Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Resolutions Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces

Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of the distributed image processing infrastructure to produce the Legacy Survey of Space and Time

The Vera C. Rubin Observatory is preparing to execute the most ambitious astronomical survey ever attempted, the Legacy Survey of Space and Time (LSST). Currently the final phase of construction is under way in the Chilean Andes, with the Observatory’s ten-year science mission scheduled to begin in 2025. Rubin’s 8.4-meter telescope will nightly scan the southern hemisphere collecting imagery in the wavelength range 320–1050 nm covering the entire observable sky every 4 nights using a 3.2 gigapixel camera, the largest imaging device ever built for astronomy. Automated detection and classification of celestial objects will be performed by sophisticated algorithms on high-resolution images to progressively produce an astronomical catalog eventually composed of 20 billion galaxies and 17 billion stars and their associated physical properties. In this article we present an overview of the system currently being constructed to perform data distribution as well as the annual campaigns which reprocess the entire image dataset collected since the beginning of the survey. These processing campaigns will utilize computing and storage resources provided by three Rubin data facilities (one in the US and two in Europe). Each year a Data Release will be produced and disseminated to science collaborations for use in studies comprising four main science pillars: probing dark matter and dark energy, taking inventory of solar system objects, exploring the transient optical sky and mapping the Milky Way. Also presented is the method by which we leverage some of the common tools and best practices used for management of large-scale distributed data processing projects in the high energy physics and astronomy communities. We also demonstrate how these tools and practices are utilized within the Rubin project in order to overcome the specific challenges faced by the Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗

Size-resolved process understanding of stratospheric sulfate aerosol following the Pinatubo eruption

Stratospheric sulfate aerosol produced by volcanic eruptions plays important roles in atmospheric chemistry and the global radiative balance of the atmosphere. The simulation of stratospheric sulfate concentrations and optical properties is highly dependent on the chemistry scheme and microphysical treatment. In this work, we implemented a sophisticated gas-phase chemistry scheme (full chemistry, FC) and a 5-mode version of the Modal Aerosol Module with Prognostic Stratospheric Aerosol (MAM5-PSA) for the interactive treatment of stratospheric sulfate aerosol in the Department of Energy's Energy Exascale Earth System Model version 2 (E3SMv2) model to better simulate the chemistry-aerosol feedback following the Pinatubo eruption, and to compare it against a simulation using simplified chemistry (SC) and the default 4-mode version of the Modal Aerosol Module (MAM4). MAM5-PSA experiments were found to better capture the stratospheric sulfate burden from the eruption of the volcano to the end of 1992 as compared to the High-resolution Infrared Sounder (HIRS) observations, and the formation of sulfate in MAM5-PSA with FC (with an additional OH replenishment reaction) was significantly faster than in MAM4 with FC. Analyses of microphysical processes indicate that more sulfate aerosol mass was generated in total in FC experiments than in SC experiments. MAM5-PSA performs better than MAM4 in simulation of aerosol optical depth (AOD); AOD anomalies from the MAM5-PSA experiment have better agreement with observations. The simulated largest changes in global mean net radiative flux at the top of the atmosphere following the eruption were about −3 W m −2 in MAM5-PSA experiments and roughly −1.5 W m −2 in MAM4 experiments.

AEROSOL↗

Metal ion dopant-induced famatinite to chalcostibite phase transformation of copper antimony sulphide colloidal nanostructures: effect on photophysical and pseudocapacitance properties

Here, the strategic doping of transition metal ions into copper antimony sulphide (CAS) semiconducting nanostructures can significantly influence their photophysical and pseudocapacitive properties, for which there are few reports and therefore is the focus of this study. Accordingly, highly crystalline metal ion (Mn 2+ , Fe 2+ , Co 2+ , Ni 2+ and Zn 2+ ) doped off-stoichiometric copper rich/poor, antimony-rich/poor, and sulphur-poor CAS nanostructures (10–23 nm) were grown via colloidal (hot-injection) synthesis using metal diethyldithiocarbamate precursors. Importantly, metal ion doping significantly influences the structure and composition of the off-stoichiometric CAS nanostructures. Data from powder X-ray diffraction, Raman spectroscopy, high-resolution scanning/transmission electron microscopy, and energy dispersive X-ray spectroscopy confirm that the heavier metal ion dopants induce a novel phase transformation from famatinite (fCAS) to chalcostibite (cCAS) nanostructures. The influence of the metal ion dopants is also observed in the optical properties of as-synthesized nanostructures. This involves blue-shifted ultraviolet-visible absorption, reduced Urbach tailing, and tunable bandgaps between 2.17 and 2.38 eV. Also, the doped nanostructures display broad visible-near infrared photoluminescence via a triple radiative pathway with relatively short decay lifetimes between 0.2 and 6.1 ns. This is mediated by electronic transitions involving intrinsic (copper/antimony/sulphur interstitial) and extrinsic (metal ion interstitial) defect states. Additionally, electrodes prepared from Mn 2+ -doped fCAS nanostructures show enhanced pseudocapacitance via Na+ surface adsorption and intercalation relative to undoped fCAS electrodes, while Zn 2+ -doped cCAS electrodes exhibit pseudocapacitance via a combination of Na+ surface adsorption, intercalation, and redox reactions. These electrodes exhibit reduced charge transfer resistance, improved electronic conductivity and notably enhanced specific capacitance (∼222 F g −1 ), and charge transport, as measured in 1 M Na 2 SO 4 electrolyte via cyclic voltammetry and electrochemical impedance spectroscopy. To this end, the discovery of the metal ion-induced phase transformation presents a new avenue for optimizing the functional properties of fCAS and cCAS nanostructures, highlighting the critical role of metal ion-related defects in controlling the optical and electrochemical properties, towards potential solar absorption and energy storage applications.

25 ENERGY STORAGE↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron emission quasi-optical transmission system on the HL-3 tokamak

A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE 10 mode to the HE 11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. As a result, the newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurement of thermal Knudsen forces in rarefied gas environments

At micro- and nanoscales, momentum transfer between surfaces is influenced by various physical mechanisms, including quantum fluctuations, electromagnetic interactions, electric charges, and the dynamics of (rarefied) gases. Under non-isothermal conditions, rarefied gases give rise to thermal Knudsen forces whose magnitudes strongly depend on the gas species and surface characteristics. Knudsen forces are particularly relevant in nanotechnology, optical manipulation, and aerospace systems, where gas rarefaction occurs due to highly confined geometries, sub-micrometer length scales, and reduced particle densities. Despite their significance, predictive modeling of Knudsen forces is limited by a lack of comprehensive experimental data across diverse materials and surface morphologies. Here, in this work, we present a highly sensitive and adaptable measurement platform capable of directly quantifying Knudsen forces using a suspended, interchangeable micro-cantilever within controlled rarefied helium and nitrogen environments. The system integrates optical fiber interferometry to precisely capture out-of-plane displacements at sub-micrometer resolution, driven by Knudsen forces. From the empirical data, we derive a robust correlation linking the magnitudes of Knudsen forces to energy accommodation coefficients, offering deeper insights into the underlying gas–surface interaction mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unraveling sources of emission heterogeneity in Silicon Vacancy color centers with cryo-cathodoluminescence microscopy

Diamond color centers have proven to be versatile quantum emitters and exquisite sensors of stress, temperature, electric and magnetic fields, and biochemical processes. Among color centers, the silicon-vacancy (SiV - ) defect exhibits high brightness, minimal phonon coupling, narrow optical linewidths, and high degrees of photon indistinguishability. Yet the creation of reliable and scalable SiV - -based color centers has been hampered by heterogeneous emission, theorized to originate from surface imperfections, crystal lattice strain, defect symmetry, or other lattice impurities. Here, we advance high-resolution cryo-electron microscopy combined with cathodolumines cence spectroscopy and 4D scanning transmission electron microscopy (STEM) to elucidate the structural sources of heterogeneity in SiV - emission from nanodiamond with sub-nanometer-scale resolution. Our diamond nanoparticles are grown directly on TEM membranes from molecular-level seedings, representing the natural formation conditions of color centers in diamond. We show that individual subcrystallites within a single nanodiamond exhibit distinct zero-phonon line (ZPL) energies and differences in brightness that can vary by 0.1 meV in energy and over 70% in brightness. These changes are correlated with the atomic-scale lattice structure. We find that ZPL blue shifts result from tensile strain, while ZPL red shifts are due to compressive strain. We also find that distinct crystallites host distinct densities of SiV - emitters and that grain boundaries impact SiV - emission significantly. Finally, we interrogate nanodiamonds as small as 40 nm in diameter and show that these diamonds exhibit no spatial change to their ZPL energy. Our work provides a foundation for atomic-scale structure-emission correlation, e.g., of single atomic defects in a range of quantum and two-dimensional materials.

36 MATERIALS SCIENCE↗

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

X-ray Security Imaging on Personal Dosimetry [Slides]

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz‐Nanoscale Visualization of the Microscopic Spin‐Charge Architecture of Colossal Magnetoresistive Switching

Resolving sub-10 nm spin switching and the associated terahertz (THz) electrodynamics during the colossal magnetoresistance (CMR) transition is a definitive frontier in reaching the fundamental spatial, temporal, and energy-dissipation limits of spin-electronics. Yet, simultaneous control of high magnetic field, cryogenic environment, and nanometer resolution has remained an elusive benchmark for THz nanoscopy, leaving the local THz dynamics of these transitions largely unexplored. Here, we overcome these limitations by utilizing a custom-built cryogenic magneto-THz scattering-type scanning near-field optical microscopy (cm-THz-sSNOM) to resolve the near-field THz spectroscopic evolution of the magnetic field-driven CMR transition in a manganite single crystal. Our measurements provide a nanoscale visualization of the THz conductivity, capturing the moment that magnetic-field-induced spin switching triggers the transition from an antiferromagnetic insulator to a ferromagnetic metal. An ellipsoidal near-field model reveals a multi-scale transition initiated by 1–2 nm isolated spin-flip sites at low magnetic fields, which coalesce into ∼15 nm conducting regions as the threshold field is approached. These results provide an nano-THz view of CMR switching, establishing an analysis framework for mapping spin–charge–lattice–orbit–coupled dynamics at spatial scales that transcend the nominal sSNOM resolution.

Haeuser, Samuel [Iowa State University, Ames, IA (↗