Experimental Simulation of the Interaction of Biased Solar Arrays with the Space Plasma

The phenomenon of unexpectedly large leakage currents collected by small exposed areas of high voltage solar arrays operating in a plasma environment was investigated. Polyimide (Kapton) was the insulating material used in all tests. Both positive bias (electron collection) and negative bias (ion collection) tests were performed. A mode change in the electron collection mechanism was associated with a glow discharge process and was found to be related to the neutral background density. Results indicate that the glow discharge collection mode does not occur in a space environment where the background density is considerably lower than that of the vacuum facility used.

Kaufman, H. R.↗

Sulfur as a surface passivation for InP

The use of liquid and gas phase sulfur pretreatment of the surface of InP as a way to form a near-ideal passivated surface prior to chemical vapor deposition of SiO2 was investigated. Results of high-frequency and quasi-static capacitance-voltage measurements, as well as enhancement mode insulated gate field-effect transistor (FET) transductance and drain current stability studies, all support the efficacy of this approach for metal-insulator-semiconductor application of this semiconductor. In particular, surface state values in the range of 10 to the 10th to a few 10 to the 11th/sq cm per eV and enhancement mode FET drain current drifts of less than 5 percent over a 12 h test period were measured.

Iyer, R.↗

Forcespun Polymers as Precursors to Boron Nitride Fibers

The need for multifunctional materials in aerospace technologies is currently driving the development of new novel composite materials. Specifically, insulation materials with high thermal conductivity, high electrical resistivity, and are chemically inert are needed for high voltage power applications. Boron nitride (BN) nanomaterials fit these criteria and can be incorporated into composites for further material design. The synthesis of boron nitride through a polymer derived ceramic route allows for the morphology of the resulting BN to be tailored. This is especially beneficial since the polymers can be shaped or spun into fibers prior to the ceramic conversion. This project utilizes the Forcespinning technique to produce boron-containing polymer fibers that are converted to boron nitride through a heat treatment. The chemical compositions and fiber morphologies were studied and reported here.

Boron nitride, Fibers, Forcespinning↗

Origin of Capacity Degradation of High-Voltage KVPO 4 F Cathode

Potassium vanadium fluorophosphate (KVPO 4 F) is one of the most promising cathode candidates for K-ion batteries because of its high specific capacity, voltage, and energy density. However, reducing its capacity fade remains an important challenge. This work leverages structure and electrochemical analysis to understand the capacity degradation mechanism of the KVPO 4 F cathode. Interestingly, no structural degradation of the KVPO4F cathode is detected after 200 cycles in the wide voltage window of 5.0-2.5 V (vs K/K + ). Instead, the capacity degradation is attributed to electrolyte decomposition at high voltage ( > 4.5 V vs K/K + ), which causes drying of the electrolyte and the formation of insulating layers on the cathode surface, significantly increasing the polarization. The properties of four KPF 6 - A nd carbonate-based K electrolytes are compared, and 0.7 M KPF 6 in ethylene carbonate/propylene carbonate exhibits the highest oxidation stability and results in the best cycling stability for the KVPO 4 cathode. These findings suggest that the key to improving the cycling stability of KVPO 4 F is to develop novel K electrolytes with even higher oxidation stability.

25 ENERGY STORAGE↗

Interaction of high voltage surfaces with the space plasma

Tests were conducted using plasma densities of approximately 10 to the 5th power - 10 to the 6th power/cu cm. Insulating materials tested were polyimide (Dapton), mica and glass. Surface-area effects were found to be substantially reduced from those previously reported at lower plasma densities. The difference in typical plasma density was felt to be the major cause of this change, although a saturation effect may also be involved. At the 10 to the 5th power/cu cm plasma density range, surface effects on collection current appear limited to roughly 1 cm from the hole. A factor of several reduction of collected current was obtained with both surface scribing and a 2 x 2 cm conducting mesh. It appears possible that the effects of surface treatment might be more significant at lower plasma densities. Effects of repeated tests were also noted, with current collection decreasing with successive tests. Depending on the materials involved, the effect appeared due to either the smoothing of the inside of the insulator hole or the sputtering of insulator on the exposed conductor. A general conclusion was made from a variety of observations, that the generation of vapor is a major factor in the enhancement of collected current.

Kaufman, H. R.↗

Metal vapor arc switch electromagnetic accelerator technology

A multielectrode device housed in an insulator vacuum vessel, the metal vapor vacuum switch has high power capability and can hold off voltages up to the 100 kilovolt level. Such switches can be electronically triggered and can interrupt or commutate at a zero current crossing. The physics of arc initiation, arc conduction, and interruption are examined, including material considerations; inefficiencies; arc modes; magnetic field effects; passive and forced extinction; and voltage recovery. Heating, electrode lifetime, device configuration, and external circuit configuration are discussed. The metal vapor vacuum switch is compared with SCRs, GTOs, spark gaps, ignitrons, and mechanical breakers.

Mongeau, P. P.↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High voltage isolation transformer

A high voltage isolation transformer is provided with primary and secondary coils separated by discrete electrostatic shields from the surfaces of insulating spools on which the coils are wound. The electrostatic shields are formed by coatings of a compound with a low electrical conductivity which completely encase the coils and adhere to the surfaces of the insulating spools adjacent to the coils. Coatings of the compound also line axial bores of the spools, thereby forming electrostatic shields separating the spools from legs of a ferromagnetic core extending through the bores. The transformer is able to isolate a high constant potential applied to one of its coils, without the occurrence of sparking or corona, by coupling the coatings, lining the axial bores to the ferromagnetic core and by coupling one terminal of each coil to the respective coating encasing the coil.

Clatterbuck, C. H.↗

Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration

Two prototype Reconfigurable, Bi-directional Flexfet Level Shifters (ReBiLS) have been developed, where one version is a stand-alone component designed to interface between external low voltage and high voltage, and the other version is an embedded integrated circuit (IC) for interface between internal low-voltage logic and external high-voltage components. Targeting stand-alone and embedded circuits separately allows optimization for these distinct applications. Both ReBiLS designs use the commercially available 180-nm Flex fet Independently Double-Gated (IDG) SOI CMOS (silicon on insulator, complementary metal oxide semiconductor) technology. Embedded ReBiLS circuits were integrated with a Reed-Solomon (RS) encoder using CMOS Ultra-Low-Power Radiation Tolerant (CULPRiT) double-gated digital logic circuits. The scope of the project includes: creation of a new high-voltage process, development of ReBiLS circuit designs, and adjustment of the designs to maximize performance through simulation, layout, and manufacture of prototypes. The primary technical objectives were to develop a high-voltage, thick oxide option for the 180-nm Flexfet process, and to develop a stand-alone ReBiLS IC with two 8-channel I/O busses, 1.8 2.5 I/O on the low-voltage pins, 5.0-V-tolerant input and 3.3-V output I/O on the high-voltage pins, and 100-MHz minimum operation with 10-pF external loads. Another objective was to develop an embedded, rad-hard ReBiLS I/O cell with 0.5-V low-voltage operation for interface with core logic, 5.0-V-tolerant input and 3.3-V output I/O pins, and 100-MHz minimum operation with 10- pF external loads. A third objective was to develop a 0.5- V Reed-Solomon Encoder with embedded ReBilS I/O: Transfer the existing CULPRiT RS encoder from a 0.35-micron bulk-CMOS process to the ASI 180-nm Flexfet, rad-hard SOI Process. 0.5-V low-voltage core logic. 5.0-V-tolerant input and 3.3-V output I/O pins. 100-MHz minimum operation with 10- pF external loads. The stand-alone ReBiLS chip will allow system designers to provide efficient bi-directional communication between components operating at different voltages. Embedding the ReBiLS cells into the proven Reed-Solomon encoder will demonstrate the ability to support new product development in a commercially viable, rad-hard, scalable 180-nm SOI CMOS process.

DeGregorio, Kelly↗

Charge Regulation Stabilizes the Formation of Ionic Liquid‐Based Amphiphilic Oligomer Droplet Interface Bilayers

Amphiphilic charged oligomers (oligodimethylsiloxane – methylimidazolium cation, ODMS-MIM (+) ), assemble into bilayers using the droplet interface bilayer (DIB) platform, possess similar size and functionality as phospholipid bilayers, but exhibit increased stability. The oligomer ionic headgroups (MIM (+) ) are covalently bound to monodisperse, short-chain (n = 13) hydrophobic tails (ODMS). These self-assemble as monolayer brushes at the oil–aqueous interface of water droplets that are influenced by both the charged cationic headgroups, and the nature of the covalently attached tails in the organic phase. Charge regulation (CR) stabilizes the formation of ordered, molecularly close-packed brush phases, which results in highly insulating, stable DIB membranes, with contributions from specific ion-pairing effects, Debye screening, and voltage-dependent electrocompressive stresses. In the oil phase, interactions between hexadecane, a good solvent for ODMS, and the hydrophobic tails result in extended waiting times for bilayer formation compared to phospholipid DIBs, for which hexadecane is a poor solvent. Close agreement between experimental values and predictions for two key parameters, the critical membrane thickness, h c , and maximal grafted headgroup density, Γ 0 , validate an electrostatic CR model consisting of adsorption and partial neutralization of counterions at a charged interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation of Dielectric Heating of Piezoelectric Actuators at Cryogenic Temperatures

The new generation of low beam intensity superconducting linacs will require high accelerating gradients for new scientific discoveries. The high accelerating gradient cavities in pulsed SRF linacs will experience large (~1000’s of Hz) detuning caused by Lorentz force detuning (LFD). The piezo actuators that will be used to compensate large LFD must operate at a nominal voltage of 120V to 150V to deliver the required stroke to the cavity. In this high voltage range, the piezo is expected to warm up drastically due to its location in an insulating vacuum environment. Overheating of the piezo will significantly decrease the longevity of the actuator. A collaboration between FNAL and Physik Instrumente (PI) developed a novel piezo actuator design that mitigates piezo overheating. The design consists of using a metal foam in contact with the piezoelectric ceramic stack for heat removal. The second solution used lithium niobite as an alternative material. A comparison of the temperature stability will be presented and discussed. This study characterizes the dielectric properties for both materials. The results obtained are in the temperature range of 10 K to 300 K.

43 PARTICLE ACCELERATORS↗

Advanced high frequency partial discharge measuring system

This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.

Karady, George G.↗

High Dynamic Voltage Range Studies of Piezoelectric Multilayer Actuators at Low Temperatures

Piezo actuators are used for resonance control in superconducting linacs. In high accelerating gradients linacs, such as those operated in a pulsed mode, the piezos require a large operating voltage. This is due to the Lorentz forced detuning which causes a large frequency shift and is compensated with an active piezo-tuning system. In this high dynamic voltage range the piezo is expected to warm up drastically due to it being in an insulated vacuum. This study characterizes the dielectric properties (capacitance, dielectric losses), the piezo stroke (from geophone), and thermal properties such as heating. Results obtained in the temperature range of 20K to 300K will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Experimental simulation of space plasma interactions with high voltage solar arrays

Operating high voltage solar arrays in the space environment can result in anomalously large currents being collected through small insulation defects. Tests of simulated defects have been conducted in a 45-cm vacuum chamber with plasma densities of 100,000 to 1,000,000/cu cm. Plasmas were generated using an argon hollow cathode. The solar array elements were simulated by placing a thin sheet of polyimide (Kapton) insulation with a small hole in it over a conductor. Parameters tested were: hole size, adhesive, surface roughening, sample temperature, insulator thickness, insulator area. These results are discussed along with some preliminary empirical correlations.

Stillwell, R. P.↗