Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Online elemental analysis of process gases with ICP-OES: A case study on waste wood combustion

Highlights: Black-Right-Pointing-Pointer Simultaneous measurements of 23 elements in process gases of a waste wood combustor. Black-Right-Pointing-Pointer Mobile ICP spectrometer allows measurements of high quality at industrial plants. Black-Right-Pointing-Pointer Continuous online measurements with high temporal resolution. Black-Right-Pointing-Pointer Linear correlations among element concentrations in the raw flue gas were detected. Black-Right-Pointing-Pointer Novel sampling and calibration methods for ICP-OES analysis of process gases. - Abstract: A mobile sampling and measurement system for the analysis of gaseous and liquid samples in the field was developed. An inductively coupled plasma optical emission spectrometer (ICP-OES), which is built into a van, was used as detector. The analytical system was calibrated with liquid and/or gaseous standards. It was shown that identical mass flows of either gaseous or liquid standards resulted in identical ICP-OES signal intensities. In a field measurement campaign trace and minor elements in the raw flue gas of a waste wood combustor were monitored. Sampling was performed with a highly transport efficient liquid quench system, which allowed to observe temporal variations in the elemental process gas composition. After a change in feedstock an immediate change of the element concentrations in the flue gas was detected. A comparison of the average element concentrations during the combustion of the two feedstocks showed a high reproducibility for matrix elements that are expected to be present in similar concentrations. On the other hand elements that showed strong differences in their concentration in the feedstock were also represented by a higher concentration in the flue gas. Following the temporal variations of different elements revealed strong correlations between a number of elements, such as chlorine with sodium, potassium and zinc, as well as arsenic with lead, and calcium with strontium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave-Assisted Synthesis of Perovskite SrSnO 3 Nanocrystals in Ionic Liquids for Photocatalytic Applications

Nanosized SrSnO 3 photocatalysts have been successfully synthesized by microwave synthesis in various ionic liquids (ILs) followed by a heat treatment process to optimize the materials’ crystallinity. The influence of the ILs with various cations such as 1-butyl-3-methylimidazolium ([C 4 mim] + ), 6-bis(3-methylimidazolium-1-yl)hexane ([C 6 (mim) 2 ] 2+ ), butylpyridinium ([C 4 Py] + ), and tetradecyltrihexylphosphonium ([P 66614 ] + ) and bis(trifluoromethanesulfonyl)amide ([Tf 2 N] - ) as the anion on the structure, crystallization, and morphology of the products was investigated. The samples were characterized by X-ray diffraction (XRD), thermogravimetry (TG), scanning electron microscopy (SEM), surface area analysis by gas adsorption, X-ray photoelectron spectroscopy (XPS), diffuse reflectance UV–vis spectroscopy, and Raman and IR spectroscopy. According to structure characterization by XRD and Raman spectroscopy all samples crystallized phase-pure in the orthorhombic GdFeO 3 perovskite structure type. SEM reveals that, on the basis of the IL, the obtained SrSnO 3 nanoparticles exhibit different morphologies and sizes. Rod-shaped particles are formed in [C 4 mim][Tf 2 N], [C 6 (mim) 2 ][Tf 2 N] 2 , and [P 66614 ][Tf 2 N]. However, the particle dimensions and size distribution vary depending on the IL and range from quite thin and long needlelike particles with a narrow size distribution obtained in [P 66614 ][Tf 2 N] to relatively larger particles with a broader size distribution obtained in [C 6 (mim) 2 ][Tf 2 N] 2 . In contrast, in [C 4 Py][Tf 2 N] nanospheres with a diameter of about 50 nm form. For these particles the highest photocatalytic activity was observed. Our investigations indicate that the improved photocatalytic activity of this material results from the synergistic effect of the relatively large surface area associated with nanosize and an appropriate energy band structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Partitioning of mercury, arsenic, selenium, boron, and chloride in a full-scale coal combustion process equipped with selective catalytic reduction, electrostatic precipitation, and flue gas desulfurization systems

A full-scale field study was carried out at a 795 MWe coal-fired power plant equipped with selective catalytic reduction (SCR), an electrostatic precipitator (ESP), and wet flue gas desulfurization (FGD) systems to investigate the distribution of selected trace elements (i.e., mercury, arsenic, selenium, boron, and chloride) from coal, FGD reagent slurry, makeup water to flue gas, solid byproduct, and wastewater streams. Flue gases were collected from the SCR outlet, ESP inlet, FGD inlet, and stack. Concurrent with flue gas sampling, coal, bottom ash, economizer ash, and samples from the FGD process were also collected for elemental analysis. By combining plant operation parameters, the overall material balances of selected elements were established. The removal efficiencies of As, Se, Hg, and B by the ESP unit were 88, 56, 17, and 8%, respectively. Only about 2.5% of Cl was condensed and removed from flue gas by fly ash. The FGD process removed over 90% of Cl, 77% of B, 76% of Hg, 30% of Se, and 5% of As. About 90% and 99% of the FGD-removed Hg and Se were associated with gypsum. For B and Cl, over 99% were discharged from the coal combustion process with the wastewater. Mineral trona (trisodium hydrogendicarbonate dehydrate, Na{sub 3}H(CO{sub 3}){sub 2}.2H{sub 2}O) was injected before the ESP unit to control the emission of sulfur trioxide (SO{sub 3}). By comparing the trace elements compositions in the fly ash samples collected from the locations before and after the trona injection, the injection of trona did not show an observable effect on the partitioning behaviors of selenium and arsenic, but it significantly increased the adsorption of mercury onto fly ash. The stack emissions of mercury, boron, selenium, and chloride were for the most part in the gas phase. 47 refs., 3 figs., 11 tabs.

01 COAL, LIGNITE, AND PEAT↗

EFFECTS OF TRITIUM GAS EXPOSURE ON THE GLASS TRANSITION TEMPERATURE OF EPDM ELASTOMER AND ON THE CONDUCTIVITY OF POLYANILINE

Four formulations of EPDM (ethylene-propylene diene monomer) elastomer were exposed to tritium gas initially at one atmosphere and ambient temperature for between three and four months in closed containers. Material properties that were characterized include density, volume, mass, appearance, flexibility, and dynamic mechanical properties. The glass transition temperature was determined by analysis of the dynamic mechanical property data per ASTM standards. EPDM samples released significant amounts of gas when exposed to tritium, and the glass transition temperature increased by about 3 C. during the exposure. Effects of ultraviolet and gamma irradiation on the surface electrical conductivity of two types of polyaniline films are also documented as complementary results to planned tritium exposures. Future work will determine the effects of tritium gas exposure on the electrical conductivity of polyaniline films, to demonstrate whether such films can be used as a sensor to detect tritium. Surface conductivity was significantly reduced by irradiation with both gamma rays and ultraviolet light. The results of the gamma and UV experiments will be correlated with the tritium exposure results.

36 MATERIALS SCIENCE↗

Position-specific carbon isotope analysis of serine by gas chromatography/Orbitrap mass spectrometry, and an application to plant metabolism

Position-specific 13 C/ 12 C ratios within amino acids remain largely unexplored in environmental samples due to methodological limitations. We hypothesized that natural-abundance isotope patterns in serine may serve as a proxy for plant metabolic fluxes including photorespiration. Here we describe an Orbitrap method optimized for the position-specific carbon isotope analysis of serine to test our hypothesis and discuss the generalizability of this method to other amino acids. Position-specific carbon isotope ratios of serine were measured using a Thermo Scientific™ Q Exactive™ GC Orbitrap™. Amino acids were hydrolyzed from Arabidopsis biomass, purified from potential matrix interferences, and derivatized alongside standards. Derivatized serine (N,O-bis(trifluoroacetyl)methyl ester) was isolated using gas chromatography, trapped in a reservoir, and purged into the electron ionization source over tens of minutes, producing fragment ions containing different combinations of atoms from the serine-derivative molecule. The 13 C/ 12 C ratios of fragments with monoisotopic masses of 110.0217, 138.0166, and 165.0037 Da were monitored in the mass analyzer and used to calculate position-specific δ 13 C values relative to a working standard. This methodology constrains position-specific δ 13 C values for nanomole amounts of serine isolated from chemically complex mixtures. The δ 13 C values of fragment ions of serine were characterized with ≤1‰ precisions, leading to propagated standard errors of 0.7–5‰ for each carbon position. Position-specific δ 13 C values differed by up to ca 28 ± 5‰ between serine molecules hydrolyzed from plants grown under contrasting pCO 2 , selected to promote different fluxes through photosynthesis and photorespiration. The method was validated using pure serine standards characterized offline. Here this study presents the first Orbitrap-based measurements of natural-abundance, position-specific carbon isotope variation in an amino acid isolated from a biological matrix. We present a method for the precise characterization of isotope ratios in serine and propose applications probing metabolism in plants. We discuss the potential for extending these approaches to other amino acids, paving the way for novel applications.

59 BASIC BIOLOGICAL SCIENCES↗

Factors influencing moisture analysis in the 3013 destructive examination surveillance program

Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

3013↗

RADIAL DISTRIBUTION OF STARS, GAS, AND DUST IN SINGS GALAXIES. II. DERIVED DUST PROPERTIES

We present a detailed analysis of the radial distribution of dust properties in the SINGS sample, performed on a set of ultraviolet (UV), infrared (IR), and H I surface brightness profiles, combined with published molecular gas profiles and metallicity gradients. The internal extinction, derived from the total-IR (TIR)-to-far-UV (FUV) luminosity ratio, decreases with radius, and is larger in Sb-Sbc galaxies. The TIR-to-FUV ratio correlates with the UV spectral slope {beta}, following a sequence shifted to redder UV colors with respect to that of starbursts. The star formation history (SFH) is identified as the main driver of this departure. Both L {sub TIR}/L {sub FUV} and {beta} correlate well with metallicity, especially in moderately face-on galaxies. The relation shifts to redder colors with increased scatter in more edge-on objects. By applying physical dust models to our radial spectral energy distributions, we have derived radial profiles of the total dust mass surface density, the fraction of the total dust mass contributed by polycyclic aromatic hydrocarbons (PAHs), and the intensity of the radiation field heating the grains. The dust profiles are exponential, their radial scale length being constant from Sb to Sd galaxies (only {approx}10% larger than the stellar scale length). Many S0/a-Sab galaxies have central depressions in their dust radial distributions. The PAH abundance increases with metallicity for 12 + log(O/H) < 9, and at larger metallicities the trend flattens and even reverses, with the SFH being a plausible underlying driver for this behavior. The dust-to-gas ratio is also well correlated with metallicity and therefore decreases with galactocentric radius. Although most of the total emitted IR power (especially in the outer regions of disks) is contributed by dust grains heated by diffuse starlight with a similar intensity as the local Milky Way radiation field, a small amount of the dust mass ({approx}1%) is required to be exposed to very intense starlight in order to reproduce the observed fluxes at 24 {mu}m, accounting for {approx}10% of the total integrated IR power.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of ethylene gas in exhaled breath of people living in landfill using CO{sub 2} laser photoacoustic spectroscopy with multicomponent analysis

The photoacoustic spectrometer (PAS) had been built and the performance had been determined. The research was based on the conversion of the absorbed middle infra red (IR) radiation by gas confined in a closed PAS cell into standing acoustic wave, which could be detected by a suitable electroacoustic transducer such as a microphone. The lowest detection limit for this setup was (57,1 ± 0,3) ppb and quality factor was (14,5 ± 0,6) for ethylene gas in 10P14 CO{sub 2} laser line. Then, this PAS was used to measure of ethylene gas concentration in breath sample of people living in near the Piyungan Bantul Yogyakarta landfill. The result from multicomponent analysis showed that PAS enable to measure the lowest concentration of volatile organic compound (VOC), such as ethylene, which occured on ambien air in Piyungan landfill. Variaty of distance area applied in this research. In the range of ±0,5 km from landfill, we obtained the concentration of ethylene gas concentration for human breath was (1,520 ± 0,002) ppm, while in the range of ±45 km, the ethylene gas concentration for human breath was (0,424 ± 0,002) ppm. Ethylene gas concentrations in exhaled gas decreased along with increasing distance variation of the landfill.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental study of ethylene counterflow diffusion flames perturbed by trace amounts of jet fuel and jet fuel surrogates under incipiently sooting conditions

The structure of an ethylene counterflow diffusion flame doped with 2000 ppm on a molar basis of either jet fuel or two jet fuel surrogates is studied under incipient sooting conditions. The doped flames have identical stoichiometric mixture fractions (z{sub f} = 0.18) and strain rates (a = 92 s{sup -1}), resulting in a well-defined and fixed temperature/time history for all of the flames. Gas samples are extracted from the flame with quartz microprobes for subsequent GC/MS analysis. Profiles of critical fuel decomposition products and soot precursors, such as benzene and toluene, are compared. The data for C7-C12 alkanes are consistent with typical decomposition of large alkanes with both surrogates showing good qualitative agreement with jet fuel in their pyrolysis trends. Olefins are formed as the fuel alkanes decompose, with agreement between the surrogates and jet fuel that improves for small alkenes, probably because of an increase in kinetic pathways which makes the specifics of the alkane structure less important. Good agreement between jet fuel and the surrogates is found with respect to critical soot precursors such as benzene and toluene. Although the six-component Utah/Yale surrogate performs better than the Aachen surrogate, the latter performs adequately and retains the advantage of simplicity, since it consists of only two components. The acetylene profiles present a unique multimodal behavior that can be attributed to acetylene's participation in early stages of formation of soot precursors, such as benzene and other large pyrolysis products, as well as in the surface growth of soot particles. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanosecond Nd-YAG laser induced plasma emission characteristics in low pressure CO{sub 2} ambient gas for spectrochemical application on Mars

An experimental study is conducted on the possibility and viability of performing spectrochemical analysis of carbon and other elements in trace amount in Mars, in particular, the clean detection of C, which is indispensible for tracking the sign of life in Mars. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from a pure copper target in CO{sub 2} ambient gas of reduced pressure simulating the atmospheric condition of Mars. It is shown that the same shock wave excitation mechanism also works this case while exhibiting remarkably long cooling stage. The highest Cu emission intensities induced by 4 mJ laser ablation energy is attained in 600 Pa CO{sub 2} ambient gas. Meanwhile the considerably weaker carbon emission from the CO{sub 2} gas appears relatively featureless over the entire range of pressure variation, posing a serious problem for sensitive trace analysis of C contained in a solid sample. Our time resolved intensity measurement nevertheless reveals earlier appearance of C emission from the CO{sub 2} gas with a limited duration from 50 ns to 400 ns after the laser irradiation, well before the initial appearance of the long lasting C emission from the solid target at about 1 μs, due to the different C-releasing processes from their different host materials. The unwanted C emission from the ambient gas can thus be eliminated from the detected spectrum by a proper time gated detection window. The excellent spectra of carbon, aluminum, calcium, sodium, hydrogen, and oxygen obtained from an agate sample are presented to further demonstrate and verify merit of this special time gated LIBS using CO{sub 2} ambient gas and suggesting its viability for broad ranging in-situ applications in Mars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AmeriFlux US-Bsg Burns Sagebrush

This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Still, Chris↗

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site R. Bhave (Oak Ridge National Laboratory. Oak Ridge, TN) and M. R. Poirier* (Savannah River National Laboratory, Aiken SC) Solid-liquid separation is the limiting step for many waste treatment processes at the Savannah River Site. SRNL researchers have identified the rotary microfilter as a technology to improve the rate of solid-liquid separation processes. SRNL is currently developing the rotary microfilter for radioactive service and plans to deploy the technology as part of the small column ion exchange process. The rotary microfilter can utilize any filter media that is available as a flat sheet. The current baseline membrane is a 0.5 micron (nominal) porous metal filter (Pall PMM050). Previous testing with tubular filters showed that filters composed of a ceramic membrane on top of a stainless steel support produce higher flux than filters composed only of porous metal. The authors are working to develop flat sheet filter media composed of a ceramic membrane and/or ceramic-metal composite on top of a porous stainless steel support that can be used with the rotary microfilter to substantially increase filter flux resulting in a more compact, energy efficient and cost-effective high level radioactive waste treatment system. Composite membranes with precisely controlled pore size distribution were fabricated on porous metal supports. High quality uniform porous metal (316SS) supports were fabricated to achieve high water permeability. Separative layers of several different materials such as ultrafine metal particles and ceramic oxides were used to fabricate composite membranes. The fabrication process involved several high temperature heat treatments followed by characterization of gas and liquid permeability measurements and membrane integrity analysis. The fabricated composite membrane samples were evaluated in a static test cell manufactured by SpinTek. The composite membranes were evaluated on several feed slurries: 1 wt. % strontium carbonate in deionized water, 1 wt. % monosodium titanate in simulated salt solution, and 1 wt. % simulated sludge in simulated salt solution and deionized water. Flux as a function of feed flow rate and transmembrane pressure was measured for each of the above described feed slurries. The authors will discuss the new membrane development efforts, waste slurry filtration performance evaluations and scale-up considerations.

Bhave, Ramesh R↗

Characterization of a Si-SiO{sub 2} Mixture Generated from SiO(g) and CO(g)

The reaction between SiO(g) and CO(g) is a relevant intermediate reaction in the silicon production process. One of the products generated from this gas mixture is called by its color, brown condensate. In this paper, SiO(g) and CO(g) are produced from SiO{sub 2}-SiC pellets. The reaction between the two gases occurred on SiC particles. Inert gas was injected at different flows. The SiC particles were collected, and the brown condensate deposited on them was characterized by electron probe microanalysis, X-ray photoelectron spectroscopy, and focused ion beam preparation samples for transmission electron microscope analysis. The brown condensate consists of a mixture of Si spheres embedded in a SiO{sub 2} matrix. The compound generates in the temperature range from 1400 °C to 1780 °C (1673 K to 2053 K), and in the SiO(g) partial pressure range between 0.534 and 0.742, depending on the inert gas flow. SiC crystallites are located at the Si-SiO{sub 2} interface. Carbides are believed to generate from the reaction between liquid silicon and CO(g). Carbides may also precipitate from reaction between dissolved carbon and liquid silicon, but to a minor extent. Both mechanisms are believed to happen above the melting point of silicon and in the softening range of silica.

36 MATERIALS SCIENCE↗

Transversely Excited Atmospheric CO{sub 2} Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO{sub 2} laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO{sub 2} laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

54 ENVIRONMENTAL SCIENCES↗

CO 2 Capture by Cold Membrane Operation with Actual Power Plant Flue Gas

The main objective of the project was to develop a post-combustion CO 2 capture process based on the hybrid cold temperature membrane operation. The CO 2 in the flue gas from coal fired power plant is pre-concentrated to >60% CO 2 in the first stage membrane operation followed by further liquefaction of permeate stream to achieve >99% CO 2 purity. The aim of the project was based on DOE program goal of 90% CO 2 capture with >95% CO 2 purity from Pulverized Coal (PC) fired power plants with $40/tonne of carbon capture cost by 2025. The project moves the technology from TRL 4 to TRL 5. The project involved optimization of Air Liquide commercial 12” PI-1 bundle to improve the bundle productivity by >30% compared to the previous baseline (DE-FE0004278) using computational fluid dynamics (CFD) modeling and bundle testing with synthetic flue gas at 0.1 MWe bench scale skid located at Delaware Research and Technology Center (DRTC). In parallel, the next generation polyimide based novel PI-2 membrane was developed with 10 times CO 2 permeance compared to the commercial PI-1 membrane. The novel PI-2 membrane was scaled from mini-permeator to 1” permeator and 1” bundle for testing. Bundle development was conducted with a Development Spin Unit (DSU) installed at MEDAL. Air Liquide’s cold membrane technology was demonstrated with real coal fired flue gas at the National Carbon Capture Center (NCCC) with a 0.3 MWe field-test unit (FTU). The FTU was designed to incorporate testing of two PI-1 commercial membrane bundles (12” or 6” diameter) in parallel or series. A slip stream was sent to the next generation PI-2 membrane for testing with real flue gas. The system exceeded performance targets with stable PI-1 membrane operation for over 500 hours of single bundle, steady state testing. The 12” PI-1 bundle exceeded the productivity target by achieving ~600 Nm3/hr, where the target was set at ~455 Nm3/hr at 90% capture rate. The cost of 90% CO 2 capture from a 550 MWe net coal power plant was estimated between 40 and $45/tonne. A 6” PI-1 bundle exhibited superior bundle performance compared to the 12” PI-1 bundle. However, the carbon capture cost was not lower with the 6” PI-1 bundle due to the higher bundle installed cost. A 1” PI-1 bundle was tested to compare bundles with different length / diameter ratios. This bundle exhibited the lowest performance due to the different fiber winding pattern and increased bundle non-ideality. Several long-term and parametric tests were conducted with 3,200 hours of total run-time at NCCC. Finally, the new PI-2 membrane fiber was tested at a small scale (1” modules) in real flue gas and exhibited up to 10 times the CO 2 permeance and slightly lower CO 2 /N 2 selectivity as the commercial PI-1 fiber. This corresponded to a projected 4 - 5 times increase in the productivity per bundle and a potential cost reduction of $3/tonne for CO2 capture, as compared with PI-1. An analytical campaign was conducted to trace different impurities such as NOx, mercury, Arsenic, Selenium in gas and liquid samples through the carbon capture system. An Environmental, Health and Safety (EH&S) analysis was completed to estimate emissions from a 550 MWe net power plant with carbon capture using cold membrane. A preliminary design and cost analysis was completed for 550 tpd (~25 MWe) plant to assess the capital investment and carbon capture cost for PI-1 and PI-2 membrane solutions from coal fired flue gas. A comparison was made with an amine based solution with significant cost advantage for the membrane at this scale. Additional preliminary design and cost analysis was completed between coal, natural gas and SMR flue gas for carbon capture at 550 tpd (~25 MWe) plant.

01 COAL, LIGNITE, AND PEAT↗