Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development and parametric evaluation of the prototype 2 and 3 flash evaporators

Development of the Prototype 2 and 3 flash evaporator heat sinks which vaporize an expendable fluid to cool a heat transport fluid loop is reported. The units utilize Freon 21 as the heat transport fluid and water as the expendable fluid to meet the projected performance requirements of the space shuttle for both on-orbit and ascent/reentry operations. The evaporant is pulse-sprayed by on-off control onto heat transfer surfaces containing the transport fluid and exhausted to the vacuum environment through fixed area exhaust ducts.

Hixon, C. W.↗

Development of thermal stratification and destratification scaling concepts. Volume 1: Definition of thermal stratification scaling parameters and experimental investigations

The dimensionless parameters associated with the thermal stratification and pressure history of a heated container of liquid and its vapor were examined. The Modified Grashof number, the Fourier number, and an Interface number were parameterized using a single test liquid, Freon 113. Cylindrical test tanks with spherical dome end caps were built. Blanket heaters covered the tanks and thermocouples monitored the temperatures of the liquid, the ullage, the tank walls, and the foam insulation encapsulating the tank. A centrifuge was used for the 6 inch tank to preserve the same scaling parameter values between it and the larger tanks. Tests were conducted over a range of Gr* values and the degree of scaling was checked by comparing the dimensionless pressures and temperatures for each scaled pair of tests. Results indicate that the bulk liquid temperature, the surface temperature of the liquid, and the tank pressure can be scaled with the three dimensionless parameters. Some deviation was, however, found in the detailed temperature profiles between the scaled pairs of tests.

Lovrich, T. N.↗

Measurements of the performance of an electrohydrodynamic heat pipe

The performance of an electrohydrodynamic heat pipe formed by enclosing three straight axial electrodes with a 1.27 cm O.D. internally threaded stainless steel tube was measured with Freon-11 as working fluid. The condenser and evaporator conductances at low power were comparable to those measured in a conventional capillary driven heat pipe using similar working fluids. The evaporator conductance improved at high power probably due to the onset of nucleate boiling. The maximum heat throughput for this pipe was substantially higher than that of a conventional pipe.

Loehrke, R. I.↗

Airborne infrared polarimeter

An infrared polarimeter was built to measure the degree of linear polarization and the direction of vibration of radiation scattered upwards by clouds, between 1.1 and 3.5 microns, with a 1.5-deg field of view, using a rotating wire-grid polarization analyzer. A PbS detector is cooled to 192 K by condensing freon-13. This AEROPOL instrument operates under minicomputer control, giving a polarization least-squares solution every 2.5 s. The polarimeter was flown on the NASA CV-990 aircraft, in a remote-sensing study of terrestrial cloud particle sizes and shapes.

Coffeen, D. L.↗

A 2.2 sq m /24 sq ft/ self-controlled deployable heat pipe radiator - Design and test

An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.

Edelstein, F.↗

Stratospheric ozone - Fragile shield

Atmospheric models that have been used in major studies on the possible impact of SST exhausts and Freons on stratospheric ozone are discussed and compared. An overview is given of ozone-reduction estimates that they produce, together with an assessment of possible effects of atmospheric testing of thermonuclear bombs in an attempt to find direct observational evidence for ozone depletion resulting from human activities. It is concluded that clear validation of atmospheric-model predictions is lacking.

Hoffert, M. I.↗

The thermal system for an environmental chamber

The design of a cooling and heating system for obtaining temperatures in the range of -60 C to +120 C on a thermal shroud is described. The proposed temperature control uses mechanical refrigeration with Freon-22 as the primary refrigerant, methanol as the secondary coolant for low temperatures, and electrically heated ethylene glycol for high temperatures. The system is designed to give the following time-temperature characteristics: lowering the temperature from +30 C to -60 C in 1.5 hours; maintaining the temperature at -60 C for a period of 6 hours; heating from -60 C to +120 C in 3 hours; maintaining the temperature at +120 C for a period of 6 hours; and cooling from +120 C in 1.5 hours. A description of the system and its operation are given.

Srinivasan, K.↗

Study of toxicological evaluation of fire suppressants and extinguishers

The application of fluorocarbons as possible candidates for fire extinguishers and/or suppressants in confined spaces (such as spacecraft, aircraft, or submarines) was investigated, with special emphasis on their safety to man since they would be inhaled on an almost continuous basis. Short-term exposure experiments, using various animal species, were devised to look at specific parameters in order to determine which of the candidate compounds were sufficiently non-toxic to warrant long-term investigations. The following physiologic criteria were examined; tissue distribution, fluoride concentration, effect on mitochondria, microsomes, liposomes, and liver cell nuclei, erythrocyte fragility, clinical chemistry values, hematology, pathology, cardiac sensitization, behavioral effects. Various rodent species were used for initial investigations, with non-human primate exposures for Freon 116 which was warranted for negative results on rodents. Various types of exposure chambers were used, including closed dynamic chambers allowing for a recirculating atmosphere.

Source record↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device for the George C. Marshall Space Flight Center

The development and testing of a temperature sensor and pulse duration modulation (PDM) diverter valve for a thermal control-mixing control device are described. The temperature sensor selected for use uses a fluidic pin amplifier in conjunction with an expansion device. This device can sense changes of less than 0.25 F with greater than 15:1 signal to noise ratio when operating with a typical Freon pump supplied pressure. The pressure sensitivity of the sensor is approximately 0.0019 F/kPa. The valve which was selected was tested and performed with 100% flow diversion. In addition, the valve operates with a flow efficiency of at least 95%, with the possibility of attaining 100% if the vent flow of the PDM can be channeled through the last stage of the diverter valve. A temperature sensor which utilized an orifice bridge circuit and proportional-vortex combination mixing valve were also evaluated, but the concepts were rejected due to various problems.

Thurston, T. S.↗

Validation of scramjet exhaust simulation technique

Scramjet/airframe integration design philosophy for hypersonic aircraft results in configurations having lower aft surfaces that serve as exhaust nozzles. There is a strong coupling between the exhaust plume and the aerodynamics of the vehicle, making accurate simulation of the engine exhaust mandatory. The experimental verification of the simulation procedure is described. The detonation tube simulator was used to produce an exact simulation of the scramjet exhaust for a Mach 8 flight condition. The pressure distributions produced by the exact exhaust flow were then duplicated by a cool mixture Argon and Freon 13B1. Such a substitute gas mixture validated by the detonation tube technique could be used in conventional wind tunnel tests. The results presented show the substitute gas simulation technique to be valid for shockless expansions.

Hopkins, H. B.↗

A Transonic and Surpersonic Investigation of Jet Exhaust Plume Effects on the Afterbody and Base Pressures of a Body of Revolution

An experimental aerodynamic investigation was conducted to provide data for studies to determine the criteria for simulating rocket engine plume induced aerodynamic effects in the wind tunnel using a simulated gaseous plume. Model surface and base pressure data were obtained in the presence of both a simulated and a prototype gaseous plume for a matrix of plume properties to enable investigators to determine the parameters that correlate the simulated and prototype plume-induced data. The test program was conducted in the Marshall Space Flight Center's 14 x 14-inch trisonic wind tunnel using two models, the first being a strut mounted cone-ogive-cylinder model with a fineness ratio of 9. Model exterior pressures, model plenum chamber and nozzle performance data were obtained at Mach numbers of 0.9, 1.2, 1.46, and 3.48. The exhaust plume was generated by using air as the simulant gas, or Freon-14 (CF4) as the prototype gas, over a chamber pressure range from 0 to 2,000 psia and a total temperature range from 50 to 600 F.

Andrews, C. D.↗

Performance characteristics of rotating wickless heat pipes

A theoretical model was derived for laminar film condensation on the inside of a rotating, truncated cone which includes the effects of vapor shear and vapor pressure drop. Results are compared to those of previous investigations. Experimental data are presented for rotational speeds of 700, 1,400, 2,100, and 2,800 rpm using water, ethyl alcohol, and Freon 113 as working fluids. Agreement between theory and experiment is within + or - 20 percent.

Marto, P. J.↗

Flash evaporator systems test

A flash evaporator heat rejection system representative of that proposed for the space shuttle orbiter underwent extensive system testing at the NASA Johnson Space Center (JSC) to determine its operational suitability and to establish system performance/operational characteristics for use in the shuttle system. During the tests the evaporator system demonstrated its suitability to meet the shuttle requirements by: (1) efficient operation with 90 to 95% water evaporation efficiency, (2) control of outlet temperature to 40 + or - 2 F for partial heat load operation, (3) stability of control system for rapid changes in Freon inlet temperature, and (4) repeated dormant-to-active device operation without any startup procedures.

Dietz, J. B.↗

Effect of transient liquid flow on retention characteristics of screen acquisition systems

A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

Cady, E. C.↗

Evaluation of performance impairment by spacecraft contaminants

The environmental contaminants (isolated as off-gases in Skylab and Apollo missions) were evaluated. Specifically, six contaminants were evaluated for their effects on the behavior of juvenile baboons. The concentrations of contaminants were determined through preliminary range-finding studies with laboratory rats. The contaminants evaluated were acetone, methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), trichloroethylene (TCE), heptane and Freon 21. When the studies of the individual gases were completed, the baboons were also exposed to a mixture of MEK and TCE. The data obtained revealed alterations in the behavior of baboons exposed to relatively low levels of the contaminants. These findings were presented at the First International Symposium on Voluntary Inhalation of Industrial Solvents in Mexico City, June 21-24, 1976. A preprint of the proceedings is included.

Geller, I.↗

Sulfur poisoning of hydrocarbon oxidation by palladium

Using a differential bed recycle reactor the oxidation of ethane and diethyl ketone by a Pd catalyst was studied at the 0-30 ppm level in air. In both cases first order kinetics were observed. The ethane oxidation rate was characterized n the Arrhenius form by a pre-exponential of 1.0 x 10 to the 8th power cm/sec and an E sub a of 27 kcal/mole. The diethyl ketone oxidation rate was characterized by a pre-exponential of 5.7 x -1000 cm/sec and E sub a of 14 kcal/mole. Poisoning of ethan oxidation was also investigated by hydrogen sulfide and to a smaller extent by the refrigerants Freon 22 and Gentron 142-B. Poisoning by Gentron 142-B was much more severe than by hydrogen sulfide. Kinetic experiments indicated that only the pre-exponential was changing.

Baumgartner, A. J.↗

Corona-discharge air-purification system

Plasma reaction chamber removes trace contaminants from spacecraft, submarines, and other closed environments by oxidizing contaminants to produce carbon dioxide and water. Contaminants are alcohols, esters, hydrogen sulfide, and ammonia. Others are lubricant solvents such as Freons, aromatics, and Ketones. Contaminants are removed from chamber by scrubber.

Wydeven, T. J.↗

Measurements of blast waves from bursting frangible spheres pressurized with flash-evaporation vapor or liquid

Incident overpressure data from frangible spheres pressurized with a flash-evaporating fluid in liquid and vapor form were obtained in laboratory experiments. Glass spheres under higher than ambient internal pressure of Freon-12 were purposely burst to obtain time histories of overpressure. Nondimensional peak pressures, arrival and duration times, and impulses are presented, and whenever possible plotted and compared with compiled data for Pentolite high-explosive. The data are generally quite repeatable and show differences from blast data produced by condensed high-explosives.

Esparaza, E. D.↗