Search NASA⌕ Search

SEARCH · Search NASA

Results for “FILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

Light-induced vibration characteristics of free-standing carbon nanotube films fabricated by vacuum filtration

In this paper, we fabricated carbon nanotube (CNT) films with different thickness by vacuum filtration method, and the films were separated from Mixed Cellulose Ester membranes with burn-off process. The thickness of CNT films with different concentrations of CNTs 50 mg, 100 mg, 150 mg, and 200 mg are 10.36 μm, 20.90 μm, 30.19 μm, and 39.98 μm respectively. The CNT bundles are homogeneously distributed and entangled with each other, and still maintain 2D continuous network structures after burn-off process. The optical absorptivity of the films is between 84% and 99% at wavelengths ranging from 400 nm to 2500 nm. Vibration characteristics were measured with the Fabry-Perot (F-P) interferometer vibration measurement system. CNT films vibrate only under the xenon light irradiating perpendicularly to the surface. Vibration recorded by Fabry-Perot interferometer is considered to be caused by the time-dependent thermal moment, which is due to the temperature differences of two sides of CNT films. The vibration frequency spectrums between 0.1 ∼ 0.5 Hz were obtained by the Fast Fourier Transform spectra from time domain to frequency domain, and showed a linear relationship with films thickness, which is in accordance with theoretical model of thermal induced vibration.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Acousto-optic method of spatial frequency filtration based on diffraction of two eigenmodes of a crystal

A method is proposed for two-dimensional spatial frequency filtration based on acousto-optic (AO) diffraction of two eigenmodes of a crystal on a single acoustic wave. It is shown that AO filters, based on the use of such diffraction, ensure the enhancement of the two-dimensional image edge during its optical Fourier processing. The main theoretical conclusions are experimentally confirmed using an AO paratellurite filter. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Health benefits and costs of filtration interventions that reduce indoor exposure to PM2.5 during wildfires

Increases in hospital admissions and deaths are associated with increases in outdoor air particles during wildfires. This paper estimates the health benefits expected if interventions had improved particle filtration in homes in Southern California during a 10-day period of wildfire smoke exposure. Economic benefits and intervention costs are also estimated. The six interventions implemented in all affected houses are projected to prevent 11% to 63% of the hospital admissions and 7% to 39% of the deaths attributable to wildfire particles. The fraction of the population with an admission attributable to wildfire smoke is small, thus, the costs of interventions in all homes far exceeds the economic benefits of reduced hospital admissions. However, the estimated economic value of the prevented deaths exceed or far exceed intervention costs for interventions that do not use portable air cleaners. For the interventions with portable air cleaner use, mortality-related economic benefits exceed intervention costs as long as the cost of the air cleaners, which have a multi-year life, are not attributed to the short wildfire period. Finally, cost effectiveness is improved by intervening only in the homes of the elderly who experience most of the health effects of particles from wildfires.

54 ENVIRONMENTAL SCIENCES↗

Effectiveness and cost of reducing particle-related mortality with particle filtration

This study evaluates the mortality-related benefits and costs of improvements in particle filtration in U.S. homes and commercial buildings based on models with empirical inputs. The models account for time spent in various environments as well as activity levels and associated breathing rates. The scenarios evaluated include improvements in filter efficiencies in both forced-air heating and cooling systems of homes and heating, ventilating, and air conditioning systems of workplaces as well as use of portable air cleaners in homes. The predicted reductions in mortality range from approximately 0.25 to 2.4 per 10 000 population. The largest reductions in mortality were from interventions with continuously operating portable air cleaners in homes because, given our scenarios, these portable air cleaners with HEPA filters most reduced particle exposures. For some interventions, predicted annual mortality-related economic benefits exceed $1000 per person. Economic benefits always exceed costs with benefit-to-cost ratios ranging from approximately 3.9 to 133. In conclusion, restricting interventions to homes of the elderly further increases the mortality reductions per unit population and the benefit-to-cost ratios.

60 APPLIED LIFE SCIENCES↗

DECONTAMINATION FACTORS AND FILTRATION FLUX IMPACT TO ARP AT REDUCED MST CONCENTRATION

Tank Farm and Closure Engineering is evaluating changes to the Actinide Removal Process facility operations to decrease the MST concentration from 0.4 g/L to 0.2 g/L and the contact time from 12 hours to between 6 and 8 hours. For this evaluation, SRNL reviewed previous datasets investigating the performance of MST at 0.2 g/L in salt solutions ranging from 4.5 to 7.5 M in sodium concentration. In general, reducing the MST concentration from 0.4 to 0.2 g/L and increasing the ionic strength from 4.5 to 7.5 M in sodium concentration will decrease the measured decontamination factors for plutonium, neptunium, uranium and strontium. The decontamination factors as well as single standard deviation values for each sorbate are reported. These values are applicable within the sorbate and sodium concentrations used in the experimental measurements. Decreasing the MST concentration in the ARP from 0.4 g/L to 0.2 g/L will produce an increase in the filter flux, and could lead to longer operating times between filter cleaning. The increase in flux is a function of a number of operating parameters, and is difficult to quantify. However, it is estimated that the reduction in MST could result in a reduction of filtration time of up to 20%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyrolysis Oil Stabilization: Hot-Gas Filtration (CRADA Final Report)

The hypothesis that was tested in this task was that separation of char, with its associated mineral matter from pyrolysis vapors before condensation, will lead to improved oil quality and stability with respect to storage and transportation. The metric used to evaluate stability in this case was a 10-fold reduction in the rate of increase of viscosity as determined by ASTM D445 (the accelerated aging test). The primary unit operation that was investigated for this purpose was hot-gas filtration. A custom-built heated candle filter system was fabricated by the Pall Corporation and furnished to NREL for this test campaign. This system consisted of a candle filter element in a containment vessel surrounded by heating elements on the external surface of the vessel. The filter element and housing were interfaced to NREL’s existing 0.5 MTD pyrolysis Process Development Unit (PDU). For these tests the pyrolysis reactor of the PDU was operated in the entrained-flow mode. The HGF test stand was installed on a slipstream from the PDU so that both hot-gas filtered oil and bio-oil that was not hot-gas filtered could be collected for purposes of comparison. Two filter elements from Pall were tested: 1) porous stainless steel (PSS) sintered metal powder; 2) sintered ceramic powder. An extremely sophisticated bio-oil condensation and collection system was designed and fabricated at NREL and interfaced to the filter unit.

09 BIOMASS FUELS↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bench-Scale Filtration Testing in Support of the Pretreatment Engineering Platform (PEP)

Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP testing program specifies that bench-scale testing is to be performed in support of specific operations, including filtration, caustic leaching, and oxidative leaching.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulated Waste for Leaching and Filtration Studies--Laboratory Preparation Procedure

This report discusses the simulant preparation procedure for producing multi-component simulants for leaching and filtration studies, including development and comparison activities in accordance with the test plan( ) prepared and approved in response to the Test Specification 24590-WTP-TSP-RT-06-006, Rev 0 (Smith 2006). A fundamental premise is that this approach would allow blending of the different components to simulate a wide variety of feeds to be treated in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). For example, a given feed from the planned feed vector could be selected, and the appropriate components would then be blended to achieve a representation of that particular feed. Using the blending of component simulants allows the representation of a much broader spectrum of potential feeds to the Pretreatment Engineering Platform (PEP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗