Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

CID-720 aircraft Langley Research Center preflight hardware tests: Development, flight acceptance and qualification

The testing conducted on LaRC-developed hardware for the controlled impact demonstration transport aircraft is discussed. To properly develop flight qualified crash systems, two environments were considered: the aircraft flight environment with the focus on vibration and temperature effects, and the crash environment with the long pulse shock effects. Also with the large quantity of fuel in the wing tanks the possibility of fire was considered to be a threat to data retrieval and thus fire tests were included in the development test process. The aircraft test successfully demonstrated the performance of the LaRC developed heat shields. Good telemetered data (S-band) was received during the impact and slide-out phase, and even after the aircraft came to rest. The two onboard DAS tape recorders were protected from the intense fire and high quality tape data was recovered. The complete photographic system performed as planned throughout the 40.0 sec of film supply. The four photo power distribution pallets remained in good condition and all ten onboard 16 mm high speed (400 frames/sec) cameras produced good film data.

Pride, J. D.↗

Fires in P-3 Aircraft Oxygen Systems

Fires in three P3 aircraft oxygen systems have occurred: one in the Royal Australian Air Force (RAAF) in 1984 and two in the U.S. Navy in 1998 and 2003. All three fires started in the aluminum manifold and check valve (MCV) assembly and produced similar damages to the aircraft in which they occurred. This paper discusses a failure analysis conducted by the NASA Johnson Space Center White Sands Test Facility (WSTF) Oxygen Hazards and Testing Team on the 2003 U.S. Navy VP62 fire. It was surmised that the fire started due to heat generated by an oxygen leak past a silicone check valve seal or possibly because of particle impact near the seat of one of the MCV assembly check valves. An additional analysis of fires in several check valve poppet seals from other aircraft is discussed. These burned poppet seals came from P3 oxygen systems that had been serviced at the Naval Air Station (NAS) in Jacksonville following standard fill procedures. It was concluded that these seal fires occurred due to the heat from compression heating, particle impact, or the heat generated by an oxygen leak past the silicone check valve seal. The fact that catastrophic fires did not occur in the case of each check valve seal fire was attributed to the protective nature of the aluminum oxide layer on the check valve poppets. To prevent future fires of this nature, the U.S. and Canadian fleets of P3 aircraft have been retrofitted with MCV assemblies with an upgraded design and more burn-resistant materials.

Stoltzfus, Joel↗

Lessons Learned Entry: Hypergolic Propellant Related Spills and Fires

The attached report is a compilation of all credible, unintentional hypergolic fluid related spills, fires, and explosions from the Apollo Program, the Space Shuttle Program, Titan Program, and a few other programs. Spill sites include the following government facilities: KSC, JSC, WSTF, VAFB, CCAFS, EAFB, Little Rock AFB, and McConnell AFB. The root causes and consequences of the incidents contained in this document vary drastically; however, certain "themes" can be deduced and utilized for future hypergolic propellant handling. Some of those common "themes" are summarized below: (1) Improper configuration control and complacency can lead to being falsely comfortable with a system (2) Communication breakdown can escalate an incident to a level where injuries occur and/or hardware is damaged (3) Improper propulsion system and ground support system designs can destine a system for failure (4) Improper training of technicians, engineers, and safety personnel can put lives in danger (5) Improper PPE, spill protection, and staging of fire extinguishing equipment can result in unnecessary injuries or hardware damage if an incident occurs (6) Improper procedural oversight, development, and adherence to the procedure can be detrimental and quickly lead to an undesirable incident (7) Improper local cleanliness or compatibility can result in fires or explosions The items listed above are only a short list of the issues that should be recognized prior to handling of hypergolic fluids or processing of vehicles containing hypergolic propellants. The summary of incidents in this report is intended to cover many more issues than those listed above that have been found during nearly the entire spectrum. of hypergolic propellant and/or vehicle processing.

Nufer, Brian↗

A Summary of NASA and USAF Hypergolic Propellant Related Spills and Fires

Several unintentional hypergolic fluid related spills, fires, and explosions from the Apollo Program, the Space Shuttle Program, the Titan Program, and a few others have occurred over the past several decades. Spill sites include the following government facilities: Kennedy Space Center (KSC), Johnson Space Center (JSC), White Sands Test Facility (WSTF), Vandenberg Air Force Base (VAFB), Cape Canaveral Air Force Station (CCAFS), Edwards Air Force Base (EAFB), Little Rock AFB, and McConnell AFB. Until now, the only method of capturing the lessons learned from these incidents has been "word of mouth" or by studying each individual incident report. The root causes and consequences of the incidents vary drastically; however, certain "themes" can be deduced and utilized for future hypergolic propellant handling. Some of those common "themes" are summarized below: (1) Improper configuration control and internal or external human performance shaping factors can lead to being falsely comfortable with a system (2) Communication breakdown can escalate an incident to a level where injuries occur and/or hardware is damaged (3) Improper propulsion system and ground support system designs can destine a system for failure (4) Improper training of technicians, engineers, and safety personnel can put lives in danger (5) Improper PPE, spill protection, and staging of fire extinguishing equipment can result in unnecessary injuries or hardware damage if an incident occurs (6) Improper procedural oversight, development, and adherence to the procedure can be detrimental and quickly lead to an undesirable incident (7) Improper materials cleanliness or compatibility and chemical reactivity can result in fires or explosions (8) Improper established "back-out" and/or emergency safing procedures can escalate an event The items listed above are only a short list of the issues that should be recognized prior to handling hypergolic fluids or processing vehicles containing hypergolic propellants. The summary of incidents in this report is intended to cover many more issues than those listed above.

Nufer, Brian M.↗

The time since land-use transition drives changes in fire activity in the Amazon-Cerrado region

Abstract Deforestation and climate change are expected to alter fire regimes along the Cerrado-Amazon transition, one of the world’s most active agricultural frontiers. Here we tested the hypothesis that the time since land-use transition (age of frontier) and agricultural intensification also drive changes in the region’s fire regimes by reducing fire probability in both drought and non-drought years. We modeled fire probability as a function of the time since land-use transitions based on MapBiomas Project datasets from 1986 to 2020. We find that, while burned area declined as pasturelands aged and croplands advanced, deforestation abruptly increased fire activity before (Amazon: 4 years; Cerrado: 3 years) and after (Amazon: 8 years; Cerrado: 7 years) land clearing for pasture, especially in the Amazon. Additionally, the combination of ignition risk, drought, and air-dryness increased the likelihood of large extents of burned areas associated with deforestation. Incorporating frontier age as a proxy for governance in fire modeling is crucial, given the ecological implications of changing fire regimes despite declining rates of fire probability. Most importantly, protecting against deforestation and preserving native vegetation are vital.

Environmental Sciences & Ecology↗

Machine learning and artificial intelligence for wildfire prediction

Wildfire ignition, intensity, and spread rates are tightly linked with water cycle extremes. The science of wildfire prediction has traditionally encompassed the use of physical and empirical models to quantify the direction and speed of fire spread, plume injection and fire-aerosol impacts on atmospheric composition, predictions of fire season severity on subseasonal-to-seasonal (S2S) time scales, and assessment of the spatial and temporal patterns of fire risk across landscapes. Together with expanding observation networks, machine learning and artificial intelligence (AI) have the potential to revolutionize the application of such models for fire science, saving lives, protecting critical infrastructure, and providing more accurate estimates of wildfire-climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

The performance of lightweight plastic foams developed for fire safety

The use of a low density, polyurethane based foam to suppress a fire and to provide protection for the structure of an aircraft or spacecraft is discussed. The mechanism by which foams provide protection from heat and create a nonflammable surface is described. Various materials and their application to specific types of structures are examined.

Fish, R. H.↗

Safety and maintenance engineering: A compilation

A compilation is presented for the dissemination of information on technological developments which have potential utility outside the aerospace and nuclear communities. Safety of personnel engaged in the handling of hazardous materials and equipment, protection of equipment from fire, high wind, or careless handling by personnel, and techniques for the maintenance of operating equipment are reported.

Source record↗

Foam composite structures

The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

Delano, C. B.↗

Contrasting Patterns of Damage and Recovery in Logged Amazon Forests From Small Footprint LiDAR Data

Tropical forests ecosystems respond dynamically to climate variability and disturbances on time scales of minutes to millennia. To date, our knowledge of disturbance and recovery processes in tropical forests is derived almost exclusively from networks of forest inventory plots. These plots typically sample small areas (less than or equal to 1 ha) in conservation units that are protected from logging and fire. Amazon forests with frequent disturbances from human activity remain under-studied. Ongoing negotiations on REDD+ (Reducing Emissions from Deforestation and Forest Degradation plus enhancing forest carbon stocks) have placed additional emphasis on identifying degraded forests and quantifying changing carbon stocks in both degraded and intact tropical forests. We evaluated patterns of forest disturbance and recovery at four -1000 ha sites in the Brazilian Amazon using small footprint LiDAR data and coincident field measurements. Large area coverage with airborne LiDAR data in 2011-2012 included logged and unmanaged areas in Cotriguacu (Mato Grosso), Fiona do Jamari (Rondonia), and Floresta Estadual do Antimary (Acre), and unmanaged forest within Reserva Ducke (Amazonas). Logging infrastructure (skid trails, log decks, and roads) was identified using LiDAR returns from understory vegetation and validated based on field data. At each logged site, canopy gaps from logging activity and LiDAR metrics of canopy heights were used to quantify differences in forest structure between logged and unlogged areas. Contrasting patterns of harvesting operations and canopy damages at the three logged sites reflect different levels of pre-harvest planning (i.e., informal logging compared to state or national logging concessions), harvest intensity, and site conditions. Finally, we used multi-temporal LiDAR data from two sites, Reserva Ducke (2009, 2012) and Antimary (2010, 2011), to evaluate gap phase dynamics in unmanaged forest areas. The rates and patterns of canopy gap formation at these sites illustrate potential issues for separating logging damages from natural forest disturbances over longer time scales. Multi-temporal airborne LiDAR data and coincident field measurements provide complementary perspectives on disturbance and recovery processes in intact and degraded Amazon forests. Compared to forest inventory plots, the large size of each individual site permitted analyses of landscape-scale processes that would require extremely high investments to study using traditional forest inventory methods.

Morton, D. C.↗

The NASA Firefighter's Breathing System Program: A Status Report

The National Aeronautics and Space Administration (NASA), through its Technology Utilization Program, has been making its advanced technology developments available to the public. This has coincided in recent years with a growing demand within the fire service for improved protective equipment. A better breathing system for firefighters was one of the more immediate needs identified by the firefighting organizations. The Johnson Space Center (JSC), based upon their experience in providing life support systems for space flight, was subsequently requested to determine the feasibility of providing an improved breathing system for firefighters. Such a system was determined to be well within the current state of the art, and the Center is well into a development program to provide design verification of this improved protective' equipment. This report - outlines the overall objectives of this program, progress to date, and future planned activities.

McLaughlan, Pat B.↗

The gathering firestorm in southern Amazonia

Wildfires, exacerbated by extreme weather events and land use, threaten to change the Amazon from a net carbon sink to a net carbon source. Here, we develop and apply a coupled ecosystem-fire model to quantify how greenhouse gas–driven drying and warming would affect wildfires and associated CO2 emissions in the southern Brazilian Amazon. Regional climate projections suggest that Amazon fire regimes will intensify under both low- and high-emission scenarios. Our results indicate that projected climatic changes will double the area burned by wildfires, affecting up to 16% of the region’s forests by 2050. Although these fires could emit as much as 17.0 Pg of CO2 equivalent to the atmosphere, avoiding new deforestation could cut total net fire emissions in half and help prevent fires from escaping into protected areas and indigenous lands. Aggressive efforts to eliminate ignition sources and suppress wildfires will be critical to conserve southern Amazon forests.

P. M. Brando↗

Using Soil Moisture Information to Better Understand and Predict Wildfire Danger: A Review of Recent Developments and Outstanding Questions

Soil moisture conditions are represented in fire danger rating systems mainly through simple drought indices based on meteorological variables, even though better sources of soil moisture information are increasingly available. This review summarises a growing body of evidence indicating that greater use of in situ, remotely sensed, and modelled soil moisture information in fire danger rating systems could lead to better estimates of dynamic live and dead herbaceous fuel loads, more accurate live and dead fuel moisture predictions, earlier warning of wildfire danger, and better forecasts of wildfire occurrence and size. Potential uses of soil moisture information in existing wildfire danger rating systems include (1) as a supplement or replacement for drought indices, (2) for live and (3) dead fuel moisture modelling, (4) for estimating herbaceous fuel curing, and (5) for estimating fuel loads. We identify key remaining research questions and note the logistical challenge of convincing wildfire professionals of the importance of soil moisture compared with more familiar wildfire danger metrics. While obstacles remain, the path forward is clear. Soil moisture information can and should be used to improve fire danger rating systems and contribute to more effective fire management for the protection of communities and ecosystems worldwide.

fuel properties↗

Spacecraft Fire Safety: A Human Space Flight Program Perspective

This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

Pedley, Michael D.↗

National Renewable Energy Laboratory Wildland Fire Management Plan (August 2022-August 2025): February-August 2022

The National Renewable Energy Laboratory (NREL) is located in a moderate wildfire risk region. The region has a history of damaging wildland fire activity and is also susceptible to changing environmental conditions (drought, elevated temperatures) that may lead to an increase in wildfire frequency and consequence over time. An integrated, site-wide wildland fire management plan is required by the Department of Energy and is to be consistent with the Federal Wildland Fire Management Policy. The NREL Wildland Fire Management Plan (WFMP) provides an integrated approach to reducing risk to wildland fire at NREL. The goals of the WFMP are to protect human health and safety, protect NREL facilities and research, enhance community protection, diminish risk and consequences of wildland fires, and maintain the health of the ecosystem. The WFMP accomplishes these goals through the use of tools such as fire behavior modeling, fire growth modeling, a structure ignition risk assessment, and through the application of robust fire prevention, emergency management, and environmental programs. The NREL WFMP was developed in a collaborative manner with input from regional stakeholders including cities, counties, local fire departments, and other governmental agencies. The WFMP provides for recommendations to reduce overall wildland fire risk to life safety and property at NREL.

54 ENVIRONMENTAL SCIENCES↗

Firefighters Integrated Response Equipment System

The Firefighters Integrated Response Equipment System (Project FIRES) is a joint National Fire Prevention and Control Administration (NFPCA)/National Aeronautics and Space Administration (NASA) program for the development of an 'ultimate' firefighter's protective ensemble. The overall aim of Project FIRES is to improve firefighter protection against hazards, such as heat, flame, smoke, toxic fumes, moisture, impact penetration, and electricity and, at the same time, improve firefighter performance by increasing maneuverability, lowering weight, and improving human engineering design of his protective ensemble.

Kaplan, H.↗

Aircraft Seat Cushion Fire-Blocking Layers

229-page report describes work done to determine burning characteristics of present and proposed seat-cushion materials and types of construction. Tested cushions classified in four groups: standard cushion construction, standard cushion construction with protective covering enveloping urethane-foam core, standard cushion construction with protective covering enveloping non-fire-retarded urethane-foam core, and standard cushion construction with urethane-foam core replaced by advanced fire-resistant foam. Report includes still photographs and presents quantitative data from each test in graphs and tables.

Schutter, Kenneth J.↗

Radiation Effects on Line Heat Detection Cable AP Hot Cells Fire Detection at Brookhaven National Laboratory

Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.

36 MATERIALS SCIENCE↗