Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENERGY MODELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Sector-Specific Methodologies for Subnational Energy Modeling

The National Renewable Energy Laboratory (NREL) and the Department of Energy's Office Strategic Priorities and Impact Analysis Office sought to address gaps in subnational energy data availability. This report describes the methodologies and analysis developed to estimate electricity and natural gas consumption and expenditures for the residential, commercial, and industrial sectors within each U.S. city.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Constraints on a f(R) gravity dark energy model with early scaling evolution

The modified gravity with f(R) = R{sup 1+ε} (ε > 0) allows a scaling solution where the energy density of gravity sector follows the energy density of the dominant fluid. We present initial conditions of background and perturbation variables during the scaling evolution regime in the modified gravity. As a possible dark energy model we consider a gravity with a form f(R) = R{sup 1+ε}+qR{sup −n} (−1 < n ≤ 0) where the second term drives the late-time acceleration. We show that our f(R) gravity parameters are very sensitive to the baryon perturbation growth and baryon density power spectrum, and present observational constraints on the model parameters. We consider full perturbations of f(R) gravity. Our analysis suggests that only the parameter space extremely close to the ΛCDM model is allowed with ε∼<5 × 10{sup −6} and n∼>−10{sup −4}.

79 ASTRONOMY AND ASTROPHYSICS↗

A Case Study about Energy and Cost Impacts for Different Community Scenarios Using a Community-Scale Building Energy Modeling Tool

The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Lessons Learned in Applying Sensitivity Analysis to Building Stock Energy Models

Uncertainty Analysis (UA) and Sensitivity Analysis (SA) offer essential tools to determine the limits of inference of a model and explore the factors which have the most effect on the model outputs. However, despite a well established body of work applying UA and SA to models of individual buildings, a review of the literature relating to energy models for larger groups of buildings undertaken by Fennell et al. (2019) highlighted very limited application at larger scales. This contribution describes the efforts undertaken by a group of research teams in the context of IEA-EBC Annex 70 working with a diverse set of Building Stock Models (BSMs) to apply global sensitivity analysis methods and compare their results. Since BSMs are a class of model defined by their output and coverage rather than their structure and inputs, they represent a diverse set of modelling approaches. Key challenges for the application of SA are identified and explored, including the influence of model form, input data types and model outputs. This study combines results from 7 different modelling teams, each using different models across a range of urban areas to explore these challenges and begin the process of developing standardised workflows for SA of BSMs.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Dispatchable Renewable Energy Model for Microgrid Power System

Over the years, many research projects have been performed and focused on finding out the effective ways to balance the power demands and supply on the utility grid. The causes of the imbalance could be the increasing demands from the end users, the loss of power generation (generators down), faults on the transmission lines, power tripped due to overload, and weather conditions, etc. An efficient Load Frequency Control (LFC) can assure the desired electricity quality provided to the residential, commercial and industrial end users. A simulation model is built in this project to investigate the contribution of the modeling of dispatchable energy such as solar energy, wind power, hydro power and energy storage to the balance of the microgrid power system. An analysis of simplified feedback control system with proportional, integral, and derivative (PID) controller was performed. The purpose of this research is to investigate a simulation model that achieves certain degree of the resilient control for the microgrid.

14 SOLAR ENERGY↗

Evaluation of “Autotune” calibration against manual calibration of building energy models

Our paper demonstrates the application of Autotune, a methodology aimed at automatically producing calibrated building energy models using measured data, in two case studies. In the first case, a building model is de-tuned by deliberately injecting faults into more than 60 parameters. This model was then calibrated using Autotune and its accuracy with respect to the original model was evaluated in terms of the industry-standard normalized mean bias error and coefficient of variation of root mean squared error metrics set forth in ASHRAE Guideline 14. In addition to whole-building energy consumption, outputs including lighting, plug load profiles, HVAC energy consumption, zone temperatures, and other variables were analyzed. In the second case, Autotune calibration is compared directly to experts’ manual calibration of an emulated-occupancy, full-size residential building with comparable calibration results in much less time. Lastly, our paper concludes with a discussion of the key strengths and weaknesses of auto-calibration approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Energy Modeling Forum (EMF)-30 Study on Short-Lived Climate Forcers: Introduction and Overview

The Energy Modeling Forum (EMF)-30 inter-comparison study on short-lived climate forcers (SLCFs) focuses on black carbon (BC) and methane, two of the most important warming SLCFs. The potential impact on climate change of methane and BC-focused emission reductions in the transport and residential sectors were quantified using nine integrated assessment models and a simple climate model. These SLCF reductions reduced global temperatures by 0.18–0.26 °C in 2050 across the models for central climate parameters, with methane being the dominant contributor. The incremental impact of SLCF-focused reductions is much smaller when combined with a broader climate policy. Individual modeling groups examined the health benefits of air pollutant reductions, climate policy co-benefits, and quantified market impacts from air pollutant damages. Model structure and set-up impact on results are discussed along with areas for future work.

Smith, Steven J.↗

Recovery Act: Development of a Model Energy Conservation Training Program

The overall objective of this project was to develop an updated model Energy Conservation training program for stationary engineers. This revision to the IUOE National Training Fund’s existing Energy Conservation training curriculum is designed to enable stationary engineers to incorporate essential energy management into routine building operation and maintenance tasks. The curriculum uses a blended learning approach that includes classroom, hands-on, computer simulation and web-based training in addition to a portfolio requirement for a workplace-based learning application. The Energy Conservation training program goal is development of a workforce that can maintain new and existing commercial buildings at optimum energy performance levels. The grant start date was July 6, 2010 and the project continued through September 30, 2012, including a three month non-funded extension.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Supermarket Building Energy Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this report presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 60 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 15 ASHRAE climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Sachs-Wolfe effect in interacting dark energy models

Models with dark energy decaying into dark matter have been proposed in cosmology to solve the coincidence problem. We study the effect of such coupling on the cosmic microwave background temperature anisotropies. The interaction changes the rate of evolution of the metric potentials and the growth rate of matter density perturbations and modifies the integrated Sachs-Wolfe component of cosmic microwave background temperature anisotropies, enhancing the effect. Cross correlation of galaxy catalogs with cosmic microwave background maps provides a model-independent test to constrain the interaction. We particularize our analysis for a specific interacting model and show that galaxy catalogs with median redshifts z{sub m}=0.1-0.9 can rule out models with an interaction parameter strength of c{sup 2}{approx_equal}0.1 better than 99.95% confidence level. Values of c{sup 2}{<=}0.01 are compatible with the data and may account for the possible discrepancy between the fraction of dark energy derived from Wilkinson microwave anisotropy probe 3 yr data and the fraction obtained from the integrated Sachs-Wolfe effect. Measuring the fraction of dark energy by these two methods could provide evidence of an interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Primordial neutrinos, cosmological perturbations in interacting dark-energy model: CMB and LSS

We present the cosmological perturbation theory for neutrino-probe interacting dark-energy models and calculate the cosmic microwave background anisotropies and the matter power spectrum. In these models, the evolution of the mass of the neutrinos is determined by the quintessence scalar field, which is responsible for the cosmic acceleration today. We consider several types of scalar field potentials and put constraints on the coupling parameter between neutrinos and dark energy. Assuming the flatness of the universe, the constraint we can derive from the current observation is {Sigma}m{sub {nu}}<0.87 eV at the 95% confidence level for the sum over three species of neutrinos. We also discuss the stability issue of our model and on the impact of the scattering term in the Boltzmann equation from the mass-varying neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Ocean Surface Flux Algorithm Effects on Earth System Model Energy and Water Cycles

Earth system models parameterize ocean surface fluxes of heat, moisture, and momentum with empirical bulk flux algorithms, which introduce biases and uncertainties into simulations. We investigate the atmosphere and ocean model sensitivity to algorithm choice in the Energy Exascale Earth System Model (E3SM). Flux differences between algorithms are larger in atmosphere simulations (where wind speeds can vary) than ocean simulations (where wind speeds are fixed by forcing data). Surface flux changes lead to global scale changes in the energy and water cycles, notably including ocean heat uptake and global mean precipitation rates. Compared to the control algorithm, both COARE and University of Arizona (UA) algorithms reduce global mean precipitation and top of atmosphere radiative biases. Further, UA may slightly reduce biases in ocean meridional heat transport. We speculate that changes seen here, especially in the ocean, could be even larger in coupled simulations.

54 ENVIRONMENTAL SCIENCES↗

Ten questions on urban building energy modeling

Buildings in cities consume up to 70% of all primary energy. To achieve cities’ energy and climate goals, it is necessary to reduce energy use and associated greenhouse gas emissions in buildings through energy conservation and efficiency improvements. Computational tools empowered with rich urban datasets can model performance of buildings at the urban scale to provide quantitative insights for stakeholders and inform their decision making on urban energy planning, as well as building energy retrofits at scale, to achieve efficiency, sustainability, and resilience of urban buildings. Designing and operating urban buildings as a group (from a city block to a district to an entire city) rather than as single individuals requires simulation and optimization to account for interactions among buildings and between buildings and their surrounding urban environment, and for district energy systems serving multiple buildings with diverse thermal loads across space and time. When hundreds or more buildings are involved in typical urban building energy modeling (UBEM) to estimate annual energy demand, evaluate design or retrofit options, and quantify impacts of extreme weather events or climate change, it is crucial to integrate urban datasets and UBEM tools in a seamless automatic workflow with cloud or high-performance computing for users including urban planners, designers and researchers. This paper presents ten questions that highlight significant UBEM research and applications. The proposed answers in this work aim to stimulate discussion and provide insights into the current and future research on UBEM, and more importantly, to inspire new and important questions from young researchers in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CMB and BAO constraints for an induced gravity dark energy model with a quartic potential

We study the predictions for structure formation in an induced gravity dark energy model with a quartic potential. By developing a dedicated Einstein-Boltzmann code, we study self-consistently the dynamics of homogeneous cosmology and of linear perturbations without using any parametrization. By evolving linear perturbations with initial conditions in the radiation era, we accurately recover the quasi-static analytic approximation in the matter dominated era. We use PLANCK 2013 data and a compilation of baryonic acoustic oscillation (BAO) data to constrain the coupling γ to the Ricci curvature and the other cosmological parameters. By connecting the gravitational constant in the Einstein equation to the one measured in a Cavendish-like experiment, we find γ < 0.0012 at 95% CL with PLANCK 2013 and BAO data. This is the tightest cosmological constraint on γ and on the corresponding derived post-Newtonian parameters. Because of a degeneracy between γ and the Hubble constant H{sub 0}, we show how larger values for γ are allowed, but not preferred at a significant statistical level, when local measurements of H{sub 0} are combined in the analysis with PLANCK 2013 data.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON DARK ENERGY MODELS FROM RADIAL BARYON ACOUSTIC SCALE MEASUREMENTS

We use the radial baryon acoustic oscillation (BAO) measurements of Gaztanaga et al. to constrain parameters of dark energy models. These constraints are comparable with constraints from other 'nonradial' BAO data. The radial BAO data are consistent with the time-independent cosmological constant model but do not rule out time-varying dark energy. When we combine radial BAO and the Kowalski et al. Union Type Ia supernova data, we get very tight constraints on dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodal Freight Energy Model for Emerging Freight Technology Analysis

While freight movement represents a small portion of the volume in the transportation sector, they are a critical contributor for energy consumed in that sector. To reduce logistics costs, energy consumption and negative environmental impact, emerging technologies, such as digitalization of logistics and alternative powertrain, have been developed and extended applications in freight. These trends are expected to grow and provide opportunities for greater efficiencies in freight movement and corresponding energy use. Still, the complexity of freight systems present challenges in evaluating these benefits, especially in the multimodal inter-city freight. Addressing the research need, this paper develops a multimodal freight energy modeling framework for the analysis of emerging freight technology scenarios. The framework is a bi-level optimization problem: network cost minimization problem (lower-level) and energy minimization problem (upper-level). The lower-level problem is a mode-path assignment problem in multimodal inter-city freight networks, where commodity-specific congestion effects on trans-shipment links are considered. For this model, an inverse modeling approach is applied to infer parameters of the lower-level model. The upper-level problem is designed to search for an optimal scenario that has the lowest energy consumption among different levels of technology applications. The proposed model is empirically tested to analyze truck load-pooling and multimodal load-pooling scenarios through stand-alone and mixed applications using freight shipments originating from or destined to the Chicago region. This framework can be used to explore the impact of emerging freight technologies on mode-path freight flow and energy consumption in the national multimodal freight network.

ADVANCED PROPULSION SYSTEMS↗