Search NASA⌕ Search

SEARCH · Search NASA

Results for “Feasibility Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Feasibility Study of a Passive, Standoff Detector of High Density Masses with a Gravity Gradiometer Based on Atom Interferometry

For the emergency response (ER) and treaty verification communities, methods to determine and/or verify the masses present in containers are highly desirable. Additionally, the ability to perform these measurements passively and rapidly is also important in the ER community. The ability to quantify relevant masses and aspects of their spatial distribution is essential for setting lower bounds in relevant ER calculations and for monitoring treaty compliance. The purpose of this feasibility study was to demonstrate a completely passive, rapid method to determine the mass of high-density material present in a closed box, without the need to move, radiograph, or otherwise manipulate the box. Our method applies an existing, DARPA-AOSense, Inc. developed gravity gradiometer based on atomic fountain interferometer technology originally invented by Steven Chu and his team at Stanford, to perform differential gravity measurements, taken from positions around the container with the heavy mass sources inside. In this feasibility study, done with the AOSense gradiometer, we (equivalently) carried out the measurements by moving the mass source, in the required arrangements and orientations, parallel to the atomic fountain axis. We also built and applied computational models of the atomic fountain responses to our high-density mass sources and the background container to enable the blind determination of the overall masses and configurations of material present in the container in our experiments.

42 ENGINEERING↗

Feasibility study of robotic neural controllers

The results are given of a feasibility study performed to establish if an artificial neural controller could be used to achieve joint space trajectory tracking of a two-link robot manipulator. The study is based on the results obtained by Hecht-Nielsen, who claims that a functional map can be implemented to a desired degree of accuracy with a three layer feedforward artificial neural network. Central to this study is the assumption that the robot model as well as its parameters values are known.

Magana, Mario E.↗

Feasibility Study of Optically Transparent Microstrip Patch Antenna

The paper presents a feasibility study on optically transparent patch antennas with microstrip line and probe feeds. The two antennas operate at 2.3 GHz and 19.5 GHz respectively. They are constructed from a thin sheet of clear polyester with an AgHT-8 optically transparent conductive coating. The experimental results show good radiation patterns and input impedance match. The antennas have potential applications in mobile wireless communications.

Simons, Rainee N.↗

Feasibility Study of Optically Transparent Microstrip Patch Antenna

The paper presents a feasibility study on optically transparent patch antennas with microstrip line and probe feeds. The two antennas operate at 2.3 GHz and 19.5 GHz respectively. They are constructed from a thin sheet of clear polyester with an AgHT-8 optically transparent conductive coating. The experimental results show good radiation patterns and input impedance match. The antennas have potential applications in mobile wireless communications.

Simons, Rainee N.↗

NASA CPAS Drogue Textile Riser Feasibility Study

Steel cable was chosen for the lower end of the drogue and main parachute risers on NASA's Orion Multi Purpose Crew Vehicle Parachute Assembly System (CPAS) to protect the risers from extreme temperatures and abrasion should they contact the crew module during deployment, as was done for Apollo. Due to the weight and deployment complexity inherent in steel, there was significant interest in the possibility of substituting textile for steel for the drogue and main parachute risers. However, textile risers could be damaged when subjected to high temperature and abrasion. Investigations were consequently performed by a subset of the authors to determine whether sacrificial, non-load-bearing textile riser covers could be developed to mitigate the thermal and abrasion concerns. Multiple material combinations were tested, resulting in a cover design capable of protecting the riser against severe riser/crew module contact interactions. A feasibility study was then conducted to evaluate the performance of the textile drogue riser cover in relevant abrasive environments. This paper describes the testing performed and documents the results of this feasibility study.

Hennings, Elsa J.↗

Sci—Thur AM: YIS - 04: Gold Nanoparticle Enhanced Arc Radiotherapy: A Monte Carlo Feasibility Study

Introduction: The use of gold nanoparticles (GNPs) in radiotherapy has shown promise for therapeutic enhancement. In this study, we explore the feasibility of enhancing radiotherapy with GNPs in an arc-therapy context. We use Monte Carlo simulations to quantify the macroscopic dose-enhancement ratio (DER) and tumour to normal tissue ratio (TNTR) as functions of photon energy over various tumour and body geometries. Methods: GNP-enhanced arc radiotherapy (GEART) was simulated using the PENELOPE Monte Carlo code and penEasy main program. We simulated 360° arc-therapy with monoenergetic photon energies 50 – 1000 keV and several clinical spectra used to treat a spherical tumour containing uniformly distributed GNPs in a cylindrical tissue phantom. Various geometries were used to simulate different tumour sizes and depths. Voxel dose was used to calculate DERs and TNTRs. Inhomogeneity effects were examined through skull dose in brain tumour treatment simulations. Results: Below 100 keV, DERs greater than 2.0 were observed. Compared to 6 MV, tumour dose at low energies was more conformai, with lower normal tissue dose and higher TNTRs. Both the DER and TNTR increased with increasing cylinder radius and decreasing tumour radius. The inclusion of bone showed excellent tumour conformality at low energies, though with an increase in skull dose (40% of tumour dose with 100 keV compared to 25% with 6 MV). Conclusions: Even in the presence of inhomogeneities, our results show promise for the treatment of deep-seated tumours with low-energy GEART, with greater tumour dose conformality and lower normal tissue dose than 6 MV.

60 APPLIED LIFE SCIENCES↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

Pascua Yaqui Tribe Renewable Energy Development and Deployment Solar Feasibility Study

In 2012, PYT was awarded a grant from the Department of Energy Tribal Energy Program to conduct a Renewable Energy Development and Deployment Feasibility Study that would define the technical and economic viability of renewable energy on tribal lands. Red Mountain Energy Partners (RMEP) was hired by PYT to complete the study. Through this study, Red Mountain concluded that there are viable opportunities for solar at Tortuga Ranch, the Casino del Sol and a third site near the Justice Center on Camino de Oeste.

14 SOLAR ENERGY↗

Investigation of surface tension driven convection as a feasibility study for a micro-gravity experiment

The work performed for the feasibility study of a microgravity surface tension driven convection experiment was reviewed. An experimental investigation of the onset of convection in shallow fluid layers heated uniformly from below and cooled from above by an air layer was made. Results are discussed in relation to the formation of Benard cells. The onset of Rayleigh-Benard convection in thin fluid layers heated uniformly from below were studied experimentally. It was found that in thin fluid layers the onset of Rayleigh-Benard convection is preceded by subcritical convective motions. Secondly, it was found that the onset of Rayleigh-Benard convection in non-Boussinesq fluid layers takes place in the form of hexagonal cells at Rayleigh numbers larger than the critical Rayleigh number R sub C = 1708 which determines the onset of convection in Boussinesq fluid layers.

Koschmieder, E. L.↗

Radiochemotherapy With Cetuximab, Cisplatin, and Amifostine for Locally Advanced Head and Neck Cancer: A Feasibility Study

Purpose: Radiotherapy (RT) combined with cisplatin or cetuximab is the standard of care for patients with locally advanced head/neck cancer (LA-HNC). The feasibility of radiochemotherapy with cisplatin and cetuximab, supported with amifostine, was herein investigated. Methods and Materials: Forty-three patients with LA-HNC were recruited. Conformal hypofractionated/accelerated RT with amifostine cytoprotection (2.7 Gy/fraction, 21 fractions in 4 weeks) was combined with cisplatin (30 mg/m{sup 2}/week) and cetuximab (standard weekly regimen) therapy. The dose of amifostine was individualized according to tolerance. Results: A high daily amifostine dose (750-1,000 mg) was tolerated by 41.8% of patients, and a standard dose (500 mg) was tolerated by 34.9% of patients. A high amifostine dose was linked to reduced RT delays (p = 0.0003). Grade 3 to 4 (3-4) mucositis occurred in 7/43 (16.2%) patients, and fungal infections occurred in 18/43 (41.8%) patients. Radiation dermatitis was not aggravated. Interruption of cetuximab due to acneiform rash was necessary in 23.3% of patients, while amifostine-related fever and rash were not observed. Severe late radiation sequelae consisted of laryngeal edema (9% laryngeal cases) and cervical strictures (33% of hypopharyngeal cases). Good salivary function was preserved in 6/11 (54.5%) nasopharyngeal cancer patients. The complete response rate was 68.5%, reaching 77.2% in patients with minor radiotherapy delays. The 24-month local control and survival rates were 72.3% and 91%, respectively (median follow-up was 13 months.). Conclusions: In this feasibility study, weekly administration of cisplatin and cetuximab was safely combined with accelerated RT, supported with amifostine, at the cost of a high incidence of acneiform rash but a reduced incidence of amifostine-related fever/rash. A high daily dose of amifostine allows completion of therapy with minor delays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm{sup 3}) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

60 APPLIED LIFE SCIENCES↗