Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Input”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An efficient numerical model for predicting residual stress and strain in parts manufactured by laser powder bed fusion

Abstract Computational modeling of additively manufactured structures plays an increasingly important role in product design and optimization. For laser powder bed fusion processes, the accurate modeling of stress and distortion requires large amount of computational cost due to very localized heat input and evolving complex geometries. The current study takes advantage of a graphics processing unit accelerated explicit finite element analysis code and approximated heat conduction analysis to predict the macroscopic thermo-mechanical behavior in laser selective melting. Adjacent layers and tracks were lumped to reduce the number of time steps and elements in the finite element model. The effects of track and layer grouping on prediction accuracy and solution efficiency are investigated to provide a guidance for a cost-effective simulation. Thin-wall builds from Inconel alloy 625 (IN625) powders were simulated by applying the developed modeling approach to get the detailed residual stress and distortion at a computational speed 50 times higher than conventional approach. Under repeated heating and cooling cycles, a high tensile stress was produced near surfaces of a build due to a larger shrinkage on surface than that in central area. It is also shown that horizontal stresses concentrate near the root and top layers of the IN625 build. The predicted residual elastic strain distribution was validated by the experimental measurement using x-ray synchrotron diffraction.

36 MATERIALS SCIENCE↗

Site dependent factors affecting the economic feasibility of solar powered absorption cooling

A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.

Bartlett, J. C.↗

Stirling engine external heat system design with heat pipe heater

This final report presents the conceptual design of a liquid fueled external heating system (EHS) and the preliminary design of a heat pipe heater for the STM-4120 Stirling cycle engine, to meet the Air Force mobile electric power (MEP) requirement for units in the range of 20 to 60 kW. The EHS design had the following constraints: (1) Packaging requirements limited the overall system dimensions to about 330 mm x 250 mm x 100 mm; (2) Heat flux to the sodium heat pipe evaporator was limited to an average of 100 kW/m and a maximum of 550 kW/m based on previous experience; and (3) The heat pipe operating temperature was specified to be 800 C based on heat input requirements of the STM4-120. An analysis code was developed to optimize the EHS performance parameters and an analytical development of the sodium heat pipe heater was performed; both are presented and discussed. In addition, construction techniques were evaluated and scale model heat pipe testing performed.

Godett, Ted M.↗

Simulation of plasma and neutral transport in PISCES-RF using SOLPS-ITER

In this research, the fluid plasma transport code SOLPS-ITER is applied and validated against experimental data from the plasma interaction surface component experimental station (PISCES)-RF linear plasma device to establish a physics basis for plasma and neutral transport in its two magnetic field (B-field) geometry setups-(1)the cusp and (2) non-cusp or linear B-field. The main focus of this study is to understand (1) radial plasma transport (2) heat and particle loads on the upstream dump and downstream target plate, and (3) the physics of plasma-neutral interactions in PISCES-RF. The simulation setup adheres to typical PISCES-RF experimental conditions, with a 2D helicon power deposition profile as an input heating source. SOLPS-ITER simulations reproduce experimental conditions with the Bohm diffusion model for both B-field configurations of the PISCES-RF experiment. Major energy loss channels include neutral radiation and power deposited on the wall and dump plate, with only 1% of the input power reaching the target. The ionization front is well confined near the dump plate due to the heating and puffing regions. Additionally, SOLPS-ITER simulation results are also found to be in very good agreement with the particle-in-cell calculations using the code-PICOS++ which supports the validity of SOLPS in low collisionality regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗

High-temperature containerless calorimeter

A high-temperature (greater than 1500 K) containerless calorimeter is described and its usefulness demonstrated. The calorimeter uses the technique of omnidirectional electron bombardment of pendant drops to achieve an isothermal test environment. The small heat input into the sample (i.e., 15-50 W) can be controlled and measured. The apparatus can be used to determine the total hemispherical emissivity, specific heat, heat of fusion, surface tension, and equilibrium melting temperature of small molten drops in the temperature range of 1500 to 3500 K. The total hemispherical emissivity and specific heat of pure niobium and two alloys of niobium-germanium have been measured in the temperature range of 1700 to 2400 K. As reported in the literature, the total hemispherical emissivity varied as a function of temperature. However, specific heat values for both the pure metal and alloys seem to be independent of temperature. Specific heat for the liquid alloy phase was also measured and compared to the solid phase.

Robinson, M. B.↗

Analysis of Heat Transfer from Local Heating and Cooling Sources at Cryogenic Temperatures

Understanding the dispersion of heat around a cryogenic fluid tank, specifically the interaction between the cryogenic fluid and the tank wall is critical in the analysis of long duration cryogen storage in microgravity. The heat transfer interaction between a cryogenic storage tank and heat sources from external spacecraft structures is also one of the many factors that determine how much heat enters a tank. Recent flight experiments with two-phase fluids have indicated that local concentrations of heat input (also known as “hot spots”) can cause unwanted affects including local boiling. Computational fluid dynamic (CFD) models can provide a detailed assessment of the heat transfer occurring across a cryogenic storage system. However, CFD modeling takes time to construct and run. A simpler approach that can act as initial guidance for later CFD modeling analyzes external “hot spots” as point or finite heat sources. A radial, finite element network or a local direct solution can effectively estimate the heat spread across a cryogenic storage tank by calculating the temperature and heat load as a function of distance from the heat source. This calculation accounts for the convective heat transfer between the cryogenic fluid and storage tank surface. Similar approaches can be used to determine the effectiveness of cooling from a cryocooler as a finite, local heat sink. This approach allows for quick approximations of the thermal map across a cryogenic tank as well as sensitivity analysis under a wide range of design parameters including gravitational fields as implied through natural convection coefficients.

Cryogenic Fluid Management↗

Heat Pipes and Heat Rejection Component Testing at NASA Glenn Research Center

Titanium-water heat pipes are being evaluated for use in the heat rejection system for space fission power systems. The heat rejection syst em currently comprises heat pipes with a graphite saddle and a composite fin. The heat input is a pumped water loop from the cooling of the power conversion system. The National Aeronautics and Space Administration has been life testing titanium-water heat pipes as well as eval uating several heat pipe radiator designs. The testing includes thermal modeling and verification of model, material compatibility, frozen startup of heat pipe radiators, and simulating low-gravity environments. Future thermal testing of titanium-water heat pipes includes low-g ravity testing of thermosyphons, radiation testing of heat pipes and fin materials, water pump performance testing, as well as Small Busine ss Innovation Research funded deliverable prototype radiator panels.

Sanzi, James L.↗

A time-dependent gyro-kinetic model of thermal ion upflows in the high-latitude F region

Ample evidence supports the significance of the high-latitude ionospheric contribution to magnetospheric plasma. Assuming flux conservation along a flux tube, the upward field-aligned ion flows observed in the magnetosphere require high-latitude ionospheric field-aligned ion upflows of the order of 10(exp 8) to 10(exp 9)/sq cm/s. Since radar and satellite observations of high-latitude F region flows at times exceed this flux requirement by an order of magnitude, the thermal ionospheric upflows are not simply the ionospheric response to a magnetospheric flux requirement. Several ionospheric ion upflow mechanisms have been proposed, but simulations based on fluid theory do not reproduce all the observed features of ionospheric ion upflows. Certain asymmetries in the statistical morphology of high-latitude F region ion upflows suggest that the ion upflows may be generated by ion-neutral frictional heating. We developed a single-component (O(+)), time-dependent gyro-kinetic model of the high-latitude F region response to frictional heating in which the neutral exobase is a discontinuous boundary between fully collisional and collisionless plasmas. The concept of a discontinuous neutreal exobase and the assumption of a constant and uniform polarization electric field reduce the ion velocity distribution function, from which we can compute the ion density, parallel velocity, parallel and perpendicular temperature, and parallel flux. Using our model, we simulated the response of a convecting flux tube between 500 km and 2500 km to various frictional heating inputs; the results were both qualitatively and quantitatively different from fluid model results, which may indicate an inadequacy of the fluid theory approach. The gyro-kinetic frictional heating model responses to the various simulations were qualitatively similar: (1) initial perturbations of all the modeled parameters propagated rapidly up the flux tube, (2) transient values of the ion parallel velocity, temperature, and flux exceeded 3 km/s, 2 x 10(exp 4) K, and 10(exp 9)/sq cm/s, respectively, (3) a second transient regime developed wherein the parallel temperature drops to very low values (a few hundred Kelvins), and (4) well after heating ceased, large parallel temperatures and large downward parallel velocities and fluxes developed as the flux tube slowly returned to diffusive equilibrium. The ion velocity distributions during the simulation are often non-Maxwellian and are sometimes composed of two distinct ion populations.

Loranc, M.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Heat budget of ionospheric electrons

Heat input calculations were detached from solar extreme UV data and monatomic oxygen densities were derived from simultaneously measured data sets (ion composition 146-191 km) in a study of the heat budget of ionosphere electrons. Earlier inferences that cooling predominates over heating are supported. A search for additional heat sources or a revision of the cooling rates is recommended, by way of balancing the heat budget. Importance is attached to electron cooling by fine structure excitation of monatomic oxygen.

Prasad, S. S.↗

Numerical Analysis of the Transient Response of Advanced Thermal Protection Systems for Atmospheric Entry

Equations for the transfer of heat through thermal protection shields are derived in finite difference form. These equations are applicable to charring ablators, impregnated ceramics, subliming ablators, heat sinks, and insulating materials and have been programed for solution on a high-speed digital computer. In the program, thermal properties can be functions of temperature. Provision is made for analysis of heat shields subjected to simultaneous convective and radiative heat inputs. Some typical results are presented. Limited comparisons with experimental results are made.

THERMAL PROTECTION↗

Powdermet CRADA for VELOCITI Voucher (CRADA Final Report)

NLR shall develop a model of an electric thermal energy storage (ETES) system in the System Advisor Model (SAM) framework that uses a salt and particle slurry developed by PowderMet as the thermal energy storage medium. The ETES shall consist of a recuperated sCO 2 Brayton cycle using 2-tank indirect thermal energy storage and an electric heater for heat input. The salt slurry uses chloride salt and operates at a maximum temperature of 500-720°C. The ETES uses dry air cooling. The salt slurry will be modeled as a sensible heat storage medium and as a latent heat storage medium. NLR will use the model to do parametric analysis of the factors affecting the performance (ex., round trip efficiency) of the ETES system. NLR will work with PowderMet to estimate the costs of system components and total system costs, with the levelized cost of electricity (LCOE) as the primary cost metric.

14 SOLAR ENERGY↗

Thermal structure and energy influx to the day- and nightside Venus ionosphere

The thermal structure of and energy influx to the dayside and nightside Venus ionosphere are discussed, based on data obtained by the Pioneer Venus spacecraft. Where the dayside ionosphere appears relatively constant in total ion concentration, ion and electron temperatures and ion composition below the ionopause, retarding potential analyzer measurements confirm the presence of strong spatial and temporal variations in nightside ion concentration. Ion temperatures on the nightside above 225 km are found to be larger by a factor of two or more than on the dayside, and comparable to electron temperatures on the day and night sides. Models of dayside and nightside ion temperatures consistent with observations require the heat input of 0.003 erg/sq cm sec and 0.005 erg/sq cm sec, respectively, to the ion gas to raise the ion temperature above that of the neutral gas, presumably by means of Joule heating.

Knudsen, W. C.↗

Short-term temporal variations of X-ray bright points

Skylab S-054 data have been used to examine the flux from X-ray bright points with approximately 90 s time resolution. There is evidence of a steady heating input, similar to one reported for active region loops. Also observed are impulsive brightenings of bright points and rapid decays which are consistent with a sudden turn-off of the steady heating.

Nolte, J. T.↗

Distributed Thermal Response Multi-Source Modeling to Evaluate Heterogeneous Subsurface Properties

A thorough assessment of thermal properties in heterogeneous subsurface is necessary in design of low-temperature borehole heat exchangers (BHEs). For this study, a distributed thermal response test (DTRT), which combines distributed temperature sensing (DTS) with a conventional thermal response test (TRT), was conducted in a U-bend geothermal loop installed in an open borehole at the University of Illinois at Urbana-Champaign to estimate thermal properties by analyzing the thermal response of different geologic materials while applying a constant heat input rate. Fiber-optic cables in the DTRT were deployed both inside the U-bend geothermal loop and in the center of the borehole to improve the accuracy of calculated heat-loss rates and borehole temperature profile measurements. To assess the subsurface thermal conductivity during the heating phase of the DTRT, a single-source model and a multi-source model, both based on the infinite line source method, were developed using the borehole temperature data and temperatures inside and along the outside of the loop, separately. The two models returned similar thermal conductivity values. The multi-source modeling has the advantage of predicting the thermal conductivity of heterogeneous geologic materials from borehole temperature profiles during the DTRT heating phase. Additionally, based on the distributed thermal conductivity measured in the borehole, estimates were made for both radial thermal impacts and the rate of heat loss in the BHE.

58 GEOSCIENCES↗