Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Turbulent Acceleration of Interstellar Pickup Ions at the Heliospheric Termination Shock Forms the Global ENA Spectrum

The heliospheric energetic neutral atom spectrum observed by the Interstellar Boundary Explorer (IBEX) reveals that the heliosheath proton distribution is consistent with a power law. The origin of the spectrum is likely from interstellar pickup ions (PUIs) accelerated at the heliospheric termination shock (HTS). We present an explanation of the proton spectrum origin using a test particle simulation of PUIs accelerated at the HTS. PUIs experience preferential heating by the motional electric field in the shock foot, but do not develop a power-law tail without the presence of turbulence at wavenumbers (k) close to the PUI gyroradius scale (R g ). Voyager 2 observations of the magnetic field downstream of the HTS indicate a moderate amount of turbulence at kR g ≅ 1, (δB /B 0 ) 2 @ 0.01, which we find to be sufficient for producing a downstream suprathermal PUI tail but not at intensities observed by IBEX. Within the shock ramp, however, Voyager observed the turbulence power at much smaller scales to be nearly 100 times stronger, suggesting the possibility of strong turbulence at the PUI gyroradius scale. We show that a proton distribution can develop a power law downstream of the HTS consistent with IBEX observations if (δB /B 0 ) 2 ≳ 0.1 at kR g ≅ 1 in the shock foot. Shock drift acceleration of PUIs by the motional electric field is aided by interactions with turbulence upstream of the shock overshoot. Steepening of the IBEX proton spectrum in directions farther from the heliospheric nose suggests the HTS compression ratio and/or turbulence power weakens near the heliotail.

79 ASTRONOMY AND ASTROPHYSICS↗

Reflection and transmission of electromagnetic pulses at a planar dielectric interface -- theory and quantum lattice simulations

There is considerable interest in the application of quantum information science to advance computations in plasma physics. A particular point of curiosity is whether it is possible to take advantage of quantum computers to speed up numerical simulations relative to conventional computers. Many of the topics in fusion plasma physics are classical in nature. In order to implement them on quantum computers it will require couching a classical problem in the language of quantum mechanics. Electromagnetic waves are routinely used in fusion experiments to heat a plasma or to generate currents in the plasma. The propagation of electromagnetic waves is described by Maxwell equations with an appropriate description of the plasma as a dielectric medium. Before advancing to the tensor dielectric of a magnetized plasma, this paper considers electromagnetic wave propagation in a one-dimensional inhomogeneous scalar dielectric. The classic theory of scattering of plane electromagnetic waves at a planar interface, separating two different dielectric media, leads to Fresnel equations for reflection and transmission coefficients. In contrast to plane waves, this paper is on the reflection and transmission of a spatially confined electromagnetic pulse. Following an analytical formulation for the scattering of a Gaussian pulse, it is deduced that the maximum transmission coefficient for a pulse is $\sqrt{n_2/n_1}$ times that for a plane wave; the incident and transmitted pulses propagating in dielectric media with refractive indices $n_1$ and $n_2$, respectively. The analytical theory is complemented by numerical simulations using a quantum lattice algorithm for Maxwell equations. The algorithm, based on the Riemann-Silberstein-Weber representation of the electromagnetic fields and expressed in term of qubits, is an interleaved sequence of entangling operators at each lattice site and unitary streaming operators which transmit information from one site to an adjacent lattice site. Besides substantiating results from the theory for Gaussian pulses, numerical simulations show their validity for non-Gaussian pulses. Apart from their time-asymptotic forms, the simulations display an interplay between the incident, reflected, and transmitted pulses in the vicinity of the transition region between two dielectric media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Intrinsic Junction Thermocouples For Surface Temperature Measurement

The material selection, attachment, and calibration of intrinsic junction thermocouples is discussed. Intrinsic junction thermocouples are utilized for their fast response times in surface measurements during high thermal transients. The as-is measurement and calibrated corrections are presented for both the out-of-pile pulse power system and the critical heat flux experiments in the Idaho National Laboratory Transient Reactor Test facility. The fin effect from temperature measurements on the surface of fuel cladding is corrected using a linear coefficient, m, and temperature corrections are sometimes 100 °C or more—representing 18% of the original temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Ion temperature clamping in Wendelstein 7-X electron cyclotron heated plasmas

The neoclassical transport optimization of the Wendelstein 7-X stellarator has not resulted in the predicted high energy confinement of gas fueled electron-cyclotron-resonance-heated (ECRH) plasmas as modelled in (Turkin et al 2011 Phys. Plasmas 18 022505) due to high levels of turbulent heat transport observed in the experiments. The electron-turbulent-heat transport appears non-stiff and is of the electron temperature gradient (ETG)/ion temperature gradient (ITG) type (Weir et al 2021 Nucl. Fusion 61 056001). As a result, the electron temperature T e can be varied freely from 1 keV–10 keV within the range of P ECRH = 1–7 MW, with electron density n e values from 0.1–1.5 × 10 20 m –3 . By contrast, in combination with the broad electron-to-ion energy-exchange heating profile in ECRH plasmas, ion-turbulent-heat transport leads to clamping of the central ion temperature at T i ~ 1.5 keV ± 0.2 keV. In a dedicated ECRH power scan at a constant density of $\langle n_{e} \rangle$ = 7 × 10 19 m –3 , an apparent 'negative ion temperature profile stiffness' was found in the central plasma for (r/a < 0.5), in which the normalized gradient ∇T i /T i decreases with increasing ion heat flux. The experiment was conducted in helium, which has a higher radiative density limit compared to hydrogen, allowing a broader power scan. This 'negative stiffness' is due to a strong exacerbation of turbulent transport with an increasing ratio of T e /T i in this electron-heated plasma. This finding is consistent with electrostatic microinstabilities, such as ITG-driven turbulence. Theoretical calculations made by both linear and nonlinear gyro-kinetic simulations performed by the GENE code in the W7-X three-dimensional geometry show a strong enhancement of turbulence with an increasing ratio of T e /T i . The exacerbation of turbulence with increasing T e /T i is also found in tokamaks and inherently enhances ion heat transport in electron-heated plasmas. This finding strongly affects the prospects of future high-performance gas-fueled ECRH scenarios in W7-X and imposes a requirement for turbulence-suppression techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaporation due to infrared heating and natural convection

The results obtained from a drying experiment under infrared heating are compared to those obtained from correlations for the mass transfer coefficients, which are commonly used to obtain evaporation rates for drying applications. It was shown that the mass transfer coefficients evaluated by natural convection correlations are approximately ten times lower than those measured under infrared (IR) exposure. In this work, an attempt to explain this discrepancy, which has been also observed in other studies and explained on the basis of thermal radiation effects, optical properties of NMP are presented and the implications of the IR and near infrared (NIR) spectrum on the thermal radiation effects and ensuing evaporation rates are discussed. The results show that expected raise in the film temperature, which would be due to the thermal radiation effects, cannot be used to describe the measured evaporation rates for this solvent. Therefore, this study provides important evaporation mass flux data, which cannot be predicted using traditional correlations, for the design of IR assisted drying systems used in membrane fabrication.

42 ENGINEERING↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Band Heater Heat Flux Characterization Using Inverse Heat Conduction Problem Models

Abstract An experimental apparatus was constructed to correlate water flowrate and temperature rise under an external band heater. Due to the physical characteristics of the band heater, its transient heating behavior is unknown. This paper investigates the application of inverse heat conduction problem (IHCP) methods to characterize the heat flux from the band heater. Three experiments with different heating times (5, 10, and 20 s) and no flowrate were conducted to measure the transient temperature under the 400 W band heater. Type-T thermocouples measure surface temperature at the centerline of the band heater. The experimental results are computed with five different heat conduction models. The models are chosen to identify how the heat flux response varies from a simplified to a realistic model. Additionally, the results of the experimental heat flux are compared to the manufacturer band heater data (58.9 kW/m2) for each model. The minimum time needed for the heater to fully energize the system is from 10 to 12 s. The residuals for each model are analyzed and used to evaluate the appropriateness of the five different models. The results show that the use of simpler models can achieve results similar to those of complex models, with less time and computational cost.

Engineering↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Sea Ice and Cloud Processes Mediating Compensation between Atmospheric and Oceanic Meridional Heat Transports across the CMIP6 Preindustrial Control Experiment

Abstract Bjerknes compensation (BJC) refers to the anticorrelation observed between atmospheric and oceanic heat transport (AHT/OHT) variability, particularly on decadal to longer time scales that may be important to the predictability of the climate system. This study investigates the spread in BJC across fully coupled simulations of phase 6 of the Coupled Model Intercomparison Project (CMIP6) and critical processes (particularly related to sea ice and clouds) that may contribute to that spread. BJC on decadal to longer time scales is confirmed across all the simulations evaluated, and it is strongest in the Northern Hemisphere (NH) between 60° and 70°N. At these latitudes, BJC appears to be primarily driven by the exchange of turbulent fluxes (sensible and latent) in the Greenland, Iceland, and Barents Seas. Metrics to break down how sea ice and clouds uniquely modify the radiative balance of the polar atmosphere during anomalous OHT events are presented. These metrics quantify the impacts of sea ice and clouds on surface and top of atmosphere (latent, sensible, longwave, and shortwave radiative) energy fluxes. Cloud responses tend to counter the clear sky impacts over the Marginal Ice Zone (MIZ). It is further shown that the degree of BJC present in a simulation at high latitudes is heavily influenced by the sensitivity of the sea ice to OHT, which is most influential over the MIZ. These results are qualitatively robust across models and explain the intermodel spread in NH BJC in the preindustrial control experiment.

54 ENVIRONMENTAL SCIENCES↗

Measurement bias in self-heating x-ray free electron laser experiments from diffraction studies of phase transformation in titanium

X-ray self-heating is a common by-product of X-ray Free Electron Laser (XFEL) techniques that can affect targets, optics, and other irradiated materials. Diagnosis of heating and induced changes in samples may be performed using the x-ray beam itself as a probe. However, the relationship between conditions created by and inferred from x-ray irradiation is unclear and may be highly dependent on the material system under consideration. Here, we report on a simple case study of a titanium foil irradiated, heated, and probed by a MHz XFEL pulse train at 18.1 keV delivered by the European XFEL using measured x-ray diffraction to determine temperature and finite element analysis to interpret the experimental data. We find a complex relationship between apparent temperatures and sample temperature distributions that must be accounted for to adequately interpret the data, including beam averaging effects, multivalued temperatures due to sample phase transitions, and jumps and gaps in the observable temperature near phase transformations. The results have implications for studies employing x-ray probing of systems with large temperature gradients, particularly where these gradients are produced by the beam itself. Finally, this study shows the potential complexity of studying nonlinear sample behavior, such as phase transformations, where biasing effects of temperature gradients can become paramount, precluding clear observation of true transformation conditions.

Crystallography↗

Opposite Responses of the Dry and Moist Eddy Heat Transport Into the Arctic in the PAMIP Experiments

Given uncertainty in the processes involved in polar amplification, elucidating the role of poleward heat and moisture transport is crucial. The Polar Amplification Model Intercomparison Project (PAMIP) permits robust separation of the effects of sea ice loss from sea surface warming under climate change. We utilize a moist isentropic circulation framework that accounts for moisture transport, condensation, and eddy transport, in order to analyze the circulation connecting the mid-latitudes and the Arctic. In PAMIP's atmospheric general circulation model experiments, prescribed sea ice loss reduces poleward heat transport (PHT) by warming the returning moist isentropic circulation at high latitudes, while prescribed warming of the ocean surface increases PHT by strengthening the moist isentropic circulation. Inter-model spread of PHT into the Arctic reflects the tug-of-war between sea-ice and surface-warming effects.

58 GEOSCIENCES↗

Graphite resistive heated diamond anvil cell for simultaneous high-pressure and high-temperature diffraction experiments

High-pressure and high-temperature experiments using a resistively heated diamond anvil cell have the advantage of heating samples homogeneously with precise temperature control. Here, we present the design and performance of a graphite resistive heated diamond anvil cell (GRHDAC) setup for powder and single-crystal x-ray diffraction experiments developed at the Extreme Conditions Beamline (P02.2) at PETRA III, Hamburg, Germany. In the GRHDAC, temperatures up to 2000 K can be generated at high pressures by placing it in a water-cooled vacuum chamber. Temperature estimates from thermocouple measurements are within +/–35 K at the sample position up to 800 K and within +90 K between 800 and 1400 K when using a standard seat combination of cBN and WC. Isothermal compression at high temperatures can be achieved by employing a remote membrane control system. Importantly, the advantage of the GRHDAC is demonstrated through the study of geophysical processes in the Earth’s crust and upper mantle region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-jet gas cooling of in-beam foils or specimens: CFD predictions of the convective heat-transfer coefficient

An experiment was designed to investigate the possible enhancement of the convective heat-transfer coefficient by utilizing multiple, parallel jets in the cooling of a small heated surface, such as typically induced by an accelerated ion beam on a thin foil or specimen. The hot spot was provided using a small electrically heated plate. It was found that heat-transfer calculations by means of simple empirical methods based on dimensional analysis are not useful in this case and that advanced computational fluid dynamics (CFD) modelling is essential to interpret the results. It is shown that enhanced convective cooling can indeed be obtained with a multi-jet configuration as compared to a single-jet configuration but only under very selective conditions. An improperly designed multi-jet configuration can also provide significantly reduced cooling relative to the single-jet case and the estimation of the behavior of any particular jet geometry is eminently non-intuitive. CFD provides acceptable quantitative results and seem to be the only tool available to gain an understanding of these complex flows where simple models and “rules of thumb” cannot be relied upon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Cooling Rate and Thermal Mass on Supercooling in a Salt-Hydrogel Complex for Thermal Energy Storage

Glauber’s salt is a promising phase change material for building thermal management because of its high latent heat, acceptable melting temperature of 32.3 °C for indoor air1,2. Despite these advantages, the practical application of Glauber’s salt in thermal energy storage systems is still challenging due to supercooling and phase segregation1–3. Here, we report the impact of temperature ramp rate and thermal mass on the supercooling of Glauber’s salt through the DSC and T-history experiment. The ramp rate effect was studied with a wide range of ramp rates in 1 to 10 °C/min in DSC and 1 to 4 °C/min in the T-history experiment. The thermal mass effect was investigated by comparing DSC and T-history experiment. The latent heat was also analyzed for different ramp rates and thermal mass conditions. The melting temperatures of Glauber’s salt from the two techniques were identical while freezing temperatures were different because of the thermal mass effect. During freezing in the T-history experiment, the latent heat was reduced by around 75% to the latent heat in melting due to supercooling and phase segregation. To overcome this bottleneck, we developed a novel hydrogel complex that reduces the supercooling and prevents phase segregation to maintain volumetric energy density for 100 cycles. Thermodynamic analysis accounting for composition shows that a higher salt composition can further enhance the volumetric energy storage density. For example, a 10% increase in the weight percentage of salt leads to about 50% enhancement in volumetric energy storage density. References: 1. D. R. Biswas, Solar Energy. 19, 99–100 (1977). 2. S. M. Hasnain, Energy Conversion and Management. 39, 1127–1138 (1998). 3. Byung Chul Shin, Sang Done Kim, P. Won-Hoon, Energy. 14, 921–930 (1989).

inorganic, thermodynamics↗