Search NASA⌕ Search

SEARCH · Search NASA

Results for “Event camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Nagoya cosmic-ray muon spectrometer 3, part 2: Track detector

The twelve wide gap spark chambers were utilized as the track detectors of the Nagoya cosmic-ray muon spectrometer not only to obtain the precise locations of particles, but also to get some information about the correspondences between segments of trajectories. The area of each chamber is 150 x 70 sq cm and the width of a gap is 5 cm. The gas used is He at the atmospheric pressure. Each three pairs of them are placed on both sides of the deflection magnet. All images of sparks for each event are projected through the mirror system and recorded by two cameras stereoscopically. The mean detection efficiency of each chamber is 95 + or - 2% and the spacial resolution (jitter and drift) obtained from the prototype-experiment is 0.12 mm. Maximum detectable momentum of the spectrometer is estimated at about 10 TeV/c taking into account these characteristics together with the effects of the energy loss and multiple Coulomb scattering of muons in the iron magnet.

Shibata, S.↗

Search for TeV gamma-ray emission from Hercules X-1

Six years of observations of Hercules X-1 with the Whipple Observatory gamma-ray telescope have been subjected to a Fourier analysis to search for emission at the 0.8079 Hz neutron star frequency. Evidence for a signal is found at the 99.5 percent confidence level for data taken with the medium-resolution imaging camera with some indications of emission at frequencies blueshifted from the fundamental frequency. However, analysis of the high-resolution camera data base have failed to substantiate this effect. Selection of events on the basis of gamma-ray-like image parameters did not enhance the signal from the medium-resolution data nor produce any indication of a signal from the high-resolution data. The overall conclusion is that no statistically significant evidence for TeV gamma-ray emission was found in the Whipple Observatory data base when the 6 years of data are taken as a whole.

Reynolds, P. T.↗

The occultation of SAO 78505 by Jupiter

On 13 December 1989, Jupiter occulted a star with visual magnitude 8.7 and an estimated K magnitude of 7. We observed the event from Kitt Peak, Arizona, using a 64 x 64 infrared camera at a wavelength of 2.16 microns. The resulting data on refractive defocusing of the stellar signal give information on the temperature of the jovian atmosphere at pressures approximately 2 to 10 microbar, at near-equatorial latitudes. These are the first new stellar-occulation data for the high jovian atmosphere since the widely observed occulation of beta Sco A and C in 1971. Because of improvements in instrumental capability, our data are comparable to the best beta Sco A data though the star is six magnitudes fainter. We derive a mean atmospheric temperature of 176 +/- 12 K on a level surface corresponding to an equatorial radius of 71,880 km and a pressure of 1.8 microbar at a jovi- centric latitude of 8 deg. This result complements the beta Sco results by providing improved precision at low jovicentric latitudes where the fainter star beta Sco C was used in 1971.

Hubbard, W. B.↗

CLASS Observation of Polarized Cloud Emission at Millimeter Wavelengths

The dynamic atmosphere imposes challenges to ground-based cosmic microwave background observation, especially for measurements on large angular scales. The hydrometeors in the atmosphere, mostly in the form of clouds, scatter the ambient thermal radiation and are known to be the main linearly polarized source in the atmosphere. This scattering-induced polarization is significantly enhanced for ice clouds due to the alignment of ice crystals under gravity, which are also the most common clouds seen at the millimeter-astronomy sites at high altitudes. This work presents a multifrequency study of cloud polarization observed by the Cosmology Large Angular Scale Surveyor experiment on Cerro Toco in the Atacama Desert of northern Chile, from 2016–2022, at the frequency bands centered around 40, 90, 150, and 220 GHz. Using a machine-learning-assisted cloud classifier, we made connections between the transient polarized emission found in all four frequencies with the clouds imaged by monitoring cameras at the observing site. The polarization angles of the cloud events are found to be mostly 90° from the local meridian, which is consistent with the presence of horizontally aligned ice crystals. The90 and 150 GHz polarization data are consistent with a power law with a spectral index of 3.90±0.06, while an excess/deficit of polarization amplitude is found at 40/220 GHz compared with a Rayleigh scattering spectrum. These results are consistent with Rayleigh-scattering-dominated cloud polarization, with possible effects from supercooled water absorption and/or Mie scattering from a population of large cloud particles that contribute to the220 GHz polarization.

Earth's clouds↗

Wind turbine sensor array for monitoring avian and bat collisions

Assessment of avian and bat collisions with wind turbines is necessary to ensure that the benefits of renewable wind power generation are not outweighed by mortality of protected species. An onboard, integrated multisensor system capable of providing detection of turbine collision events, including taxonomic information, was developed. The conceptual design of a multisensor system including a vibration sensing node, an optics node, and an bioacoustic node with an event–driven trigger architecture was field–tested on utility–scale wind turbines. A pixel density computational model was built to estimate the spatial coverage and target resolution to the optimized configuration for camera placement. Field test results of the vibration node showed that nearly half of the recorded impact events were successfully identified by visual inspection and running short–time Fourier transform on recorded vibration signals. The remaining undetected impact events were masked under background noise due to low impact energy and high background noise of the operating turbine, which result in subsequent low signal–to–noise ratio. Furthermore, our results demonstrate the feasibility of triggering the system through single impact event sensed by vibration sensors.

17 WIND ENERGY↗

Characterisation and testing of CHEC-M—A camera prototype for the small-sized telescopes of the Cherenkov telescope array

The Compact High Energy Camera (CHEC) is a camera design for the Small-Sized Telescopes (SSTs; 4 m diameter mirror) of the Cherenkov Telescope Array (CTA). The SSTs are focused on very-high-energy γ-ray detection via atmospheric Cherenkov light detection over a very large area. This implies many individual units and hence cost-effective implementation, as well as shower detection at large impact distance, and hence large field of view (FoV), and efficient image capture in the presence of large time gradients in the shower image detected by the camera. CHEC relies on dual-mirror optics to reduce the plate-scale and make use of 6 x 6 mm 2 pixels, leading to a low-cost (~150 k€), compact (0.5 m x 0.5 m), and light (~45 kg) camera with 2048 pixels providing a camera FoV of ~9 degrees. The CHEC electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application-specific integrated circuits (ASICs) and field programmable gate arrays (FPGAs) sampling incoming signals at a gigasample per second, with flexible camera-level triggering within a single backplane FPGA. CHEC is designed to observe in the γ-ray energy range of 1–300 TeV, and at impact distances up to 500 m. To accommodate this and provide full flexibility for later data analysis, full waveforms with 96 samples for all 2048 pixels can be read out at rates up to ~900 Hz. The first prototype, CHEC-M, based on multi-anode photomultipliers (MAPMs) as photosensors, was commissioned and characterised in the laboratory and during two measurement campaigns on a telescope structure at the Paris Observatory in Meudon. Here in this paper, the results and conclusions from the laboratory and on-site testing of CHEC-M are presented. They have provided essential input on the system design and on operational and data analysis procedures for a camera of this type. In conclusion, a second full-camera prototype based on Silicon photomultipliers (SiPMs), addressing the drawbacks of CHEC-M identified during the first prototype phase, has already been built and is currently being commissioned and tested in the laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

60 APPLIED LIFE SCIENCES↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Real time imaging of live cell ATP leaking or release events by chemiluminescence microscopy

The purpose of this research was to expand the chemiluminescence microscopy applications in live bacterial/mammalian cell imaging and to improve the detection sensitivity for ATP leaking or release events. We first demonstrated that chemiluminescence (CL) imaging can be used to interrogate single bacterial cells. While using a luminometer allows detecting ATP from cell lysate extracted from at least 10 bacterial cells, all previous cell CL detection never reached this sensitivity of single bacteria level. We approached this goal with a different strategy from before: instead of breaking bacterial cell membrane and trying to capture the transiently diluted ATP with the firefly luciferase CL assay, we introduced the firefly luciferase enzyme into bacteria using the modern genetic techniques and placed the CL reaction substrate D-luciferin outside the cells. By damaging the cell membrane with various antibacterial drugs including antibiotics such as Penicillins and bacteriophages, the D-luciferin molecules diffused inside the cell and initiated the reaction that produces CL light. As firefly luciferases are large protein molecules which are retained within the cells before the total rupture and intracellular ATP concentration is high at the millmolar level, the CL reaction of firefly luciferase, ATP and D-luciferin can be kept for a relatively long time within the cells acting as a reaction container to generate enough photons for detection by the extremely sensitive intensified charge coupled device (ICCD) camera. The result was inspiring as various single bacterium lysis and leakage events were monitored with 10-s temporal resolution movies. We also found a new way of enhancing diffusion D-luciferin into cells by dehydrating the bacteria. Then we started with this novel single bacterial CL imaging technique, and applied it for quantifying gene expression levels from individual bacterial cells. Previous published result in single cell gene expression quantification mainly used a fluorescence method; CL detection is limited because of the difficulty to introduce enough D-luciferin molecules. Since dehydration could easily cause proper size holes in bacterial cell membranes and facilitate D-luciferin diffusion, we used this method and recorded CL from individual cells each hour after induction. The CL light intensity from each individual cell was integrated and gene expression levels of two strain types were compared. Based on our calculation, the overall sensitivity of our system is already approaching the single enzyme level. The median enzyme number inside a single bacterium from the higher expression strain after 2 hours induction was quantified to be about 550 molecules. Finally we imaged ATP release from astrocyte cells. Upon mechanical stimulation, astrocyte cells respond by increasing intracellular Ca 2+ level and releasing ATP to extracellular spaces as signaling molecules. The ATP release imaged by direct CL imaging using free firefly luciferase and D-luciferin outside cells reflects the transient release as well as rapid ATP diffusion. Therefore ATP release detection at the cell surface is critical to study the ATP release mechanism and signaling propagation pathway. We realized this cell surface localized ATP release imaging detection by immobilizing firefly luciferase to streptavidin beads that attached to the cell surface via streptavidin-biotin interactions. Both intracellular Ca 2+ propagation wave and extracellular ATP propagation wave at the cell surface were recorded with fluorescence and CL respectively. The results imply that at close distances from the stimulation center (<120 μm) extracellular ATP pathway is faster, while at long distances (>120 μm) intracellular Ca 2+ signaling through gap junctions seems more effective.

59 BASIC BIOLOGICAL SCIENCES↗

Antenna Measurements: Test & Analysis of the Radiated Emissions/Immunity of the NASA/Orion Spacecraft Dart Parachute Simulator & Prototype Capsule - The Crew Exploration Vehicle

For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) ~ (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30◦ angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit, and far-field hybrid antenna measurements at 3m are being extrapolated inward to the 1m distance for similar comparisons.

Norgard, John D.↗

Antenna Measurements: Test & Analysis of the Radiated Emissions from the NASA/Orion Spacecraft - Parachute System Simulator

For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of landing parameters and parachute loads. The avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. To verify Electromagnetic Compatibility (EMC) of the CPAS system from unintentional radiation, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC at 1m from the electronic components of the CPAS system. In addition, EMI measurements of the integrated CPAS system are being made inside a hanger at YPG. These near-field B-Dot probe measurements on the surface of a parachute simulator (DART) are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit.

Norgard, John D.↗

X-ray Pinhole Camera Measurements

The development of the rod pinch diode [1] has led to high-resolution radiography for dynamic events such as explosive tests. Rod pinch diodes use a small diameter anode rod, which extends through the aperture of a cathode plate. Electrons borne off the aperture surface can self-insulate and pinch onto the tip of the rod, creating an intense, small x-ray source (Primary Pinch). This source has been utilized as the main diagnostic on numerous experiments that include high-value, single-shot events. In such applications there is an emphasis on machine reliability, x-ray reproducibility, and x-ray quality [2]. In tests with the baseline rod pinch diode, we have observed that an additional pinch (Secondary Pinch) occurs at the interface near the anode rod and the rod holder. This suggests that stray electrons exist that are not associated with the Primary Pinch. In this paper we present measurements on both pinches using an x-ray pinhole camera. The camera is placed downstream of the Primary Pinch at an angle of 60° with respect to the diode centerline. This diagnostic will be employed to diagnose x-ray reproducibility and quality. In addition, we will investigate the performance of hybrid diodes relating to the formation of the Primary and Secondary Pinches.

X-RAY, pinhole, camera, measurements, rod pinch di↗

Multiframe point-projection radiography imaging based on hybrid X-pinch

This paper demonstrates the possibility of using a new configuration of the hybrid X-pinch to produce a set of spatially and temporarily separate x-ray bursts that could be used for the radiography of dynamic events. To achieve this, a longer than normal wire is placed between the conical electrodes of the hybrid X-pinch, and a set of small spacers (fishing weights) is placed along the wire. Each subsection of the wire then acts as a unique X-pinch, producing its own radiation burst from a small (~3 µm) spot. The timing between bursts is 20–50 ns, and each is <2 ns in duration. For comparison, if a longer wire is simply employed without spacers, hotspots of radiation occur in random positions and the time between any two bursts does not exceed 20 ns. Examples of two and three frame point-projection radiography of solid-state and plasma test objects are given.

47 OTHER INSTRUMENTATION↗

High speed infrared camera diagnostic for heat flux measurement in NSTX

A new high speed infrared camera has been successfully implemented and produced first set of heat flux measurements on the lower divertor tiles in the NSTX tokamak. High spatial and temporal resolutions, 6.4 mm and 1.6-6.3 kHz, respectively, enable us to investigate detailed structure of heat flux deposition pattern caused by transient events such as edge localized modes. A comparison of the data with a slow infrared camera viewing the same region of interest shows good agreement between the two independent measurements. Data analysis for various plasma conditions is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Curated Dataset of Regional Meteor Events with Simultaneous Optical and Infrasound Observations (2006–2011)

We present a curated, openly accessible dataset of 71 regional meteor events simultaneously recorded by optical and infrasound instrumentation between 2006 and 2011. These events were captured during an observational campaign using the all-sky cameras of the Southern Ontario Meteor Network and the co-located Elginfield Infrasound Array. Each entry provides optical trajectory measurements, infrasound waveforms, and atmospheric specification profiles. The integration of optical and acoustic data enables robust linkage between observed acoustic signals and specific points along meteor trajectories, offering new opportunities to examine shock wave generation, propagation, and energy deposition processes. This release fills a critical observational gap by providing the first validated, openly accessible archive of simultaneous optical–infrasound meteor observations that supports trajectory reconstruction, acoustic propagation modeling, and energy deposition analyses. By making these data openly available in a structured format, this work establishes a durable reference resource that advances reproducibility, fosters cross-disciplinary research, and underpins future developments in meteor physics, atmospheric acoustics, and planetary defense.

astrometry↗

Advances in Entry Modeling for Impact Risk Assessment

A summary of recent advancements in the detailed modeling of asteroid atmospheric entry processes made through NASA’s Asteroid Threat Assessment Project (ATAP) is presented. Understanding, and accurately modeling these processes and their associated uncertainties is critical to predicting all downstream impact effects, such as blast wave and thermal damage footprints. Furthermore, there is (perhaps thankfully) a dearth of empirical data for large impactors of the kind that would pose a threat to human populations, on which to anchor and/or validate models used in risk assessments. Therefore, we must rely heavily on detailed theoretical and numerical modeling to develop robust assessments for decision makers. To that end, ATAP has made some significant progress in advancing the capabilities in this area. Two areas in particular are highlighted in the present work: meteoroid ablation mechanisms, and bolide luminosity. The first research area – meteoroid ablation mechanisms – has focused on performing novel high-enthalpy wind tunnel experiments on meteorites and meteorite analogs, and utilizing the resulting data to develop high-fidelity models for impactor mass loss at scale. These efforts have resulted in several insights. Of note, these data suggest a differential vaporization process where volatiles are liberated preferentially when the asteroidal material is subject to high heat, while refractory components remain in the molten layer on the surface. A numerical model has been developed which considers this phenomena, and its effect on the bulk impactors effective heat of ablation is examined. The second research thrust that is discussed is focused on accurate modeling of impactor radiation phenomena. While another submission to the conference will discuss the application of our approach to thermal ground damage modeling, here, we present an overview of our extensive efforts to utilize available ground- and space-based observations of large bolides (~1m diameter, and above) to inform and validate our detailed modeling approaches. These methods have been shown to accurately reconstruct the detailed spectra for the Benesov bolide, as well as approximate the burn footprint for the Tunguska event. Recent effort has focused on reconciling light curve data from multiple sources (all-sky camera networks, GLM, US government sensors), using our validated model, and providing a calibrated model for luminous efficiency which can then be utilized to infer impactor properties such as shape, mass, and composition. This work will be demonstrated through an exemplar case study focusing on a large bolide event with observational data (e.g. Chelyabinsk, Flensburg, etc.). Finally, our team’s assessment on the current maturity of atmospheric entry models, and priorities for future research will be provided.

ATAP↗

Analysis of Ground-Based Observations of TLES From Spritacular Project Database

Spritacular is a citizen science project that was launched in October of 2022. It provides a space for anyone to submit their transient luminous event (TLE) images along with observational information, i.e. time, geographic location, direction, camera setup. Along with submissions, one can also help identify different types of TLEs in the images submitted. Since its inception hundreds of images have been submitted to the project database by its users. Not only does the database itself provide a record of observations, but these submissions allow for scientists with access to a wider array of observational platforms to obtain a better understanding of TLE’s without having to chase or hunt for them. Citizen science databases come with pros and cons when dealing with observational science and trying to work across different platforms. Using this database, over one hundred sprites were found to have accurate pointing and adequate temporal resolution to attempt to match both ground based (National Lightning Detection Network [NLDN]) and satellite based (Geostationary Lightning Mapper [GLM]) sensors. A statistical analysis of these TLE properties as well as a discussion about the implications these measurements have on the hunt for TLEs both in current space based observational platforms such as the Atmosphere-Space Interaction Monitor (ASIM), International Space Station Lightning Imaging Sensor (ISS-LIS), and GLM or legacy satellite instruments such as the Lightning Imaging Sensor (LIS) on the Tropical Rainfall Measuring Mission (TRMM) satellite will be presented.

T. Daniel Walker↗