Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW VELOCITY - DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Velocity Measurements in Channel Gas Flows in the Slip Regime by means of Molecular Tagging Velocimetry

Direct measurements of the slip velocity in rarefied gas flows produced by local thermodynamic non-equilibrium at the wall represent crucial information for the validation of existing theoretical and numerical models. In this work, molecular tagging velocimetry (MTV) by direct phosphorescence is applied to argon and helium flows at low pressures in a 1-mm deep channel. MTV has provided accurate measurements of the molecular displacement of the gas at average pressures of the order of 1 kPa. To the best of our knowledge, this work reports the very first flow visualizations of a gas in a confined domain and in the slip flow regime, with Knudsen numbers up to 0.014. MTV is cross-validated with mass flowrate measurements by the constant volume technique. The two diagnostic methods are applied simultaneously, and the measurements in terms of average velocity at the test section are in good agreement. Moreover, preliminary results of the slip velocity at the wall are computed from the MTV data by means of a reconstruction method

74 ATOMIC AND MOLECULAR PHYSICS↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) because of storm runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work was intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collected air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters were recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station were also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2019. During the FY2019 reporting period, the warmest months were June, July, and August and the coldest were December and February. The highest monthly solar radiation (i.e., sunshine) values were recorded in June, July, and August, whereas December through February had the lowest solar radiation values. Monthly mean wind speeds were highest in the spring (April) and early summer (June). Winds were predominantly from the north, except in February, July, August, and September when winds were mostly from the west. The monthly average relative humidity ranged from 17 percent to approximately 60 percent. Humidity was lowest in the summer and highest in the winter. Monthly total precipitation ranged from 0.0 during August and September to 2.22 inches (in) (56.39 millimeters [mm]) in February. Total precipitation for FY2019 was 7.83 in (198.88 mm). During the reporting period, a single, nonzero, flow event was recorded at the flume. This occurred over two days between March 6 and 7, 2019, in response to 1.16 in (29.46 mm) of precipitation falling within 9.3 hours on March 6, 2019. This event produced a peak water depth of 0.39 in (0.99 centimeters [cm]) in the flume, and runoff was measured for approximately 23.5 hours. However, the maximum recorded flow depth was less than the limit for flow discharge and velocity that can be calculated for the six-inch (15 cm) throat of a Parshall flume. The runoff event produced insufficient flow velocities through the natural channel to cause local erosion and transport of bedload materials. No bedload samples were collected for radiological analysis. Observing meteorological and environmental conditions that lead to storm runoff will help identify the parameters and threshold conditions that should be incorporated into post-closure monitoring plans for this and similar Soils CAU sites. Routine monitoring of meteorological and hydrologic parameters at the Smoky Site CA has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition was completed and the meteorological and runoff monitoring stations were removed from the Smoky Site on October 15, 2019.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Machine Learning Wall Modeling Approaches for Large Eddy Simulation of Gas Turbine Film Cooling Flows: An a Priori Study

Here, in this work, a priori analysis of machine learning (ML) strategies is carried out with the goal of data-driven wall modeling for large eddy simulation (LES) of gas turbine film cooling flows. High-fidelity flow datasets are extracted from wall-resolved LES (WRLES) of flow over a flat plate interacting with the coolant flow supplied by a single row of 7-7-7 shaped cooling holes inclined at 30 degrees with the flat plate at different blowing ratios (BR). The WRLES are performed using the high-order Nek5000 spectral element computational fluid dynamics (CFD) solver. Light gradient boosting machine (LightGBM) is employed as the ML algorithm for the data-driven wall model. Parametric tests are conducted to systematically assess the influence of a wide range of input flow features (velocity components, velocity gradients, pressure gradients, and fluid properties) on the accuracy of ML wall model with respect to prediction of wall shear stress. In addition, the use of spatial stencil and time delay is also explored within the ML wall modeling framework. It is shown that features associated with gradients of the streamwise and spanwise velocity components have a major impact on the prediction fidelity of wall model, while the effect of gradients of wall-normal velocity component is found to be negligible. Moreover, adding flow feature information from an x-y-z spatial stencil significantly improves the ML model accuracy and generalizability compared to just using local flow features from the matching location. Overall, highest prediction accuracy is achieved when both spatial stencil and time delay features are incorporated within the data-driven wall modeling paradigm.

33 ADVANCED PROPULSION SYSTEMS↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adjustments to the law of the wall above an Amazon forest explained by a spectral link

Modification to the law of the wall represented by a dimensionless correction function ϕ RSL (z/h) is derived using atmospheric turbulence measurements collected at two sites in the Amazon in near-neutral stratification, where z is the distance from the forest floor and h is the mean canopy height. The sites are the Amazon Tall Tower Observatory for z/h∈ [1,2.3] and the Green Ocean Amazon (GoAmazon) site for z/h∈ [1,1.4]. Here, a link between the vertical velocity spectrum E ww (k) (k is the longitudinal wavenumber) and ϕ RSL is then established using a co-spectral budget (CSB) model interpreted by the moving-equilibrium hypothesis. The key finding is that ϕ RSL is determined by the ratio of two turbulent viscosities and is given as ν t,BL /ν t,RSL, where ν t,RSL = (1/A)∫$^{∞}_{0}$ τ(k)E ww (k)dk, ν t,BL = k v (z−d)u * , τ(k) is a scale-dependent decorrelation time scale between velocity components, A = C R /(1−C I ) = 4.5 is predicted from the Rotta constant C R = 1.8, and the isotropization of production constant C I = 3/5 given by rapid distortion theory, k v is the von Kármán constant, u * is the friction velocity at the canopy top, and d is the zero-plane displacement. Because the transfer of energy across scales is conserved in E ww (k) and is determined by the turbulent kinetic energy dissipation rate (ε), the CSB model also predicts that ϕ RSL scales with L BL /L d , where L BL is the length scale of attached eddies to z = d, and L d = u$_{*}^{3}$/ε is a macro-scale dissipation length.

54 ENVIRONMENTAL SCIENCES↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

Flow regime and Reynolds number variation effects on the mixing behavior of parallel flows

The hydraulic single-phase mixing of three parallel rectangular channels is experimentally investigated at various Reynolds numbers (Re) and flow regime combinations. Particle Image Velocimetry results for seven mixing cases are presented and discussed with varying Re combinations ranging from 1,824 to 20,844. While all cases result in the same Re ratio of ~0.69 between the inner and outer flows, two cases represent multi-regime mixing with the inner-outer regime pair of laminar-transitional and transitional-turbulent, while the other 5 cases are all characteristic of turbulent mixing with varying levels of turbulence. The outer channels initially share characteristics with a backward facing step. The center channel is found to initially behave like a slot jet, but then sees a significant increase in velocity decay. This inner flow velocity decay increased dramatically in the laminar-transitional mixing case, whose centerline velocity decay was ~6 times larger than the decay in the turbulent mixing cases. Second order statistics revealed a consistent mixing layer thickness of ~0.1 hydraulic diameters for all the cases but showed more intense shearing in the multi-regime mixing cases. The combined point and thereby the mixing layer length is determined using centerline velocity decay profiles, which show a much more aggressive mixing in multi-regime flows. Multi-regime mixing demonstrated superior characteristics relative to turbulent mixing due to a more dramatic velocity decay in the inner flow and a shorter mixing length. The contributions of this work include communicating the benefits of multi-regime mixing and providing detailed characterization efforts that can serve future efforts for validating computational models. Here this research also lays the groundwork for future studies aimed at achieving high levels of mixing without a severe penalty in pressure drop.

42 ENGINEERING↗

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

79 ASTRONOMY AND ASTROPHYSICS↗

Taylor-Couette Flow Modeling (Rev.1)

The Taylor-Couette Flow is a form of viscous flow in which fluid flows between two cylindrical walls with a prescribed rotation. A diagram is shown on the right (Figure 1) where Ω is the rotational velocity, H is the distance between the two cylinders, R is the radius the outer cylinder, r is the radius of the inner cylinder and L is the length of the cylinders. When the rotating inner cylinder reaches a critical velocity, the flow of the liquid becomes unstable and creates vortices in between the layers. In this experiment, the Taylor-Couette cylinders were modeled so that the vortices would be created after reaching a critical velocity. After the initial experiment, the velocity of the inner cylinder was decreased and increased to look at how the results changed.

42 ENGINEERING↗

Force Balance Model Assessment for Mechanistic Prediction of Sliding Bubble Velocity in Vertical Subcooled Boiling Flow

The bubble sliding after departing from nucleation site is frequently observed in flow boiling systems and, the crucial impact on wall heat transfer has been evidenced through many experiments. As a result, the heat transfer modeling associated with sliding bubble has become one of the subjects of great attention in CFD boiling heat transfer community. The modeling efforts are primarily aimed at improving the existing Heat Flux Partitioning (HFP) model via the implementation of sliding bubble-induced heat transfer. The performance of HFP model depends inherently on the fidelity of sub-models used to predict the fundamental bubble parameters (e.g., bubble departure/lift-off diameter). In the same context, the accurate prediction of sliding bubble parameters (e.g., sliding bubble growth, sliding bubble velocity) is essential to achieving the successful heat transfer modeling associated with sliding bubble. Of many sliding bubble parameters, this paper deals with the sliding bubble velocity. Specifically, the force balance model was assessed in view of the sliding bubble velocity prediction. The parametric effect of key sub-models (e.g., drag force, bubble growth models) used in the force balance equation was investigated. The experimental data from Maity (2000) and Yoo et al. (2016) were used for demonstrating the model predictive performance. It was found that the force balance model proposed in this study was able to predict well the bubble sliding velocity based on the accurate prediction of bubble growth during sliding. The predictive performance was proven with the experimental data measured under various subcooled boiling conditions of both water and refrigerant (NOVEC-7000) flowing upward in vertical channels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Symmetry Determining Equations of the Rankine-Hugoniot Equations for Variable Velocity Shock Waves

The “constant velocity piston” problem (Fig. 1), also known as the “piston problem,” is a standard model for a one dimensional, in our case linear, symmetric shock wave moving through an inviscid, perfect gas. The model can be divided into two regions - a perturbed section on the left and an unperturbed section on the right - by a moving shock wave moving left to right. Both the perturbed and unperturbed sections, i.e. the shocked and unshocked regions, respectively, obey the Eulerian conservation equations; however, at the exact location of the shock, there is a mathematical discontinuity not satisfied by the Euler equations. To ensure continuity and conservation of certain quantities when crossing between the unshocked and shocked regions, we evoke a series of equations derived from the Eulerian conservation equations, called the Rankine-Hugoniot equations, or “jump” equations as it is often referred to in the literature on the topic. The classical constant-velocity piston problem assumes the piston features a constant driving velocity (among many other willing suspensions of belief required in the pursuit of a first principles equation model); consequent to this assumption is a constant-velocity shock and a constant-velocity shocked flow state. However, using Lie Group Theory (LGT), also known as symmetry analysis, we can attempt to reinterpret the model with a shock wave of variable velocity in time and space. An extension of the model in this way opens up the possibility for obtaining new analytical solutions to the piston problem for certain shock velocity models. In this report, we use LGT to derive the symmetry determining equations (SDEs), whose solutions are Lie groups, which permit analytical solutions. In the future, we can then use the SDEs to define constraint equations on the shock velocity model and what the successive solutions to the Euler equations might be based off such constraints. This report is structured as follows: Section 2 provides a brief derivation of the Rankine-Hugoniot (“jump”) equations; Section 3 gives an overview of Lie group theory; Section 4 derives the SDEs of the jump equations; Section 5 derives the Euler conservation equations for fluids; and Section 6 presents concluding remarks and opportunities for future studies.

42 ENGINEERING↗

Aluminum-doped calcium manganite particles for solar thermochemical energy storage: Reactor design, particle characterization, and heat and mass transfer modeling

A two-step cycle is discussed for solar thermochemical energy storage based on particulate aluminum-doped calcium manganite reduction/oxidation reactions for direct integration into Air Brayton cycles. The two steps encompass 1) the storage of concentrated solar irradiation within endothermic reduction of aluminum-doped calcium manganite and 2) the delivery of heat to an Air-Brayton cycle via exothermic re-oxidation of oxygen-deficient aluminum-doped calcium magnanite. A 5 kW th scale solar thermochemical reactor operating under vacuum was designed, modeled, and optimized to thermally reduce a continuous, gravity-driven flow of aluminum-doped calcium manganite particles. The granular flows were characterized in a tilt-flow rig, and particle image velocimetry was used to determine flow properties via frictional and velocity scaling relationships. Flow properties were integrated into a detailed heat and mass transfer model of the solar thermochemical reactor. A reactor design with 31° inclination angle, 230 g/min of particles, and 5.2 kW th radiative input from the high-flux solar simulator was discovered to produce an outlet flow temperature of 1158 K, with stoichiometric deviations of 0.076 and a storage efficiency of 0.628 while avoiding particle overheating and promoting longer particle residence times.

14 SOLAR ENERGY↗

Coupling between Alfven wave and Kelvin-Helmholtz waves in the low latitude boundary layer

The Kelvin-Helmholtz (KH) instability of magnetohydrodynamic surface waves at the low latitude boundary layer is examined using both an eigenfrequency analysis and a time-dependent wave simulation. The analysis includes the effects of sheared flow and Alfven velocity gradient. When the magnetosheath flows are perpendicular to the ambient magnetic field direction, unstable KH waves that propagate obliquely to the sheared flow direction occur at the sheared flow surface when the Alfv\'en Mach number is higher than an instability threshold. Including a shear transition layer between the magnetosphere and magnetosheath leads to secondary KH waves (driven by the sheared flow) that are coupled to the resonant surface Alfven wave. There are remarkable differences between the primary and the secondary KH waves including wave frequency, the growth rate, and the ratio between transverse and the compressional component. The secondary KH wave energy is concentrated near the shear Alfven wave frequency at the magnetosheath with a lower frequency than the primary KH waves. Although the growth rate of the secondary KH waves is lower than the primary KH waves, the threshold condition is lower, so it is expected that these types of waves will dominate at lower Mach number. Because the transverse component of the secondary KH waves is stronger than the primary KH waves, more efficient wave energy transfer from the boundary layer to the inner magnetosphere is also predicted.

Alfven wave↗