Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Unexpected Control Structure Interaction on International Space Station

On June 23, 2011, the International Space Station (ISS) was performing a routine 180 degree yaw maneuver in support of a Russian vehicle docking when the on board Russian Segment (RS) software unexpectedly declared two attitude thrusters failed and switched thruster configurations in response to unanticipated ISS dynamic motion. Flight data analysis after the maneuver indicated that higher than predicted structural loads had been induced at various locations on the United States (U.S.) segment of the ISS. Further analysis revealed that the attitude control system was firing thrusters in response to both structural flex and rigid body rates, which resonated the structure and caused high loads and fatigue cycles. It was later determined that the thruster themselves were healthy. The RS software logic, which was intended to react to thruster failures, had instead been heavily influenced by interaction between the control system and structural flex. This paper will discuss the technical aspects of the control structure interaction problem that led to the RS control system firing thrusters in response to structural flex, the factors that led to insufficient preflight analysis of the thruster firings, and the ramifications the event had on the ISS. An immediate consequence included limiting which thrusters could be used for attitude control. This complicated the planning of on-orbit thruster events and necessitated the use of suboptimal thruster configurations that increased propellant usage and caused thruster lifetime usage concerns. In addition to the technical aspects of the problem, the team dynamics and communication shortcomings that led to such an event happening in an environment where extensive analysis is performed in support of human space flight will also be examined. Finally, the technical solution will be presented, which required a multidisciplinary effort between the U.S. and Russian control system engineers and loads and dynamics structural engineers to develop and implement an extensive modification in the RS software logic for ISS attitude control thruster firings.

Gomez, Susan F.↗

RECOVER: An Automated Cloud-Based Decision Support System for Post-fire Rehabilitation Planning

RECOVER is a site-specific decision support system that automatically brings together in a single analysis environment the information necessary for post-fire rehabilitation decision-making. After a major wildfire, law requires that the federal land management agencies certify a comprehensive plan for public safety, burned area stabilization, resource protection, and site recovery. These burned area emergency response (BAER) plans are a crucial part of our national response to wildfire disasters and depend heavily on data acquired from a variety of sources. Final plans are due within 21 days of control of a major wildfire and become the guiding document for managing the activities and budgets for all subsequent remediation efforts. There are few instances in the federal government where plans of such wide-ranging scope and importance are assembled on such short notice and translated into action more quickly. RECOVER has been designed in close collaboration with our agency partners and directly addresses their high-priority decision-making requirements. In response to a fire detection event, RECOVER uses the rapid resource allocation capabilities of cloud computing to automatically collect Earth observational data, derived decision products, and historic biophysical data so that when the fire is contained, BAER teams will have a complete and ready-to-use RECOVER dataset and GIS analysis environment customized for the target wildfire. Initial studies suggest that RECOVER can transform this information-intensive process by reducing from days to a matter of minutes the time required to assemble and deliver crucial wildfire-related data.

cloud computing↗

Risk-Informed Systems Analysis (RISA) Dynamic Fire PRA Roadmap

Modeling and implementing fire safety for nuclear power plants is a costly activity. Because of the complexity of fire phenomenon and multiple operational procedures, it is difficult to computationally provide assurance that the mitigation methods are adequate for critical areas using current analysis methods. An economical method to provide more accurate modeling and optimize mitigation methods is needed to improve nuclear power viability. This report describes the initial investigation into modeling and simulation tools for application of fire as part of the Risk-Informed Systems Analysis (RISA), formerly Risk-Informed Safety Margin Characterization (RISMC). The report provides a framework of how 3D modeling and simulation techniques could be combined with a dynamic Probabilistic Risk Analysis (PRA) to reduce compounding conservatism present in current Fire PRA methods. Electrical Power Research Institute has analyzed current Fire PRA practices and identified the most significant contributors to risk and areas for improving analysis. This framework describes how to apply dynamic PRA and simulation methods for key contributors/scenarios, credit missing factors of manual fire suppression, and applying conditional probabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of Oxy Boiler Design Guidelines and Design Considerations (Topical Report- Recovery Act: Oxy-Combustion Technology Development for Industrial-Scale Boiler Applications)

This Topical Report outlines guidelines and key considerations for design and operation of pulverized coal-fired boilers for oxy-combustion. The scope addressed includes only the boiler island, not the entire oxy-fired CO 2 capture plant. These guidelines are primarily developed for tangential-fired boilers and focus on designs capable of dual air and oxy-fired operation. The guidelines and considerations discussed are applicable to both new units and existing boiler retrofits. These guidelines are largely based on the findings from the extensive 15 MW th pilot testing and design efforts conducted under this project. A summary level description is provided for each major aspect of boiler design impacted by oxy-combustion, and key considerations are discussed for broader application to different utility and industrial designs. Guidelines address the boiler system arrangement, firing system, boiler thermal design, ducting, materials, control system, and other key systems.

42 ENGINEERING↗

Evaluation of Gas, Oil and Wood Pellet Fueled Residential Heating System Emissions Characteristics

This study has measured the emissions from a wide range of heating equipment burning different fuels including several liquid fuel options, utility supplied natural gas and wood pellet resources. The major effort was placed on generating a database for the mass emission rate of fine particulates (PM 2.5) for the various fuel types studied. The fine particulates or PM 2.5 (less than 2.5 microns in size) were measured using a dilution tunnel technique following the method described in US EPA CTM-039. The PM 2.5 emission results are expressed in several units for the benefit of scientists, engineers and administrators. The measurements of gaseous emissions of O{sub 2}, CO{sub 2}, CO, NO{sub x} and SO{sub 2} were made using a combustion analyzer based on electrochemical cells These measurements are presented for each of the residential heating systems tested. This analyzer also provides a steady state efficiency based on stack gas and temperature measurements and these values are included in the report. The gaseous results are within the ranges expected from prior emission studies with the enhancement of expanding these measurements to fuels not available to earlier researchers. Based on measured excess air levels and ultimate analysis of the fuel's chemical composition the gaseous emission results are as expected and fall within the range provided for emission factors contained in the US-EPA AP 42, Emission Factors Volume I, Fifth Edition. Since there were no unexpected findings in these gaseous measurements, the bulk of the report is centered on the emissions of fine particulates, or PM 2.5. The fine particulate (PM 2.5) results for the liquid fuel fired heating systems indicate a very strong linear relationship between the fine particulate emissions and the sulfur content of the liquid fuels being studied. This is illustrated by the plot contained in the first figure on the next page which clearly illustrates the linear relationship between the measured mass of fine particulate per unit of energy, expressed as milligrams per Mega-Joule (mg/MJ) versus the different sulfur contents of four different heating fuels. These were tested in a conventional cast iron boiler equipped with a flame retention head burner. The fuels included a typical ASTM No. 2 fuel oil with sulfur below 0.5 percent (1520 average ppm S), an ASTM No. 2 fuel oil with very high sulfur content (5780 ppm S), low sulfur heating oil (322 ppm S) and an ultra low sulfur diesel fuel (11 ppm S). Three additional oil-fired heating system types were also tested with normal heating fuel, low sulfur and ultralow sulfur fuel. They included an oil-fired warm air furnace of conventional design, a high efficiency condensing warm air furnace, a condensing hydronic boiler and the conventional hydronic boiler as discussed above. The linearity in the results was observed with all of the different oil-fired equipment types (as shown in the second figure on the next page). A linear regression of the data resulted in an Rsquared value of 0.99 indicating that a very good linear relationship exits. This means that as sulfur decreases the PM 2.5 emissions are reduced in a linear manner within the sulfur content range tested. At the ultra low sulfur level (15 ppm S) the amount of PM 2.5 had been reduced dramatically to an average of 0.043 mg/MJ. Three different gas-fired heating systems were tested. These included a conventional in-shot induced draft warm air furnace, an atmospheric fired hydronic boiler and a high efficiency hydronic boiler. The particulate (PM 2.5) measured ranged from 0.011 to 0.036 mg/MJ. depending on the raw material source used in their manufacture. All three stoves tested were fueled with premium (low ash) wood pellets obtained in a single batch to provide for uniformity in the test fuel. Unlike the oil and gas fired systems, the wood pellet stoves had measurable amounts of particulates sized above the 2.5-micron size that defines fine particulates (less than 2.5 microns). The fine particulate emissions rates ranged from 22 to 30 mg/ MJ with an average value of 25 mg/MJ for the three stoves tested.

02 PETROLEUM↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emergency escape system protects personnel from explosion and fire

Elevator-type emergency escape system evacuates personnel from tall structures, especially when the possibility of explosion or fire exists. The system consists of a spike shaped rescue cabin which descends along a vertical guide cable, penetrates the dome shaped roof of an underground blast shelter and stops in a deceleration bed of granular material.

Offik, W. G.↗

Life cycle assessment of biochar produced from forest residues using portable systems

Forest fires are getting extreme and more frequent because of increased fuel loads in the forest and extended dry conditions. Fuel treatment (i.e., thinning) methods to mitigate forest fires will generate large volumes of forest residues together with available logging residues that can be used to produce biochar. It has been proposed that portable biochar systems are economical means to utilize forest residues as an alternative to slash burning. In this study, the environmental impacts of biochar produced from forest residues using three portable systems [1. Biochar Solutions Incorporated (BSI), 2. Oregon Kiln, and 3. Air-curtain Burner] were evaluated using a cradle-to-gate life-cycle assessment approach. Environmental impacts were analyzed considering the various quality of feedstock, biomass collection methods, different production sites, and various sources of power used in the production of biochar. The results illustrate that the global warming potential (GWP) of biochar production from forest residues through BSI, Oregon Kiln, and Air-Curtain Burner were 0.25–0.31, 0.11, and 0.16 tonne CO 2 eq./tonne of fixed carbon in biochar respectively. Compared to pile burn, biochar production from forest residues with a portable system at the landing, reduced global warming potential (GWP) by 1.92–2.83, 2.7, and 1.9 tonnes CO 2 eq./tonne of biochar through BSI, Oregon Kiln, and Air-Curtain Burner respectively. The Air-Curtain Burner and Oregon Kiln have minimal feedstock preparation, thus have lower environmental impacts than the BSI system. The BSI system requires feedstock preparation and power to operate the system. The use of the biomass-gasifier generator improved the environmental performance substantially (16–280%) compared with a diesel generator in biochar production. Overall, the net GWP in biochar produced (0.10–1.63 tonne CO 2 eq./tonne of residues) from forest residues can reduce environmental impacts (2–40 times lower net CO 2 eq. emissions) compared to slash burning.

54 ENVIRONMENTAL SCIENCES↗

Skylab Medical Experiments Altitude Test /SMEAT/ facility design and operation.

This paper presents the design approaches and test facility operation methods used to successfully accomplish a 56-day test for Skylab to permit evaluation of selected Skylab medical experiments in a ground test simulation of the Skylab environment with an astronaut crew. The systems designed for this test include the two-gas environmental control system, the fire suppression and detection system, equipment transfer lock, ground support equipment, safety systems, potable water system, waste management system, lighting and power system, television monitoring, communications and recreation systems, and food freezer.

Hinners, A. H., Jr.↗

Reduction of fire hazards on large mining equipment

Although standards and regulations are in place to prevent large mining equipment fires, recent analyses of mine accident data show that mining equipment fires still occur with alarming frequency and grave consequences, particularly at all surface mines and in underground metal/nonmetal mines. Recently technological advances in fire protection, combined with the statistical data on equipment fires, led NIOSH to reinvestigate this and to improve operator safety. NIOSH demonstrated that newly developed technologies, such as dual cab fire inerting systems and engine compartment fire barriers, can greatly enhance operator safety and lessen the damage of property during large mobile equipment fires. 10 refs., 5 figs.

01 COAL, LIGNITE, AND PEAT↗

Use of Systems Engineering in Repurposing Coal-Fired Power Plants with Malta Pumped Thermal Energy Storage System

he electric sector across North America is facing a transition. Both economics and policy decisions have pointed towards a broad retirement of fossil assets across markets. Owners are facing the problem of how to evolve the base of the electric sector from fossil asset to greener alternative. Coal-fired power plants built the modern electricity grid. Their rotating machinery are the beating heart of the grid, providing essential resiliency and reliability services. Power plant retirements are disruptive to plant workforces and cause outsized impacts on surrounding communities. The transition from thermal power plants that use rotating machinery to generate electricity (e.g., coal- and gas-fired plants) to variable, inverter-based generation (e.g., solar and wind) is affecting the reliability of the electric grid. Grid operators and national regulators have issued warnings about known and anticipated risk. In 2021, Malta Inc. was awarded a Department of Energy (DOE) grant to study how to integrate a Malta 100MW Pumped Heat Energy Storage (PHES) system with a retiring coal-fired power plant to meet emissions requirements, retain plant workforces, preserve communities, and maintain grid reliability. This presentation provides a summary of this study, focusing on how systems engineering approach was used to arrive at a proposed design concept that met multiple objectives and requirements. There will be three main parts for this presentation. The first part of the presentation will focus on how different systems engineering was applied for this work. In particular, the following areas: stakeholder engagement, site selection process, developing requirements and use cases for the integrated system, defining the system and its boundary, coming up with different system architecture/option, performing a techno-economic analysis to compare the different options and down selection of the preferred option, will be discusses. For these areas, discussion on the decisions on how much breadth and depth to go into each area will be provided. These discussions provide good insights into how to apply systems engineering. The second part of the presentation will provide a deeper dive into the two recommended integration options that repurpose coal-fired power plants with Malta PHES system. The comparison of the two options and general guidance of how to choose an option will be provided. This is particularly useful for utilities who are facing coal-plant retirements. The two options will be compared based on its performance (such as power output, efficiency), complexity, and cost. The social impact on local communities of the two options will also be discussed. The final part of the presentation will discuss the impact that this work has had, including Malta Inc. being invited to the White House to discuss progress and outcomes of this work with the Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization. In summary, this presentation aims to provide a showcase of how sy

25 ENERGY STORAGE↗

FY24 – FY25 Efforts to Revive the ANS-54.8 Liquid Metal Fire Protection in LMR Plants Standard

The current multi-year effort seeks to utilize national laboratory support from Argonne to expedite revival of the ANS-54.8 standard titled “Liquid Metal Fire Protection in LMR Plants.” To achieve that objective, the following tasks were identified: Task 1 involves working directly with ANS to revive the ANS-54.8 Working Group. This was to be accomplished by completing necessary paperwork, submitting that paperwork to ANS for approval, enlisting potential working group members from industry, the NRC, national laboratories, and universities, and organizing and leading Working Group activities. The overall purpose of the Working Group is to develop an updated draft of ANS-54.8 for review and approval by ANS consensus committees, the ANS Standards Board, and certification from ANSI. Task 2 focuses on leveraging historical information and expertise at Argonne related to sodium fire protection systems and strategies. For more than a decade, Argonne has worked on both international and domestic projects related to sodium fire protection system development and evaluation. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group on important considerations that may be addressed in an updated draft of ANS-54.8. Task 3 focuses on leveraging Argonne experience in the development of and use of analysis methods and tools for the simulation of sodium fire scenarios and evaluation of the effectiveness of sodium fire protection systems and strategies. For more than a decade, Argonne has recovered, modified, and utilized several historical sodium fire analysis software tools. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group of best practices for sodium fire progression analysis that may be addressed in an updated draft of ANS-54.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

Ultraviolet fire detector

System is capable of detecting ultraviolet light emitted by match size flame at distance of 10 ft. System is not affected by high energy or particulate radiation and is therefore particularly suited for applications around nuclear plants and X-ray equipment.

Turnage, J. E.↗

Space Shuttle Orbiter crash and rescue information - Basic characteristics of the Space Shuttle system

Major fire and rescue activity procedures developed for the Space Shuttle Orbiter are reproduced, together with diagrams of the Orbiter's ejection seat and of emergency egress-ingress hatches and blowout panels. Duties assigned to the Manager of the Fire, Crash and Rescue division of the Space Shuttle Program are discussed, including training of both ground and flight personnel in accordance with the Orbiter Crash Rescue Information manual. The special problem of providing a means of egress and rescue for the flight and ground crews of the Orbiter while it is in the piggyback configuration on top the Boeing 747 carrier was solved by use of a modified 85-foot articulated boom.

Gray, N. C.↗

Forecasting Global Fire Emissions on Subseasonal to Seasonal (S2S) Time Scales

Fire emissions of gases and aerosols alter atmospheric composition and have substantial impacts on climate, ecosystem function, and human health. Warming climate and human expansion in fire‐prone landscapes exacerbate fire impacts and call for more effective management tools. Here we developed a global fire forecasting system that predicts monthly emissions using past fire data and climate variables for lead times of 1 to 6 months. Using monthly fire emissions from the Global Fire Emissions Database (GFED) as the prediction target, we fit a statistical time series model, the Autoregressive Integrated Moving Average model with eXogenous variables (ARIMAX), in over 1,300 different fire regions. Optimized parameters were then used to forecast future emissions. The forecast system took into account information about region‐specific seasonality, long‐term trends, recent fire observations, and climate drivers representing both large‐scale climate variability and local fire weather. We cross‐validated the forecast skill of the system with different combinations of predictors and forecast lead times. The reference model, which combined endogenous and exogenous predictors with a 1 month forecast lead time, explained 52% of the variability in the global fire emissions anomaly, considerably exceeding the performance of a reference model that assumed persistent emissions during the forecast period. The system also successfully resolved detailed spatial patterns of fire emissions anomalies in regions with significant fire activity. This study bridges the gap between the efforts of near‐real‐time fire forecasts and seasonal fire outlooks and represents a step toward establishing an operational global fire, smoke, and carbon cycle forecasting system.

vapor pressure↗

Quantifying the role of fire in the Earth system - Part 2: Impact on the net carbon balance of global terrestrial ecosystems for the 20th century

Fire is the primary terrestrial ecosystem disturbance agent on a global scale. It affects carbon balance of global terrestrial ecosystems by emitting carbon to atmosphere directly and immediately from biomass burning (i.e., fire direct effect), and by changing net ecosystem productivity and land-use carbon loss in post-fire regions due to biomass burning and fire-induced vegetation mortality (i.e., fire indirect effect). Here, we provide the first quantitative assessment about the impact of fire on the net carbon balance of global terrestrial ecosystems for the 20th century, and investigate the roles of fire direct and indirect effects. This study is done by quantifying the difference between the 20th century fire-on and fire-off simulations with NCAR community land model CLM4.5 as the model platform. Results show that fire decreases net carbon gain of the global terrestrial ecosystems by 1.0 Pg C yr-1 average across the 20th century, as a results of fire direct effect (1.9 Pg C yr-1) partly offset by indirect effect (-0.9 Pg C yr-1). Fire generally decreases the average carbon gains of terrestrial ecosystems in post-fire regions, which are significant over tropical savannas and part of forests in North America and the east of Asia. The general decrease of carbon gains in post-fire regions is because fire direct and indirect effects have similar spatial patterns and the former (to decrease carbon gain) is generally stronger. Moreover, the effect of fire on net carbon balance significantly declines prior to ~1970 with trend of 8 Tg C yr-1 due to increasing fire indirect effect and increases afterward with trend of 18 Tg C yr-1 due to increasing fire direct effect.

carbon cycle↗

The NASA/Baltimore Applications Project (BAP). Computer aided dispatch and communications system for the Baltimore Fire Department: A case study of urban technology application

An engineer and a computer expert from Goddard Space Flight Center were assigned to provide technical assistance in the design and installation of a computer assisted system for dispatching and communicating with fire department personnel and equipment in Baltimore City. Primary contributions were in decision making and management processes. The project is analyzed from four perspectives: (1) fire service; (2) technology transfer; (3) public administration; and (5) innovation. The city benefitted substantially from the approach and competence of the NASA personnel. Given the proper conditions, there are distinct advantages in having a nearby Federal laboratory provide assistance to a city on a continuing basis, as is done in the Baltimore Applications Project.

Levine, A. L.↗