Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH VACUUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING↗

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Material Selection and Operational Conditions for XHV Systems: Lessons from AISI 1020 and 316L Comparative Studies

In this study, AISI 1020 low-carbon steel is investigated as a cost-effective alternative to SS316 stainless steel for reaching extreme high vacuum (XHV) conditions. After being baked at 400°C, a vacuum chamber made of the low-carbon steel material exhibited an outgassing rate approximately 2000 times smaller than a similar chamber made of stainless steel. Its activation energy for hydrogen diffusion (27 kJ/mol) is less than half that of stainless steel (60.3 kJ/mol), indicating more efficient hydrogen removal during bakeout. MolFlow+ simulations supported the experimental data and demonstrated the importance of system geometry optimization and minimizing stainless steel content for achieving optimal vacuum performance. AISI 1020's magnetic properties, typically considered disadvantageous for accelerator applications, could benefit spin-polarized electron sources by shielding photocathodes from stray fields while simultaneously providing improved vacuum through reduced outgassing. To optimize AISI 1020's performance in XHV systems, practical considerations include pre-baking protocols and careful system design to minimize stainless steel components.

Al-Allaq, Aiman H.↗

Combining Particle Tracking with Electromagnetic Radiation Showers: Merging GPT and Geant4 with Visualization

Field emitted electrons can seriously affect the operation of high-field, high-duty factor electron accelerators. Accelerated field emission can result in high average power beams which can radiation damage beamline components. In addition, localized losses generate thermal hot spots whose outgassing degrades the ultra-high vacuum required in photoinjectors and cryomodules. However, despite their importance, the effects of field emission are rarely included in the design and engineering of electron injectors. This work attempts to remedy this situation by combining two well-known and well-documented programs, GPT and Geant4, to track electrons and their losses in an injector beamline. This paper describes a system of programs which simulates electron paths and losses along the beamline. In addition, the tracking results can be zoomed and panned along and about the beampipe envelope using an open-source 3D CAD program. The scattering albedo calculations of the combined program, GPT-Geant4, are shown to be in good agreement with the literature albedos. The paper concludes with a dark current simulation for the LCLS-II injector from the cathode to the collimator at 1.5 m from the cathode.

Dowell, David H.↗

Universal liquid sample device and process for high resolution transmission electron microscope imaging and multimodal analyses of liquid sample materials

Liquid sample imaging devices and processes are disclosed for high resolution TEM imaging and multimodal analyses of liquid sample materials in situ under high vacuum that are compatible with standard type TEM chip membranes and TEM sample holders allowing TEM liquid sample imaging to be performed wherever a TEM instrument is accessible and at a substantially reduced cost compared to prior art systems and approaches.

36 MATERIALS SCIENCE↗

Monocrystal-based microchannel plate image intensifier

A monocrystalline scintillator comprises a monocrystal and an optical plate wherein a first side of the monocrystal is adhered to the optical plate. The monocrystal comprises at least one of a rare earth garnet, a perovskite crystal, a rare-earth silicate, and a monocrystal oxysulphide. The scintillator assembly includes an adhesive adhering the optical plate to the first side of the monocrystal. The adhesive can comprise an ultra-high vacuum compatible adhesive. The adhesive is substantially transparent and has a refractive index matching the optical plate. The scintillator assembly can also include a reflective coating on the second side of the monocrystal. The monocrystalline scintillator assembly can be incorporated in a microchannel plate image intensifier tube to provide improved spatial resolution and temporal response.

Lumpkin, Alex H.↗

Application Of The ASME Boiler And Pressure Vessel Code In The Design Of SSR Cryomodule Beamlines For PIP-II Project At Fermilab

This contribution reports the design of the main components used to interconnect SRF cavities and superconducting focusing lenses in the SSR Cryomodule beamlines, developed in the framework of the PIP-II project at Fermilab. The focus of the present contribution is on the design and testing of the edge-welded bellows according to ASME Boiler and Pressure Vessel Code. The activities performed to qualify the bellows to be assembled in cleanroom, for operation in high vacuum, cryogenic environments, and their characterization from magnetic standpoint, will also be presented.

43 PARTICLE ACCELERATORS↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

Enhanced Tensile and Tear Toughness Properties of Thin-Wall Vacuum-Assisted High-Pressure Die-Cast Aural-5 Alloy by Friction Stir Processing

Steadily rising demand for glider weight reduction has driven the development of vacuum-assisted high-pressure die-cast (HPDC) Al-alloys for automotive structural components. Aural-5 is a strontium-modified HPDC alloy utilizing manganese (Mn) to reduce die soldering, eliminating detrimental needle-shaped Fe-bearing ß-phase intermetallic and improving ductility. HPDC Aural-5 contains shrinkage porosity, dendrites with Al-Si eutectic colonies, externally solidified crystals (ESCs), shear-band structure, and large second-phase particulates. Porosity, ESCs and large second-phase particles work as crack initiation sites, negatively impacting tensile properties. In this study, friction stir processing (FSP) is employed for microstructural modification of a thin-walled HPDC Aural-5 by eliminating porosity and breaking down dendrites, second-phase particles, eutectic colonies, ESCs and shear-band structures to create wrought microstructure with homogenized particle distribution. Mechanical property characterization indicates ~30% and ~35% enhancement in yield strength and ductility and associated marked effects on ~69% improvement in tear toughness according to the ASTM B871 test.

Friction stir processing, Aural-5, Strength, Tear ↗

Friction stir processing on a strontium modified, thin-wall, vacuum-assisted high-pressure die-cast Aural-5 alloy to improve tensile and fatigue performance

Here, this study explores the application of friction stir processing (FSP) to enhance the material properties of Sr-modified Aural-5 alloy, with a focus on improved tensile and fatigue properties. Aural-5 is a well-known vacuum-assisted high-pressure die-cast (HPDC) Al-Si7-Mg alloy used in the automotive industry to reduce vehicle weight, enhance fuel efficiency, and lower carbon emissions. This alloy modifies its material chemistry with Sr for fine fibrous networks of eutectic silicon and manganese (Mn) to reduce die soldering. It has significantly less iron (Fe) content resulting in the elimination of detrimental needle-shaped Fe-bearing ß-phase intermetallic and improving ductility. The initial microstructure of as-received HPDC Aural-5 exhibits shrinkage porosity in the middle section, a dendritic microstructure with fibrous Al-Si eutectic colonies, a shear-band structure beneath the die-wall, large dendritic externally solidified crystals (ESCs), needle-shaped Mg 2 Si phase and significant second-phase particulates. Some of those microstructural features, such as porosity, ESCs, needle-shaped Mg 2 Si phase, and large second-phase particles, serve as initiation sites for cracks under mechanical loading, resulting in adverse effects on tensile properties, particularly ductility. FSP effectively transforms the microstructure into a wrought configuration with uniform particle distribution by eliminating porosity and disintegrating dendrites, eutectic colonies, ESCs, second-phase particles, and shear-band structures. FSP-driven microstructure modification enhances yield strength and tensile ductility by ~30% and ~35%, respectively. The fatigue life of the material in a bending mode configuration (stress ratio R = 0.1) after FSP exhibits enhancements ranging from 2.0 to 3.9 times that of the original HPDC Aural-5 alloy, depending on the applied stress level.

36 MATERIALS SCIENCE↗

Method and device for a high temperature vacuum-safe solder resist utilizing laser ablation of solderable surfaces for an electronic module assembly

A process for manufacturing an electronic component having attaches includes providing a first component having a first attach, forming trenches on a portion of the first attach with a laser to form a solder stop, and providing a second component comprising a second attach. The process further includes providing solder between the first attach and the second attach to form a connection between the first component and the second component, where the trenches contain the solder to a usable area. A device produced by the process is disclosed as well.

Stabach, Jennifer↗

Multistage Surface-Heated Vacuum Membrane Distillation Process Enables High Water Recovery and Excellent Heat Utilization: A Modeling Study

Surface-heated membrane distillation (MD) enhances the energy efficiency of desalination by mitigating temperature polarization (TP). However, systematic investigations of larger scale, multistage, surface-heated MD system with high water recovery and heat recycling are limited. Here, we explore the design and performance of a multistage surface-heated vacuum MD (SHVMD) with heat recovery through a comprehensive finite difference model. In this process, the latent heat of condensation is recovered through an internal heat exchanger (HX) using the retentate from one stage as the condensing fluid for the next stage and an external HX using the feed as the condensing fluid. Model results show that surface heating enhances the performance compared to conventional vacuum MD (VMD). Specifically, in a six-stage SHVMD process, 54.44% water recovery and a gained output ratio (GOR) of 3.28 are achieved with a surface heat density of 2000 W m –2 , whereas a similar six-stage VMD process only reaches 18.19% water recovery and a GOR of 2.15. Mass and energy balances suggest that by mitigating TP, surface heating increases the latent heat trapped in vapor. The internal and external HXs capture and reuse the additional heat, which enhances the GOR values. We show for SHVMD that the hybrid internal/external heat recovery design can have GOR value 1.44 times higher than that of systems with only internal or external heat recovery. Furthermore, by only increasing six stages to eight stages, a GOR value as high as 4.35 is achieved. The results further show that surface heating can reduce the energy consumption of MD for brine concentration. As a result, the multistage SHVMD technology exhibits a promising potential for the management of brine from industrial plants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, Manufacturing, and Installation of DIII-D Lower Hybrid Current Drive Outer Wall Waveguides and Expandable Vacuum Interface

High field side lower hybrid current drive (HFS LHCD) is promising method for efficient, off axis current drive. To operate this system, development of an expandable combination radio frequency (RF) and vacuum interface was necessary to allow the long (~2 m) waveguides to thermally expand with respect to the DIII-D 0 degree R-1 port extension without damage to the waveguide or excessive force on the vacuum seals which was previously observed when baking the waveguides during operations that were installed in 2024. Design of a custom bellows assembly with RF feedthrough that allows >20mm of waveguide thermal expansion is presented. Fabrication of this bellows assembly required simultaneously vacuum brazing multiple 304 stainless steel flanges to an oxygen free high conductivity copper waveguide section which required significant manufacturing development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗