Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Protection Coordination Considerations for a Highly Meshed Urban Microgrid

In microgrid distribution systems, irregular system fault characteristics (with respect to grid-connected mode) and the variability of power flow direction, present challenges to developing a robust and reliable protection scheme that will effective response in both grid-connected and grid-isolation mode. The following investigation captures a meshed network from a larger urban low-voltage (LV) network system in the service area of Consolidated Edison Company of New York (ConEdison), a United States (US) utility that has sufficient customer supplied generation to act as a standalone microgrid. The investigation assesses the viability of differential protection schemes. Protection response has been reviewed with respect to real world application; including, benefits and limitations of selectivity, sensitivity and reliability.

Bello, Mobolaji↗

Machine learning based rate optimization under geologic uncertainty

We propose a novel approach for rate optimization during a waterflood under geologic uncertainty in reservoir properties such as permeability and porosity. The traditional approach typically involves several runs of the forward simulator. This may not scale well when the optimization is to be performed at the full field-level and over multiple geologic realizations. A machine-learning (ML) based approach which is quick and scalable for rate optimization over multiple geologic realizations is proposed instead. The training data for the model is generated by running the forward simulator with randomly assigned well rates using multiple geologic realizations. A reduced order representation of the permeability heterogeneity in each of the realizations is derived using a grid connectivity transformation (GCT). This step involves finding basis functions corresponding to the different modal frequencies of the grid connectivity represented by the grid Laplacian. The projection of the heterogeneous property field along these basis functions gives the basis coefficients that form the reduced order representation. Subsequently, for each training datapoint, streamlines are traced and the minimum time of flight (TOF) representing the tracer breakthrough time at each producer is recorded. The basis coefficients and well rates are fed to a machine learning model as input and the minimum TOF at the producers forms the output of the model. This trained model can then be used along with an optimizer for computing the optimal injection rates to maximize the injection sweep efficiency. This corresponds to minimizing the variance in the minimum TOF within each well group. Different architectures of neural network are tested using 5-fold cross validation to decide the best ML model to compute the streamline time of flight. The trained model is used to perform well rate optimization over multiple realizations of geology by using a risk tolerance penalty. The optimal well rates thus obtained are compared with two cases: a) equal well rates assigned to all injectors and producers and b) well rates obtained by optimizing over a single realization without considering the uncertainty in geology. The optimal well rates are seen to offer better oil recovery and sweep efficiency than both cases.

02 PETROLEUM↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Grid Energy-Storage Projects: Engineers Building and Using Knowledge in Emerging Projects

At this stage of the rapidly evolving role of grid-connected battery energy-storage systems (BESSs), actual experience with grid-connected BES projects is limited as is experience in how to control these complex systems for effective application and economic benefits. Furthermore our coauthors share their unique experiences of working at the forefront of BESs on the grid: an emerging and expanding new tool being applied across all grid domains, e.g., energy production, transmission, distribution, and utilization.

25 ENERGY STORAGE↗

Secondary Use-Plug-and-Play Energy Storage System Composed of Multiple Energy Storage Technologies

Low-cost, grid-connectable energy storage technologies represent a significant challenge for the electric grid of the future. Energy storage technologies are in rapid development with targets to reduce the storage medium cost. However, a significant cost to deployment also comes in the integration. This paper presents the development of a plug-and-play system for supporting secondary use multiple battery systems into a single grid connectable unit. Results of the system design are demonstrated in a controller hardware in the loop (CHIL) platform. Simulations of two energy storage systems operating in parallel and dispatched optimally are presented.

Starke, Michael↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Microgrid Design Toolkit (MDT) User Guide Software v1.2.

The Microgrid Design Toolkit (MDT) supports decision analysis for new ("greenfield") microgrid designs as well as microgrids with existing infrastructure. The current version of MDT includes two main capabilities. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new, grid connected microgrid in the early stages of the design process. MSC is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on designing a microgrid for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM).

97 MATHEMATICS AND COMPUTING↗

Microgrid Design Toolkit (MDT) User Guide. Software v1.3.

The Microgrid Design Toolkit (MDT) supports decision analysis for new ("greenfield") microgrid designs as well as microgrids with existing infrastructure. The current version of MDT includes two main capabilities. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new, grid connected microgrid in the early stages of the design process. MSC is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on designing a microgrid for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM).

42 ENGINEERING↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Solar Market Trends

Grid-connected photovoltaic installations grew by 40% in 2009 compared with installations in 2008. California and New Jersey have the largest markets. Growth occurred in the residential and utility markets, but non-residential customer-sited installations did not change compared with the installations in 2008. Two small solar thermal electric plants were connected to the grid in 2009 with a combined capacity of 7 MW. The future prospects for solar thermal electric plants look bright, although developers are not expected to complete any new large plants until at least 2011. Solar water heating and solar space heating annual installations grew by 40% in 2008 compared with 2007. Hawaii, California, Puerto Rico, and Florida dominate this market. Solar pool heating annual installation capacity fell by 1% in 2008 following a dramatic decline of 15% in solar pool heating capacity in 2007 compared with 2006. Florida and California are the largest markets for solar pool heating. The economic decline in the real estate markets in Florida and California likely led to the decrease in pool installations and thus the dramatic decline in capacity installed of solar pool systems in 2007.

14 SOLAR ENERGY↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

2016 Alabama PV soft cost and workforce development

The Southeastern US has the largest potential for growth in the solar industry. However, currently they languish behind the rest of the US. There are several bright spots including the large number of utility scale installations in North Carolina and the recent successes in South Carolina under Act 236. In order to better understand the impacts of state legislation on the growth of the solar industry in the SE US, the Savannah River National Laboratory has undertaken a study to look at the growth in each state in order to develop recommendations to help reduce the cost of solar and to spur the industry. This is the second report in the series. The first focused on developing cost metrics for South Carolina under Act 236. This report focuses on Alabama, the 49th ranked state for solar business, which has very similar population and median income to South Carolina. For this survey, the ten known in-state installers were contacted. Responses were received from seven, representing 70% of the installers, a majority of which provide both residential and commercial installations. Interestingly, none of the respondents serve the utility scale sector. Overall, costs for Alabama are on track with the rest of the country with a reported average cost of $3.29/W-DC for residential systems and $2.44/W-DC for commercial systems. 60% of this cost is attributed to hardware only. Of the remaining costs, installation contributed to the largest percentage of soft costs followed by overhead, marketing and sales, and permitting, respectively. This also closely mirrors results seen in South Carolina. Job growth in the industry is expected to proceed well. An expected 34-42 additional full time equivalent jobs were expected to be added in Alabama within the six month window following the survey period. During the three years following the survey, this number was expected to double with 89-97 additional jobs being added to the market. In both cases, a vast majority of these jobs were for installation professionals and electricians. Despite the cost of solar, the industry continues to struggle in Alabama, largely due to the absence of any statewide net metering legislation. By current best estimates, there are over 60 residential installations statewide; however, this number is difficult to track due to the lack of a State authority keeping a consolidated list of grid connected distributed power systems. In South Carolina, the Energy Office tracks and reports grid connected distributed power systems by all Cooperatives and utilities. In Alabama, the Energy Office does not fulfill this role and data must be collected directly from each utility and cooperative, which makes collection and analysis difficult. Having a central state agency track this information would be extremely useful towards developing state policy recommendations, particularly if net metering were enabled within the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced-Order Aggregate Model for Parallel-Connected Single-Phase Inverters

This paper outlines a reduced-order aggregate dynamical model for parallel-connected single-phase grid-connected inverters. For each inverter, we place no restrictions on the converter topology and merely assume that the ac-side switch-averaged voltage can be controlled via pulsewidth modulation. The ac output of each inverter interfaces through an LCL filter to the grid. The closed-loop system contains a phase locked loop for grid synchronization, and real- and reactive-power control are realized with inner and outer PI current- and power-control loops. We derive a necessary and sufficient set of parametric relationships to ensure that a reduced-order aggregated state-space model for an arbitrary number of such paralleled inverters has the same model order and structure as any single inverter. We also present reduced-order models for the settings where the real- and reactive-power setpoints are different and where the inverters have different power ratings. We anticipate the proposed model being useful in analyzing the dynamics of large collections of parallel-connected inverters with minimal computational complexity. The aggregate model is validated against measurements obtained from a multi-inverter experimental setup consisting of three 750-VA paralleled grid-connected inverters, hence establishing robustness of the analytical result to parametric variations seen in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Signal Impedance-Based Modeling and Mitigation of Resonance of Converter-Grid Systems

Large-signal impedance of grid-connected converters can be used to predict resonance-generated distortions in converter-grid systems. Note that the large-signal impedance of a network represents its impedance response for different magnitudes of perturbation injected at its terminals. This paper presents large-signal impedance-based modeling and mitigation of resonance of grid-connected voltage source converters (VSCs). Challenges of large-signal modeling because of the inapplicability of the small-signal approximation are addressed by leveraging the dominating influence of hard nonlinearities (such as pulse-width modulation saturation and limiters) over soft nonlinearities (such as Park's transformations and PLL) in shaping the large-signal behavior of the converter. The paper develops large-signal gains of hard nonlinearities using different types of describing functions. The paper shows that the large-signal impedance of a VSC can be shaped to reduce resonance-generated distortions by inserting limiters in the control system of the VSC. Developed large-signal impedance models are validated using numerical simulations of a VSC with dq current control and PLL. In conclusion, a large-signal impedance measurements of a commercial 1 MW VSC-based inverter and a medium-voltage doubly-fed induction generator with approximate 4 MW rating are presented to experimentally demonstrate the influence of the injected perturbation magnitude on the impedance response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗