Testing of the J-2X Augmented Spark Igniter (ASI) and Its Electronics

Reliable operation of the spark ignition system electronics in the J‐2X Augmented Spark Igniter (ASI) is imperative in assuring ASI ignition and subsequent Main Combustion Chamber (MCC) ignition events are reliable in the J‐2X Engine. Similar to the man‐rated J‐2 and RS‐25 engines, the J‐2X ignition system electronics are equipped with spark monitor outputs intended to indicate that the spark igniters are properly energized and sparking. To better understand anomalous spark monitor data collected on the J‐2X development engines at NASA Stennis Space Center (SSC), a comprehensive subsystem study of the engine's low‐ and high‐tension spark ignition system electronics was conducted at NASA Marshall Space Flight Center (MSFC). Spark monitor output data were compared to more detailed spark diagnostics to determine if the spark monitor was an accurate indication of actual sparking events. In addition, ignition system electronics data were closely scrutinized for any indication of an electrical discharge in some location other than the firing tip of the spark igniter ‐ a problem not uncommon in the development of high voltage ignition systems.

Osborne, Robin↗

System reliability analysis through corona testing

In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

Lalli, V. R.↗

ISS And Space Environment Interactions Without Operating Plasma Contactor

The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization thickness is very thin to provide the required solar absorptance and emittance. For conditions where ISS structure can charge negative a large percentage of the array voltage, the dielectric strength of this layer is low, and dielectric breakdown (arcing) can occur. The energy stored capacitively in the structure can be delivered to the arc. The mechanisms by which this energy is delivered and how much of the energy is available hasn't been fully quantified. Questions have been raised regarding the possibility of whether a sustained arc might result due to current collected by the solar arrays from local plasma. It was postulated that even if dielectric breakdown didn't occur, impacts due to micrometeoroids and space debris could penetrate thin layers of dielectric on ISS and initiate an arc due to the coupling provided by the dense local plasma produced by the impact. This was proven in experiments conducted jointly by MSFC and Auburn University. A target chamber with a simulated ionospheric plasma and a biased, anodized aluminum plate and a 1-microfarad capacitor was used. The plate was then impacted by 75-micron particles accelerated to orbital velocity. Arc discharges were sustained for higher voltages but a threshold appears below which no discharge was initiated. Most items without an exposed power system will float electrically near the local plasma potential. This is true of the Space Shuttle, an Astronaut on EVA, and similar items. The structure of ISS might be at a large negative voltage. Therefore, capacitively stored energy can be transferred during docking, installing external boxes and equipment and Astronaut contact with ISS structure. The circumstances of when this can happen and the resulting effects are evaluated in this study. Also, a crewmember on EVA might be in the vicinity of an arc. All safety aspects of such an encounter including charging, molten particles from the arc site and EMI have been evaluated. This paper will report on the total results of this study focussed on the 4A configuration, scheduled to be complete in November, 2000. Interactions such as arcing, debris induced arcs, sustained arcs, sputtering, contamination from sputtering and arcing, docking interactions and Astronaut safety issues will all be addressed.

Carruth, M. R., Jr.↗

Identification of high performance and component technology for space electrical power systems for use beyond the year 2000

Addressed are some of the space electrical power system technologies that should be developed for the U.S. space program to remain competitive in the 21st century. A brief historical overview of some U.S. manned/unmanned spacecraft power systems is discussed to establish the fact that electrical systems are and will continue to become more sophisticated as the power levels appoach those on the ground. Adaptive/Expert power systems that can function in an extraterrestrial environment will be required to take an appropriate action during electrical faults so that the impact is minimal. Manhours can be reduced significantly by relinquishing tedious routine system component maintenance to the adaptive/expert system. By cataloging component signatures over time this system can set a flag for a premature component failure and thus possibly avoid a major fault. High frequency operation is important if the electrical power system mass is to be cut significantly. High power semiconductor or vacuum switching components will be required to meet future power demands. System mass tradeoffs have been investigated in terms of operating at high temperature, efficiency, voltage regulation, and system reliability. High temperature semiconductors will be required. Silicon carbide materials will operate at a temperature around 1000 K and the diamond material up to 1300 K. The driver for elevated temperature operation is that radiator mass is reduced significantly because of inverse temperature to the fourth power.

Maisel, James E.↗

High reliability megawatt transformer/rectifier

The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

Zwass, Samuel↗

Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid-electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid-electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of AC and DC for power transmission. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power generation, transmission, and distribution systems, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of dual-fed induction machines, which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the project along with the system architecture, development status and preliminary results.

Propulsion↗

Investigation into the High Voltage Shutdown of the Oxygen Generator System in the International Space Station

The Oxygen Generation System (OGS) Hydrogen Dome Assembly Orbital Replacement Unit (ORU) serial number 00001 suffered a cell stack high-voltage shutdown on July 5, 2010. The Hydrogen Dome Assembly ORU was removed and replaced with the on-board spare ORU serial number 00002 to maintain OGS operation. The Hydrogen Dome Assembly ORU was returned from ISS on STS-133/ULF-5 in March 2011 with test, teardown and evaluation (TT&E) and failure analysis to follow.

Carpenter, Joyce E.↗

System reliability analysis through corona testing

A corona vacuum test facility for nondestructive testing of power system components was built in the Reliability and Quality Engineering Test Laboratories at the NASA Lewis Research Center. The facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. The facility is being used to test various high-voltage power system components.

Lalli, V. R.↗

The state-of-the-art of dc power distribution systems/components for space applications

This report is a survey of the state of the art of high voltage dc systems and components. This information can be used for consideration of an alternative secondary distribution (120 Vdc) system for the Space Station. All HVdc components have been prototyped or developed for terrestrial, aircraft, and spacecraft applications, and are applicable for general space application with appropriate modification and qualification. HVdc systems offer a safe, reliable, low mass, high efficiency and low EMI alternative for Space Station secondary distribution.

Krauthamer, S.↗

Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations, and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ISS and Space Environment Interactions in Event of Plasma Contactor Failure

The International Space Station (ISS), illustrated in Figure 1, will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, and similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur.

Carruth, M. R., Jr.↗

Critical Insights into Solvent Choice for High-Voltage Organosulfur Electrolytes

Organosulfur electrolytes are promising candidates for enabling high-voltage cathodes due to their superior oxidative stability compared to conventional carbonate-based systems. However, their viscous nature and inability to passivate the anode necessitate the use of passivating agents and diluents to achieve meaningful charge/discharge rates. In this study, we investigate the use of cyclic fluorinated carbonates (CFCs) to form passivating interphases on electrode surfaces, aiming to optimize electrolyte performance in high-voltage systems. Electrolyte formulations containing 1.2 M LiPF 6 in a CFC:sulfone:1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropylether (TTE) mixture (2/5/3 V/V/V) were assessed in full-cell configurations with a LiNi 0.8 Mn 0.1 Co 0.1 O 2 (FCG-NMC) cathode and a 4.5 V upper cutoff potential. The results reveal that 3-3-3-trifluoropropylene carbonate (TFPC) combined with ethyl methyl sulfone (EMS) optimizes electrolyte performance, resulting in lower resistance buildup and reduced capacity loss compared to commercial electrolytes. We also explore the failure mechanisms of several carbonate/sulfone mixtures and identify key considerations for electrolyte compatibility in high-voltage systems. TFPC enhances cycling stability and lowers overall cell resistance, while fluoroethylene carbonate (FEC) formulations, despite higher ionic conductivity, fail to form adequate passivation layers, leading to rapid capacity loss. Additionally, EMS provides superior physical properties that avoid common failure modes seen with other sulfone solvents like methyl isopropyl sulfone and tetramethylene sulfone. Furthermore, this study underscores the importance of carefully selecting passivating carbonates and sulfone solvents to improve electrolyte performance and expand the viability of high-voltage electrolyte systems.

LiNi0.8Mn0.1Co0.1O2 cathode↗

Overview of the High Performance Antiproton (HiPAT) Experiment

The annihilation of matter with antimatter represents the highest energy density of any known reaction, producing 10(exp 8) MJ/g, approximately 10 orders of magnitude more energy per unit mass than chemical based combustion. To take the first step towards using this energy for propulsion applications the NASA MSFC Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. Storage was identified as a key enabling technology since it builds the experience base necessary to understand the handling of antiprotons for virtually all utilization and high-density storage concepts. To address this need, a device referred to as the High Performance Antiproton Trap (HiPAT) is under development at the NASA MSFC PRC. The HiPAT is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system (operation up to 20 KV), and an ultra high vacuum test section (operating in the 10(exp -12) torr range). The system was designed to be portable with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle. These normal ions provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. The ions are produced external to HiPAT using two hydrogen ion sources, with adjustable beam energy and current. Ion are transported in a beam line and controlled through the use of electrostatic optics. These optics serve to both focus and gate the incoming ions, providing microsecond-timed pulses that are dynamically captured by cycling the HiPAT electric containment field like a 'trap door'. The layout of this system more closely simulates the operations expected at an actual antiproton production facility where 'packets' of antiprotons with pulse widths measured in 100's of nanoseconds could be provided. Initial dynamic capture experiments have been performed with both trap and ton source system functioning at approximately 10% of maximum levels, minimizing the potential for extraneous effects. Dynamic trapping techniques demonstrated the successful capture of millions of hydrogen ions with good agreement with the predicted loading based on the timing sequence, trap electric field, and ion beam current. These techniques will be expanded to examine multiple shot capture or 'stacking' to increase the total number of ions stored within HiPAT.

Martin, James J.↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Solar Array Module Plasma Interactions Experiment (SAMPIE) - A Shuttle-based plasma interactions experiment

The Solar Array Module Plasma Interactions Experiment (SAMPIE), an approved Shuttle space flight experiment with a tentative launch date in July 1993, is intended to investigate plasma interactions of high-voltage space power systems. Solar cell modules, representing several technologies, will be biased to high voltages to characterize both arcing (negative potential) and current collection (positive potential). Other solar modules, specially modified in accordance with current theories of arcing and breakdown, will demonstrate the possibility of arc suppression. Finally, several additional test specimens will be included to study the basic nature of these interactions. The authors describe the rationale for the space flight experiment, the measurements to be made, the significance of the expected results, and the current design status of the flight hardware.

Wald, Lawrence W.↗

Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm (1 × 10 -6 ) level and well known on various time scales (μs up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

47 OTHER INSTRUMENTATION↗

A Multistage Stochastic Transmission Expansion Algorithm for Wide-Area Planning under Uncertainty

The overall objective for this project was to develop and demonstrate a set of methods for solving the transmission investment problem for a large network considering many possible scenarios of future conditions and multiple decision points when investments can be made. Project sub-objectives achieved this goal through a succession of extending the methods to apply to problems with increasing complexity or additional features, including the number of decision points, whether generation and transmission are co-optimized, and whether AC or DC power flow is used. A transmission model was developed for the Western Electric Coordinating Council (WECC) region, the high-voltage transmission system that serves the western third of the continental U.S. Using a dataset provided by WECC and by researchers from John Hopkins University, we have validated and demonstrated the model and used it to compare the new method for solving multi-stage stochastic transmission planning to several state-of-the-art techniques. The project has resulted in several key outcomes and achievements: The covariance-based method for choosing a small set of hours to represent short-term variability has superior performance in terms of accuracy to existing methods, including K-means clustering and Importance Sampling; The combined partitioning method for long-term uncertainty with the nested clustering approach for choosing representative hours for each long-term group has superior accuracy for equivalent computational effort compared with existing methods; Using the partitioning/clustering method combined with Sample Average Approximation provides both statistical bounds on the quality of the solution and at the same time, a complete investment plan for all contingencies in the full uncertainty set; no existing methods can provide both at the same time; The method is demonstrated to work well for choosing both transmission and generation investments; A variant on the method allows for both scenario selection and simultaneous correction for the error from the DC power flow approximation to provide a tractable method for AC power flow-based transmission planning under uncertainty; The method applied to the WECC case study demonstrates the additional value to the system operator and the consumer of identifying flexible investment options in the near-term decisions. In particular, the case study exhibits significant option value in postponing some transmission additions that appear useful but in some long-term system states create new congestion problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗