Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Error-Correcting Codes for Code-Division Multiplexed TES Detectors

Transition edge sensors (TESs) have proven to be highly sensitive and versatile X-ray spectrometers. Upcoming missions, including Athena X-IFU, will rely on highly multiplexed focal planes where more than 32 TES pixels are read out using a single SQUID amplifier channel. We have implemented an error correction algorithm for code-division multiplexed TES signals that can compensate for potential failures of individual SQUID readout channels and that is both scalable and easily implemented in hardware. We present this algorithm for error correction and show results of laboratory tests to assess algorithm performance at recovering TES channels after a SQUID failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

Chromatic-aberration-corrected diffractive lenses for ultra-broadband focusing

We exploit the inherent dispersion in diffractive optics to demonstrate planar chromatic-aberration-corrected lenses. Specifically, we designed, fabricated and characterized cylindrical diffractive lenses that efficiently focus the entire visible band (450 nm to 700 nm) onto a single line. These devices are essentially pixelated, multi-level microstructures. Experiments confirm an average optical efficiency of 25% for a three-wavelength apochromatic lens whose chromatic focus shift is only 1.3 μm and 25 μm in the lateral and axial directions, respectively. Super-achromatic performance over the continuous visible band is also demonstrated with averaged lateral and axial focus shifts of only 1.65 μm and 73.6 μm, respectively. These lenses are easy to fabricate using single-step grayscale lithography and can be inexpensively replicated. Furthermore, these devices are thin (<3 μm), error tolerant, has low aspect ratio (<1:1) and offer polarization-insensitive focusing, all significant advantages compared to alternatives that rely on metasurfaces. Lastly, our design methodology offers high design flexibility in numerical aperture and focal length, and is readily extended to 2D.

36 MATERIALS SCIENCE↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Extending quantum probabilistic error cancellation by noise scaling

Here, we propose a general framework for quantum error mitigation that combines and generalizes two techniques: probabilistic error cancellation (PEC) and zero-noise extrapolation (ZNE). Similar to PEC, the proposed method represents ideal operations as linear combinations of noisy operations that are implementable on hardware. However, instead of assuming a fixed level of hardware noise, we extend the set of implementable operations by noise scaling. By construction, this method encompasses both PEC and ZNE as particular cases and allows us to investigate a larger set of hybrid techniques. For example, gate extrapolation can be used to implement PEC without requiring knowledge of the device’s noise model, e.g., avoiding gate-set tomography. Alternatively, probabilistic error reduction can be used to estimate expectation values at intermediate virtual noise strengths (below the hardware level), leading to partially mitigated results at a lower sampling cost. Moreover, multiple results obtained with different noise-reduction factors can be further postprocessed with ZNE to better approximate the zero-noise limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the electron temperature and identifying plasma detachment using machine learning and spectroscopy

A machine learning approach has been implemented to measure the electron temperature directly from the emission spectra of a tokamak plasma. This approach utilized a neural network (NN) trained on a dataset of 1865 time slices from operation of the DIII-D tokamak using extreme ultraviolet/vacuum ultraviolet emission spectroscopy matched with high-accuracy divertor Thomson scattering measurements of the electron temperature, T e . This NN is shown to be particularly good at predicting T e at low temperatures (T e < 10 eV) where the NN demonstrated a mean average error of less than 1 eV. Trained to detect plasma detachment in the tokamak divertor, a NN classifier was able to correctly identify detached states (T e < 5 eV) with a 99% accuracy (an F 1 score of 0.96) at an acquisition rate 10× faster than the Thomson scattering measurement. The performance of the model is understood by examining a set of 4800 theoretical spectra generated using collisional radiative modeling that was also used to predict the performance of a low-cost spectrometer viewing nitrogen emission in the visible wavelengths. Furthermore, these results provide a proof-of-principle that low-cost spectrometers leveraged with machine learning can be used to boost the performance of more expensive diagnostics on fusion devices and be used independently as a fast and accurate T e measurement and detachment classifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measured Energy-Dependent Neutron Attenuation Through the Stacked Printed Circuit Boards

Engineers often stack printed circuit boards (PCBs), populated with semiconductor devices, one behind the other in neutron beams to improve the error statistics in radiation-effects tests. As the neutron beam traverses through the boards, the neutron flux is both attenuated and the energy spectrum changes, which may have a significant impact on the results of such tests. In this work, we have developed a technique to measure the energy-dependent neutron attenuation due to the PCBs and to determine the energy-dependent effective cross section of neutron interactions with a single PCB. With this effective cross section, engineers can calculate the change in the neutron energy spectrum and the total neutron attenuation after any number of identical PCBs in the stack. This information will allow test engineers to partially correct inaccuracies in soft error tests.

42 ENGINEERING↗

Performance characteristics of a perforated shadow band under clear sky conditions

A perforated, non-rotating shadow band is described for separating global solar irradiance into its diffuse and direct normal components using a single pyranometer. Whereas shadow bands are normally solid so as to occult the sensor of a pyranometer throughout the day, the proposed band has apertures cut from its circumference to intermittently expose the instrument sensor at preset intervals. Under clear sky conditions the device produces a saw tooth waveform of irradiance data from which it is possible to reconstruct separate global and diffuse curves. The direct normal irradiance may then be calculated giving a complete breakdown of the irradiance curves without need of a second instrument or rotating shadow band. This paper describes the principle of operation of the band and gives a mathematical model of its shading mask based on the results of an optical ray tracing study. An algorithm for processing the data from the perforated band system is described and evaluated. In an extended trial conducted at NREL's Solar Radiation Research Laboratory, the band coupled with a thermally corrected Eppley PSP produced independent curves for diffuse, global and direct normal irradiance with low mean bias errors of 5.6 W/m{sup 2}, 0.3 W/m{sup 2} and -2.6 W/m{sup 2} respectively, relative to collocated reference instruments. Random uncertainties were 9.7 W/m{sup 2} (diffuse), 17.3 W/m{sup 2} (global) and 19.0 W/m{sup 2} (direct). When the data processing algorithm was modified to include the ray trace model of sensor exposure, uncertainties increased only marginally, confirming the effectiveness of the model. Deployment of the perforated band system can potentially increase the accuracy of data from ground stations in predominantly sunny areas where instrumentation is limited to a single pyranometer. (author)

14 SOLAR ENERGY↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Q-BEEP: Quantum Bayesian Error Mitigation Employing Poisson Modeling over the Hamming Spectrum

Quantum computing technology has grown rapidly in recent years, with new technologies being explored, error rates being reduced, and quantum processor’s qubit capacity growing. However, near-term quantum algorithms are still unable to be induced without compounding consequential levels of noise, leading to non-trivial erroneous results. Quantum Error Correction (in-situ error mitigation) and Quantum Error Mitigation (post-induction error mitigation) are promising fields of research within the quantum algorithm scene, aiming to alleviate quantum errors, increasing the overall fidelity and hence the overall quality of circuit induction. Earlier this year, a pioneering work, namely HAMMER, published in ASPLOS-22 demonstrated the existence of a latent structure regarding post-circuit induction errors when mapping to the Hamming spectrum. However, they intuitively assumed that errors occur in local clusters, and that at higher average Hamming distances this structure falls away. In this work, we show that such a correlation structure is not only local but extends certain non-local clustering patterns which can be precisely described by a Poisson distribution model taking the input circuit, the device run time status (i.e., calibration statistics) and qubit topology into consideration. Using this quantum error characterizing model, we developed an iterative algorithm over the generated Bayesian network state-graph for post-induction error mitigation. Thanks to more precise modeling of the error distribution latent structure and the new iterative method, our Q-Beep approach provides state of the art performance and can boost circuit execution fidelity by up to 234.6% on Bernstein-Vazirani circuits and on average 71.0% on QAOA solution quality, using 16 practical IBMQ quantum processors. For other benchmarks such as those in QASMBench, the fidelity improvement is up to 17.8%. Q-Beep is a light-weight post-processing technique that can be performed offline and remotely, making it a useful tool for quantum vendors to integrate and provide more reliable circuit induction results.

Stein, Samuel A.↗

Magellan adaptive optics first-light observations of the exoplanet β PIC b. II. 3–5 μm direct imaging with MagAO+Clio, and the empirical bolometric luminosity of a self-luminous giant planet

Young giant exoplanets are a unique laboratory for understanding cool, low-gravity atmospheres. A quintessential example is the massive extrasolar planet β Pic b, which is 9 AU from and embedded in the debris disk of the young nearby A6V star β Pictoris. We observed the system with first light of the Magellan Adaptive Optics (MagAO) system. In Paper I we presented the first CCD detection of this planet with MagAO+VisAO. Here we present four MagAO+Clio images of β Pic b at 3.1 μm, 3.3 μm, L′, and M{sup ′}, including the first observation in the fundamental CH{sub 4} band. To remove systematic errors from the spectral energy distribution (SED), we re-calibrate the literature photometry and combine it with our own data, for a total of 22 independent measurements at 16 passbands from 0.99 to 4.8 μm. Atmosphere models demonstrate the planet is cloudy but are degenerate in effective temperature and radius. The measured SED now covers >80% of the planet’s energy, so we approach the bolometric luminosity empirically. We calculate the luminosity by extending the measured SED with a blackbody and integrating to find log(L{sub bol}/L{sub ⊙}) = −3.78±0.03. From our bolometric luminosity and an age of 23 ± 3 Myr, hot-start evolutionary tracks give a mass of 12.7 ± 0.3 M{sub Jup}, radius of 1.45 ± 0.02 R{sub Jup}, and T{sub eff} of 1708 ± 23 K (model-dependent errors not included). Our empirically determined luminosity is in agreement with values from atmospheric models (typically −3.8 dex), but brighter than values from the field-dwarf bolometric correction (typically −3.9 dex), illustrating the limitations in comparing young exoplanets to old brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative Electroluminescence Imaging Analysis for Performance Estimation of PID-Influenced PV Modules

An empirical method for estimating relative power losses caused by potential-induced degradation (PID) for p-type solar cells and modules using quantitative electroluminescence (EL) analysis (QELA) is presented. First, EL images are corrected for camera- and perspective distortion. The relative power loss map is then calculated from the logarithmic ratio of two EL images, taken either before and after PID degradation or at different applied currents. Only the cell average of the resulting power loss map is evaluated. The highest power loss across each string is averaged to obtain the overall power loss. Consequently, for modules with three strings, three cells are averaged. The resulting power loss depends on the current applied. The conversion to equivalent irradiance allows for comparison of measured and estimated device performance. The analysis of roughly 2000 EL images and related current-voltage (I-V) curves indicates a good agreement between flash-test-measured and performance estimated using QELA. A relative root mean square error of 1-3% can be achieved.

14 SOLAR ENERGY↗

The limits and challenges of error field correction for ITER

Significant progress has been made in interpreting the effects of non-axisymmetric 'error' fields on a plasma through ideal MHD stability and a dominant 'least stable' ideal mode through which the fields couple to the tearing resonant surface. However, in contrast to expectations from such theories, experiments have found limited success in correcting error fields, with single correction coil arrays giving benefits of between 0% and {approx}50% correction (in terms of improvement to a low density locked mode limit), dependent on the structure of the error and correcting fields. With additional coils up to {approx}70% is possible. It was unclear whether this represented an intrinsic stability or control limit, or higher order toroidal or poloidal harmonic effects. Thus, studies on the DIII-D tokamak explored correction of a proxy error field, using two differently structured coil arrays. This enabled the principles of error correction to be tested at high amplitudes and operational densities, with known pure n=1 fields. Results showed substantial residual effects from the corrected n=1 field, with improvements of only {approx}50% in the low density locked mode limit. This suggests that n=1 error fields must couple to more than one surface in the plasma, and this is conjectured to be through more than one ideal mode, thereby requiring precise correction. For ITER, updated predictions of field error have been obtained and compared with revised scalings for tearing mode thresholds, indicating 50% or better error field correction will be needed. This will likely require more than one well coupled correction coil array and sets a challenge for theory to model the behavior, in order to clarify the plasma response and braking mechanisms, and so the effectiveness of ITER's correction coils and the possible need for support from its edge localized mode control coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital I/Q demodulation for KSTAR ion cyclotron range of frequency system

An ion cyclotron range of frequency system requires rf diagnostics for a rf-plasma coupling or for maintaining a correct operation. A detector based on a digital I/Q demodulation technique collects the rf amplitude and phase at the same time without errors from the I/Q imbalance inherent in an analog counterpart. The theory of such a detector was studied and implemented for the first campaign of the KSTAR tokamak. Experimental results of the rf and other diagnostics are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts ({+-} SD) were 2.3 ({+-} 1.4), 2.2 ({+-} 1.1), 2.7 ({+-} 1.5), and 2.1 ({+-} 1.0) mm whereas intrafraction motion was 1.1 ({+-} 1.2), 1.1 ({+-} 1.1), 0.7 ({+-} 0.9), and 0.7 ({+-} 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum state preparation by adiabatic evolution with custom gates

Quantum state preparation by adiabatic evolution is currently rendered ineffective by the long implementation times of the underlying quantum circuits, comparable to the decoherence time of present and near-term quantum devices. These implementation times can be significantly reduced by realizing these circuits with custom gates. Using classical computing, we model the output of a realistic two-qubit processor implementing the adiabatic evolution of a two-spin system by means of custom gates. This modeled output is then compared with the results of quantum simulations solving the same problem on IBM Quantum (IBMQ) systems. Additionally, when used to emulate the behavior of the IBMQ quantum circuit, our realistic model yields state fidelities ranging from 65% to 85%, similar to the actual performance of a diverse set of IBMQ devices. When we reduced the implementation time by using custom gates, however, the loss of fidelity was reduced by at least a factor of 4, allowing us to accurately extract the energy of the target state. This improvement is enough to render adiabatic evolution useful for quantum state preparation for small systems or as a preconditioner for other state preparation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗