At least 181 records · Page 10

Failure Analysis Study and Long-Term Reliability of Optical Assemblies with End-Face Damage

In June 2005, the NESC received a multi-faceted request to determine the long term reliability of fiber optic termini on the ISS that exhibited flaws not manufactured to best workmanship practices. There was a lack of data related to fiber optic workmanship as it affects the long term reliability of optical fiber assemblies in a harsh environment. A fiber optic defect analysis was requested which would find and/or create various types of chips, spalls, scratches, etc., that were identified by the ISS personnel. Once the defects and causes were identified the next step would be to perform long term reliability testing of similar assemblies with similar defects. The goal of the defect analysis would be for the defects to be observed and documented for deterioration of fiber optic performance. Though this report mostly discusses what has been determined as evidence of poor manufacturing processes, it also concludes the majority of the damage could have been avoided with a rigorous process in place.

Kichak, Robert A.↗

International Space Station Solar Alpha Rotary Joint Failure Analysis: The Materials and Processes Perspective

This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the ISS configurations spanning ISS Stage 12A. The objective of this analysis is to validate and correlate analytical models used to verify the ISS critical interface dynamic loads and improve its fatigue life prediction. On-Orbit dynamic responses were measured during the ISS configurations throughout ISS Stage 12A by the two main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS) and the Structural Dynamic Measurement System (SDMS). These nominal on-orbit events include Russian vehicle docking and undockings. Also, the ISS photogrammetric system recorded the movements of the 2A and 4A solar arrays during a modified ISS maneuver. Modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shapes. Correlation and comparisons between the test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the ISS configurations under consideration.

Dasgupta, Rajib↗

The Development of Directional Decohesion Finite Elements for Multiscale Failure Analysis of Metallic Polycrystals

Atomistic simulations of intergranular fracture have indicated that grain-scale crack growth in polycrystalline metals can be direction dependent. At these material length scales, the atomic environment greatly influences the nature of intergranular crack propagation, through either brittle or ductile mechanisms, that are a function of adjacent grain orientation and direction of crack propagation. Methods have been developed to obtain cohesive zone models (CZM) directly from molecular dynamics simulations. These CZMs may be incorporated into decohesion finite element formulations to simulate fracture at larger length scales. A new directional decohesion element is presented that calculates the direction of Mode I opening and incorporates a material criterion for dislocation emission based on the local crystallographic environment to automatically select the CZM that best represents crack growth. The simulation of fracture in 2-D and 3-D aluminum polycrystals is used to illustrate the effect of parameterized CZMs and the effectiveness of directional decohesion finite elements.

Saether, Erik↗

Materials and Processes Engineering's Role in the Reconstruction and Failure Analysis of The Space Shuttle Columbia

Conclusions: The hot gases, having flooded the wing interior, quickly heated the upper and lower wing surfaces allowing the aluminum honeycomb facesheets and the wing tiles to debond. The thin-wall aluminum truss tubes would soon collapse and the aerodynamic and structural integrity of the left wing would be effectively destroyed. The forensic evidence is consistent with the observed External Tank foam impact 81 seconds into launch. This is the most probable cause of the damage to the Reinforced Carbon-Carbon. (RCC) leading edge.

Russell, Richard↗

Characterization of Deposits on Glass Substrate as a Tool in Failure Analysis: The Orbiter Vehicle Columbia Case Study

In connection with the accident investigation of the space shuttle Columbia, an analysis methodology utilizing well established microscopic and spectroscopic techniques was implemented for evaluating the environment to which the exterior fused silica glass was exposed. Through the implementation of optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and electron diffraction, details emerged regarding the manner in which a charred metallic deposited layer formed on top of the exposed glass. Due to nature of the substrate and the materials deposited, the methodology proved to allow for a more detailed analysis of the vehicle breakup. By contrast, similar analytical methodologies on metallic substrates have proven to be challenging due to strong potential for error resulting from substrate contamination. This information proved to be valuable to not only those involved in investigating the break up of Columbia, but also provides a potential guide for investigating future high altitude and high energy accidents.

Olivas, J. D.↗

Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line

During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures (Fig 6). Section wall reduction in the burst region. Plastic deformation and thinning of the out-of-specification tube wall likely happened during the initial proof testing years ago. Metallography of tubing away from rupture site confirmed tubing was seamless. Based on the tube microstructure, it is likely that the initial wall thickness was about 30 % thinner than the requirement of 0.049 inches. Fracture initiated on the ID and progressed to the OD (shear lip). The tube is made of the correct material of 5052-0 aluminum as verified using Optical Emission Spectroscopy (Table 2). The tubing hardness tested 77 HV100 (77 HRE). This hardness is slightly above the requirement for 70 HRE maximum for aluminum 5052-0 in AMS 2658C [3].

Martinez, J. E.↗

Failure Analysis of Main Flame Deflector Nelson Studs

NASA Structures engineers submitted two Nelson refractory studs from the main flame deflector at Launch Complex (LC) 39 A for analysis when they were observed to be missing a significant amount of material after launch. The damaged stud and an unused comparative stud were analyzed by macroscopic and microscopic examination along with metallographic evaluation of the microstructure. The stud lost material due to a combination of erosion and corrosion. Plain carbon steel readily forms an oxide layer in the coastal launch environment at Kennedy Space Center. The blast during a launch removes this brittle oxide layer, which then forms again post-launch, thereby further removing material. No indications of melting were observed.

Long, Victoria↗

Space Shuttle Columbia Aging Wiring Failure Analysis

A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

McDaniels, Steven J.↗

Physics of Failure Analysis of Xilinx Flip Chip CCGA Packages: Effects of Mission Environments on Properties of LP2 Underfill and ATI Lid Adhesive Materials

The Xilinx Virtex 4QV and 5QV (V4 and V5) are next-generation field-programmable gate arrays (FPGAs) for space applications. However, there have been concerns within the space community regarding the non-hermeticity of V4/V5 packages; polymeric materials such as the underfill and lid adhesive will be directly exposed to the space environment. In this study, reliability concerns associated with the non-hermeticity of V4/V5 packages were investigated by studying properties and behavior of the underfill and the lid adhesvie materials used in V4/V5 packages.

Suh, Jong-ook↗

Benchmarking Mixed Mode Failure in Progressive Damage and Failure Analysis Methods

The verification and validation of progressive-damage-analysis finite element methods are difficult but critical tasks to undertake during their development. Verification exercises assess whether a predictive analysis tool produces results that are consistent with the fundamental concepts and assumptions of the tool under evaluation. Ideally, closed-form analytical solutions can be derived for which method verification results can be compared. Problems selected for computational tool verification are often simple and isolate individual features of the tool. In the case of progressive damage finite element methods, verifications should be performed to evaluate the ability of the model to predict the initiation of damage and its growth through the finite element mesh under a variety of conditions. Mabson et al. proposed a test case of a unidirectional, fiber-reinforced plate with a center crack subjected to tensile loads to evaluate matrix crack propagation predictions. The problem was modeled using the Abaqus Hashin continuum damage mechanics (CDM) model for fiber-reinforced composites. Different combinations of matrix strengths and element sizes were used in the simulations, and the results were compared to a closed-form solution based on linear elastic fracture mechanics (LEFM). It was determined that the Abaqus CDM model could predict the LEFM solution of Mode I cracks only when the finite element mesh density met specific requirements based on the material properties. This paper presents closed-form LEFM solutions for a center notch mixed mode (CNMM) verification problem. Parametric finite element analyses were developed using progressive damage analysis methods of both the Discrete Damage Mechanics (DDM) and CDM classes. The progressive damage analysis methods applied in the analyses of the CNMM problem include CompDam and the Floating Node Method. Analyses were conducted with various mode mixities and element sizes to verify that the damage models were working as intended and to identify any limits of applicability.

Leone, Frank↗

Physics of failure analysis of Xilinx Flip Chip CCGA packages: effects of mission environments on properties of LP2 underfill and ATI lid adhesive materials

The Xilinx Virtex 4QV and 5QV (V4 and V5) are next-generation field-programmable gate arrays (FPGAs) for space applications. However, there have been concerns within the space community regarding the non-hermeticity of V4/V5 packages; polymeric materials such as the underfill and lid adhesive will be directly exposed to the space environment. In this study, reliability concerns associated with the non-hermeticity of V4/V5 packages were investigated by studying properties and behavior of the underfill and the lid adhesvie materials used in V4/V5 packages.

Suh, Jong-ook↗