Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Mini Guide on Transportation Electrification: State-Level Roles and Collaboration among Public Utility Commissions, State Energy Offices, and Departments of Transportation

About the NCEP Mini Guide Series: The National Council on Electricity Policy (NCEP) is a platform for all state-level electricity decision makers to share and learn from diverse perspectives on the evolving electricity sector. The NCEP mini guide series promotes this dialogue by highlighting examples of successful engagement across its members. Each mini guide features collaborative approaches, lessons learned, and interviews with leading state and local decision makers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reviewing Flexibility in Industrial Electrification: U.S. Green Ammonia and Steel Industries [Slides]

The renewable energy transition in the power sector involves a paradigm shift for flexibility. Supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and delay need for additional capacity and transmission. Industrial customers are larger on average than residential and commercial consumers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. We conclude that the technological innovation systems are not well-functioning for flexibility in EAF based steelmaking, but are in the green ammonia space. Explicit connections between scope two greenhouse gas emissions reporting and flexibility are lacking, and industry stakeholders do not appear to make a connection between decarbonization and load flexibility.

25 ENERGY STORAGE↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of NLR Automated Mobility District Implementation Research - Phases I, II, and III. The Convergence of Automation, Electrification, and On-Demand Services: Enabling Resilient Automated Mobility Districts

A research program by the National Renewable Energy Laboratory has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings, referred to as Automated Mobility Districts (AMDs). An AMD emphasizes the deployment of automated vehicles (AV) passenger transport services within a dense urban setting and other major activity centers with intense passenger origin-destination demand patterns, such as those found in large business districts, airports, and university and medical campuses. Phase I and II surveyed 10 early deployment sites and subsequently collected and evaluated the lessons learned from these early deployment sites, with particular attention to fleet operations, impacts of service reliability, and vehicle technology evolution as the field of companies was being progressively winnowed by the challenges of full automation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVI-Rental: A Scalable Model to Quantify the Impact of Rental Car Electrification

This fact sheet describes the Electric Vehicle Infrastructure - Rental Car (EVI-Rental) tool, a flexible and comprehensive simulation tool that addresses key questions about the charging demand, infrastructure needs, and business impacts of adding growing numbers of electric vehicles (EVs) to rental fleets. To validate the EVI-Rental model, the Athena research team conducted a case study at Dallas-Fort Worth International Airport (DFW) to understand the impact of state-of-charge requirements, different charger types and charging schedules, solar power generation, and behind-the-meter storage on a fully electrified rental car fleet.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated U.S. nationwide corridor charging infrastructure planning for mass electrification of inter-city trips

This study introduces an integrated modeling framework to evaluate long-term national corridor charging infrastructure requirements in the United States to support the growing inter-city charging demand with the rapid growth in the battery electric vehicle (BEV) market. The core model is an optimization model that considers spatial and temporal dimensions and models heterogeneous behaviors between travelers. The model also introduces the travelers’ inconvenience cost function by linking travelers’ acceptance of the charging infrastructure with exogenous technology and social factors. The inconvenience cost function simulates mode choice between BEVs and alternative modes by heterogenous travelers. We applied the framework to assess the inter-regional charging infrastructure requirements for the entire U.S. mainland interstate highway network. We evaluated impacts on the infrastructure design and its public acceptance with changes in policy, technology, and demographic characteristics, and we also quantified the importance of modeling full-scale inter-regional charging infrastructure requirements compared to the conventional regional level analyses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reviewing flexibility in industrial electrification: Focusing on green ammonia and steel in the United States

The renewable energy transition in the power sector involves a paradigm shift for flexibility. Flexible demand is more attainable than before, while supply flexibility faces new constraints due to the increased share of variable renewable resources. Increased demand flexibility can allow less use of peaking power plants and avoid need for additional capacity. Industrial flexibility could be especially interesting in this regard, as industrial customers are larger on average than other customers and have typically provided the largest share of demand response in the United States. We consider industrial demand, studying characteristics of flexible industrial loads. We then examine the dynamics of change occurring around industrial load flexibility by focusing on two case studies: green ammonia and steel production via electric arc furnaces. Electric arc furnace steel production is an important component of current demand response programs, whereas green ammonia and green fuels offer new paradigms for flexibility. We analyze the structure and functions of the technological innovation systems of load flexibility in those two industries via interviews with twenty-two stakeholders. Here, we conclude that in the United States these technological innovation systems are not well-functioning for industry in general or for steel, but do seem to be present for green ammonia. Additionally, explicit connections between scope two greenhouse gas emissions (those from purchased energy) and flexibility are lacking, and likewise industry stakeholders do not appear to make a connection between decarbonization and load flexibility, thus flexible demand is not viewed as a tool in industrial decarbonization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantifying the impacts of micro- and mild- hybrid vehicle technologies on fleetwide fuel economy and electrification

Micro- and mild-hybridization (jointly labeled as M-HEV) is gaining popularity as a cost-effective technology for fuel economy improvement, but whether and how M-HEV may compete against less efficient conventional internal combustion engine vehicles (ICEV), more efficient full hybrid electric vehicles (HEV), and plug-in electric vehicles (PEV) is not well understood. As such, this study aims at evaluating the impact of the market adoption of M-HEV on the average fuel economy of the new vehicle fleet and on the sales share of PEVs. The study reviews recent sales trends and market forecasts, and uses published estimates of manufacturing cost and fuel economy of M-HEV with an existing discrete choice model (Market Acceptance of Advanced Automotive Technologies or MA3T) to project the market penetration and impacts of M-HEV under different scenarios of M-HEV choice positions, designed to enhance conclusion robustness. It is found that among engine-based powertrain choices, micro-HEV appears to be the most cost-effective, followed by ICEVs, mild-HEV and finally full HEVs. M-HEV technologies are likely to improve fleetwide average fuel economy without significant adverse effects on sales of plug-in electric vehicles, and are likely to remain highly competitive outside PEVs through 2050.

33 ADVANCED PROPULSION SYSTEMS↗

Electrification and decarbonization of spent Li-ion batteries purification by using an electrochemical membrane reactor

The expanding electric vehicle market brings with it exponential growth in the use of lithium (Li)-ion batteries (LIB) for which a wave of spent LIB is expected to come within the next 5 to 10 years. Due to the economic and strategic value imbedded within the metals contained in LIB, different recycling technologies, including hydrometallurgy, pyrometallurgy and direct recycling, are under development. Being different from previous hydrometallurgical methods, which may have high chemical consumption and negative environmental impact, an electrochemical membrane reactor is designed and validated for the first time, to electrify and decarbonize the impurity removal process. This reactor electroplates copper (Cu) and electrochemically precipitates aluminum (Al) and iron (Fe) from simulated spent LIB leachates, by consuming only air, water, and electricity, and the impurities are reduced to <1 ppm. The purified leachate maintains 99.5 % of the nickel (Ni), 95.4 % of the cobalt (Co) and 99.14 % of manganese (Mn) from the original leachate solution, and then can be directly applied for cathode precursor synthesis. Additionally, the purification process doesn’t introduce extra impurity, and the reactor restoration process generates valuable by-product hydro sulfate (H2SO4). This electrochemical process can reduce the cost, because of the much less chemical consumption and the valuable by-product generation, and mitigates the waste emissions, because of no extra impurity introduced and no greenhouse gas (GHG) produced. In conclusion, the chemical precipitation method uses significant amount of NaOH, which induced GHG emission during the manufacturing process.

25 ENERGY STORAGE↗

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗