Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOULING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Impact Of Sodium Oxalate, Sodium Aluminosilicate, and Gibbsite/Boehmite on ARP Filter Performance

The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. SRR requested SRNL to conduct bench-scale filter tests to evaluate whether sodium oxalate, sodium aluminosilicate, or aluminum solids (i.e., gibbsite and boehmite) could be the cause of excessive fouling of the crossflow or secondary filter at ARP. The authors conducted the tests by preparing slurries containing 6.6 M sodium Salt Batch 6 supernate, 2.5 g MST/L slurry, and varying concentrations of sodium oxalate, sodium aluminosilicate, and aluminum solids, processing the slurry through a bench-scale filter unit that contains a crossflow primary filter and a dead-end secondary filter, and measuring filter flux and transmembrane pressure as a function of time. Among the conclusions drwn from this work are the following: (1) All of the tests showed some evidence of fouling the secondary filter. This fouling could be from fine particles passing through the crossflow filter. (2) The sodium oxalate-containing feeds behaved differently from the sodium aluminosilicate- and gibbsite/boehmite-containing feeds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TESTING OF THE SPINTEK ROTARY MICROFILTER USING ACTUAL HANFORD WASTE SAMPLES

The SpinTek rotary microfilter was tested on actual Hanford tank waste. The samples were a composite of archived Tank 241-AN-105 material and a sample representing single-shell tanks (SST). Simulants of the two samples have been used in non-rad test runs at the 222-S laboratory and at Savannah River National Laboratory (SRNL). The results of these studies are compared in this report. Two different nominal pore sizes for the sintered steel rotating disk filter were chosen: 0.5 and 0.1 {micro}m. The results suggest that the 0.5-{micro}m disk is preferable for Hanford tank waste for the following reasons: (1) The filtrate clarity is within the same range (<<4 ntu for both disks); (2) The filtrate flux is in general higher for the 0.5-{micro}m disk; and (3) The 0.1-{micro}m disk showed a higher likelihood of fouling. The filtrate flux of the actual tank samples is generally in the range of 20-30% compared to the equivalent non-rad tests. The AN-105 slurries performed at about twice the filtrate flux of the SST slurries. The reason for this difference has not been identified. Particle size distributions in both cases are very similar; comparison of the chemical composition is not conclusive. The sole hint towards what material was stuck in the filter pore holes came from the analysis of the dried flakes from the surface of the fouled 0.1-{micro}m disk. A cleaning approach developed by SRNL personnel to deal with fouled disks has been found adaptable when using actual Hanford samples. The use of 1 M nitric acid improved the filtrate flux by approximately two times; using the same simulants as in the non-rad test runs showed that the filtrate flux was restored to 1/2 of its original amount.

36 MATERIALS SCIENCE↗

Characterization and Well Remediation Strategies for Improved Long-term Pump and Treat System Injection Well Performance - 17272

In June of 2012 the CH2M Hill Plateau Remediation Company completed construction of a 2,500 gallon-per-minute (gpm) pump and treat (P and T) system designed to remove technetium-99, uranium, carbon tetrachloride, trichloroethene, nitrate, and total and hexavalent chromium from incoming groundwater. The entire pump and treat system consists of the following primary components: 1) extraction wells (20+); 2) a radionuclide removal facility; 3) a biological system; 4) sludge processing; 5) vapor processing; and 6) injection wells. Overall efficiency of the 200 West P and T has been adversely impacted due to fouling in vertical injection wells where treated water is being reinjected into the subsurface. Fouling of the wells is thought to be caused by bacteria producing extracellular polymeric substances (EPS), as well as high manganese and iron in the biofilm. Due to decreased specific injectivity, all injection wells are on a maintenance schedule requiring rehabilitation. During rehabilitation, the wells are out of service affecting the overall capacity of the P and T, plus the rehabilitation process adds hundreds of thousands of dollars of cost to operate the P and T each year. Chemical and biological foulants may be coming from the P and T or are already present in the subsurface and active pumping has stimulated growth of the microbes present. Chemical and microbiological characterization efforts are in progress for the biological plant and injection well system to determine causative agents in the biofouling. P and T effluent tank samples, injection well distribution tanks, bailed samples from the fouled well, and post-rehabilitation samples were analyzed. Chemical constituents analyzed include, sulfate, phosphorus, chemical oxygen demand, total organic carbon, and iron. Microbial characterization included total heterotrophs, anaerobic heterotrophs, nitrate reducing bacteria, iron reducing bacteria and sulfate reducing bacteria. Molecular biological tools employed included 16S rRNA meta-genomes, and functional gene analysis using qPCR. Chemical analysis of the P and T effluent and injection well tanks showed the presence of ∼6.5 mg/L nitrate, 96 mg/L sulfate and phosphorus levels below 1 mg/L. Bailed samples from the injection well showed similar concentrations for each chemical, but following cleaning, TOC, total iron, manganese and other constituents were higher than prior to cleaning. These data show that bacterial nutrients and metals that may precipitate are present in the well water and are likely the causative agent in the biofouling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finding balance between biological groundwater treatment and treated injection water - 15237

At the U.S. Department of Energy's Hanford Site, CH2M HILL Plateau Remediation Company operates the 200 West Pump and Treat which was engineered to treat radiological and chemical contaminants in groundwater as a result of the site's former plutonium production years. Fluidized bed bioreactors (FBRs) are used to remove nitrate, metals, and volatile organic compounds. Increasing nitrate concentrations in the treatment plant effluent and the presence of a slimy biomass (a typical microorganism response to stress) in the FBRs triggered an investigation of nutrient levels in the system. Little, if any, micro-nutrient feed was coming into the bioreactors. Additionally, carbon substrate (used to promote biological growth) was passing through to the injection wells, causing biological fouling of the wells and reduced specific injectivity. Adjustments to the micro-nutrient feed improved microorganism health, but the micro-nutrients were being overfed (particularly manganese) plugging the injection wells further. Injection well rehabilitation to restore specific injectivity required repeated treatments to remove the biological fouling and precipitated metal oxides. A combination of sulfamic and citric acids worked well to dissolve metal oxides and sodium hypochlorite effectively removed the biological growth. Intensive surging and development techniques successfully removed clogging material from the injection wells. Ultimately, the investigation and nutrient adjustments took months to restore proper balance to the microbial system and over a year to stabilize injection well capacities. Carefully tracking and managing the FBRs and well performance monitoring are critical to balancing the needs of the treatment system while reducing fouling mechanisms in the injection wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined chlorine dioxide–membrane distillation for the treatment of produced water

Membrane distillation (MD) is a promising technique for desalinating hypersaline brine, such as produced water (PW). To date, fouling and scaling have remained as major challenges for MD implementation. In this study, chlorine dioxide combined with induced air floatation (ClO 2 -IAF) was systematically investigated as a pretreatment prior to MD. First, the ClO 2 generation based on sodium chlorite and hydrochloric acid was optimized to maximize the on-demand ClO 2 production. The maximum production yield of 18.4% was obtained with 4wt.% NaClO 2 and 20wt.% HCl solutions, with a molar ratio of 1:1.25. Then, two real PW samples were pretreated, and removal efficiencies for total suspended solids (TSS), turbidity, iron, and total organic carbon (TOC) were comprehensively studied by varying the ClO 2 dosage between 6 and 91 mg/L. The ClO 2 -IAF pretreatment displayed TSS and turbidity removals above 90% and TOC removal close to 55%. Further, the PW constituents such as benzene, toluene, ethylbenzene, xylene (BTEX), and total petroleum hydrocarbons (TPH) were analyzed and quantified throughout the cascade of the treatments. The volatiles like BTEX were mainly removed by air floatation, while saturated hydrocarbons such as TPH were retained by the hydrophobic membrane. The MD long-term stability without any in-place cleaning was evaluated, and the membrane withstood for twenty two days without wetting, suggesting that optimizing oxidation pretreatment is critical for mitigating the fouling in MD. Results suggest that organic fouling in PW could be effectively reduced by the pretreatment, but further treatment is required to mitigate the scaling, which resulted in MD wetting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗

Protein Adhesion on Semi-Fluorinated Polystyrene Surfaces in Static and Dynamic Measurements

Reducing protein adhesion is a critical strategy in fouling-resistant material innovation, with broad applications spanning biomedical and healthcare devices, biosensors, industrial and environmental systems, and other important technological domains. Here, in this study, we elucidated protein adhesion behavior on polystyrene-based thin films by neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D), using both lysozyme and bovine serum albumin (BSA) as model proteins. To this end, semifluorinated polystyrene thin films with gradient wettability and surface energy were fabricated through dry processing using plasma oxidation and gas-phase deposition. Although it is believed that a fully fluorinated alkyl chain offers extremely low surface energy, thus rejecting foulants, and has been used in many fouling-resistant surface designs, enhanced protein–surface interactions were observed consistently in NR and QCM-D results, due to the combined effects of surface morphology and chemistry. On the contrary, depositing shorter fluorinated silane onto a hydrophilic PS surface contributed to a more homogeneous nanoscale fluorine coating, resulting in less initial protein adsorption and improved surface recovery. Comparative analysis of proteins with different sizes on the nanopatterned semifluorinated surface revealed the influence of molecular characteristics on surface interactions. Lysozyme, being smaller and more compact, showed faster adsorption kinetics and higher surface coverage but largely reversible binding, whereas BSA, with its larger and more flexible structure, formed broader and more stable interfacial layers. This study fills the gap in understanding protein adhesion within the range of hydrophobicity (water contact angle ∼90°), as current strategies often associate with extreme hydrophilic and superhydrophobic surfaces due to hydration or low-surface-energy rejection mechanisms, respectively. It also provides in-depth insights into current combinatorial fouling-resistant surface design.

Yuan, Yue [Oak Ridge National Laboratory (ORNL), O↗

MPCVD-Grown Nanodiamond Microelectrodes with Oxygen Plasma Activation for Neurochemical Applications

Nanodiamonds (NDs) are a carbon nanomaterial that has a diamond core with heteroatoms and defects at the surface. The large surface area, defect sites, and functional groups on NDs make them a promising material for electrochemical sensing. Previously, we dip-coated ND onto carbon-fiber microelectrodes (CFMEs) and found increases in sensitivity, but the coating was sparse. Here, for this work, we directly grew thin films of ND on niobium wires using microwave plasma chemical vapor deposition (MP-CVD) to provide full surface coverage. ND microelectrodes show a reliable performance in neurotransmitter detection with good antifouling properties. To improve sensitivity, we oxygen plasma etched ND films to activate the surface and intentionally add defects and oxygen surface functional groups. For fast-scan cyclic voltammetry detection of dopamine, oxygen plasma-etching increases the sensitivity from 21 nA/μM to 90 nA/μM after treatment. Fouling was tested by repeated injections of serotonin or tyramine, and both ND and plasma oxidized nanodiamond (NDO) microelectrodes maintain their currents better compared to CFMEs and therefore are more antifouling. Furthermore, a biofouling test in brain slices shows that ND microelectrodes barely have any current drop, while the more hydrophilic NDO microelectrodes decrease more, but still not as much as CFMEs. Overall, grown ND microelectrodes are promising in neurotransmitter detection with excellent fouling resistance, whereas oxygen plasma etching slightly lowers the fouling resistance but dramatically increases sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Media comparison of filtration with Hanford tank AP-107 supernate

The present experimental work was performed in order to investigate media performance in both cross-flow and dead-end filtration on 9 L of Hanford tank AP-107 supernatant. Media grades 0.1 and 5 were tested for each the cross-flow filter (CFF) and dead-end filter (DEF). The CFFs were tested in the cells unit filter (CUF) system in recycle mode and the DEFs (in-line and disc) were used to dewater the feed. Visual inspection of the feed material indicated essentially no settled insoluble solids in the feed material. The 5 micron grade cross flow filter produced stable filter fluxes while the flux for the 0.1 micron grade material steadily decayed. The 5 media grade BDEF (backpulsed dead-end filter) was effective at removing solids from the AP-107 feed and when backpulsed, fully restored the filter flux, indicating that the solids did not irreversibly foul the filter. The 0.1 media grade DEF was used to filter the final 2 liters of AP-107 feed drained from the CUF and collect solids on the filter media. Additional DEF filtering was performed on 4 L of BDEF permeate in order to assess whether small particles that cause fouling in the 0.1 media grade filter passed through the 5 media grade filter. There was no indication of fouling and limited solids were observed on the filter. In conclusion, a direct comparison of filtration rates between the 0.1 and 5 media grade filters for both the CFF and DEF showed the 5 media grade filter flux was, on average, 200 times higher than the 0.1 media grade filter while still effectively filtering the solids.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Slippery Omniphobic Covalently Attached Liquids for Extreme Anti-Scaling

Fouling is amajor unresolved problem in a varietyof industries including power generation, water desalination,and hydrometallurgy. In a heat exchanger, the accumulated salt scale could lead to a decrease in heat transfer, corrosion, blockage of flow and increasedpressure drop, resulting in higher operation costsand shortened equipment lifetime. The added operational costs due to active scale removal techniques such as mechanical abrasion and chemical inhibitors are responsible for 0.25% of the GDP in industrialized nations.Herewe utilize slippery omniphobic covalently attached liquids (SOCAL) dip coating on aluminum substrates to minimize surface energyand surface roughness, hence maximizingthe energy barrier for scale formation. To enable SOCAL surfacebinding on aluminum, we started by depositinga nanoscale(500 nm thick)adhesion layer of SiO2using scalable and cost-effective electrophoretic deposition (EPD), followed by SOCAL grafting to the SiO2.The EPD SiO2coating chemistry was tailored to achieve a smoothsurface finish which, combined with the low surface energyof the SOCAL coating, translated to extreme anti-scaling performance. Thermal degradation testing in an ambient environment revealed the covalently bonded SOCAL coatingswithstand temperatures of 100°C. To characterize scaling, we utilized CaSO4and CaCO3scale tests, showing up to 20X less scaling than uncoated aluminum. Descaling tests revealed that our SOCAL coatings dramatically decrease scale adhesion, resulting in rapid removal of scale buildup in highly supersaturated conditions. To investigate manufacturability, two alternate methods of SiO2deposition were tested, including physical vapor deposition and spin-on glass, with great success in coating smooth metallic substrates, but limited success due to the inability to coat arbitrarily shaped surfaces. Our work not only demonstrates a facile method of tailoring interfacial energy and roughness to control fouling, it develops cost-effective, scalable,and high performing anti-fouling coating applicable to aluminum surfacesfor a variety of applications.

Zhao, Hanyang↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

TEAMER Technical Support on Biofouling and Corrosion for E-Wave Technologies LLC Novel (Abstract)

National Technology & Engineering Solutions of Sandia (NTESS) in collaboration with the Pacific Northwest National Laboratory (PNNL), and with guidance from E-Wave, will assess corrosion and biofouling challenges specific to E-Wave’s innovative WEC designed to retrofit into and power existing aquaculture farm infrastructure from ocean waves. The teams will examine coatings via a static raw seawater test and determine the efficacy of coatings for E-Wave’s applications. Samples will include panels of materials provided by E-Wave and coated with three different paint treatments. Fouling will be determined using a staining technique followed by photographic analysis to evaluate fouling intensity on the surface. Materials will also be weighed before and after submersion to facilitate weight change analysis resulting from fouling organisms aggregating on the materials.

16 TIDAL AND WAVE POWER↗

Water vapor diffusion membrane development

A total of 18 different membranes were procured, characterized, and tested in a modified bench-scale vapor diffusion water reclamation unit. Four membranes were selected for further studies involving membrane fouling. Emphasis was placed on the problem of flux decline due to membrane fouling. This is discussed in greater details under "Summary and Discussion on Membrane Fouling Studies" presented in pages 47-51. The system was also investigated for low temperature application on wash-water where the permeated water is not recovered but vented into space vacuum.

Tan, M. K.↗

Design optimization of a brush turbine with a cleaner/water based solution

Recently, a fluid turbine which has a brush attached to it has been designed and tested with water as fluid. The purpose of the turbine-brush is to clean up fouling in a tube. The Montreal Protocol prohibits the use of CFC products from refrigeration industry or from industry in general as a cleanser in 1996. Alternatives for the cleansers, devices or a combination of alternative devices with a cleanser should be found. One of the methods is to develop a device which cleans fouling with a cleaning medium. In this paper, we describe a turbine connected with a brush. However, the turbine with the brush should be simple and easy to install. This device is a combined small liquid turbine with a brush. The turbine is activated by the liquid flowing through the tube. Then the turbine turns the brush cleaning fouling along the tube. Based on the energy conservation and the Bernoulli equation along with an empirical relationship of drag force obtained from an experimental apparatus, a relationship of the rotational speed, the number of blades, and geometric variables of the turbine-brush was obtained. The predicted rotational speeds were compared with the experimental observations. Further work was recommended for improvements.

Kim, Rhyn H.↗

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from CO2 Project

Oxygen recovery from respiratory CO2 is an important aspect of human spaceflight. Methods exist to sequester the CO2, but production of oxygen needs further development. The current ISS Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction is the only real alternative to the Sabatier reaction, but in the last reaction in the cycle (Boudouard) the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling, find a use for this waste product, and increase efficiency, we propose testing various self-cleaning catalyst designs in an existing MSFC Boudouard reaction test bed and to determine which one is the most reliable in conversion and lack of fouling. Challenges include mechanical reliability of the cleaning method and maintaining high conversion efficiency with lower catalyst surface area. The above chemical reactions are well understood, but planned implementations are novel (TRL 2) and haven't been investigated at any level.

Technology Portfolio System↗

Finding Balance Between Biological Groundwater Treatment and Treated Injection Water

At the U.S. Department of Energy’s Hanford Site, CH2M HILL Plateau Remediation Company operates the 200 West Pump and Treat which was engineered to treat radiological and chemical contaminants in groundwater as a result of the site’s former plutonium production years. Fluidized bed bioreactors (FBRs) are used to remove nitrate, metals, and volatile organic compounds. Increasing nitrate concentrations in the treatment plant effluent and the presence of a slimy biomass (a typical microorganism response to stress) in the FBRs triggered an investigation of nutrient levels in the system. Little, if any, micronutrient feed was coming into the bioreactors. Additionally, carbon substrate (used to promote biological growth) was passing through to the injection wells, causing biological fouling of the wells and reduced specific injectivity. Adjustments to the micronutrient feed improved microorganism health, but the micronutrients were being overfed (particularly manganese) plugging the injection wells further. Injection well rehabilitation to restore specific injectivity required repeated treatments to remove the biological fouling and precipitated metal oxides. A combination of sulfamic and citric acids worked well to dissolve metal oxides and sodium hypochlorite effectively removed the biological growth. Intensive surging and development techniques successfully removed clogging material from the injection wells. Ultimately, the investigation and nutrient adjustments took months to restore proper balance to the microbial system and over a year to stabilize injection well capacities. Carefully tracking and managing the FBRs and well performance monitoring are critical to balancing the needs of the treatment system while reducing fouling mechanisms in the injection wells.

Carlson, Mark A.↗

Complex Microfiltration Behavior of Metal Hydroxide Slurries

Crossflow filtration is to be a key process in the treatment and disposal of approximately 60,000 metric tons of high-level waste stored at the Hanford Site in Richland, Washington. Pacific Northwest National Laboratory is assessing filter performance against waste simulant materials that mimic the chemical and physical properties of Hanford tank waste. Prior simulant studies indicate that waste filtration performance may be limited by pore and cake fouling. To limit the shutdown of waste treatment operations, the pre-treatment facility plans to recover filter flux loses from cake formation and filter fouling by frequently backpulsing the filter elements. The objective of the current research is to develop an understanding of the roles of cake and pore fouling and potential flux recovery through backpulsing of the filters for Hanford waste filtration operations. Metal hydroxide wastes were tested to examine the role of particle-filter interaction on filter performance.

Hanford Site↗