Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Solovay-Kitaev Algorithm and Randomized Compilation Data Availability

This zipped folder contains simulation notebooks, simulated data, and experimental data from the QSCOUT trapped-ion device that were used in the publication "Solovay-Kitaev Algorithm and Randomized Compilation" (https://doi.org/10.1103/ll6m-dbl7). The raw data is in the form of measurement outcomes of simple tomographic quantum circuits that were executed on the QSCOUT device and simulated using JAQALPAQ. These data are used to create plots within the jupyter notebooks that were included in the publication.

Quantum benchmarking↗

Model Based Vision for Aircraft Position Determination

This paper investigates the use of imaging sensors to estimate the position of an aircraft with respect to the runway during landing. Passive vision techniques to estimate aircraft position during landing rely on the known runway model, images acquired by onboard imaging sensor, orientation information provided by the inertial navigation system and the position estimate provided by devices such as the global positioning system. Point features in the runway model are compared with the onboard sensor images of the features and the difference between the two is used to correct the aircraft position and orientation. In this paper the sensitivity of point features is examined as a means of determining the accuracy of such position estimation techniques. Expressions are derived for the sensitivity of image point to errors in the position and orientation of the sensor. Using these, the sensitivity of the image to aircraft position and orientation errors along a typical landing glide path is studied. A least squares technique based on this sensitivity analysis is described for the correction of position and orientation estimates. The final version of the paper will include results from the application of this analysis to real image sequences collected in flight.

Sridhar, Banavar↗

The Effect of Large Angles of Yaw on the Accuracy of Wing-Tip Yawmeters

The present method used by the NACA for the measurement of sideslip angles in flight involves the use of a device called the yawmeter. The operation of this instrument depends on the motion of a free-swinging vane which, mounted ahead of the wing tip, alines itself with the local wind direction. Because of the flow pattern about the airplane, the local wind direction at the yaw vane may be slightly different from the direction of the relative wind and the yaw-vane readings may be in error. This error is corrected by using half the difference between the readings of two vanes, one on each wing, for unyawed flight as a calibration constant. It is possible, however, that, because of the change in location of the vane with respect to the flow pattern at large angles of yaw, the constant obtained for unyawed flight may not apply. The present report covers power-off tests made in the free-flight tunnel to check the validity of this method.

Golden, Jacob↗

Reliable voltage scaled links for compressed data

Systems, apparatuses, and methods for reliably transmitting data over voltage scaled links are disclosed. A computing system includes at least first and second devices connected via a link. In one implementation, if a data block can be compressed to less than or equal to half the original size of the data block, then the data block is compressed and sent on the link in a single clock cycle rather than two clock cycles. If the data block cannot be compressed to half the original size, but if the data block can be compressed enough to include error correction code (ECC) bits without exceeding the original size, then ECC bits are added to the compressed block which is sent on the link at a reduced voltage. The ECC bits help to correct for any errors that are generated as a result of operating the link at the reduced voltage.

42 ENGINEERING↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

Software approach to automatic patching of analog computer

The Automatic Patching Verification program (APV) is described which provides the hybrid computer programmer with a convenient method of performing a static check of the analog portion of his study. The static check insures that the program is patched as specified, and that the computing components being used are operating correctly. The APV language the programmer uses to specify his conditions and interconnections is similar to the FORTRAN language in syntax. The APV control program reads APV source program statements from an assigned input device. Each source program statement is processed immediately after it is read. A statement may select an analog console, set an analog mode, set a potentiometer or DAC, or read from the analog console and perform a test. Statements are read and processed sequentially. If an error condition is detected, an output occurs on an assigned output device. When an end statement is read, the test is terminated.

Source record↗

Unified architecture for quantum lookup tables

Quantum access to arbitrary classical data encoded in unitary black-box oracles underlies interesting data-intensive quantum algorithms, such as machine learning or electronic structure simulation. The feasibility of these applications depends crucially on gate-efficient implementations of these oracles, which are commonly some reversible versions of the Boolean circuit for a classical lookup table. Here, we present a general parametrized architecture for quantum circuits implementing a lookup table that encompasses all prior work in realizing a continuum of optimal trade-offs between qubits, non-Clifford gates, and error resilience, up to logarithmic factors. Our architecture assumes only local 2D connectivity, yet recovers results, with the appropriate parameters, polylogarithmic error scaling. We also identify regimes, such as simultaneous sublinear scaling, in all parameters. These results enable tailoring implementations of the commonly used lookup table primitive to any given quantum device with constrained resources.

quantum circuits↗

Multiple single event upsets in CMOS static rams

The occurrence of multiple upset errors during ground tests can contaminate the data and lead to error cross sections which are too high. In space, multiple errors may produce higher upsets than predicted and if they occur in single words they can defeat error detection and correction hardware. This investigation involves data which were taken during an experimental study of dose imprint effects in static memories. The results show that multiple errors occurred mainly for heavy ions with high linear energy transfers and with the majority of these in the soft upset sections of the dose-imprinted memory samples. The percentages of the total number of errors which were singles, doubles, and triplets, were determined as a function of LET, dose, and soft or hard section of the devices. The experimental observations are compared to the predictions of simple binomial statistics.

Stassinopoulos, E. G.↗

Development of Next Generation Memory Test Experiment for Deployment on a Small Satellite

The original Memory Test Experiment successfully flew on the FASTSAT satellite launched in November 2010. It contained a single Ramtron 512K ferroelectric memory. The memory device went through many thousands of read/write cycles and recorded any errors that were encountered. The original mission length was schedule to last 6 months but was extended to 18 months. New opportunities exist to launch a similar satellite and considerations for a new memory test experiment should be examined. The original experiment had to be designed and integrated in less than two months, so the experiment was a simple design using readily available parts. The follow-on experiment needs to be more sophisticated and encompass more technologies. This paper lays out the considerations for the design and development of this follow-on flight memory experiment. It also details the results from the original Memory Test Experiment that flew on board FASTSAT. Some of the design considerations for the new experiment include the number and type of memory devices to be used, the kinds of tests that will be performed, other data needed to analyze the results, and best use of limited resources on a small satellite. The memory technologies that are considered are FRAM, FLASH, SONOS, Resistive Memory, Phase Change Memory, Nano-wire Memory, Magneto-resistive Memory, Standard DRAM, and Standard SRAM. The kinds of tests that could be performed are read/write operations, non-volatile memory retention, write cycle endurance, power measurements, and testing Error Detection and Correction schemes. Other data that may help analyze the results are GPS location of recorded errors, time stamp of all data recorded, radiation measurements, temperature, and other activities being perform by the satellite. The resources of power, volume, mass, temperature, processing power, and telemetry bandwidth are extremely limited on a small satellite. Design considerations must be made to allow the experiment to not interfere with the satellite s primary mission.

MacLeod, Todd↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Photometric Recalibration of the SDSS Stripe 82 to a Few Millimagnitude Precision with the Stellar Color Regression Method and Gaia EDR3

By combining spectroscopic data from the LAMOST DR7, Sloan Digital Sky Survey (SDSS) DR12, and corrected photometric data from the Gaia EDR3, we apply the stellar color regression (SCR) method to recalibrate the SDSS Stripe 82 standard stars catalog of Ivezic' et al. With a total number of about 30,000 spectroscopically targeted stars, we have mapped out the relatively large and strongly correlated photometric zero-point errors present in the catalog, ~2.5% in the u band and ~1% in the griz bands. Our study also confirms some small but significant magnitude dependence errors in the z band for some charge-coupled devices. Various tests show that we have achieved an internal precision of about 5 mmag in the u band and about 2 mmag in the griz bands, which is about five times better than previous results. We also apply the method to the latest version of the catalog (v4.2), and find modest systematic calibration errors of up to ~1% along the R.A. direction and smaller errors along the decl. direction. The results demonstrate the power of the SCR method when combining spectroscopic data and Gaia photometry in breaking the 1% precision barrier of ground-based photometric surveys. Our work paves the way for the recalibration of the whole SDSS photometric survey and has important implications for the calibration of future surveys. Future implementations and improvements of the SCR method under different situations are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA Tech Briefs, December 2011

Topics covered include: 1) SNE Industrial Fieldbus Interface; 2) Composite Thermal Switch; 3) XMOS XC-2 Development Board for Mechanical Control and Data Collection; 4) Receiver Gain Modulation Circuit; 5) NEXUS Scalable and Distributed Next-Generation Avionics Bus for Space Missions; 6) Digital Interface Board to Control Phase and Amplitude of Four Channels; 7) CoNNeCT Baseband Processor Module; 8) Cryogenic 160-GHz MMIC Heterodyne Receiver Module; 9) Ka-Band, Multi-Gigabit-Per-Second Transceiver; 10) All-Solid-State 2.45-to-2.78-THz Source; 11) Onboard Interferometric SAR Processor for the Ka-Band Radar Interferometer (KaRIn); 12) Space Environments Testbed; 13) High-Performance 3D Articulated Robot Display; 14) Athena; 15) In Situ Surface Characterization; 16) Ndarts; 17) Cryo-Etched Black Silicon for Use as Optical Black; 18) Advanced CO2 Removal and Reduction System; 19) Correcting Thermal Deformations in an Active Composite Reflector; 20) Umbilical Deployment Device; 21) Space Mirror Alignment System; 22) Thermionic Power Cell To Harness Heat Energies for Geothermal Applications; 23) Graph Theory Roots of Spatial Operators for Kinematics and Dynamics; 24) Spacesuit Soft Upper Torso Sizing Systems; 25) Radiation Protection Using Single-Wall Carbon Nanotube Derivatives; 26) PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure; 27) Lidar Luminance Quantizer; 28) Distributed Capacitive Sensor for Sample Mass Measurement; 29) Base Flow Model Validation; 30) Minimum Landing Error Powered-Descent Guidance for Planetary Missions; 31) Framework for Integrating Science Data Processing Algorithms Into Process Control Systems; 32) Time Synchronization and Distribution Mechanisms for Space Networks; 33) Local Estimators for Spacecraft Formation Flying; 34) Software-Defined Radio for Space-to-Space Communications; 35) Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding; and 36) Molecular Adsorber Coating

Source record↗

SPACEFLIGHT ASSOCIATED NEURO-OCULAR SYNDROME (SANS): 2023 CLINICAL UPDATE

INTRODUCTION Spaceflight Associated Neuro-ocular Syndrome (SANS) is a condition unique to long-duration spaceflight, with an unclear pathogenesis and pathophysiology, and no perfect terrestrial analog. Approximately 66% of long duration spaceflight (LDSF) astronauts present with the earliest indication of SANS, which is defined as development of any of the following signs in at least one eye during or immediately following spaceflight: 1) optic disc edema (ODE; represented by an increase of ≥ 20 microns in peripapillary total retinal thickness [ΔTRT]); 2) chorioretinal folds; 3) globe flattening; and 4) excessive shift in refractive error (≥ +0.75D). Each of these signs presents potential risk to a crewmember’s vision and mission effectiveness, with ODE posing the highest risk overall. It is not yet known what severity and/or duration of these signs might lead to acute or permanent impacts to ocular anatomy or visual performance. Brain anatomical changes also occur during long-duration spaceflight and are being monitored in the astronaut population; however, these changes have not yet been associated with functional decrements or with SANS. An update will be provided on the latest SANS clinical analyses, diagnostics, and program initiatives. METHODS Data were obtained from clinical records and SANS subject matter experts (SMEs) to compile a SANS clinical update. Areas of interest include: 1) prevalence of SANS signs, 2) defining clinical thresholds for SANS, and 3) an overview of current and planned SANS clinical efforts. DISCUSSION SANS Sign Prevalence: Analysis at the time of this abstract submission indicates that the approximate prevalence of primary SANS findings in USOS LDSF crewmembers is: 64% for ODE (≥ 20-micron ΔTRT), 15% for chorioretinal folds, 26% for globe flattening, and 14% for hyperopic shifts in refractive error (≥ +0.75D). Clinical Thresholds:  The Earliest Indication of SANS was presented publicly for the first time at the 2020 NASA Human Research Program Investigators’ Workshop. See definition in Introduction section (above).  Clinically Concerning SANS – Development of any of the following signs during or immediately following spaceflight: 1) ODE (≥ 55-micron ΔTRT* and/or Frisèn grade ≥1*), 2) sharp chorioretinal folds in the vicinity of the macula, or 3) moderate globe flattening.  Pathological SANS with an Acute Functional Impact – Development of any of the following signs/symptoms during or immediately following spaceflight: 1) visual field loss (e.g., enlarged blindspot), 2) distorted centralvision, or 3) shift in refractive error beyond power of available correction (e.g., “space anticipation glasses”).  Pathological SANS affecting Long-Term Health – Development of any of the following signs/symptoms during or following spaceflight: 1) permanent visual field loss, 2) reduced retinal nerve fiber layer (RNFL) thickness, 3) permanently distorted central vision, 4) atrophy of retinal pigment epithelium (RPE) or photoreceptors, or 5) choroidal neovascularization. Current & Planned Clinical Efforts (accurate at time of abstract submission): All SANS diagnostic hardware are performing nominally onboard the International Space Station: vision screening, fundoscope, optical coherence tomography (OCT) device, ultrasound, and tonometer. The Goggle-Based Visual Field (GBVF) device is nearing completion of its clinical validation study at Ohio State University and is planned for parabolic flight testing in fiscal year 2023 (FY23); pending positive results, this sequence may pave the way towards an ISS technology demonstration in FY24.

T J Brunstetter↗

Effects of target fragmentation on evaluation of LET spectra from space radiation in low-earth orbit (LEO) environment: impact on SEU predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

STS-51 Shuttle Project↗

Effects of Target Fragmentation on Evaluation of LET Spectra From Space Radiation in Low-Earth Orbit (LEO) Environment: Impact on SEU Predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

Shinn, J. L.↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗

Modeling plasma toroidal flow profile control via NTV torque with n = 2 3D fields in MAST-U

Toroidal modeling utilizing the MARS-Q code shows that large (compared to electromagnetic torque) neoclassical toroidal viscous (NTV) torque can be achieved in the plasma core region in reference MAST(-U) L-mode plasmas, by applying the n=2 (n is the toroidal mode number) 3-D fields generated by the magnetic coils used for controlling the edge localized mode and/or by the error field correction coils. Large NTV torque, occurring at relatively slow plasma flow, in combination with strong variation of the torque amplitude versus the coil phasing of the 3-D coils, offers a tool to control the plasma toroidal rotation profile in spherical tokamaks. To effectively employ the toroidal NTV torque, the potentially fast initial flow needs to first be damped by 3-D fields. In conclusion, MARS-Q quasi-linear initial value simulations demonstrate that this is achievable in MAST-U, within the designed 3-D coil current capability for the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗