Runtime and Pressurization Analyses of Propellant Tanks

Multi-element unstructured CFD has been utilized at NASA SSC to carry out analyses of propellant tank systems in different modes of operation. The three regimes of interest at SSC include (a) tank chill down (b) tank pressurization and (c) runtime propellant draw-down and purge. While tank chill down is an important event that is best addressed with long time-scale heat transfer calculations, CFD can play a critical role in the tank pressurization and runtime modes of operation. In these situations, problems with contamination of the propellant by inclusion of the pressurant gas from the ullage causes a deterioration of the quality of the propellant delivered to the test article. CFD can be used to help quantify the mixing and propellant degradation. During tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. It should be noted that traditional CFD modeling is inadequate for such simulations because the fluids in the tank are in a range of different sub-critical and supercritical states and elaborate phase change and mixing rules have to be developed to accurately model the interaction between the ullage gas and the propellant. We show a typical run-time simulation of a spherical propellant tank, containing RP-1 in this case, being pressurized with room-temperature nitrogen at 540 R. Nitrogen, shown in blue on the right-hand side of the figures, enters the tank from the diffuser at the top of the figures and impinges on the RP-1, shown in red, while the propellant is being continuously drained at the rate of 1050 lbs/sec through a pipe at the bottom of the tank. The sequence of frames in Figure 1 shows the resultant velocity fields and mixing between nitrogen and RP-1 in a cross-section of the tank at different times. A vortex is seen to form in the incoming nitrogen stream that tends to entrain propellant, mixing it with the pressurant gas. The RP-1 mass fraction contours in Figure 1 are also indicative of the level of mixing and contamination of the propellant. The simulation is used to track the propagation of the pure propellant front as it is drawn toward the exit with the evolution of the mixing processes in the tank. The CFD simulation modeled a total of 10 seconds of run time. As is seen from Figure 1d, after 5.65 seconds the propellant front is nearing the drain pipe, especially near the center of the tank. Behind this pure propellant front is a mixed fluid of compromised quality that would require the test to end when it reaches the exit pipe. Such unsteady simulations provide an estimate of the time that a high-quality propellant supply to the test article can be guaranteed at the modeled mass flow rate. In the final paper, we will discuss simulations of the LOX and propellant tanks at NASA SSC being pressurized by an inert ullage. Detailed comparisons will be made between the CFD simulations and lower order models as well as with test data. Conditions leading to cryo collapse in the tank will also be identified.

Field, Robert E.↗

Permeability of rayon based polymer composites

Several types of anomalous rayon based phenolic behavior have been observed in post-fired nozzles and exit cones. Many of these events have been shown to be related to the development of internal gas pressure within the material. The development of internal gas pressure is a function of the amount of gas produced within the material and the rate at which that gas is allowed to escape. The latter property of the material is referred to as the material's permeability. The permeability of two dimensional carbonized rayon based phenolic composites is a function of material direction, temperature, and stress/strain state. Recently significant differences in the permeability of these materials has been uncovered which may explain their inconsistent performance. This paper summarizes what is known about the permeability of these materials to date and gives possible implications of these finding to the performance of these materials in an ablative environment.

Stokes, E. H.↗

Pressure-Gain Combustion for Gas Turbines

Pressure Gain Combustion (PGC) is under investigation as a means to improve the thermal efficiency of gas turbines. PGC is a fundamentally unsteady combustion process which, through some means of confinement, raises the total pressure of the working fluid relative to the initial process state. When implemented as a gas turbine combustor it yields a total pressure gain across the device instead of the typical loss seen in a conventional combustor. This pressure gain can significantly improve gas turbine performance. This presentation is a modified and updated version of a 2018 tutorial of the same name. It is tailored to a graduate student audience that is familiar with the PGC concept, but has focused entirely on a specific type of implementation. It will provide a brief review of the concept of PGC and why it's important. The majority of the presentation will describe the various approaches to implementation that are under investigation by the PGC community. Emphasis will be on strategies other than the one that the students are investigating.

Combustion↗

Skin microvascular flow during hypobaric exposure with and without a mechanical counter-pressure space suit glove

INTRODUCTION: Current space suits are rigid, gas-pressurized shells that protect astronauts from the vacuum of space. A tight elastic garment or mechanical-counter-pressure (MCP) suit generates pressure by compression and may have several advantages over current space suit technology. In this study, we investigated local microcirculatory effects produced with and without a prototype MCP glove. METHODS: The right hand of eight normal volunteers was studied at normal ambient pressure and during exposure to -50, -100 and -150 mm Hg with and without the MCP glove. Measurements included the pressure against the hand, skin microvascular flow, temperature on the dorsum of the hand, and middle finger girth. RESULTS: Without the glove, skin microvascular flow and finger girth significantly increased with negative pressure, and the skin temperature decreased compared with the control condition. The MCP glove generated approximately 200 mm Hg at the skin surface; all measured values remained at control levels during exposure to negative pressure. DISCUSSION: Without the glove, skin microvascular flow and finger girth increased with negative pressure, probably due to a blood shift toward the hand. The elastic compression of the material of the MCP glove generated pressure on the hand similar to that in current gas-pressurized space suit gloves. The MCP glove prevented the apparent blood shift and thus maintained baseline values of the measured variables despite exposure of the hand to negative pressure.

NASA Discipline Cardiopulmonary↗

The dynamics and stability of radiatively driven gas clouds. I - Plane-parallel slabs

A combination of numerical and analytical techniques has been used to investigate the dynamics and stability of optically thin plane-parallel radiatively driven slabs of gas confined by the thermal gas pressure of a high-temperature low-density medium. Scaling laws allow the individual model 'clouds' to be characterized by a single free parameter, chi, a normalized column density which measures the strength of the acceleration due to radiation pressure relative to that due to thermal gas pressure. It is found that these clouds are stable and coherently accelerated only when chi is small. In this regime a simple slab model is constructed which accurately reproduces the more complex gasdynamic results. The low-chi clouds are marginally able to reach the high velocities seen in the atmospheres of quasi-stellar objects, but only if their motion is subsonic with respect to the external confining medium. This implies either that the medium is extremely hot and tenuous or that it is moving outward with the clouds.

Haas, M. R.↗

Anode-type double layers in a nonuniform magnetic field

The properties of strong, magnetized, three-dimensional double layers are studied. The double layers are produced by drawing a discharge to a large anode plate located in the diverging magnetic field region of a cylindrical argon discharge. If the anode voltage is sufficiently high, the electrons that are accelerated through the anode sheath may become sufficiently energetic to ionize the background neutral gas and transform the anode sheath into a strong double layer. The resulting conical-shaped structures, which extend outward from the plate, have parallel, oblique, and perpendicular electric field components with respect to the magnetic field. The axial extent of these structures depends on the plate bias voltage, neutral gas pressure, and the magnetic field. At neutral gas pressures of a few millitorr, the double-layer structures are visually apparent because of the enhanced light emission from neutrals excited by the energetic electrons. Color photographs of some of these structures are shown. The scaling of the width of these double layers with electric field components perpendicular to B is also investigated.

Cartier, Steven L.↗

Pressure-Gain Combustion for Gas Turbines

Pressure Gain Combustion (PGC) is under investigation as a means to improve the thermal efficiency of gas turbines. PGC is a fundamentally unsteady combustion process which, through some means of confinement, raises the total pressure of the working fluid relative to the initial process state. When implemented in a combustor it yields a total pressure gain across the device instead of the typical loss seen in a conventional combustor. This pressure gain can significantly improve gas turbine performance. The tutorial will provide an introduction to the concept of PGC. It will begin with a process description in fundamental thermodynamic terms, and will quantify potential benefits. The majority of the presentation will describe the various approaches to implementation that are under investigation by the PGC.

Paxson, Dan↗

Langmuir Probe Measurements of Inductively Coupled Plasmas in CF4/Ar/O2 Mixtures

Fluorocarbon gases, such as CF4, and their mixtures are widely used in contemporary low-pressure and high-density plasma processing techniques. In such plasmas Langmuir probe is one of the most commonly employed diagnostic techniques to obtain electron number density (ne), electron temperature (Te), electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp). In this paper we report probe data for planar inductively coupled plasmas in CF4/O2/Ar mixtures. By varying the relative concentrations in the mixture, radial profiles of ne, ni, Te, Ee, Vp, EEDF were measured in the mid-plane of the plasma at 10 mTorr and 20 mTorr of gas pressures, and 200 W and 300 W of RF powers. Data show that ne and ni decrease with increase of CF4 content and decrease of gas-pressure but they increase with increase of RF-power, whereas Vp increases with decrease of gas-pressure and remains independent of RF-power. However, they all peak at the center of the plasma and decrease towards the edge while Te follows the other way and increases a little with increase of power. The measured EEDFs exhibit Druyvesteyn-like distribution at all pressures and powers. Data are analyzed and will be presented.

Rao, M. V. V. S.↗

Nonlinear evolution of magnetic flux ropes. 2: Finite beta plasma

In this second paper on the evolution of magnetic flux ropes we study the effects of gas pressure. We assume that the energy transport is described by a polytropic relationship and reduce the set of ideal MHD equations to a single, second-order, nonlinear, ordinary differential equation for the evolution function. For this conservative system we obtain a first integral of motion. To analyze the possible motions, we use a mechanical analogue -- a one-dimensional, nonlinear oscillator. We find that the effective potential for such an oscillator depends on two parameters: the polytropic index gamma and a dimensionless quantity kappa the latter being a function of the plasma beta, the strength of the azimuthal magnetic field relative to the axial field of the flux rope, and gamma. Through a study of this effective potential we classify all possible modes of evolution of the system. In the main body of the paper, we focus on magnetic flux ropes whose field and gas pressure increase steadily towards the symmetry axis. In this case, for gamma greater than 1 and all values of kappa, only oscillations are possible. For gamma less than 1, however, both oscillations and expansion are allowed. For gamma less than 1 and kappa below a critical value, the energy of the nonlinear oscillator determines whether the flux rope will oscillate or expand to infinity. For gamma less than 1 and kappa above critical, however, only expansion occurs. Thus by increasing kappa while keeping gamma fixed (less than 1), a phase transition occurs at kappa = kappa(sub critical) and the oscillatory mode disappears. We illustrate the above theoretical considerations by the example of a flux rope of constant field line twist evolving self-similarly. For this example, we present the full numerical MHD solution. In an appendix to the paper we catalogue all possible evolutions when (1) either the magnetic field or (2) the gas pressure decreases monotonically toward the axis. We find that in these cases critical conditions can occur for gamma greater than 1. While in most cases the flux rope collapses, there are notable exceptions when, for certain ranges of kappa and gamma, collapse may be averted.

Osherovich, V. A.↗

Blood-Pressure Measuring System Gives Accurate Graphic Output

The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

Source record↗

The interstellar medium in the starburst regions of NGC 253 and NGC 3256

We discuss observations of the (C II) 158 micrometers, (O I) 63 micrometers, (Si II) 35 micrometers, (O III) 52,88 micrometers, and (S III) 33 micrometers fine-structure transitions toward the central 45 seconds of the starburst galaxies NGC 253 and NGC 3256. The (C II) and (O I) emission probably originates in photodissociated gas at the surfaces of molecular clouds, although a small (less than or approximately 30%) contribution to the (C II) flux from H II regions cannot be ruled out. The (O III) and (S III) lines originate in H II regions and the (Si II) flux is best explained as originating in H II regions with some contribution from photodissociation regions (PDRs). The gas phase silicon abundance is nearly solar in NGC 253, which we interpret as evidence for grain destruction in the starburst region. We find that the photodissociated atomic gas has densities approximately 10(exp 4)/cu cm and temperature 200-300 K. About 2% of the gas is in this phase. The thermal gas pressure in the PDRs, P(PDR)/k approximately 1-3 x 10(exp 6) K/cu cm, might represent the 'typical' interstellar gas pressure in starburst systems. The Far Ultraviolet (FUV) radiation fields illuminating the clouds are 10(exp 3)-10(exp 4) stronger than the local Galactic FUV field and come from the contribution of many closely packed O and B stars. For the central 250 pc of NGC 253, we find that the H II gas has an average density n(sub e) is approximately 400/cu cm. This corresponds to a thermal pressure P(H II)/k approximately 7 x 10(exp 6) K/cu cm which is approximately P(PDR)/k, suggesting that the ionized gas is in pressure equilibrium with the photodissociated gas at the surfaces of molecular clouds. The H II gas fills a significant fraction, approximately 0.01-0.3, of the volume between the clouds. The effective temperature of the ionizing stars in NGC 253 is greater than or approximately 34,500 K; 2 x 10(exp 5) O7.5 stars would produce the observed Lyman countinuum photon luminosity. The average separation between the stars is approximately 3 pc. Applying the simple model for the interstellar medium in galactic nuclei of Wolfire, Tielens, & Hollenbach (1990), we find the molecular gas in the central regions of NGC 253 and NGC 3256 to be distributed in a large number (5 x 10(exp 3) to 5 x 10(exp 5)) of small (0.5-2 pc), dense (approximately 10(exp 4)/cu cm) clouds (or alternatively 'thin-flattened' structures) with volume filling factors 10(exp -3) to 10(exp -2), very different from the local Interstellar Medium (ISM) of the Galaxy. We suggest a self-consistent scenario for the ISM in NGC 253 in which clouds and H II gas are in pressure balance with a supernova-shocked, hot 1-3 x 10(exp 6) K, low-density (approximately 10(exp 4)/cu cm), all pervasive medium. A feedback mechanism may be indicated in which the pressure generated by the supernovae compresses the molecular clouds and triggers further massive star formation. The similarity of ISM parameters deduced for NGC 253, NGC 3256, and M82 (Lord et al. 1993) suggests that the ISM properties are independent of the luminosity of the starburst or the triggering mechanism, but are rather endemic to starburst systems. The starburst in NGC 3256 appears to be a scaled-up version of the NGC 253 and M82 starbursts.

Carral, P.↗

SiC fiber analysis

Polymer derived Nicalon SiC fibers are known to be thermally unstable at temperatures beyond 1200 C. In an effort to further understand the mechanisms of fiber degradation, Nicalon fibers were heat treated at temperatures up to 2200 C and argon gas pressures varying from 0 to 1360 atm. The effects of gas pressure on the thermal stability of the fibers were determined through property comparisons between the pressure-treated fibers and vacuum-treated fibers. Investigation of the thermal stability included studies of the fiber microstructure and mechanical and physical properties before and after treatments.

Jaskowiak, Martha H.↗

Resistively Heated SiC Nozzle for Generating Molecular Beams

An improved nozzle has been developed to replace nozzles used previously in an apparatus that generates a substantially unidirectional beam of molecules passing through a vacuum at speeds of several kilometers per second. The basic principle of operation of the apparatus is the same for both the previous and the present nozzle designs. The main working part of the nozzle is essentially a cylinder that is closed except that there is an inlet for a pressurized gas and, at one end, the cylinder is closed by a disk that contains a narrow central hole that serves as an outlet. The cylinder is heated to increase the thermal speeds of the gas molecules into the desired high-speed range. Heated, pressurized gas escapes through the outlet into a portion of the vacuum chamber that is separated, by a wall, from the rest of the vacuum chamber. In this portion of the vacuum chamber, the gas undergoes a free jet expansion. Most of the expanded gas is evacuated and thus does not become part of the molecular beam. A small fraction of the expanded beam passes through a narrow central orifice in the wall and thereby becomes a needle- thin molecular beam in the portion of the vacuum on the downstream side of the wall.

Cagiano, Steven↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument, requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in a folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system, and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable to support the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid one. The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121C was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The tests provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has been carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable of supporting the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid on The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121 deg Celcius was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The test provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has be carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

Defect Density Characterization of Detached-Grown Germanium Crystals

Several (111)-oriented, Ga-doped germanium crystals were grown in pyrolytic boron nitride (pBN) containers by the Bridgman and the detached Bridgman growth techniques. Growth experiments in closed-bottom pBN containers resulted in nearly completely detached-grown crystals, because the gas pressure below the melt can build up to a higher pressure than above the melt. With open-bottom tubes the gas pressure above and below the melt is balanced during the experiment, and thus no additional force supports the detachment. In this case the crystals grew attached to the wall. Etch pit density (EPD) measurements along the axial growth direction indicated a strong improvement of the crystal quality of the detached-grown samples compared to the attached samples. Starting in the seed with an EPD of 6-8 x 10(exp 3)/square cm it decreased in the detached-grown crystals continuously to about 200-500/square cm . No significant radial difference between the EPD on the edge and the middle of the crystal exists. In the attached grown samples the EPD increases up to a value of about 2-4 x 10(exp 4)/square cm (near the edge) and up to 1 x 10(exp 4)/square cm in the middle of the sample. Thus the difference between the detached- and the attached-grown crystals with respect to the EPD is approximately two orders of magnitude.

Schweizer, M.↗

Gas storage using fullerene based adsorbents

This invention is directed to the synthesis of high bulk density high gas absorption capacity adsorbents for gas storage applications. Specifically, this invention is concerned with novel gas absorbents with high gravimetric and volumetric gas adsorption capacities which are made from fullerene-based materials. By pressing fullerene powder into pellet form using a conventional press, then polymerizing it by subjecting the fullerene to high temperature and high inert gas pressure, the resulting fullerene-based materials have high bulk densities and high gas adsorption capacities. By pre-chemical modification or post-polymerization activation processes, the gas adsorption capacities of the fullerene-based adsorbents can be further enhanced. These materials are suitable for low pressure gas storage applications, such as oxygen storage for home oxygen therapy uses or on-board vehicle natural gas storage. They are also suitable for storing gases and vapors such as hydrogen, nitrogen, carbon dioxide, and water vapor.

Loutfy, Raouf O.↗

Demonstration of Hazardous Hypervelocity Test Capability

NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) participated in a joint test program with NASA JSC Hypervelocity Impact Research Laboratory (HIRL) to determine if JSC was capable of performing hypervelocity impact tests on hazardous targets. Seven pressurized vessels were evaluated under hypervelocity impact conditions. The vessels were tested with various combinations of liquids and gasses at various pressures. Results from the evaluation showed that vessels containing 100-percent pressurized gas sustained more severe damage and had a higher potential for damaging nearby equipment, than vessels containing 75-percent liquid, 25-percent inert pressurized gas. Two water-filled test vessels, one of which was placed behind an aluminum shield, failed by bulging and splitting open at the impact point; pressure was relieved without the vessel fragmenting or sustaining internal damage. An additional water-filled test vessel, placed a greater distance behind an aluminum shield, sustained damage that resembled a shotgun blast, but did not bulge or split open; again, pressure was relieved without the vessel fragmenting. Two test vessels containing volatile liquids (nitro methane and hydrazine) also failed by bulging and splitting open; neither liquid detonated under hypervelocity test conditions. A test vessel containing nitrogen gas failed by relieving pressure through a circular entry hole; multiple small penetrations opposite the point of entry provided high velocity target debris to surrounding objects. A high-pressure oxygen test vessel fragmented upon impact; the ensuing fire and high velocity fragments caused secondary damage to surrounding objects. The results from the evaluation of the pressurized vessels indicated that JSC is capable of performing hypervelocity impact tests on hazardous targets.