Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Geothermal Energy and Resilience in Arctic Countries

The eight Arctic countries have diverse energy systems but can be split into two distinct groups based on energy characteristics. The first group includes countries which are heavily gridconnected (Iceland, Norway, Sweden, and Finland); the second group includes countries with some grids as well as an abundance of remote microgrids, particularly in their more northern regions (Canada, Russia, the United States [Alaska], and Greenland). The primary energy source for both heat and power in remote communities is almost exclusively diesel. Geothermal energy is currently used in all eight Arctic countries, providing heat and sometimes electricity at utility scales and at the microgrid scale. However, the availability of geothermal resources is poorly defined in Arctic countries. We reframe geothermal heat and power as integrated energy systems, asking the question: are integrated geothermal energy systems - where available and economic - resilient solutions for communities in Arctic countries? Resilience attributes of integrated geothermal energy systems are identified, with a focus on microgrids and small-scale applications.

arctic energy↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid metal walls

Here, the plasma performance of fusion devices depends strongly on the chosen wall materials. Solid plasma-facing components (PFCs) are predominantly used in present devices, and are the most investigated candidates for fusion designs. High-Z materials such as tungsten (W) are the leading solid PFC material candidates. To date, a material choice that scales to steady-state reactor conditions has not been identified. Moreover, if plasma transient events such as edge-localized modes and disruptions cannot be altogether avoided or sufficiently mitigated, the projected peak heat and particle loads far exceed the power exhaust capabilities of solids. Liquid metal (LM) PFCs represent an intrinsic self-healing boundary that are both resilient to surface damage from transients, and that could handle high steady-state heat and particle fluxes. Flowing LM PFCs can be designed to remove “slag,” the buildup of material erosion due to plasma-material interactions, including charge exchange sputtering in the main chamber. Further, LM offer the prospect to manage hydrogenic species otherwise retained in the PFCs, which is important from a safety and inventory standpoint. The two most promising LMs are lithium (Li) and tin (Sn), although Sn–Li eutectics may be considered. While Sn offers a higher temperature window with low vapor pressure and low hydrogen retention, Li offers the prospect of enhanced energy confinement and higher acceptable core contamination limits, and this section focuses on Li PFCs. An LM PFC development research program developed LM PFC concepts for a nuclear fusion device via engineering design calculations, single-effect experiments, and staged prototypical experiments. A self-consistent design window was identified with liquid Li flow speeds ~5–10 m/s; plasma contamination was negligible for predicted Li evolution rates. While these preconceptual designs hold promise, there is substantial R&D needed to advance the technical readiness levels of LM PFCs for application to fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA s Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980's and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to the seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, when the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to asses the compatibility of seal fabrics against ceramic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, J. J.↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA's Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980s and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, then the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to assess the compatability of seal fabrics against cermaic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, Jeffrey J.↗

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

2022 Combined Heat and Power/District Energy System Portfolio Meeting (Summary Report)

The U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office held the 2022 Combined Heat and Power & District Energy System Portfolio Meeting on June 7–9, 2022. The meeting brought together approximately 50 researchers from industry, national laboratories, and research institutes. The purpose of the meeting was for DOE to understand the performance of the projects being sponsored through the CHP program and the status of the technology development, which informs future program planning. This report summarizes the presentations that took place at this event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating Resilience Planning in Distribution System Planning

Electric utilities, regulators, and stakeholders face increasing risks of severe storms, freezes, floods, and heat waves damaging grid infrastructure and causing power outages—and increasing risks of utility equipment igniting wildfires. At the same time, customer electricity rates have risen substantially in recent years, due in part to replacing aging infrastructure and improving resilience to natural hazards and physical threats. To address these challenges, utilities are beginning to move beyond traditional, siloed planning processes to balance resilience with other fundamental grid objectives such as affordability, reliability, safety, and serving new loads. This study presents a framework for states and utilities that want to advance integration of resilience and distribution planning processes to improve planning efficiency, better prioritize cost-effective grid expenditures, and balance planning objectives. The framework includes 7 key integration points between these planning processes: -Strategy process -Data -Threat assessments -Solution identification and prioritization -Optimization opportunities -Consideration of other grid needs -Metrics Lawrence Berkeley National Laboratory reviewed utility distribution system plans and interviewed subject matter experts to identify emerging practices for each of the 7 integration points. This report presents these practices, which can be used as a guide toward more holistic planning and cohesive investment strategies. It also includes 3 case studies to provide practical examples of how utilities apply such integrated planning processes: two pole hardening programs and one microgrid planning effort. The report concludes by identifying opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience assessment and planning in power distribution systems: Past and future considerations

High impact low probability (HILP) events such as hurricanes, heat waves, and floods have instigated widespread power outages and blackouts around the globe in the past decade. With the increasing challenges concerning the threats to the power distribution systems and the growing need to mitigate the impacts of the HILP events, resilience has become a crucial requirement for the power grid infrastructures. Numerous efforts have been made to define, measure, and characterize the resilience of power distribution systems. This study thoroughly reviews the state-of-the-art methods on the existing resilience evaluation framework and metrics. Here, the desirable characteristics of resilience metrics are highlighted, and the challenges associated with formulating, developing, and calculating such metrics are discussed. Next, we detail the state-of-the-art literature on planning solutions to ensure distribution system resilience. This paper aims to extract a deep insight into this challenging and critical research area and envision future opportunities that can guide the power distribution system operators/planners to formulate more effective mitigation strategies to enhance the resilience of power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing a Robust Market for CHP: A Plan for Fostering Economic Development, Business Competitiveness and Resiliency in the Mid-Atlantic Region

The Department of Energy’s Mid Atlantic Combined Heat and Power Technical Assistance Partnership (MA CHP TAP) was established to develop public-private partnerships to advance the technology, policies, and programmatic support for combined heat and power (CHP), including its application in microgrids, heat to power and district energy. The MA CHP TAP’s work includes education and outreach as well as technical assistance to a variety of stakeholders including end-users (commercial, industrial, institutional and more), state decision makers, electric and gas utilities, trade associations and non-profit organizations. This assistance includes evaluating the economic, energy, reliability and environmental value of proposed systems. The MA CHP TAP represents the multi-state Mid- Atlantic region and is the CHP expert in the region who provides fact-based, un-biased information on CHP, including technologies, project development, project financing, local electric and natural gas utility interfaces, and related state best practice policies.

20 FOSSIL-FUELED POWER PLANTS↗

Will cities keep getting hotter? The interplay of urban expansion and greening reshapes future urban heat trajectories

Urban heat islands (UHIs) pose growing risks to public health, infrastructure, and resilience. While often assumed to intensify with urban growth, dynamic changes in urban expansion and vegetation greenness complicate UHI trajectories, which remain poorly understood. This study investigated the interplay of urban expansion and greenness change on UHI spatial profile across 36 Chinese megacities during 2003–2018 using multiple satellite products. We introduce a framework that classifies urban areas into four dynamic development pathways based on impervious surface area (ISA) and enhanced vegetation index (EVI) trends: urbanized-greening, urbanized-browning, urbanizing-greening (UingG), and urbanizing-browning (UingB). While most urbanized centers exhibited greening driven by targeted initiatives and urbanizing suburbs showed browning due to vegetation loss, about 30% urban areas showed the reverse pattern, revealing overlooked complexity in urban development. Urban expansion and browning strengthened UHI in suburban areas, whereas greening initiatives mitigated UHI in urban center and mitigated UHI enhancement in suburban areas. Slowed warming in urban centers together with accelerated warming in suburban areas flattened the temperature gradient between urban centers and suburbs. This dynamic expanded the spatial extent of elevated temperatures and reshaped the classic urban-to-rural UHI profile into a flatter form. In UingB areas, UHI intensification was jointly driven by increase in ISA, vegetation loss, and their interaction, while in UingG areas, EVI increases and a negative interaction together offset over half of the warming driven by urban expansion. These findings reveal that UHI evolution is not unidirectional but depends on localized urbanization and greening dynamics, offering pathways for strategic heat mitigation.

greening initiative↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary System Interface Failure Mode Analysis for Two Advanced Reactors

This study explores two distinct Balance of Plant (BOP) configurations: the Rankine cycle for a sodium-cooled fast reactor (SFR) and the Brayton cycle for a gas-cooled reactor (GCR). As representative designs, the Power Reactor Innovative Small Module (PRISM) by GE Hitachi Nuclear Energy was selected for the SFR, while the Gas Turbine Modular Helium Reactor (GT MHR) by General Atomics was chosen for the gas-cooled reactor. Both configurations were adapted to deliver high-quality heat for industrial applications. A Failure Modes and Effects Analysis (FMEA) was conducted for each system to identify critical failure modes affecting key components. This study marks the first phase of a two-step design optimization approach, integrating FMEA into the design process. Based on the analysis, design modifications and mitigation strategies were proposed to enhance system resilience. The second phase, to be detailed in a subsequent report, will focus on the role of the control system in mitigating these failures. The FMEA serves as a foundation for defining the control topology, ensuring system resilience against component failures that could compromise essential functions, such as electricity and heat production.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AMO Fall 2020 Combined Heat and Power (CHP) Virtual Workshop

The U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office held the Fall 2020 Combined Heat and Power (CHP) Virtual Workshop in September 2020. The workshop brought together more than 90 individuals representing manufacturers, end users, utilities, academia, government, and other stakeholders to discuss the potential role that energy-efficient combined heat and power (CHP) technologies can play in enhancing the energy flexibility and resilience of manufacturing facilities, as well as the advancements needed to bolster technology adoption. This workshop report summarizes the presentations, panel discussions, and breakout group discussions that took place at this event.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Incorporating Combined Heat and Power Modeling into the REopt Lite Web Tool

The National Renewable Energy Laboratory (NREL) is working with project partners to extend the U.S. Department of Energy’s (DOE’s) REopt Lite tool to include combined heat and power (CHP) modeling capabilities. REopt Lite currently provides technoeconomic optimization and resilience analysis for grid-connected solar photovoltaics, (PV), wind, and battery storage at a site. The tool analyzes hourly data across the project lifecycle and evaluates the trade-off between capital costs, operating costs, and savings to find the most cost-effective mix of technologies.

Combined Heat and Power, CHP, Modeling, Tool, Fact↗

Alaska's First Thermalize Campaign: An Effort to Reduce Fuel Reliance in Juneau, AK

In 2018, the Bureau and City of Juneau set the goal of reaching 80% renewable energy in the sectors of transportation and space heating by 2045. This effort will minimize their reliance on fossil fuels, reduce their carbon footprint and increase their resilience in the event of a natural disaster as fuel oil reaches Juneau by boat and such shipments may be disrupted in a disaster. The community's resilience in the face of a disaster and lower carbon footprint goes hand-in-hand with public safety and health. The Cold Climate Housing and Research Center (CCHRC) partnered with several local and statewide groups, including Alaska Heat Smart and Information Insights, Inc, to lead Alaska's first thermalize campaign. Thermalize Juneau 2021 is an energy campaign working to lower the cost of heating homes in Juneau through beneficial electrification and increased energy efficiency. The goal of the campaign was to offer homeowners a streamlined and more affordable way to install heat pumps and energy efficiency improvements into their homes. Converting household heating from fuel to electricity also helps improve indoor and outdoor air quality and reduces maintenance requirements. The campaign had over 160 participants. As of Fall 2021, it is in its final stages of heat pump installations and energy efficiency improvements. In addition to tracking the energy savings and carbon reduction attributed to the campaign, the social equity was an important aspect. Thermalize Juneau attempted to include all the demographics present in Juneau in the campaign. The presentation will cover the goals and implementation of the campaign, current data on how it is improving community and household resilience, lessons learned, and next steps.

clean energy↗