Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy - Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Route Optimization for Energy Efficient Airport Shuttle Operations - A Case Study from Dallas Fort Worth International Airport

Air travel and requisite surface traffic supporting passenger arrival/departure constitutes a significant portion of travel and emissions in cities with large airports. An airport trip can segment into three parts namely: i) travel from a location in the city to the airport; ii) travel from a parking lot or rental car center to the terminal (i.e., within the airport premises), and iii) travel inside the terminal. Depending on the airport access mode all or a part of these legs comprise a traveler’s journey to the airport. The priority of airport ground transport management teams is to provide passengers with a seamless travel experience within the airport, so it is understandable that within airport shuttle routes might not be optimized for minimizing energy consumption. Solutions that meet the dual objective of reducing energy consumption from airport shuttle operations without compromising on passenger travel experience are key to improving system efficiency. There is currently a dearth of research and tools that can inform airports in making such decisions. Addressing this need, this research effort puts forth an optimization model that generates optimal shuttle routes for a given set of constraints, and a discrete-event simulator that evaluates the optimal solutions in a stochastic environment to understand the tradeoffs between passenger wait times, and within airport shuttle energy consumption. The proposed set of tools are tested in the context of optimizing airport shuttles routes within the Dallas Fort Worth International Airport (DFW). In addition to shuttle spatial positioning, and passenger demand information, high-fidelity vehicle data was collected using data loggers installed on DFW shuttles. Results show that 20% energy reduction in shuttle operations is possible with a modest two-minute increase in average passenger wait times. The tools developed in this research effort are designed to be generalizable and can help optimize shuttle operations planning at any major airport.

air travel↗

Increasing the Reach of Low-Income Energy Programmes through Behaviourally Informed Peer Referral

Subsidized energy assistance programmes are a popular policy tool for promoting energy justice, but, like other social benefits programmes, are often undersubscribed. To improve uptake, some programmes have turned to social influence strategies, such as asking programme participants to refer their peers. Here, through a field experiment with California's low-income solar programme (N = 7,676), we show that referral behaviour depends on how existing participants are approached. Adding behavioural science strategies to a referral reward increases peer referral rates, referral quality and ultimately solar adoption. Compared with only reminding existing adopters of a potential US$200 reward for referrals that result in adoption, adding an appeal to reciprocity through a non-contingent US$1 gift - and further combining this gift with a simplified referral process - leads to 2.6-5.2 times as many solar contracts. These results highlight the potential of behaviourally informed peer referral programmes to accelerate equitable access to clean energy.

California↗

High Energy Physics Network Requirements Review: Final Report, July 2024–December 2024

The world-class research infrastructure at the US Department of Energy (DOE) Office of Science (SC) provides the research community with premier observational, experimental, computational, and network capabilities. Each user facility is designed to provide unique capabilities to advance the core DOE mission in science and technology for its SC program to stimulate rich scientific discoveries and enhance its innovation ecosystem. Research communities gather and flourish around each user facility, bringing together new and enhanced perspectives. The continual reinvention of the practice of science — as users and staff forge novel approaches expressed in research workflows — unlocks new discoveries and propels scientific progress. Within this research ecosystem, the high-performance computing (HPC) and networking user facilities stewarded by the SC’s Advanced Scientific Computing Research (ASCR) program play a dynamic cross-cutting role, enabling complex workflows demanding high-performance data, networking, and computing solutions. The ASCR facilities enterprise seeks to understand and meet the needs and requirements across SC and DOE domain science programs and priority efforts, highlighted by the formal requirements review methodology. Between July and December 2024, the Energy Sciences Network (ESnet) and the Office of High Energy Physics (HEP) of the DOE-SC organized an ESnet requirements review of HEP-supported program activities. Preparation for these events included identification of key stakeholders: program and facility management, research groups, and technology providers. Each stakeholder group was asked to prepare formal case study documents about its relationship to the HEP program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementing Clean Energy Transitions for Small Communities: NREL Supports Sierra Club Florida in Efforts to Help Florida Communities Achieve 100% Renewable Energy

Sierra Club Florida's "Clean Energy for All" campaign helps communities in Florida transition to 100% clean energy. The organization sought the help of National Renewable Energy Laboratory (NREL) analysts to achieve to achieve two goals: (1) create a Clean Energy Toolkit to help communities in Florida and across the country find data and and analysis to achieve clean energy goals, and (2) provide direct analysis of local clean energy potential for two Florida communities, the cities of Tallahassee and Sarasota.

clean energy toolkit↗

Modeling nuclear energy’s future role in decarbonized energy systems

Increased attention has been focused on the potential role of nuclear energy in future electricity markets and energy systems as stakeholders target rapid and deep decarbonization and reductions in fossil fuel use. This paper examines models of electric sector planning and broader energy systems optimization to understand the prospective roles of nuclear energy and other technologies. In this perspective, we survey modeling challenges in this environment, illustrate opportunities to propagate best practices, and highlight insights from the deep decarbonization literature on the range of visions for nuclear energy's role. Nuclear energy deployment is highest with combinations of stringent emissions policies, nuclear cost reductions, and constraints on the deployment of other technologies, which underscores model dimensions related to these areas. New modeling capabilities are needed to adequately address emerging issues, including representing characteristics and applications of nuclear energy in systems models, and to ensure the relevance of models for policy and planning as deeper decarbonization is explored.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Examination of How Well Long-Range-Corrected Density Functionals Satisfy the Ionization Energy Theorem

For this work, we calculated the vertical ionization energies (VIE) of 99 species in two ways to examine the accuracy of several long-range-corrected (LC) hybrid meta functionals in comparison with a gradient approximation (GA), global hybrids, and doubly hybrids. In the category of LC functionals, we examined both those with meta ingredients (i.e., that depend on the kinetic energy density) and those without them. The LC-hybrid meta functionals examined are M11, revM11, M11plus, and ωB97M-V. The reference data used to assess accuracy consist of 95 molecules and 4 atoms in the GW100 set. The two methods studied are the ΔSCF method (involving the difference of neutral and cation self-consistent field (SCF) energies) and the ionization energy theorem (involving the orbital energy of the highest occupied molecular orbital, HOMO). We calculated linear correlation coefficients (r 2 ) and mean absolute deviations (MADs) between each approach and the reference VIE value from the CCSD(T)/def2-TZVPP level of theory. We compared the new LC-hybrid meta calculations to calculations with the 10 functionals in a previous VIE study by Brémond et al. and to the calculations with LC-BLYP (LC-Becke, Lee–Yang–Parr), CAM-B3LYP (Coulomb-attenuating-method Becke-3-parameter Lee–Yang–Parr), LC-ωHPBE, and ωB97X-D. The results show that Minnesota LC-hybrid meta functionals have the smallest mean absolute deviation of ionization energy theorem VIEs with the reference data; the LC-ωHPBE functional also does quite well in this test. This is very encouraging and indicates that LC-hybrid meta functionals would be the best starting points for the tuning strategy that has been shown to be a very good procedure for improving time-dependent density functional calculations, and it also helps explain the good success of LC-hybrid meta functionals for molecular excitation energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

U.S.-China Clean Energy Research Center Building Energy Efficiency (CERC-BEE) Open-Source Retrofit Targeting Tool (CRADA FP00007338 Final Report)

To increase the cost-saving energy and carbon dioxide (CO 2 ) emissions reductions in buildings and portfolios at the scale and speed necessary to limit climate change, researchers at LBNL and Johnson Controls (JCI) developed the Building Efficiency Targeting Tool for Energy Retrofits (BETTER). BETTER is a software tool that consists of three components: (1) the BETTER analytical engine source code (which was developed with intellectual property provided by JCI under CRADA FP00007338); (2) the BETTER web application, developed by LBNL and McQuillen Interactive Pty. Ltd; and (3) the BETTER application programming interface (API), also developed by LBNL and McQuillen Interactive Pty. Ltd. BETTER enables building and portfolio owners, managers, and service providers worldwide to quickly, easily identify cost-saving energy efficiency retrofits in existing buildings and portfolios without expensive site visits or complex modeling. With minimal data input, the tool benchmarks a building’s electric and fossil energy usage against peers; quantifies energy, cost and greenhouse gas (GHG) emission reduction potentials at the building and portfolio levels; and recommends energy efficiency measures to decarbonize and electrify buildings and portfolios, targeting specific energy savings levels. No other tool so comprehensively analyzes buildings and portfolios with such ease. If fully implemented, it is estimated that BETTER could help reduce emissions equivalent to planting 1.3 billion trees globally by 2030. Moreover, an additional 50-75% of embodied GHG emissions could be avoided in each case where BETTER results in a building being retrofitted instead of demolished and replaced, providing substantial additional decarbonization benefits for the buildings sector. BETTER has garnered multiple awards and avid interest from investors. In 2020, it earned a R&D 100 Award for innovation and a LBNL Director’s Award for Technology Transfer. In 2021, BETTER was named an EarthX E-Capital Summit Climate Tech Prize semi-finalist

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Energy Use and Making Energy More Efficient in the Native Village of Kiana (Final Technical Report)

The goal of the Remote Alaska Community Energy Efficiency (RACEE) Competition was to advance the implementation of affordable, resilient, and clean energy-efficient solutions for remote Alaska communities. RACEE assisted Kiana with its unique challenges, mostly the remote nature of their location paired with the harsh temperatures and isolated electrical grid resulting in high energy costs. In addition to the assistance from DOE, the Alaska Energy Authority (AEA) provided direct technical assistance to RACEE recipients throughout their projects. Before Kiana started work, AEA conducted energy audits in public buildings and facilities to identify which energy measures would be most effective for the community’s energy goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Just Transition Principles: Prepared for the APEC Energy Working Group Workshop on Promoting a Just Energy Transition

A global energy transition from fossil energy to clean energy is unfolding. Just transition is an iterative, continuous process of moving from a fossil-fuel economy to a green economy that provides decent, productive, and ecologically sustainable livelihoods; nurtures social dialogue; and equitably distributes costs and benefits of the energy system. It is aimed at supporting affected workers and communities and affirms that the transition is towards a more equitable energy system. Though the Asia-Pacific Economic Cooperation (APEC) region as a whole is largely representative of global energy transition trends, APEC’s member economies – and communities within them – will have their own transition nuances. Approaches to just transition must therefore recognize both the global and the local transition dynamics. The report offers eight just transition principles that can help inform work that assures the current energy transition, and its future iterations, are fair and equitable.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Next-Level Energy Management in Manufacturing: Facility-Level Energy Digital Twin Framework Based on Machine Learning and Automated Data Collection

This research introduces an energy prediction framework at the facility level supported by automated data collection and machine learning models. It investigates whether reducing the prediction time scale allows for applying more complex machine learning techniques and if those techniques improve the prediction accuracy. The primary advantages of this framework lie in its automation of the energy prediction process and its provision of real-time energy data suitable for use in energy dashboards or digital twins. A sitewide dataset was created by combining 15 min energy and daily production data of five shops—assembly, battery, body (electric), body (gas), and paint—from a globally recognized electric vehicle manufacturer. Various machine learning models were evaluated on daily, weekly, and monthly datasets, including, in increasingly complex order: naïve, simple linear regression, net regularized generalized linear regression, principal component regression, k-nearest neighbor, random forest, and Bayesian regularized neural network. Compared to the current state-of-the-art energy consumption prediction for the industrial facility level, this research investigates more complex models and smaller time intervals for higher accuracy. The findings revealed that the more complex monthly models require a minimum of a year and a half of data to operate, while weekly models demand a year of data to achieve improved accuracy. Daily models can operate with only six months of data but exhibit poor performance due to reduced prediction accuracy of production. Key challenges identified include access to reliable, high-quality energy and production data and the initial demand for human labor.

digital twin↗

A Search for Photons with Energies Above 2 × 10 17 eV Using Hybrid Data from the Low-Energy Extensions of the Pierre Auger Observatory

Ultra-high-energy photons with energies exceeding 10 17 eV offer a wealth of connections to different aspects of cosmic-ray astrophysics as well as to gamma-ray and neutrino astronomy. The recent observations of photons with energies in the 10 15 eV range further motivate searches for even higher-energy photons. In this paper, we present a search for photons with energies exceeding 2 × 10 17 eV using about 5.5 yr of hybrid data from the low-energy extensions of the Pierre Auger Observatory. The upper limits on the integral photon flux derived here are the most stringent ones to date in the energy region between 10 17 and 10 18 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Conducting thermal energy to the membrane/water interface for the enhanced desalination of hypersaline brines using membrane distillation

Membrane distillation (MD) is a membrane-based thermal desalination process capable of treating hypersaline brines. Standard MD systems rely on preheating the feed to drive the desalination process. However, relying on the feed to carry thermal energy is limited by a decline of the thermal driving force as the water moves across the membrane, and temperature polarization. In contrast, supplying heat directly into the feed channel, either through the membrane or other channel surfaces, has the potential of minimizing temperature polarization, increasing single-pass water recoveries, and decreasing the number of heat exchangers in the system. When solar thermal energy can be utilized, particularly if the solar heat is optimally delivered to enhance water evaporation and process performance, MD processes can potentially be improved in terms of energy efficiency, environmental sustainability, or operating costs. Here we describe an MD process using layered composite membranes that include a high-thermal-conductivity layer for supplying heat directly to the membrane-water interface and the flow channel. Here, the MD system showed stable performance with water flux up to 9 L/m 2 /hr, and salt rejection >99.9% over hours of desalinating hypersaline feed (100 g/L NaCl). In addition to bench-scale system, we developed a computational fluid dynamics model that successfully described the transport phenomena in the system.

42 ENGINEERING↗

Methodology for Evaluating Energy Savings, Cost-Effectiveness, and Societal Impacts of Commercial Energy Code Changes

This document lays out the Department of Energy’s (DOE’s) methodology for evaluating the cost-effectiveness of energy code and standard proposals and editions. The evaluation is applied to new provisions or editions of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code. The methodology follows standard lifecycle cost (LCC) economic analysis procedures. A cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes; 2) evaluating the incremental and replacement costs related to the changes; and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Expert Elicitation for Tidal Energy Levelized Cost of Energy: Present and Future

In accordance with the Government Performance and Results Act (GPRA), H2O annually assesses marine energy technology development resulting from government-funded research and development programs and strategy. For GPRA reporting, H2O uses the levelized cost of energy (LCOE) - which represents the total system cost per unit of energy produced - to measure the progression of marine energy technology development, assess the impact of their research and development programs, and identify future research priorities. To support H2O's GPRA reporting requirements and inform future strategy, the National Laboratory of the Rockies conducted a tidal energy LCOE expert elicitation study to estimate present and future LCOE[AB2.1]. This report describes the motivation and background for the elicitation study, the methodology used to conduct the study, and the study results. It also provides future recommendations for accelerated tidal energy LCOE reduction based on feedback from study participants.

16 TIDAL AND WAVE POWER↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adsorbate Free Energies from DFT-Derived Translational Energy Landscapes

Adsorption free energies are fundamental to surface chemistry and catalysis. Standard models combine some assumed analytical form of the translational potential energy surface, often parameterized against density functional theory (DFT) calculations, with an analytical expression for the resultant translational densities of states (DOS), free energy, and entropy. Here we compare the performance of such models against numerical evaluations of the DOS and thermodynamic functions derived from solutions to the translational Schrodinger equation. We compare results for a translational potential energy surface (PES) derived from nudged eleastic band calculations with those obtained from adsorbate rastering across a series of monatomic (O, S, C, N, H) and polyatomic (NH x ) adsorbates on (100) Pt and Au facets. We find that analytical models as commonly parameterized have mixed performance for describing the translational PES and that the consequences for computed free energies are modest but potentially significant in microkinetic models. Here, numerical solutions are possible for modest to no additional computational cost over analytical models and thus should be considered when reliable free energy estimates are needed or translational potential energy surfaces are available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗