Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast neutrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

24.1.3.1 - Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested in FY2021 to demonstrate a practical rapid verification system in FY2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Optimization of 133m Xe Production via Neutron Irradiation in a TRIGA Reactor

Here, the Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests worldwide. As part of treaty compliance, the concentration of radioactive nuclides in the atmosphere is monitored to detect nuclear weapons tests. Radioactive noble gas fission products, specifically radioxenon, can vent into the atmosphere after a nuclear weapons test, even if the test is well contained underground or underwater. Radioxenon thus serves as a signal for nuclear weapons tests. All atmospheric monitoring systems require samples of radioxenon isotopes for detector calibration, quality control, and certification. Here, we present a novel, improved method for creating samples of 133m Xe via neutron irradiation of 132 Xe in the Washington State University TRIGA reactor. 132 Xe neutron absorption results in either 133 Xe or 133m Xe—thermal neutron absorption results in 133m Xe 12% of the time, while fast neutron absorption (above ~1 MeV) results in 133m Xe ~50% of the time. To optimize the production of 133m Xe via neutron absorption in 132 Xe in the thermal TRIGA reactor, spectral tuning using an irradiation chamber is required to maximize the fraction of fast neutrons being absorbed and minimize the number of thermal neutrons interacting with the 132 Xe. We used MCNP to tally 132 Xe absorptions with the isotopic tally function, flux tallies and neutron attenuation to estimate the number of neutrons reaching the 132 Xe through the irradiation chamber, and the adjoint importance function to improve the source strength estimate. Additionally, we performed a heat transfer analysis for safety considerations. It was determined that the use of a 96% enriched 10 B boron carbide chamber, placed next to the fuel elements in reactor position D8, increases the 133m Xe/ 133 Xe activity ratio from a baseline value of 0.3 to 1.0, a 233% increase. Additionally, it was determined that the alpha heating produced in the boron does not become an unmanageable problem in the Washington State University reactor.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Measurement of proton quenching in a plastic scintillator detector

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks' constants are extracted from the data, and found to be $k_B = (8.70 \pm 0.93)\times 10^{-3}\ {\rm g/cm^2/MeV}$ and $k_C = (1.42 \pm 1.00) \times 10^{-5}\ {\rm (g/cm^2/MeV)^2}$. This result covers a unique energy range that is of direct relevance for fast neutron backgrounds in reactor inverse beta decay detectors. Furthermore, these measurements will improve the energy non-linearity modeling of plastic scintillator detectors. In particular, the updated energy response model will lead to an improvement of fast neutron modeling for detectors based on the CHANDLER reactor neutrino detector technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

Verification of Spent Fuel Inside Dry Storage Casks Using Neutron Mapping (2022 Midyear Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested to demonstrate a practical rapid verification system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping (FY2022 NA-241 Annual Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multidetector scanning array will be built and tested to demonstrate a practical rapid verification system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Critical response to M. Worrall et al. Published in Annals of Nuclear Energy 207 (2024) 110731

M. Worrall et al. recently published a manuscript titled “Fast neutron irradiation capability in existing thermal test reactors” (Worrall, 2024) that summarizes an irradiation vehicle design that would boost the fast neutron flux in the Advanced Test Reactor (ATR) for testing of nonfuel materials in a neutron flux energy spectrum that is more representative of fast reactors. Here, the authors compare their design with a separate vehicle design that they conceived of that would be implemented within the High Flux Isotope Reactor (HFIR). They analyzed both designs and drew conclusions on the most realistic near-term options for shielded nonfuel material irradiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental uncertainty quantification using templates of expected measurement uncertainties for fast neutron-induced total, capture, and scattering cross sections

Careful experimental uncertainty quantification (UQ) is key for developing trustworthy evaluated nuclear data. Templates to account for missing or under-reported experimental uncertainties were recently developed by the covariance committee of Cross Section Evaluation Working Group (CSEWG). In this work, we illustrate the practical application and limitations of these templates for selected neutron-induced reactions, including (n, tot), (n, γ), and (n, xn) in the fast energy range, to illustrate their use in data analyses for nuclear data evaluations. We show that while the templates provide consistent framework, proper implementation still requires detailed knowledge of experimental conditions and careful treatment of nonlinear effects in cross section derivation. Case studies highlight how template-assisted UQ improves consistency with previous evaluations such as ENDF/B and reveals open challenges in propagating uncertainties across different energy regimes. The main contribution of this paper is to connect formal template recommendations with their use in practical evaluation workflows, clarifying both their benefits and current limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dopant, coating, and grating effects in silica optical fibers under extreme neutron irradiation

Radiation effects on fiber Bragg gratings (FBGs) have been studied but data gaps related to the effects of displacement damage resulting from high fast neutron fluence remain. In this work, Type-I and Type-II FBGs inscribed in optical fibers with various core dopants (Ge and F) and fiber coatings (acrylate, polyimide) were monitored in situ during 75 days of neutron irradiation to a peak fast (>0.1 MeV) neutron fluence of 3 X 10 21 n fast /cm 2 . Further, the reflected intensity of the Type-I FBGs inscribed in a Ge-doped core fiber decreased by > 30 dB within 7 h of irradiation (10 19 n fast /cm 2 ), whereas Type-II FBGs inscribed in a pure silica core fiber eventually approached >40 dB attenuation after accumulating a fast neutron fluence on the order of 10 20 n fast /cm 2 . Type-II FBGs inscribed in F-doped core fiber improved stability: the attenuation approached an equilibrium value in the range of 10 to 20 dB.

47 OTHER INSTRUMENTATION↗

Effects of Neutron Irradiation on the Bond Strength of Steel Embedded in Concrete

The structural integrity of the concrete biological shield (CBS) in light water reactors (LWRs) exposed to long-term radiation raises the question of the effects of fast-neutron and gamma irradiation on the bond properties of embedded carbon-steel reinforcement in concrete, which is critical to the transfer of in-service and accidental loads. The design and execution of a first-of-a-kind irradiation experiment conducted in the LVR-15 test reactor (Czech Republic) are presented along with preliminary post-irradiation examination and testing results. Preliminary analysis shows that the fast neutron flux affects the radiation-induced volumetric of concrete aggregate, that the gamma irradiation induces shrinkage of the chemically bonded water in cementitious hydrates and that the bond strength of steel in concrete at the tested irradiation conditions decreases moderately.

Le Pape, Yann↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hauser-Feshbach Analysis of Fast Neutron-Induced Reactions on Chlorine

Neutron-induced reactions on 35Cl have recently been measured and analyzed in a Hauser-Feshbach framework at Los Alamos National Laboratory. Particular focus has been applied to the “fast” energy range above 100 keV, where these reactions become important for applications like CLYC (Cs 2 LiYCl 6 :Ce) detector characterization and the development of molten chloride fast reactors. However, challenges to applying a purely statistical analysis to this mass range have presented themselves in the form of cross section fluctuations and deviations due to low-mass structure. In this paper, these challenges and their current solutions will be highlighted, as well as preliminary extensions of the analysis to neighboring isotopes and future plans to extend the measurements down to thermal energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MITR & NBSR DDE Irradiations in BR2 – Fluence in LEU Cladding and Structural Materials

The BR2 nuclear reactor is a material testing reactor (MTR) located in Mol, Belgium, and operated by the Belgian Nuclear Research Centre (SCK CEN) since 1963. The reactor is highly versatile as the number and location of fuel elements and control rods can change significantly from cycle to cycle to accommodate different needs. Argonne National Laboratory (ANL or Argonne) Reactor Conversion (RC) team has collaborated with SCK CEN for over a decade on the conversion of domestic and international research reactors from highly enriched uranium (HEU, ≥20 wt.% of 235 U) to low enriched uranium (LEU, <20 wt.% of 235 U) fuel. The U.S. High-Performance Research Reactor (USHPRR) project within the M3 Reactor Conversion Program aims at converting five U.S. high performance research reactors (MITR, MURR, NBSR, HFIR, and ATR) and one critical facility (ATR-C) to LEU fuel. These USHPRRs still use and regularly refuel with HEU fuel. Each facility has a unique reactor design, operating conditions, and fuel element design to accomplish its mission. The goal of the USHPRR project is to convert the USHPRRs and the critical facility to LEU fuel while maintaining experimental performance and ensuring safe facility operation. The current technical report focuses on two reactors requiring very high-density LEU fuel: the Massachusetts Institute of Technology Reactor (MITR) and the National Bureau of Standards Reactor (NBSR). To support the conversion of these reactors, so-called design demonstration elements (DDE) are planned to be irradiated in the BR2 reactor under conditions similar to the targeted reactors and using a prototypic geometry. In support of this experiment, SCK CEN studied and modeled the DDE irradiations using MCNP6.2 to investigate the feasibility of irradiating the MITR DDE and NBSR DDE in BR2. Argonne reviewed and confirmed the conclusions of this study. Structural analysis is another step toward converting USHPRR to LEU fuel. The objective of the current report is to provide information useful to the structural analysis of the NBSR & MITR DDEs to support its irradiation in BR2. Specifically, the goal is to provide the fast neutron (E>0.1MeV) fluence in the cladding of the fuel plates in BR2 for the whole period of irradiation (8 cycles for MITR DDE and 10 cycles for NBSR DDE). Additionally, fast neutron fluences in the side plates and in the NBSR DDE’s outside plates were calculated and reported. Neutronic calculations were performed using MCNP6.2 on the RTRHPC cluster.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗