Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Communications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Distributed optimization and control for autonomous distributed energy resource power dispatch and frequency regulation considering communication failures

Distributed energy resources (DERs) can significantly enhance grid flexibility by supplying power and secondary frequency regulation (SFR) services. Yet, their large number and dispersed nature limit the effectiveness of traditional centralized power dispatch and frequency control schemes, and expose the system to single-point communication failures. This paper presents a unified distributed optimization and control framework for DER power dispatch and SFR provision. A transmission-loss-aware distributed direct current optimal power flow is first formulated to optimize DER power dispatch and reserve scheduling. On top of this, a fully distributed control scheme for DER autonomous SFR provision is developed to allocate automatic generation control signals cost-effectively while ensuring robustness to communication link disruptions. The framework is validated on IEEE 14-bus and 39-bus transmission systems with large-scale distribution feeders using transmission-distribution dynamic co-simulation, demonstrating reliable and autonomous DER power dispatch and SFR provision under diverse operating conditions and communication contingencies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Configurable DERMS Test System in GridAPPS-D

Distributed Energy Resources and their increased penetration within the power grid are a suitable method to provide essential reliability services. In order to do so, they must operate in aggregate. Aggregation of a wide variety of systems with varying standards and protocols is a complex task, which could benefit from rules and standards to support interoperability. To this end, the Portland State University Power Lab has developed the Energy Grid of Things project, which includes a Distributed Energy Resource Management System to provide aggregation and demonstrate the usage of an Energy Services Interface: a set of rules governing the interface between resource owners and aggregator businesses. This thesis presents a Modeling Environment that provides a simulation and test platform reflecting the complex needs of an aggregator. A grid simulator is required that is able to reflect the effects of thousands of Distributed Energy Resources operating in tandem; furthermore, these effects must be communicated to external actors such as the Grid Operator, which provides grid service requests to the aggregator and requires feedback. The Modeling Environment provides all of this functionality by leveraging the GridAPPS-D platform to develop an interoperable class-based system that provides configurable simulations with modular input and output APIs. The Modeling Environment uses abstractions to allow any feasible type of input to be reflected within the model as a Distributed Energy Resource, and serves as a proof-of-concept for the development of aggregation simulation and testing within GridAPPS-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demand Bidding Model for Multi-Product Industrial Plants

The growing contribution of renewable energy sources has increased volatility and uncertainty in electricity markets, challenging traditional grid operation paradigms. Demand bidding (DB), a market participation model where (large) electricity users communicate their willingness to pay for electricity to the grid operator, was shown in previous work to enhance grid stability and lower generation cost. We present a DB model for multi-product industrial plants, based on an extended optimal power flow problem where the plant dynamics are represented using autoregressive with extra inputs (ARX) models. We compare DB to price-based demand-side management, showing that, under certain assumptions, the two approaches are equivalent, while DB provides more transparency and predictability to the grid operator. A case study based on an industrial air separation unit is discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inventory of Public Key Cryptography in US Electric Vehicle Charging

Electric vehicles (EVs) and charging infrastructure are networked systems, which employ high-level communications in support of charging and grid service decisions. Public key cryptography (PKC) underlies much of the security and privacy protections of the information exchange. We are entering a new epoch where quantum computing threats must be seriously considered. A sufficiently large quantum computer, so named Cryptographically Relevant Quantum Computer (QRQC), will be able to perform the mathematical operations to efficiently attack the underpinnings of traditional PKC, thus jeopardizing the digital foundations for trust, communications security, and data security. Estimates suggest a QRQC can break public key encryption and digital signatures in the manner of tens to hundreds of hours, compared to traditional computing that would demand more than 10 18 years in a brute force-style attack. A consensus belief of quantum theorists, quantum experimenters, and cryptographers suggest that the quantum threat will be likely realized in the next twenty years. To address the threat, post-quantum cryptography, which is cryptosystems that are designed to be secure against both traditional and quantum computing threats, must be adopted. Migration from traditional PKC to quantum-resilient cryptography is a global undertaking and likely represents the largest transition in computing history. The nascent state of EV public key infrastructure, combined with limited adoption of the vehicle secure charging features, presents an opportunity to establish a preference for quantum-resistant cryptography as a step on the migration path. Delays will stunt the efforts as rapidly accelerating EVs sales and huge infrastructure investments will create large growing bases of long-lived vehicles and infrastructure. Migration preparations can commence while NIST continues the process to standardize post-quantum cryptography (PQC), which are quantum-resilient algorithms designed to be secure against traditional and quantum computing threats. The first step in preparing EV charging is to identify the presence of traditional public key cryptography algorithms and applications. With this objective in mind, this report is intended to advise the vehicle manufacturers, charging station manufacturers, charging station operators, charge network providers and other EV charging stakeholders with information on traditional PKC application and the potential risks when PKC becomes insecure. This report, the first in a series of reports discussing the topics existing at the confluence of post-quantum cryptography adoption and EV charging, identifies traditional public key applications employed and identifies potential consequences of leaving EV charging infrastructure vulnerable to quantum computing. The focus remains squarely on the of EV charging and infrastructure with respect to PKC and is believed by the authors to complement the NIST SP 1800-38 Migration to Post-Quantum Cryptography. While the report is centered on infrastructure, there are implications to vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Demand-Side Opportunity: The Roles of Distributed Solar and Building Energy Systems in a Decarbonized Grid

Building energy systems represent a significant and largely untapped demand-side grid resource. Buildings use about 75% of electricity in the United States, including around 80% of peak demand, meaning that changes in building energy use have significant implications for grid operations. Building energy technologies-including energy-efficient devices, flexible loads, and energy storage-can be coordinated and aggregated to perform similar functions as centralized grid assets. Recent advances in information and communication (ICT) technologies have significantly improved building energy technology automation, coordination, and aggregation capabilities. With declining costs and technological advances, building energy systems can increasingly compete with conventional grid assets such as natural gas plants. Building energy technologies enable the deployment of distributed solar photovoltaics (DPV). Energy-efficient buildings allow DPV to meet greater shares of building load while flexible loads and energy storage can reshape building load profiles to optimize the on-site use of DPV. Optimized on-site use of DPV increases the value proposition for DPV adoption and can help utilities cost-effectively integrate higher levels of DPV penetration. Together, DPV and building energy technologies could help grids achieve deep decarbonization more quickly and cost-effectively.

14 SOLAR ENERGY↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Distributed model predictive control for coordinated, grid-interactive buildings

Continued focus on reducing carbon emissions and improving energy efficiency requires buildings to become grid-interactive and not just behave as static consumers. A distributed model predictive control (DMPC) algorithm known as Limited-Communication (LC) DMPC is modified to enable grid-interactive buildings. A grid-aggregator subsystem is added that allows for a bulk grid power reference signal to be followed while the individual building subsystems also achieve their local comfort objectives. The LC-DMPC algorithm is applied for the first time to systems with multiple buildings. Adequate power tracking is shown for different simulation scenarios involving heterogeneous buildings, and next steps are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

Impact of DER Communication Delay in AGC: Cyber-Physical Dynamic Co-Simulation: Preprint

Distributed energy resource (DER) frequency regulations are promising technologies for future grid operation. Unlike conventional generators, DERs might require open communication networks to exchange signals with control centers, possibly through DER aggregators; therefore, the impacts of the communication variations including the latency on the system frequency stability need to be investigated. This paper develops a cyber-physical dynamic simulation (CPDS) model based on the Hierarchical Engine for Large-Scale Co-Simulation (HELICS) to evaluate the impact of the communication variations, such as delays in DER frequency regulations. The feasible delay range can be obtained under different AGC parameter settings. The results show that the risk of instability generally increases with the communication delay and that the difference of AGC provided from DER and conventional generation units should be recognized when designing frequency regulation controllers.

61 RADIATION PROTECTION AND DOSIMETRY↗

5G Energy FRAME Report on 5G for Grid Use Case (Year 3 Final Report)

This report provides an extensive overview of the interrelationships among energy, communication, and computing—especially in the context of decarbonization goals, challenges, and opportunities. Technical examples enabled by 5G technologies and their performance are presented, discussed, based on the experiment performed at Pacific Northwest National Laboratory. This is the first use case focused on using 5G for the U.S. power grid and will be referred to as the 5G for Grid Use Case from here on. Specifically, this use case looks at the workflow, which integrates the performance data of a real-world 5G communication testbed and a grid transmission and distribution co-simulation platform. The cross-domain information flow and logic design are illustrated with a combination of power grid contingencies and events. Lastly, a summary of the project achievement and outcome is provided, along with a technology roadmap envisioned by the project team.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

The locational value of distributed energy resources: A parcel-level evaluation of solar and wind potential in New York state

We report distributed energy resources (DERs) are poised to play a significant role in evolving power systems because of their flexibility to be sited in areas of high value to the grid. Traditional DER compensation frameworks, specifically net energy metering (NEM), inadequately communicate differences in the locational and temporal value of DER generation to the grid. As a transition from NEM, New York State's (NYS's) Value of Distributed Energy Resources (VDER) framework provides a methodology for calculating different value components that DERs offer the grid. To study the impacts of VDER frameworks on DER deployment, we developed a model to assess the value of distributed solar and wind systems configured as either a behind-the-meter system or a front-of-the-meter system for each parcel of land in NYS. Using parcel-level granularity, we can closely evaluate DER locational value and siting availability, particularly in urban and suburban settings. Our analysis finds while most DER generators would be modestly compensated for deferred transmission and distribution infrastructure upgrades (~0.01 $\$$/kWh for solar PV), a subset of projects receive significant value from this component (0.035 to 0.089 $\$$/kWh for top 5% of parcels for solar PV). Finally, our analysis finds VDER provides less overall compensation than NEM to the average DER generator, however, it increases access to compensation for front-of-the-meter DERs - a large and emerging market.

14 SOLAR ENERGY↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗