simple diesel train energy consumption model that calculates the instantaneous energy consumption using vehicle operational input variables, including the instantaneous speed, acceleration, and roadway grade, which can be easily obtained from global positioning system (GPS) loggers. The model was tested against real-world data and produced an error of -1.33% for all data and errors ranging from -12.4% to +8.0% for energy consumption of four train datasets amounting to a total of 5854 km trips. The study also validated the proposed model with separate data that were collected between Valencia and Cuenca, Spain, which had a total length of 198 km and found that the model was accurate, yielding a relative error of -1.55% for the total energy consumption. These results show that the proposed model can be used by train operators, transportation planners, policy makers, and environmental engineers to evaluate the energy consumption effects of train operational projects and train simulation within intermodal transportation planning tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of a Mixed Fleet of Aerial Drones for Medical Supplies: A Case Study of Blood Delivery Logistics

Aerial drones have emerged as an innovative solution for faster transportation of time-sensitive items (e.g., emergency medical supplies), potentially reducing the transmission of contagious diseases and enhancing healthcare availability through contactless autonomous delivery. We study fleet sizing and efficient scheduling of a mixed fleet of drones for delivering time-sensitive medical items having distinct release and due times to minimize the required fleet size and fleet composition, the required number of additional batteries, and the total energy consumption. We continuously track the remaining battery energy of drones to determine the optimal timing for battery replacement, rather than replacing the battery at each node. Using actual drone flight test data, we employed a machine learning (ML) method to estimate the energy consumption of different drone types during flight segments for different operating parameters. We present a novel mixed-integer programming model to efficiently formulate the problem that integrates the estimated energy consumption functions from ML. We propose a new greedy heuristic (GH) algorithm and a customized genetic algorithm (GA) for solving large-scale instances of this problem faster. Results demonstrate that the GH algorithm is substantially faster than the accelerated CPLEX and the GA, while sacrificing the solution quality by a small amount. Results based on an actual blood sample delivery case study from Pendleton, Oregon, United States, show that using a mixed fleet of drones reduces the total cost and total energy consumption up to 18.18% and 28.7%, respectively, compared to using a homogeneous fleet.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗