Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

evmc-supply-curves (Electric Vehicle Managed Charging Supply Curves) [SWR-25-69]

Data and a supporting lightweight Python package that describes possible costs for enabling EV managed charging from 2025 to 2050 for three dispatch mechanisms: Time-of-Use (TOU), Real Time Pricing (RTP), and direct load control (DLC) and four flexibility scenarios (Flat and Low, Mid, and High Flex).

Matsuda-Dunn, Reiko [National Renewable Energy Lab↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Data Centers and Digital Assurance Introduction to Supply Chain and Cybersecurity for Data Centers, Session 1

The first session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort Workshop, held on October 30, 2025, introduced foundational concepts of Digital Assurance in the context of data center and grid integration. Sponsored by the U.S. Department of Energy, the workshop brought together utilities, data center operators, developers, and vendors to address cybersecurity and supply chain vulnerabilities. The session emphasized the growing criticality of data centers within the electric grid and the need for secure, real-time, bidirectional communication. Participants explored the principles of Digital Assurance, including cybersecurity, cyber-informed engineering (CIE), and lifecycle security, and applied a threat-vulnerability-consequence framework to identify and mitigate risks at the data center–grid interface. Discussions covered a range of threats such as spoofed dispatch signals and insider threats, architectural vulnerabilities like SCADA interfaces and insecure protocols, and potential consequences including cascading grid failures. The session also raised strategic questions about business value, vendor assurance, and defining cyber boundaries and responsibilities. This foundational workshop set the stage for deeper technical analysis and the development of actionable frameworks in subsequent sessions. Session 1 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS↗

Tightest Mixed-Integer Programming Formulations for Quadratic SCUC Optimization

In this project, we developed new, tighter Mixed-Integer Programming (MIP) formulations for the combined Alternating Current (AC) Security-Constrained Unit Commitment (SCUC) and Security-Constrained Optimal Power Flow (SCOPF). The work addresses a critical challenge in power system operations: efficiently determining which generation units to commit and how to optimally dispatch them while maintaining network reliability constraints for both normal and contingency scenarios. Our efforts: 1. Advance the Understanding of SCUC/SCOPF Modeling: By introducing tighter MIP formulations and leveraging cutting-edge optimization tools (Julia/JuMP, PowerModels.jl), this project has pushed forward the state of the art in efficient power systems scheduling. 2. Enhance Technical and Economic Feasibility: The methods developed provide more accurate and potentially faster solutions to large-scale, realistic scheduling and dispatch problems in electric power systems, which can translate into improved reliability and potentially lower costs for grid operations. 3. Benefit to the Public: Greater efficiency in power system operations leads to cost savings for utilities and end-users. Improved reliability and integration of advanced modeling approaches can facilitate the adoption of clean energy resources and better accommodate uncertainties in renewable generation. Because this technology could impact bulk power markets and reliability, these innovations have far-reaching public benefits in terms of cost savings, reliability, and sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

HydraGNN v4.0

The new version of HydraGNN v4.0 provides additional core capabilities, such as: Inclusion of multi-body atomistic cluster expansion MACE, polarizable atom interaction neural network PAINN, and equivariant principal neighborhood aggregation (PNAEq) among the message passing layers supported -Inclusion of graph transformers to directly model long-range interactions between nodes that are distant in the graph topology Integration of graph transformers with message passing layers by combining the graph embedding generated by the two mechanisms, which allows for an improved expressivity of the HydraGNN architecture Improved re-implementation of multi-task learning (MTL) to allow its use for stabilized training across imbalanced, multi-source, multi-fidelity data Introduction of multi-task parallelism, a newly proposed type of model parallelism specifically for MTL architectures, which allows to dispatch different output decoding heads to different GPU devices Integration of multi-task parallelism with pre-existing distributed data parallelism to enable a 2D parallelization for distributed training Improved portability of the distributed training across Intel GPUs, which has been testes on ALCF exascale supercomputer Aurora Inclusion of 2-level fine-grained energy profilers portable across NVIDIA, AMD, and Intel GPUs to monitor the power and energy consumption associated with different functions executed by the HydraGNN code during data pre-load and training Restructuring of previous examples and inclusion of new sets of examples to illustrate the download, preprocess, and training of HydraGNN models on new large-scale open-source datasets for atomistic materials modeling (e.g., Alexandria, Transition1x, OMat24, OMol25)

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗

AQDrop Quantum Service (AQDrop) v1.0

AQDrop is a job management system designed to streamline access to the Advanced Quantum Testbed (AQT) at NERSC (National Energy Research Scientific Computing Center). It serves as a centralized middleware layer between researchers and quantum processing hardware. Key Features: AQDrop provides a FastAPI-based server backed by PostgreSQL for job submission, queue management, and role-based access control (members, operators, and administrators). Users submit Qiskit circuits via JSON payloads, which are queued, dispatched to the QPU through the Qubic API, and returned as measurement counts. A Python client library and web dashboard round out the interface options. Primary Use: Researchers submit quantum circuit jobs from a laptop or login node; an operator client executes those jobs on the AQT's physical QPU and returns results — all coordinated through the central API. Advantages: Compared to ad-hoc or direct hardware access, AQDrop adds structured queue management, auditable job-status tracking and OAuth2 authentication — reducing scheduling conflicts and unauthorized access. Its containerized deployment also improves reproducibility and scalability. Overall, AQDrop functions as a purpose-built quantum job broker tailored to NERSC's specific hardware and institutional access requirements.

Caplinger, Evan [Lawrence Berkeley National Labora↗

Modern deep neural networks for Direct Normal Irradiance forecasting: A classification approach

The escalating energy demand and the adverse environmental impacts of fossil-fuel use necessitate a shift towards cleaner and renewable alternatives. Concentrated Solar Power (CSP) technology emerges as a promising solution, offering a carbon-free alternative for power generation. The efficiency and profitability of CSP depend on the Direct Normal Irradiance (DNI) component of solar radiation; hence, accurate DNI forecasting can help optimize CSP plants’ operations and performance. The unpredictable nature of weather phenomena, particularly cloud cover, introduces uncertainty into DNI projections. Existing DNI forecasting models use meteorological factors, which are both challenging to estimate numerically over short prediction windows and expensive to model through data at a sufficiently high spatial and temporal resolution. This research addresses the challenge by presenting a novel approach that formulates DNI prediction as a multi-class classification problem, departing from conventional regression-based methods. The primary objective of this classification framework is to identify optimal periods aligning with specific operational thresholds for CSP plants, contributing to enhanced dispatch optimization strategies. We model the DNI classification problem using four advanced deep neural networks – rectified linear unit (ReLU) networks, 1D residual networks (ResNets), bidirectional long short-term memory (BiLSTM) networks, and transformers – achieving accuracies up to 93.5% without requiring meteorological parameters.

14 SOLAR ENERGY↗

Onboard Determination of Vehicle Glide Capability for Shuttle Abort Flight Managment (SAFM)

When one or more main engines fail during ascent, the flight crew of the Space Shuttle must make several critical decisions and accurately perform a series of abort procedures. One of the most important decisions for many aborts is the selection ofa landing site. Several factors influence the ability to reach a landing site, including the spacecraft point of atmospheric entry, the energy state at atmospheric entry, the vehicle glide capability from that energy state, and whether one or more suitable landing sites are within the glide capability. Energy assessment is further complicated by the fact that phugoid oscillations in total energy influence glide capability. Once the glide capability is known, the crew must select the "best" site option based upon glide capability and landing site conditions and facilities. Since most of these factors cannot currently be assessed by the crew in flight, extensive planning is required prior to each mission to script a variety of procedures based upon spacecraft velocity at the point of engine failure (or failures). The results of this preflight planning are expressed in tables and diagrams on mission-specific cockpit checklists. Crew checklist procedures involve leafing through several pages of instructions and navigating a decision tree for site selection and flight procedures - all during a time critical abort situation. With the advent of the Cockpit Avionics Upgrade (CAU), the Shuttle will have increased on-board computational power to help alleviate crew workload during aborts and provide valuable situational awareness during nominal operations. One application baselined for the CAU computers is Shuttle Abort Flight Management (SAFM), whose requirements have been designed and prototyped. The SAFM application includes powered and glided flight algorithms. This paper describes the glided flight algorithm which is dispatched by SAFM to determine the vehicle glide capability and make recommendations to the crew for site selection as well as to monitor glide capability while in route to the selected site. Background is provided on Shuttle entry guidance as well as the various types of Shuttle aborts. SAFM entry requirements and cockpit disp lays are discussed briefly to provide background for Glided Flight algorithm design considerations. The central principal of the Glided Flight algorithm is the use of energy-over-weight (EOW) curves to determine range and crossrange boundaries. The major challenges of this technique are exo-atmospheric flight, and phugoid oscillations in energy. During exo-atmospheric flight, energy is constant, so vehicle EOW is not sufficient to determine glide capability. The paper describes how the exo-atmospheric problem is solved by propagating the vehicle state to an "atmospheric pullout" state defined by Shuttle guidance parameters.

Straube, Timothy↗

CyRRL (Cyber Resilient Reinforcement Learning for grid voltage control) [SWR-24-115]

This codebase contains a multi-agent, actor-critic reinforcement learning implementation for cyber-resilient grid voltage control. It uses a 123-bus OpenDSS system as the environment, with three-phase power flow translating nodal power injections into solved nodal voltages. The reward function penalizes deviations from nominal voltage as well as reactive power dispatch, while encouraging agents to take actions that result in fast convergence to nominal conditions. The codebase models false data injection attacks and includes functionality for training, testing, hyper-parameter tuning, and visualization.

Murphy, Sinnott [National Renewable Energy Laborat↗

Model Formulations: Integrating Distributed Energy Resources (DER) using Advanced Unit Commitment Models and DER Aggregation Methodologies

A distribution energy resource aggregator (DERA) constitutes a group of distribution energy resources with small generation capacities which meet the threshold to participate in the electricity wholesale market. This document provides the proposed DERA model formulation that will be implemented in the SCUC simulation’s architecture for the SCUC-DER project. Different economical assessment methodologies have been developed to incorporated bids for individual distributed resources, which include solar cost dispatch and cost model, BESS opportunity cost offer algorithm, and price sensitive demand response model. Detailed methods are proposed to aggregate individual cost offers to a DERA cost curve to bid in SCUC market while three methods are proposed to simulate DER actual dispatch. Based on the DERA models in this document, the SCUC-DER project will be able to assess the impacts of DERA on the distribution system’s operation and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Swing Contract-Based Valuation for Distributed Energy Resources in Transactive Energy Systems: A Reinforcement Learning Approach

With the proliferation of distributed energy resources (DERs) and power grids with high fractions of renewable energy, market constructs are evolving to allow DERs to participate in multiple possible markets, at different levels of grid hierarchy. The effective participation of DERs in market environments is aided by swing contract-based pricing mechanisms, whereby DERs have a two-part compensation structure – one for their reservation/commitment and another for performancedriven ex-post payment for their actual mobilization during dispatch. In this paper, we propose a reinforcement learningbased (Q-learning) approach that allows a rational DER agent to select the market it wants to participate in within a composite market environment where individual markets are coordinated by possibly different actors. The proposed Q-learning framework aids DERs in their self-valuation by implicitly maximizing their own payoff through market participation, assuming a swing contract-based compensation structure. We complement our work through simulation-based investigations where factors affecting the DER decision making process, such as parametric uncertainties in market (and grid) environments, are studied.

Naqvi, Syed Ahsan Raza↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗