Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS METER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Utilitarian models of the solar nebula

Models of the primitive solar nebula based on a combination of theory, observations of T Tauri stars, and global conservation laws are presented. The models describe the motions of nebular gas, mixing of interstellar material during the formation of the nebula, and evolution of thermal structure in terms of several characteristic parameters. The parameters describe key aspects of the protosolar cloud (its rotation rate and collapse rate) and the nebula (its mass relative to the Sun, decay time, and density distribution). For most applications, the models are heuristic rather than predicted. Their purpose is to provide a realistic context for the interpretation of solar system data, and to distinquish those nebular characteristics that can be specified with confidence, independently of the assumtions of particular models, form those that are poorly constrained. It is demonstrated that nebular gas typically experienced large radial excursions during the evolution of the nebula and that both inward and outward mean radial velocities on the order of meters per second occured in the terrestrial planet region, with inward velocities predominant for most ofthe evolution. However, the time history of disk size, surface density, and radial velocities are sensitive to the total angular momentun of the protosolar cloud, which cannot be constrained by purely theoretical considerations.It is shown that a certain amount of 'formational' mixing of interstellar material was an inevitable consequenc of nebular mass and angular momentum transport during protostellar collapse, regardless of the specific transport mechanisms invloved. Even if the protosolar cloud was initially homogeneous, this mixing was important because it had the effect of mingling presolar material that had experienced different degrees of thermal processing during collapse and passage through the accertion shock. Nebular thermal structure is less sensitive to poorly constrained parameters than is dynamical history. A simple criterion is derived for the condition that silicate grains are evaporated at midplane, and it is argued that this condition was probably fulfilled early in nebular history. Cooling of a hot nebula due tocoagulation of dust and consequent local reduction of optical depth is examined, and it is shown how such a process leads naturally to an enrichment of rock-forming elements in the gas phase.

Cassen, Patrick↗

A research on integrated-circuit sensors for gas chromatography

Fabrication of a miniature gas chromatograph column using integrated circuit technology was studied and found to be feasible. A bonding problem of forming a strong, gas tight seal between two wafers of silicon has prevented the completion of the column design. Continuing research using tin or a chromium-gold bond promises to overcome the problems of using the proposed gold-eutectic bond. Specifications for the miniature gas chromatograph column are: a spiral capillary column of semi-circular cross section, 30 micron radius, and a total length of 6.9 meters etched into a silicon structure 50 mm in diameter and 0.625 mm thick.

Source record↗

Probe Measures Fouling As In Heat Exchangers

Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.

Marner, Wilbur J.↗

Investigation of Transient Gas Phase Column Density Due to Droplet Evaporation

A NASA robotic refueling mission experiment on board the International Space Station (ISS) was designed to repeatedly transfer simulated cryogenic propellant between two dewars. After each metered transfer, the cryogen was to be vented overboard via sublimation or evaporation. ISS payload providers must conduct analyses to demonstrate that any planned gaseous venting generate no more than a certain level of material that may interfere with optical measurements from other payloads that may be located nearby. This requirement is expressed in terms of a maximum column number density (CND). For the experiment under consideration, fluid droplets likely would accompany any such vapor. Earlier related studies led to development of analytical expressions for column density along general paths for a number of practical cases under steady conditions, including droplet evaporation. These expressions are not appropriate for rapid evaporation of small droplets however, since the droplets cannot sustain mass flow rates consistent with steady conditions. In this work, analytical expressions are developed for estimating column density near a rapidly evaporating droplet along general paths. The influence for instantaneous evaporation is created first as a limiting case, where it is found the peak value occurs at the time it takes a wave of vapor to reach the closest point along the optical path traveling at its most probable thermal speed. Next, the case for finite-period evaporation is evaluated for constant conditions. Compared to the instantaneous case, peak column density occurs shortly after droplet extinction, but at a lower intensity. A new mathematical function is discovered that solves the integrals associated with this case. Finally, ways to account for droplet motion and changes in evaporation rate with size and temperature are discussed in this framework.

Woronowicz, M. S.↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

Evaluation of a simplified gross thrust calculation technique using two prototype F100 turbofan engines in an altitude facility

The technique which relies on afterburner duct pressure measurements and empirical corrections to an ideal one dimensional flow analysis to determine thrust is presented. A comparison of the calculated and facility measured thrust values is reported. The simplified model with the engine manufacturer's gas generator model are compared. The evaluation was conducted over a range of Mach numbers from 0.80 to 2.00 and at altitudes from 4020 meters to 15,240 meters. The effects of variations in inlet total temperature from standard day conditions were explored. Engine conditions were varied from those normally scheduled for flight. The technique was found to be accurate to a twice standard deviation of 2.89 percent, with accuracy a strong function of afterburner duct pressure difference.

Kurtenbach, F. J.↗

Measurement of recovery temperature on an airfoil in the Langley 0.3-m transonic cryogenic tunnel

Experimental measurements of recovery temperature were made on an airfoil in the Langley 0.3-m Transonic Cryogenic Tunnel at Mach numbers of 0.60 and 0.84 over a Reynolds number per meter range from about 15,000,000 to about 335,000,000. The measured recovery temperatures were considerably below those associated with ideal-gas ambient temperature wind tunnels. This difference was accentuated as the stagnation pressure increased and the total temperature decreased. A boundary-layer code modified for use with cryogenic nitrogen adequately predicted the measured adiabatic wall temperature at all conditions. A quantitative, on-line assessment of the nonadiabatic condition of a model can be made during the operation of a cryogenic wind tunnel by using a correlation for the adiabatic wall temperature which is only a function of total temperature, total pressure, and local Mach number on the model.

Johnson, C. B.↗

Testing of fuel/oxidizer-rich, high-pressure preburners

Results of an evaluation of high pressure combustion of fuel rich and oxidizer rich LOX/RP-1 propellants using 4.0 inch diameter prototype preburner injectors and chambers are presented. Testing covered a pressure range from 8.9 to 17.5 MN/square meters (1292 to 2540 psia). Fuel rich mixture ratios ranged from 0.238 to 0.367; oxidizer rich mixture ratios ranged from 27.2 to 47.5. Performance, gas temperature uniformity, and stability data for two fuel rich and two ozidizer rich preburner injectors are presented for a conventional like-on-like (LOL) design and a platelet design injector. Kinetically limited combustion is shown by the excellent agreement of measured fuel rich gas composition and C performance data with kinetic model predictions. The oxidizer rich test results support previous equilibrium combustion predictions.

Lawver, B. R.↗

Two-Phase Quality/Flow Meter

A quality and/or flow meter employs a capacitance probe assembly for measuring the dielectric constant of flow stream, particularly a two-phase flow stream including liquid and gas components.ne dielectric constant of the flow stream varies depending upon the volume ratios of its liquid and gas components, and capacitance measurements can therefore be employed to calculate the quality of the flow, which is defined as the volume ratio of liquid in the flow to the total volume ratio of gas and liquid in the flow. By using two spaced capacitance sensors, and cross-correlating the time varying capacitance values of each, the velocity of the flow stream can also be determined. A microcontroller-based processing circuit is employed to measure the capacitance of the probe sensors.The circuit employs high speed timer and counter circuits to provide a high resolution measurement of the time interval required to charge each capacitor in the probe assembly. In this manner, a high resolution, noise resistant, digital representation of each of capacitance value is obtained without the need for a high resolution A/D converter, or a high frequency oscillator circuit. One embodiment of the probe assembly employs a capacitor with two ground plates which provide symmetry to insure that accurate measurements are made thereby.

Moerk, J. Steven↗

Mars In-Situ Resource Utilization Technology Evaluation

We have examined the technologies required to enable Mars Tn-Situ Resource Utilization (ISRU) because our understanding of Mars resources has changed significantly in the last five years as a result of recent robotic missions to the red planet [1-4]. Two major developments, (1) confirmation of the presence of near-surface water in the form of ice in very large amounts at high latitudes by the Phoenix Lander and (2) the likely existence of water at lower latitudes in the form of hydrates or ice in the top one meter of the regolith, have the potential to change ISRU technology selection. A brief technology assessment was performed for the most promising Mars atmospheric gas processing techniques: Reverse Water Gas Shift (RWGS) and Methanation (aka Sabatier), as well as an overview of soil.processing technology to extract water from Martian soil.

Santiago-Maldonado, Edgardo↗

Mars in Situ Resource Utilization Technology Evaluation

We have examined the technologies required to enable Mars In-Situ Resource Utilization (ISRU) because our understanding of Mars resources has changed significantly in the last five years as a result of recent robotic missions to the red planet. Two major developments, (1) confirmation of the presence of near-surface water in the form of ice in very large amounts at high latitudes by the Phoenix Lander and (2) the likely existence of water at lower latitudes in the form of hydrates or ice in the top one meter of the regolith, have the potential to change ISRU technology selection. A brief technology assessment was performed for the most promising Mars atmospheric gas processing techniques: Reverse Water Gas Shift (RWGS) and Methanation (aka Sabatier), as well as an overview of soil processing technology to extract water from Martian soil.

Muscatello, Anthony C.↗

Experimental investigation at Mach 8 of the effects of projections and cavities on heat transfer to a model of the Viking aeroshell

An experimental investigation into the aerodynamic heating on a Mars entry vehicle shape with several types of local surface distortion is presented. The configurations tested were 0.033-scale models of a spherically blunted 70 deg half-angle cone with two protuberances of different length, representing the tube leading to the gas chromograph mass spectrometer, and two aeroshell-bioshield attachment points of different size. These models were tested at free-stream Reynolds numbers per meter of 3.7 million and 17 million over an angle-of-attack range from 0 to 18 deg in the Langley Mach 8 variable density hypersonic tunnel. The phase change-coating technique was used to measure heat transfer coefficient. The long protuberance caused more severe interference heating than the short protuberance for the same conditions. When the short projection was located close to the edge of the aeroshell, the interference heating was greater than that on the same projection when located near the vertex. A significant increase in heat transfer coefficient was measured only on the larger aeroshell-bioshield attachment point.

Creel, T. R., Jr.↗

Sampling of Trace Atmospheric Constituents Above the Surface of Mars from a Montgolfiere Balloon

We suggest that use of an aerially deployed, solar-heated balloon, or Montgolfiere, during a Martian polar summer could provide an optimal platform for atmospheric measurements near the surface. Solar Montgolfieres are empty balloons with a hole in the bottom that fill with ambient atmosphere while failing and are rapidly heated in by the sun, thus providing buoyancy. Such a balloon would be driven by the Martian winds in the constant sunlight of a high latitude entry and could provide a traverse of thousands of kilometers. It would encircle the Martian north polar region over a period,likely lasting over one earth month, and its altitude could be controlled as low as 100 meters to as high as 4000 meters above the surface. The significant payload of tens of kilograms allowed by this technology could readily accommodate the mass of instrumentation and the power source needed for a sensitive search for disequilibrium species that might provide the atmospheric signature of localized subsurface biological or geological activity. A mass spectrometer used in combination with gas enrichment techniques can provide sensitivities to sub parts per billion for several species of interest. Additional highly specific and sensitive detectors can search for other species or measurements of their mixing ratio variation along the path of the balloon. It would be useful to combine these atmospheric measurements with electromagnetic sounding to search for variations in subsurface conductivity that might indicate the presence of subsurface water. After a month of operation, the balloon could also soft land the DBMS to provide additional data on soil samples from a 1-2 meter subsurface drill. In order to float a 30-kg payload at altitudes between 100 m and 4000 m above the Martian north polar surface, an aluminized polyethylene Montgolfiere would be approximately 29 meters in diameter and have a mass of 27 kg. Altitude variations could be accomplished by means of an upper vent to release hot gas, as has been tested at JPL, or be means of a simple, internal winch mechanism to decrease the volume of the balloon. JPL has successfully deployed three polyethylene Montgolfieres at 4-6 mbar pressure in the Earth's stratosphere and will be deploying a 20-m diameter polyethylene Montgolfiere later in 2001.

Jones, Jack A.↗

Performance of the 0.3-meter transonic cryogenic tunnel with air, nitrogen, and sulfur hexafluoride media under closed loop automatic control

The NASA Langley 0.3-m Transonic Cryogenic Tunnel was modified in 1994, to operate with any one of the three test gas media viz., air, cryogenic nitrogen gas, or sulfur hexafluoride gas. This document provides the initial test results with respect to the tunnel performance and tunnel control, as a part of the commissioning activities on the microcomputer based controller. The tunnel can provide precise and stable control of temperature to less than or equal to +/- 0.3 K in the range 80-320 K in cyro mode or 300-320 K in air/SF6 mode, pressure to +/- 0.01 psia in the range 15-88 psia and Mach number to +/- O.0015 in the range 0.150 to transonic Mach numbers up to 1.000. A new heat exchanger has been included in the tunnel circuit and is performing adequately. The tunnel airfoil testing benefits considerably by precise control of tunnel states and helps in generating high quality aerodynamic test data from the 0.3-m TCT.

Balakrishna, S.↗

Self-acting and hydrodynamic shaft seals

Self-acting and hydrodynamic seals are described. The analytical procedures are outlined for obtaining a seal force balance and the operating film thickness. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis revealed three different vibration modes. Proposed applications of self-acting seals in gas turbine engines and in rocket vehicle turbopumps are described. Also experimental data on self-acting face seals operating under simulated gas turbine conditions are given; these data show the feasibility of operating the seal at conditions of 345 newtons per square centimeter (500 psi) and 152 meters per second (500 ft/sec) sliding speed.

Ludwig, L. P.↗

Self-acting and hydrodynamic shaft seals.

Self-acting and hydrodynamic seals are described. The analytical procedures are outlined for obtaining a seal force balance and the operating film thickness. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis revealed three different vibration modes. Proposed applications of self-acting seals in gas turbine engines and in rocket vehicle turbopumps are described. Also experimental data on self-acting face seals operating under simulated gas turbine conditions are given; these data show the feasibility of operating the seal at conditions of 345 newtons per square centimeter (500 psi) and 152 meters per second (500 ft/sec) sliding speed.

Ludwig, L. P.↗

IRAS 14348-1447, an ultraluminous pair of colliding, gas-rich galaxies - The birth of a quasar?

Ground-baed observations of the object IRAS 14348-1447, which was discovered with the Infrared Astronomical Satellite, show that it is an extremely luminous colliding galaxy system that emits more than 95 percent of its energy at FIR wavelengths. IRAS 14348-1447, which is receeding from the sun at 8 percent of the speed of light, has a bolometric luminosity more than 100 times larger than that of the Galaxy, and is therefore as luminous as optical quasars. New optical, infrared, and spectroscopic measurements suggest that the dominant luminosity source is a dust-enshrouded quasar. The fuel for the intense activity is an enormous supply of molecular gas. Carbon monoxide emission has been detected at a wavelength of 2.6 millimeters by means of a new, more sensitive receiver recently installed on the 12-meter telescope of the National Radio Astronomy Observatory. IRAS 14348-1447 is the most distant and luminous source of carbon monoxide line emission yet detected.

Sanders, D. B.↗