Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A highly reliable RAID system based on GPUs.

While RAID is the prevailing method of creating reliable secondary storage infrastructure, many users desire more flexibility than offered by current implementations. To attain needed performance, customers have often sought after hardware-based RAID solutions. This talk describes a RAID system that offloads erasure correction coding calculations to GPUs, allowing increased reliability by supporting new RAID levels while maintaining high performance.

99 GENERAL AND MISCELLANEOUS↗

Development of a concentrating solar power system using fluidized-bed technology for thermal energy conversion and solid particles for thermal energy storage

Concentrating solar power (CSP) is an effective way to convert solar energy into electricity with an economic energy-storage capability for grid-scale, dispatchable renewable power generation. However, CSP plants need to reduce costs to be competitive with other power generation methods. Two ways to reduce CSP cost are to increase solar-to-electric efficiency by supporting a high-efficiency power conversion system, and to use low-cost materials in the system. The current nitrate-based molten-salt systems have limited potential for cost reduction and improved power-conversion efficiency with high operating temperatures. Even with significant improvements in operating performance, these systems face challenges in satisfying the cost and performance targets. This paper introduces a novel CSP system with high-temperature capability that can be integrated into a high-efficiency CSP plant and that meets the low-cost, high-performance CSP targets. Unlike a conventional salt-based CSP plant, this design uses gas/solid, two-phase flow as the heat-transfer fluid (HTF); separated solid particles as storage media; and stable, inexpensive materials for the high-temperature receiver and energy storage containment. We highlight the economic and performance benefits of this innovative CSP system design, which has thermal energy storage capability for base-load power generation.

14 SOLAR ENERGY↗

Chemically Bonded Phosphorus/Graphene Hybrid as a High Performance Anode for Sodium-Ion Batteries

Room temperature sodium-ion batteries are of great interest for high-energy-density energy storage systems because of low-cost, natural abundance of sodium. Here, we report a novel graphene nanosheets-wrapped phosphorus composite as an anode for high performance sodium-ion batteries though a facile ball-milling of red phosphorus and graphene nanosheets. Not only can the graphene nanosheets significantly improve the electrical conductivity, but they also serve as a buffer layer to accommodate the large volume change of phosphorus in the charge-discharge process. As a result, the graphene wrapped phosphorus composite anode delivers a high reversible capacity of 2077 mAh/g with excellent cycling stability (1700 mAh/g after 60 cycles) and high Coulombic efficiency (>98%). This simple synthesis approach and unique nanostructure can potentially extend to other electrode materials with unstable solid electrolyte interphases in sodium-ion batteries.

chemical bonding↗

Evaluate data lake design for the accelerator control system

Increasing precision in automation for modern particle accelerators not only creates a requirement to gather data from all devices but also demands scalable and high-performance data infrastructure with the capability of handling vast incoming device data. A well architected data lake is suitable for such a system which integrates real-time data acquisition, transient data caching, and long-term storage. This paper evaluates data lake architecture for an Accelerator Control System (ACS), focusing on two critical components of a data lake, data cache and long-term storage.

Jaikar, Amol [Fermilab]↗

Federated Access from DOE Labs to Distributed Storage in the EIC Era of Computing

The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chameleon: An Adaptive Wear Balancer for Flash Clusters

NAND flash-based Solid State Devices (SSDs) offer the desirable features of high performance, energy efficiency, and fast growing capacity. Thus, the use of SSDs is increasing in distributed storage systems. A key obstacle in this context is that the natural unbalance in distributed I/O workloads can result in wear imbalance across the SSDs in a distributed setting. This, in turn can have significant impact on the reliability, performance, and lifetime of the storage deployment. Extant load balancers for storage systems do not consider SSD wear imbalance when placing data, as the main design goal of such balancers is to extract higher performance. Consequently, data migration is the only common technique for tackling wear imbalance, where existing data is moved from highly loaded servers to the least loaded ones. In this paper, we explore an innovative holistic approach, Chameleon, that employs data redundancy techniques such as replication and erasure-coding, coupled with endurance-aware write offloading, to mitigate wear level imbalance in distributed SSD-based storage. Chameleon aims to balance the wear among different flash servers while meeting desirable objectives of: extending life of flash servers; improving I/O performance; and avoiding bottlenecks. Evaluation with a 50 node SSD cluster shows that Chameleon reduces the wear distribution deviation by 81% while improving the write performance by up to 33%.

Zhao, Nannan↗

Development and Performance Evaluation of High Temperature Concrete for Thermal Energy Storage for Solar Power Generation

Thermal energy can be stored by the mechanism of sensible or latent heat or heat from chemical reactions. Sensible heat is the means of storing energy by increasing the temperature of the solid or liquid. Since the concrete as media cost per kWh thermal is $1, this seems to be a very economical material to be used as a TES. This research is focused on extending the concrete TES system for higher temperatures (500 °C to 600 °C) and increasing the heat transfer performance using novel construction techniques. To store heat at high temperature special concretes are developed and tested for its performance. The storage capacity costs of the developed concrete is in the range of $0.91-$3.02/kWh thermal . Two different storage methods are investigated. In the first one heat is transported using molten slat through a stainless steel tube and heat is transported into concrete block through diffusion. The cost of the system is higher than the targeted DOE goal of $15/kWht hermal . The increase in cost of the system is due to stainless steel tube to transfer the heat from molten salt to the concrete blocks.The other method is a one-tank thermocline system in which both the hot and cold fluid occupy the same tank resulting in reduced storage tank volume. In this model, heated molten salt enters the top of the tank which contains a packed bed of quartzite rock and silica sand as the thermal energy storage (TES) medium. The single-tank storage system uses about half the salt that is required by the two-tank system for a required storage capacity. This amounts to a significant reduction in the cost of the storage system. The single tank alternative has also been proven to be cheaper than the option which uses large concrete modules with embedded heat exchangers. Using computer models optimum dimensions are determined to have an round trip efficiency of 84%. Additionally, the cost of the structured concrete thermocline configuration provides the TES capacity cost of $33.80$/kWh thermal compared with $30.04/kWhthermal for a packed-bed thermocline (PBTC) configuration and $46.11/kWh thermal for a two-tank liquid configuration.

14 SOLAR ENERGY↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Halide and Oxy-halide Eutectic Systems for High Performance High Temperature Heat Transfer Fluids

This report presents the work of developing a high temperature heat transfer and thermal storage fluid using low-cost chlorides salts as the basic components. Eutectic mixture of two or three chlorides salts could form a molten salt that can meet the expectation of low freezing point, high boiling point, and low corrosion to high temperature metals. The report includes two parts. Part-A presents the important principles of selecting appropriate constituent chloride salts for the eutectic mixture to have desired thermophysical properties and low corrosion to high temperature metals. Some selections of salt mixtures are listed for theoretical and experimental studies. Thermal and transport properties and heat transfer of four selected mixtures of chloride salts are presented at the end of Part-A. Detailed studies to the corrosion mechanism/behavior of metals in the selected salt mixture at high temperatures are presented in Part-B. Conditioning and purification to the salts are also introduced in Part-B, which is critical to keep the selected chloride salts to have low corrosion to metals at high temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure Slicing: Extending Logical Regions with Fields, In: SC '14: Proceedings of the International Conference for High Performance Computing, Networking, Storage and Analysis

Applications on modern supercomputers are increasingly limited by the cost of data movement, but mainstream programming systems have few abstractions for describing the structure of a program's data. Consequently, the burden of managing data movement, placement, and layout currently falls primarily upon the programmer. To address this problem we previously proposed a data model based on logical regions and described Legion, a programming system incorporating logical regions. In this paper, we present structure slicing, which incorporates fields into the logical region data model. We show that structure slicing enables Legion to automatically infer task parallelism from field non-interference, decouple the specification of data usage from layout, and reduce the overall amount of data moved. We demonstrate that structure slicing enables both strong and weak scaling of three Legion applications including S3D, a production combustion simulation that uses logical regions with thousands of fields, with speedups of up to 3.68X over a vectorized CPU-only Fortran implementation and 1.88X over an independently hand-tuned OpenACC code.

Computer Science↗

Optimization of electrode characteristics for the Br-2/H-2 redox flow cell

The Br-2/H-2 redox flow cell shows promise as a high-power, low-cost energy storage device. The effect of various aspects of material selection, processing, and assembly of electrodes on the operation, performance, and efficiency of the system is determined. In particular, (+) electrode thickness, cell compression, hydrogen pressure, and (-) electrode architecture are investigated. Increasing hydrogen pressure and depositing the (-) catalyst layer on the membrane instead of on the carbon paper backing layers have a large positive impact on performance, enabling a limiting current density above 2 A cm(-2) and a peak power density of 1.4 W cm(-2). Maximum energy efficiency of 79 % is achieved. In addition, the root cause of limiting-current behavior in this system is elucidated, where it is found that Br- reversibly adsorbs at the Pt (-) electrode for potentials exceeding a critical value, and the extent of Br- coverage is potential-dependent. This phenomenon limits maximum cell current density and must be addressed in system modeling and design. These findings are expected to lower system cost and enable higher efficiency.

Tucker, MC↗

Influence of Airflow on Laboratory Storage of High Moisture Corn Stover

Storing high moisture biomass for bioenergy use is a reality in many areas of the country where wet harvest conditions and environmental factors prevent dry storage from being feasible. Aerobic storage of high moisture biomass leads to microbial degradation and self-heating, but oxygen limitation can aid in material preservation. To understand the influence of oxygen presence on high moisture biomass (50 %, wet basis), three airflow rates were tested on corn stover stored in laboratory reactors. Temperature, carbon dioxide production, dry matter loss, chemical composition, fungal abundance, pH, and organic acids were used to monitor the effects of airflow on storage conditions. The results of this work indicate that oxygen availability impacts both the duration of self-heating and the severity of dry matter loss. High airflow systems experienced the greatest initial rates of loss but a shortened microbially active period that limited total dry matter loss (19 %). Intermediate airflow had improved preservation in short-term storage compared to high airflow systems but accumulated the greatest dry matter loss over time (up to 27 %) as a result of an extended microbially active period. Low airflow systems displayed the best performance with the lowest rates of loss and total loss (10 %) in storage at 50 days. Total structural sugar levels of the stored material were preserved, although glucan enrichment and xylan loss were documented in the high and intermediate flow conditions. By understanding the role of oxygen availability on biomass storage performance, the requirements for high moisture storage solutions may begin to be experimentally defined.

09 BIOMASS FUELS↗

Server-side Log Data Analytics for I/O Workload Characterization and Coordination on Large Shared Storage Systems

Inter-application I/O contention and performance interference have been recognized as severe problems. In this work, we demonstrate, through measurement from Titan (world s No. 3 supercomputer), that high I/O variance co-exists with the fact that individual storage units remain under-utilized for the majority of the time. This motivates us to propose AID, a system that performs automatic application I/O characterization and I/O-aware job scheduling. AID analyzes existing I/O traffic and batch job history logs, without any prior knowledge on applications or user/developer involvement. It identifies the small set of I/O-intensive candidates among all applications running on a supercomputer and subsequently mines their I/O patterns, using more detailed per-I/O-node traffic logs. Based on such auto- extracted information, AID provides online I/O-aware scheduling recommendations to steer I/O-intensive applications away from heavy ongoing I/O activities. We evaluate AID on Titan, using both real applications (with extracted I/O patterns validated by contacting users) and our own pseudo-applications. Our results confirm that AID is able to (1) identify I/O-intensive applications and their detailed I/O characteristics, and (2) significantly reduce these applications I/O performance degradation/variance by jointly evaluating out- standing applications I/O pattern and real-time system l/O load.

Liu, Y.↗

Feng shui of supercomputer memory: positional effects in DRAM and SRAM faults. In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Several recent publications confirm that faults are common in high-performance computing systems. Therefore, further attention to the faults experienced by such computing systems is warranted. In this paper, we present a study of DRAM and SRAM faults in large high-performance computing systems. Our goal is to understand the factors that influence faults in production settings. We examine the impact of aging on DRAM, finding a marked shift from permanent to transient faults in the first two years of DRAM lifetime. We examine the impact of DRAM vendor, finding that fault rates vary by more than 4x among vendors. We examine the physical location of faults in a DRAM device and in a data center; contrary to prior studies, we find no correlations with either. Finally, we study the impact of altitude and rack placement on SRAM faults, finding that, as expected, altitude has a substantial impact on SRAM faults, and that top of rack placement correlates with 20% higher fault rate.

Sridharan, Vilas↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Li-Ion Battery Degradation and Performance [Slides]

This presentation is intended for power system engineers, operators, and planners who work on isolated power systems that have (or may soon have) high levels of power generation coming from wind turbines, solar farms, and battery energy storage, which are collectively referred to as inverter-based resources. It describes the basics of lithium-ion battery energy storage systems and lithium-ion battery degradation. Battery degradation at the cell-level is explained, and then the structure and degradation of battery energy storage systems is also explained. This is intended to help power system engineers, operators, and planners to understand and effectively utilize battery energy storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uncovering Access, Reuse, and Sharing Characteristics of I/O-Intensive Files on Large-Scale Production HPC Systems

Large-scale high-performance computing (HPC) applications running on supercomputers produce large amounts of data routinely and store it in files on multi-PB shared parallel storage systems. Unfortunately, storage community has a limited understanding of the access and reuse patterns of these files. This paper investigates the access and reuse patterns of I/O-intensive files on a production-scale supercomputer.

Patel, Tirthak↗

Randomized low-rank decompositions of nuclear three-body interactions

First-principles simulations of many-fermion systems are commonly limited by the computational requirements of processing large data objects. As a remedy, we propose the use of low-rank approximations of three-body interactions, which are the dominant such limitation in nuclear physics. We introduce a randomized decomposition technique to handle the excessively large matrix dimensions and study the sensitivity of low-rank properties to interaction details. The developed low-rank three-nucleon interactions are benchmarked in ab initio simulations of few- and many-body systems. Exploiting low-rank properties provides a promising route to extend the microscopic description of atomic nuclei to large systems where storage requirements exceed the computational capacities of the most advanced high-performance computing facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗