Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosion Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Predicting the performance of local seismic networks using Matlab and Google Earth.

We have used Matlab and Google Earth to construct a prototype application for modeling the performance of local seismic networks for monitoring small, contained explosions. Published equations based on refraction experiments provide estimates of peak ground velocities as a function of event distance and charge weight. Matlab routines implement these relations to calculate the amplitudes across a network of stations from sources distributed over a geographic grid. The amplitudes are then compared to ambient noise levels at the stations, and scaled to determine the smallest yield that could be detected at each source location by a specified minimum number of stations. We use Google Earth as the primary user interface, both for positioning the stations of a hypothetical local network, and for displaying the resulting detection threshold contours.

99 GENERAL AND MISCELLANEOUS↗

Peer Review of "Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions," Antoun, et al, 2011 Monitoring Research Review

The following is primarily a review of 'Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions,' Antoun, et al, published by Lawrence Livermore National Laboratory (LLNL) after SPE-1 in 2011 (Ref. 1). However, LLNL analysis of SPE-2 (Ref. 2) will also be discussed. A review by Los Alamos National Laboratory (LANL) personnel of Reference 1 finds both the evidence of the effects of joints on the data and the correlation of calculations with the data weak. This conclusion is made on three separate levels: (1) Fundamental observations made of the various referenced figures taken as presented; (2) Observations made following corrections to errors and omissions to the selected data; and (3) Observations made after considering likely errors in the raw data set. The evidence presented in the referenced papers relies on subjective interpretation of various figures. This is the nature of this technical field of study and, indeed, much of our observation is also subjective.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Explosives mimic for testing, training, and monitoring

Additive Manufacturing (AM) is used to make mimics for explosives. The process uses mixtures of explosives and matrices commonly used in AM. The explosives are formulated into a mixture with the matrix and printed using AM techniques and equipment. The explosive concentrations are kept less than 10% by wt. of the mixture to conform to requirements of shipping and handling.

36 MATERIALS SCIENCE↗

Explosive Byproduct Gas Transport Through Sorptive Geomedia

Current underground nuclear explosion (UNE) detection strategies rely heavily on atmospheric noble gas sampling of radioxenon. However, discriminating nuclear weapons testing programs from civilian sources is difficult due to highly variable atmospheric radioxenon backgrounds and processes affecting subsurface transport of parent radionuclides. Here, we aim to study the transport of gases produced by subsurface explosions as novel stable signatures for underground nuclear explosion (UNE) monitoring. These gases may be produced in large quantities with distinct molecular ratios, which will be impacted by subsurface transport processes. To demonstrate how ratios of gases produced by explosions can change during transport in geomaterials, we conducted laboratory benchtop experiments on the transport of carbon dioxide (CO 2 ) and hydrogen (H 2 ) gases through variably saturated zeolitic tuff, which is abundant at the historic US testing site. We observed that zeolitic tuff sorbs substantial quantities of CO 2 while allowing H 2 to transport more freely, leading to changes in the molecular ratios of the two gases along the transport pathway. Gas uptake in the dry zeolitic tuff core was 72.3% for CO 2 , compared with 53.4% for xenon and 7.6% for H 2 . The presence of 20% water saturation disrupted the CO 2 sorption process, though to a lesser extent than observed for noble gases, with a 36.7% drop in xenon sorption compared with a 21.9% drop for CO 2 . These results represent the first observations of zeolite sorption altering explosive gas ratios during transport through geomedia relevant to nuclear proliferation monitoring.

54 ENVIRONMENTAL SCIENCES↗

Value of Information Analysis Project Gnome Site, New Mexico

The Project Gnome site in southeastern New Mexico was the location of an underground nuclear detonation in 1961 and a hydrologic tracer test using radionuclides in 1963. The tracer test is recognized as having greater radionuclide migration potential than the nuclear test because the tracer test radionuclides (tritium, 90Sr, 131I, and 137Cs) are in direct contact with the Culebra Dolomite aquifer, whereas the nuclear test is within a bedded salt formation. The tracer test is the topic here. Recognizing previous analyses of the fate of the Gnome tracer test contaminants (Pohll and Pohlmann, 1996; Pohlmann and Andricevic, 1994), and the existence of a large body of relevant investigations and analyses associated with the nearby Waste Isolation Pilot Plant (WIPP) site (summarized in US DOE, 2009), the Gnome Site Characterization Work Plan (U.S. DOE, 2002) called for a Data Decision Analysis to determine whether or not additional characterization data are needed prior to evaluating existing subsurface intrusion restrictions and determining long-term monitoring for the tracer test. Specifically, the Work Plan called for the analysis to weigh the potential reduction in uncertainty from additional data collection against the cost of such field efforts.

54 ENVIRONMENTAL SCIENCES↗

Threshold magnitudes for a multichannel correlation detector in background seismicity

Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannel waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.

54 ENVIRONMENTAL SCIENCES↗

An Overview of the Source Physics Experiment at the Nevada National Security Site (SPE-N)

Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. The Source Physics Experiment at the Nevada National Security Site (SPE-N) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green’s function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1-N was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2-N was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3-N was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability.

Source record↗

A radioxenon detection system using PIPS and CZT

This paper introduces and describes the initial characterizations of a prototype beta gamma coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for atmospheric radioxenon identification and nuclear test ban treaty verification. Coincidences between four independent detecting bodies are identified in real time via a custom coincidence module implemented in a field-programmable gate array (FPGA). The system is compact, maintains simple readout electronics, and provides high resolution radiation detection at room temperature operation. Preliminary measurements using 137 Cs and 131m Xe were conducted to optimize various system parameters to achieve optimal energy resolution of key spectral features. The purpose of this research was to explore the utility of these materials and methods for radioxenon monitoring in the International Monitoring System (IMS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Statistical Framework for Operational lnfrasound Monitoring [Slides]

Historically, much infrasound research has been event-based, with known events providing the ground-truth required to inform the search for associated signals. For monitoring nuclear explosions in the atmosphere or underground, reliable techniques are required for operational infrasound data processing that effectively minimize both false alarms and missed detections. A difficulty in working with infrasound data is to adequately account for dynamic variations in the atmosphere, which occur over a variety of temporal and spatial scales. However, contrary to one's intuition, it is not necessary to have a high fidelity atmospheric model in order to perform robust detection, association and location. We present detection, association and location algorithms that assume no a priori knowledge of the atmosphere; however, where knowledge is available we show how it can be used to reduce the associated uncertainties. Rather than exporting seismic techniques to the problem of infrasound monitoring, our techniques were developed from the ground-up to properly account for the unique considerations of atmospheric acoustics. In contrast with other routinely used infrasound detectors, we utilize a contextual detection hypothesis that adaptively accounts for temporally variable correlated ambient noise. Our location scheme allows for the location of infrasound events without any meteorological data through a Bayesian framework. We demonstrate the application of the techniques presented here for a series of ground-truth events, and for routine data processing of large amounts of regional infrasound data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development and validation of a software for simulating γ-γ coincidence emission and detection probabilities

Gamma-gamma coincidence spectrometers have the potential to significantly enhance detection sensitivity for ultra-trace radionuclide measurements. The implementation of these spectrometers, however, is limited by the complexity of acquisition hardware, data processing and quantification. This work reports development of a novel radionuclide quantification software for γ-γ coincidence measurements. For any radionuclide, the software parses the Evaluated Nuclear Structure Data File (ENSDF) database, recursively simulating all possible γ-γ coincidence signatures and their respective emission and detection probabilities. Implemented using Python programming language, the software employs several strategies to boost overall computational performance. Since coincidence-based spectrometers are of notable interest in monitoring compliance for the Comprehensive Nuclear-Test-Ban Treaty (CTBT), the software’s execution was tested for 84 CTBT-relevant radionuclides. To date, the software has been experimentally validated for 15 radionuclides using the Advanced Radionuclide Gamma spectrOmeter (ARGO) at Pacific Northwest National Laboratory, USA (PNNL). Notably, the software can be operated in convergence mode, whereby coincidence detection efficiency’s convergence behavior can help avoid unreliable radionuclide activity estimates. With growing number of coincidence spectrometers worldwide, this paper aims to assist the radiation metrology community in developing similar software for their system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Robust Low Noise Seismometer for Nuclear Monitoring

Implementation of the proposed seismometers turned out to be much more challenging than anticipated. The noise levels achieved are indeed well below those ever featured by any electrochemical sensor and just very nearly miss reaching the original objectives. However, while noise-wise the instruments could still prove their usefulness, especially considering their robustness and no-maintenance operation, the implementation of the proposed noise-reduction concept resulted in much larger and heavier devices than originally expected. Moreover, these large dimensions relate only to single-component vertical sensors. While building similar horizontal component is possible, the resulting three-component instrument would be way too large and heavy to be of any practical use. The prototype instruments developed and built retained the inherent advantages of the electrochemical seismometers: no maintenance operation; ability to perform with large installation tilts; and, unfortunately, to a much lesser extent in terms of robustness.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

International challenge to model the long-range transport of radioxenon released from medical isotope production to six Comprehensive Nuclear-Test-Ban Treaty monitoring stations

After performing a first multi-model exercise in 2015 a comprehensive and technically more demanding atmospheric transport modelling challenge was organized in 2016. Release data were provided by the Australian Nuclear Science and Technology Organization radiopharmaceutical facility in Sydney (Australia) for a one month period. Measured samples for the same time frame were gathered from six International Monitoring System stations in the Southern Hemisphere with distances to the source ranging between 680 (Melbourne) and about 17,000 km (Tristan da Cunha). Participants were prompted to work with unit emissions in pre-defined emission intervals (daily, half-daily, 3-hourly and hourly emission segment lengths) and in order to perform a blind test actual emission values were not provided to them. Despite the quite different settings of the two atmospheric transport modelling challenges there is common evidence that for long-range atmospheric transport using temporally highly resolved emissions and highly space-resolved meteorological input fields has no significant advantage compared to using lower resolved ones. As well an uncertainty of up to 20% in the daily stack emission data turns out to be acceptable for the purpose of a study like this. Model performance at individual stations is quite diverse depending largely on successfully capturing boundary layer processes. No single model-meteorology combination performs best for all stations. Moreover, the stations statistics do not depend on the distance between the source and the individual stations. Finally, it became more evident how future exercises need to be designed. Set-up parameters like the meteorological driver or the output grid resolution should be pre-scribed in order to enhance diversity as well as comparability among model runs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A radioxenon detection system using CdZnTe, an array of SiPMs, and a plastic scintillator

This paper presents the design and characterization of a prototype compact beta–gamma radioxenon detection system that utilizes a coplanar CdZnTe crystal, an array of SiPMs, and a plastic scintillator. The detector is directly mounted on a custom PCB. The system provides the advantage of room-temperature operation, while being compact, low noise, and with simple readout electronics. Preliminary measurements using 137 Cs, 135 Xe, and 133/133m Xe were conducted to optimize various system parameters to achieve optimal resolution of key photopeaks. The purpose of this research was to explore the potential of these radiation detection elements for use in beta–gamma coincidence applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

Carrier gas attenuation in gamma assay of radioactive xenon samples

Gamma attenuation attributable to xenon and carbon dioxide carrier gas in radioactive xenon assay samples has been calculated using Monte Carlo n-Particle (MCNP) transport code for the 0.65 mL flame sealed ampoule (bean), and 15 mL and 50 mL Schlenk tube geometries. The attenuation was correlated as a % loss per standard mL of carrier gas. In this work, high Purity Ge gamma spectroscopy experiments were performed to measure against the MCNP results. The experimental results from the 133 Xe in xenon carrier gas in a bean geometry showed 0.97 ± 0.4% loss per standard mL xenon, which was in agreement with the MCNP predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗