Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Contemplating the plasmalemmal control center model

An abundant epidermal mechanosensory calcium-selective ion channel appears able not only to detect mechanical stimuli such as those that initiate gravitropism but also to detect thermal, electrical, and various chemical stimuli. Because it responds to multimodal input with a second messenger output, this channel system seems likely to be an integrator that can engage in feedbacks with many other systems of the cell--and feedback is the hallmark of regulation. In general, the mechanical tension required for channel activation is likely transmitted from the relatively rigid cell wall to the plasma membrane system via linkage or adhesion sites that display antigenicities recognized by antibodies to animal beta-1 integrin, vitronectin, and fibronectin and which have mechanical connections to the cytoskeleton. Thus, functionally, leverage exerted against any given adhesion site will tend to control channels within a surrounding domain. Reactions initiated by passage of calcium ions through the channels could presumably be more effectively regulated if channels within the domains were somewhat clustered and if appropriate receptors, kinases, porters, pumps, and some key cytoskeletal anchoring sites were in turn clustered about them. Accumulating evidence suggests not only that activity of clusters of channels may contribute to control of cytoskeletal architecture and of regulatory protein function within their domain, but also that both a variety of regulatory proteins and components of the cortical cytoskeleton may contribute to control of channel activity. The emerging capabilities of electronic optical microscopy are well suited for resolving the spatial distributions of many of these cytoskeletal and regulatory molecules in living cells, and for following some of their behaviors as channels are stimulated to open and cytosolic calcium builds in their vicinity. Such microscopy, coupled with biochemical and physiological probing, should help to establish the nature of the feedback loops putatively controlled by the linkage sites and their channel domains.

Review↗

Applicability of Electrical and Electroanalytical Techniques to Detect Water and Characterize the Geochemistry of Undisturbed Planetary Soils

The search for life is a primary goal of NASA s planetary exploration program. The search is, of necessity, tiered in both the detection approach (looking for evidence of microbial fossils or the presence of water in the geological history of a planetary body and/or looking for evidence of water, energy sources, precursors to life, signatures of life and/or life itself in the present day planetary environment) and in the survey method (scale, range, specificity) employed. Terrestrial investigations suggests that life as we know it requires water. Thus, the search for extant microbial life and habitats requires identifying water-bearing soils. Determining Reduction-Oxidation (REDOX) couples present in water, once it is found, provides information on soil geochemistry and identifies potential chemical energy sources for life. Mars offers a near-term target for conducting this search. The identification of gully formation [1], layered deposits [2] and elemental ratios of bromine and chlorine [3] present indirect evidence that water was abundant locally in the Martian past. Additionally, Viking images of polar ice and frost formation on the surface of Mars demonstrate that water can exist in at least some near-surface regions of present-day Mars. Atmospheric pressure data further suggest that liquid water may be stable for short periods of time in the mid-latitudes of the Martian surface. [4] Measurements of the global distribution of hydrogen in the Martian regolith offer tantalizing indirect evidence that water may at least exist in near-surface soils. [5] Evidently, any water to be found is likely to exist as soil mixtures at levels ranging between approx.0.5% and approx.5 %.

Seshadri, S.↗

Advanced Failure Determination Measurement Techniques Used in Thermal Fatigue Life Testing of Electronic Packaging

Thermal fatigue life testing of various electronic packaging technologies is being performed by the Reliability Technology Group at the Jet Propulsion Laboratory. These testing efforts are in progress to improve uderstanding of the reliability issues associated with low volume packaging technologies for space applications and to develop qualification and acceptance approaches for these technologies. The work described here outlines the electrical failure detection techniques used during testing by documenting the circuits and components used to make these measurements, the sensitivity of the measurements, and the applicability of each specific measurement.

fatigue surface mount measurement testing thermal ↗

Neuro-Prosthetic Implants With Adjustable Electrode Arrays

Brushlike arrays of electrodes packaged with application-specific integrated circuits (ASICs) are undergoing development for use as electronic implants especially as neuro-prosthetic devices that might be implanted in brains to detect weak electrical signals generated by neurons. These implants partly resemble the ones reported in Integrated Electrode Arrays for Neuro-Prosthetic Implants (NPO-21198), NASA Tech Briefs, Vol. 27, No. 2 (February 2003), page 48. The basic idea underlying both the present and previously reported implants is that the electrodes would pick up signals from neurons and the ASICs would amplify and otherwise preprocess the signals for monitoring by external equipment. The figure presents a simplified and partly schematic view of an implant according to the present concept. Whereas the electrodes in an implant according to the previously reported concept would be microscopic wires, the electrodes according to the present concept are in the form of microscopic needles. An even more important difference would be that, unlike the previously reported concept, the present concept calls for the inclusion of microelectromechanical actuators for adjusting the depth of penetration of the electrodes into brain tissue. The prototype implant now under construction includes an array of 100 electrodes and corresponding array of electrode contact pads formed on opposite faces of a plate fabricated by techniques that are established in the art of microelectromechanical systems (MEMS). A mixed-signal ASIC under construction at the time of reporting the information for this article will include 100 analog amplifier channels (one amplifier per electrode). On one face of the mixed-signal ASIC there will be a solder-bump/micro-pad array that will have the same pitch as that of the electrode array, and that will be used to make the electrical and mechanical connections between the electrode array and the ASIC. Once the electrode array and the ASIC are soldered together, the remaining empty space between them will be filled with a biocompatible epoxy, the remaining exposed portions of the ASIC will be covered with micromachined plates for protection against corrosive bodily fluids, and then the ASIC and its covering micromachined plates will be coated with parylene

Whitacre, Jay↗

MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

Lakew, B.↗

Ozone Production by Corona Discharges During a Convective Event in DISCOVER-AQ Houston

An ozonesonde launched near electrically active convection in Houston, TX on 5 September 2013 during the NASA DISCOVER-AQ project measured a large enhancement of ozone throughout the troposphere. A separate ozonesonde was launched from Smith Point, TX (approx. 58 km southeast of the Houston site) at approximately the same time as the launch from Houston and did not measure that enhancement. Furthermore, ozone profiles for the descent of both sondes agreed well with the ascending Smith Point profile, suggesting a highly localized event in both space and time in which an anomalously large enhancement of 70 - 100 ppbv appeared in the ascending Houston ozonesonde data. Compared to literature values, such an enhancement appears to be the largest observed to date. Potential sources of the localized ozone enhancement such as entrainment of urban or biomass burning emissions, downward transport from the stratosphere, photochemical production from lightning NO(sub x), and direct ozone production from corona discharges were investigated using model simulations. We conclude that the most likely explanation for the large ozone enhancement is direct ozone production by corona discharges. Integrating the enhancement seen in the Houston ozone profile and using the number of electrical discharges detected by the NLDN (or HLMA), we estimate a production of 2.48 x 10(exp. 28) molecules of ozone per flash which falls within the range of previously recorded values (9.89 x 10(exp. 26) - 9.82 x 10)exp. 28) molecules of ozone per flash). Since there is currently no parameterization for the direct production of ozone from corona discharges we propose the implementation of an equation into a chemical transport model. Ultimately, additional work is needed to further understand the occurrence and impact of corona discharges on tropospheric chemistry on short and long timescales.

ozone↗

Overview of Developments in Voluntary Consensus Standards for Counterfeit Parts Avoidance

The presentation provides an introduction to the electronic parts supply chain and various standards used for preventing counterfeit parts. The presentation provides detailed instruction on various non-destructive techniques, destructive and analytical steps for inspecting suspect counterfeit parts. The techniques are based on the AS6171 Aerospace Standard which standardizes the test and inspection procedures, workmanship criteria, and minimum training and certification requirements to detect counterfeit electrical, electronic, and electromechanical parts. Also included are discussions of other inspection, sampling and distribution standards.

Sood, Bhanu↗

Modeling Data Flows with Network Calculus in Cyber-Physical Systems: Enabling Feature Analysis for Anomaly Detection Applications

The electric grid is becoming increasingly cyber-physical with the addition of smart technologies, new communication interfaces, and automated grid-support functions. Because of this, it is no longer sufficient to only study the physical system dynamics, but the cyber system must also be monitored as well to examine cyber-physical interactions and effects on the overall system. To address this gap for both operational and security needs, cyber-physical situational awareness is needed to monitor the system to detect any faults or malicious activity. Techniques and models to understand the physical system (the power system operation) exist, but methods to study the cyber system are needed, which can assist in understanding how the network traffic and changes to network conditions affect applications such as data analysis, intrusion detection systems (IDS), and anomaly detection. In this paper, we examine and develop models of data flows in communication networks of cyber-physical systems (CPSs) and explore how network calculus can be utilized to develop those models for CPSs, with a focus on anomaly and intrusion detection. This provides a foundation for methods to examine how changes to behavior in the CPS can be modeled and for investigating cyber effects in CPSs in anomaly detection applications.

97 MATHEMATICS AND COMPUTING↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Storm severity detection (RF)

Atmospheric electrical emissions occurring in association with Hurricane Alicia were observed by two crossed baseline phase linear interferometers. The sensors were located in San Antonio, Texas, and at Marshall Space Flight Center (MSFC), Huntsville, Alabama. An analysis of the data has indicated that the direction finding (DF) performance of the San Antonio site was extremely good while the DF performance at the MSFC site evidenced erratic behavior. A check of the data acquisition hardware revealed an intermitted problem in one of the radio receiver channels. Since the system has experienced several lightning strikes during the early spring of 1984, it was necessary to ship the entire rack of equipment back to SwRI for refurbishment. Analysis of the DF data from the interferometer site at San Antonio is being done. A limited subset of the MSFC data acquired during Hurricane Alicia has been found to be valid. These were data which satisfied the phase linearity criteria. Approximately 2,000 location estimates have been produced on the valid data. The results of the DF analysis and the location data are being correlated with the McIDAS data base at Marshall Space Flight Center, and with the radar summary data provided by the Hurricane Research Division using the National weather Service radar Facility at Galveston, Texas.

Johnson, R. L.↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallels in Communication and Navigation Technology and Natural Phenomenon

The premise is more than art imitates life, or technology imitates nature it is a nascent step to see how we might be unwittingly inspired and influenced. An example that might immediately come to mind is a starling murmuration (a phenomenon called scale-free correlation) and Intels recent Coachella music festival drone performance. Superconductivity is a macroscopic manifestation of a quantum phenomenon - choreographed electrons (i.e. an electron murmuration) that enable astonishing devices. There is indeed an intimate connectedness between biology and electromagnetism. Our brains are complex neural circuits generating magnetic fields with a magnitude around 100 femtoTesla (roughly one billion times weaker than a typical magnet used to tack notes to a refrigerator door). Migratory birds navigate by orienteering with respect to the Earth's magnetic field. Electromagnetic field therapy is used in orthopedics to aid in bone repair. The electric eel generates a large electric field for self-defense. Sharks apparently detect extremely weak electric fields for finding prey. And so on. There are similarities between the way a field of wheat responds to a breeze and the natural restoring forces of a semiconductor crystal. And waves in a slowly moving river can lap backwards against a peninsular shoreline mimicking a diffraction effect. Getting back to the introductory sentence and mysterious links over cosmic distances, in August 2016, China launched the Quantum Experiments at Space Scale (QUESS) satellite. The technology is based on a non-linear crystal that produces pairs of entangled photons whose attributes apparently remain entwined regardless of how far apart they are separated. This paper will, no doubt superficially, attempt to enumerate and examine these types of connections and parallelisms.

Romanofsky, Robert↗

Electrical measurements in the atmosphere and the ionosphere over an active thunderstorm. I - Campaign overview and initial ionospheric results

The first simultaneous electric field observations performed in the ionosphere and atmosphere over an active nighttime thunderstorm are reported here. In the stratosphere, typical storm-related dc electric fields were detected from a horizontal distance of about 100 km, and transient electric fields due to lightning were measured at several different altitudes. In the ionosphere and mesosphere, lightning-induced transient electric fields in the range of tens of millivolts per meter were detected with rise times at least as fast as 0.2 ms and typical duration of 10-20 ms. The transients had significant components parallel to the magnetic field at 150 km altitude. This implies that either considerable Joule heating occurs or a collective instability is present because of the high drift velocities induced by the transient electric fields. Copious numbers of whistlers were generated by the storm and were detected above but not below the base of the ionosphere. The outline of a new model for direct whistler wave generation over an active thunderstorm is presented based on these observations. The intensity of the observed two-hop whistlers implies that they were amplified along their propagation path and suggests that particles were precipitated in both hemispheres.

Kelley, M. C.↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Electrical conductivity anomaly beneath Mare Serenitatis detected by Lunokhod 2 and Apollo 16 magnetometers

Magnetic fluctuations measured by the Lunokhod 2 magnetometer in the Bay Le Monnier are distinctly anisotropic when compared to simultaneous Apollo 16 magnetometer data measured 1100 km away in the Descartes highlands. This anisotropy can be explained by an anomalous electrical conductivity of the upper mantle beneath Mare Serenitatis. A model is presented of anomalously lower electrical conductivity beneath Serenitatis and the simultaneous magnetic data from the Lunokhod 2 site at the mare edge and the Apollo 16 site are compared to the numerically calculated model solutions. This comparison indicates that the anisotropic fluctuations can be modeled by a nonconducting layer in the lunar lithosphere which is 150 km thick beneath the highlands and 300 km thick beneath Mare Serenitatis. A decreased electrical conductivity in the upper mantle beneath the mare may be due to a lower temperature resulting from heat carried out the magma source regions to the surface during mare flooding.

Vanian, L. L.↗

Electric field measurements during the Condor critical velocity experiment

The instrumentation of the Condor critical velocity Ba experiment (Wescott et al., 1986) for the measurements of the energetic particles and the electric field associated with a Ba explosion is described. The Ba explosion created a complex electric field pulse detected in situ by a single-axis double electric-field probe on a separate spacecraft. The measurements provide evidence of several important links in the critical-velocity chain, and are consistent with two hypotheses. The first hypothesis involves the creation of large polarization electric field due to charge separation; the second hypothesis implies a polarization of the beam by currents flowing across it. The chain of physical processes inferred from the observations is in agreement with most theories for the Alfven process.

Kelley, M. C.↗

Shock Prevention

The electrician pictured is installing a General Electric Ground Fault Interrupter (GFI), a device which provides protection against electrical shock in the home or in industrial facilities. Shocks due to defective wiring in home appliances or other electrical equipment can cause severe burns, even death. As a result, the National Electrical Code now requires GFIs in all new homes constructed. This particular type of GFI employs a sensing element which derives from technology acquired in space projects by SCI Systems, Inc., Huntsville, Alabama, producer of sensors for GE and other manufacturers of GFI equipment. The sensor is based on the company's experience in developing miniaturized circuitry for space telemetry and other spacecraft electrical systems; this experience enabled SCI to package interruptor circuitry in the extremely limited space available and to produce sensory devices at practicable cost. The tiny sensor measures the strength of the electrical current and detects current differentials that indicate a fault in the functioning of an electrical system. The sensing element then triggers a signal to a disconnect mechanism in the GFI, which cuts off the current in the faulty circuit.

Source record↗