Search NASA⌕ Search

SEARCH · Search NASA

Results for “High dimensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery↗

High dimensional feature reduction via projection pursuit

The recent development of more sophisticated remote sensing systems enables the measurement of radiation in many more spectral intervals than previously possible. An example of that technology is the AVIRIS system, which collects image data in 220 bands. As a result of this, new algorithms must be developed in order to analyze the more complex data effectively. Data in a high dimensional space presents a substantial challenge, since intuitive concepts valid in a 2-3 dimensional space to not necessarily apply in higher dimensional spaces. For example, high dimensional space is mostly empty. This results from the concentration of data in the corners of hypercubes. Other examples may be cited. Such observations suggest the need to project data to a subspace of a much lower dimension on a problem specific basis in such a manner that information is not lost. Projection Pursuit is a technique that will accomplish such a goal. Since it processes data in lower dimensions, it should avoid many of the difficulties of high dimensional spaces. In this paper, we begin the investigation of some of the properties of Projection Pursuit for this purpose.

Jimenez, Luis↗

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

Gravity, the third dimension of life support in space

The ascent of the human into high altitudes required a 2-D life support system that supplied: oxygen, and heat. At lower altitudes, increased oxygen concentration in the inhaled gases was useful, but at higher altitudes for longer durations, this 'clever' life support approach was no longer adequate--physiologic requirements had to provide a natural pressure-based environment. In space, the life support system requires a third dimension, gravity. Although substituting for gravity has been successful on a limited number of physiologic functions for short-duration stays in space, long durations will require the effects of the real thing for critical physiologic functions. It has been known for over a hundred years that the forces of acceleration (G) and gravity are equivalent. Therefore, gravitational stimulation in space can be achieved with centrifugation. However, for this stimulation to be effective, the dosage of G required to maintain normal physiologic function must be determined. An approximation of this dosage of G for the human can be determined with 3-day bed-rest studies including periodic centrifuge exposure. Recent research on this topic is reviewed.

Burton, Russell R.↗

Development of a High Temperature Heater using an Yttria Stabilized Zirconia Cored Brick Matrix

The Ames pilot heater is a ceramic regenerative heater that provides high temperature air for aerodynamic and combustion experiments. The development of this heater to provide a heat storage bed with temperature capability of about 4600 R is described. A bed was designed and installed having cored brick elements of yttria-stabilized zirconia. The bed dimensions were 14 inches in diameter by 10 feet high. The thermal stress limitations of the bed were studied and maximum air flow rates based upon these limits were established. A combustion reheat system was designed and installed to provide the necessary control over the bed temperature distribution. The revised heater system was successfully operated at a maximum bed temperature of 4600 R. The successful operation demonstrated that yttria-stabilized zirconia cored brick can satisfy the high temperature-long duration requirement for storage heater applications.

Smith, K. W.↗

The measurement of precipitation with synthetic aperture radar

The radar equation for the measurement of precipitation by SAR is identical to that for a conventional radar. The achievable synthetic beamwidth, beta(s), is proportional to sigma(v)/U, the ratio of the spread of the precipitation Doppler spectrum to the platform velocity. Thus, a small beta(s) can be achieved only with small sigma(v) or from a fast-moving vehicle such as a spacecraft. Also, the along-track resolution is variable with sigma(v) and is not known. Nevertheless, the reflectivity is measured correctly. A possible approach to the measurement of sigma(v) is noted. The C-band SAR proposed for the SIR-C mission is capable of detecting a rain rate as small as 0.5 mm/h at nadir when the beam is filled. Because the cross-track beam dimension is about 20 km wide, the use of a high-resolution microwave radiometer to correct for the unfilled beam and the variation of gain across it is suggested. Alternatively, the cross-track dimension should be decreased to no more than about 5 km by increasing the antenna width and/or decreasing the wavelength.

Atlas, David↗

Compact Dielectric-Rod White-Light Delay Lines

Optical delay lines of a proposed type would be made from rods of such dielectric materials as calcium fluoride, fused silica, or sapphire. These would offer advantages over prior optical delay lines, as summarized below. Optical delay lines are key components of opto-electronic microwave oscillators, narrow-band opto-electronic microwave filters, evanescent-field optical biochemical detectors, and some Fourier-Transform spectrum analyzers. Heretofore, optical delay lines used in such applications have been of two types: resonators and coiled long optical fibers, both of which have disadvantages: Resonators are compact, but excitation must be provided by narrow-band lasers. Wide-band (including noisy) laser light cannot be coupled efficiently to narrow-band resonators. When light is coupled into a narrowband resonator from a source of reasonably high power, a significant amount of optical energy circulates within the resonator, causing nonlinear loss and significant noise. Typically, a coil-type optical delay line is made of fused-silica fiber, which exhibits fundamental loss. To overcome the limit imposed by the optical loss in fused silica, it would be necessary to use fibers having crystalline cores. Although space is saved by winding fibers into coils, fiber-coil delay lines are still inconveniently bulky. The proposed compact dielectric-rod delay lines would exploit the special class of non-diffracting light beams that are denoted Bessel beams because their amplitudes are proportional to Bessel functions of the radii from their central axes. High-order Bessel beams can have large values of angular momentum. They can be generated with the help of whispering-gallery-mode optical resonators, as described, for example, in "Simplified Generation of High-Angular-Momentum Light Beams" (NPO-42965) NASA Tech Briefs, Vol. 31, No. 3 (March 2007), page 8a. In a delay line according to the proposal, the dielectric rod would be dimensioned to function as a multimode waveguide. Suitably chosen high-angular-momentum modes in such a waveguide exhibit low group velocity (hence, long delay) and no resonance. Such a delay line could perform well at any wavelength or range of wavelengths within the transparency wavelength band of the dielectric material, and the maximum possible group delay achievable through suitable design would be limited only by the optical loss in the rod material.

Maleki, Lute↗

An implicit algorithm for the transonic full-potential equation in conservative form

A fast, implicit approximate factorization algorithm for the solution of the conservative full-potential equation for transonic flow in two and three dimensions is presented. Stability in supersonic regions is maintained by the use of an upwind evaluation of the density coefficient along all coordinate directions, providing an effective upwind difference of the streamwise terms for any orientation of the velocity vector and thereby enhancing the reliability of the algorithm. The algorithm is shown to provide rapid convergence for the computation of certain difficult two-dimensional test cases, including cases with fishtail shock patterns, demonstrating the reliability and efficiency of the procedure. Surface pressure coefficient distributions obtained by the present method are also found to be in good agreement with those computed by successive-line overrelaxation and a hybrid direct-solver/successive-line overrelaxation scheme, with significant reductions in CPU time required. A three-dimensional solution for a swept wing mounted between parallel walls is also presented which demonstrates the high convergence rate of the algorithm in three dimensions as well as two.

Holst, T.↗

An Integral Field Spectrograph Utilizing Mirrorlet Arrays

An integral field spectrograph (IFS) has been developed that utilizes a new and novel optical design to observe two spatial dimensions simultaneously with one spectral dimension. This design employs an optical 2-D array of reflecting and focusing mirrorlets. This mirrorlet array is placed at the imaging plane of the front-end telescope to generate a 2-D array of tiny spots replacing what would be the slit in a traditional slit spectrometer design. After the mirrorlet in the optical path, a grating on a concave mirror surface will image the spot array and provide high-resolution spectrum for each spatial element at the same time; therefore, the IFS simultaneously obtains the 3-D data cube of two spatial and one spectral dimensions. The new mirrorlet technology is currently in-house and undergoing laboratory testing at NASA Goddard Space Flight Center. Section 1 describes traditional classes of instruments that are used in Heliophysics missions and a quick introduction to the new IFS design. Section 2 discusses the details of the most generic mirrorlet IFS, while section 3 presents test results of a lab-based instrument. An example application to a Heliophysics mission to study solar eruptive events in extreme ultraviolet wavelengths is presented in section 4 that has high spatial resolution (0.5 arc sec pixels) in the two spatial dimensions and high spectral resolution (66 m) across a 15 spectral window. Section 4 also concludes with some other optical variations that could be employed on the more basic IFS for further capabilities of this type of instrument.

Chamberlin, Phillip C.↗

High resolution visible to short-wave near-infrared CCD spectra of Mars during 1990

The 0.4 to 1.0 micron spectrum of Mars is dominated by a steep red, relatively featureless spectral slope. Earlier lower spectral observations interpreted the red color and the lack of absorption features in the spectra as evidence of poorly crystalline ferric oxide minerals. More recent higher spectral resolution observations and reinterpretations of older data sets have revealed measureable spectral structure, however. For example, absorption features near 0.65 and 0.86 micron were detected and spatially mapped in data obtained during the 1988 opposition. These absorptions were interpreted as evidence for crystalline hematite on Mars, occuring as an accessory phase in abundances of 3 to 6 percent in the soil. We are attempting to verify the existence of these subtle crystalline Fe(3+) absorption features and to map their spatial distribution in regions of the planet not imaged in 1988. During the 1990 opposition, we obtained imaging spectroscopic data of Mars from the University of Hawaii 2.24 m telescope at Mauna Kea Observatory. The data were obtained with the Wide Field Grism Spectrograph (WFGS), which uses an 800 x 800 CCD and a transmission grating ruled on a prism. We used a grating blazed at 4800 A in first order to obtain data from 0.50 to 0.94 micron at a spectral resolution of R = 200 to 350. The moon/Mars slit design used had projected dimensions of 0.29 x 153 inches, allowing for high spectral resolution and adequate cross-slit spatial sampling of the Martian disk.

Bell, James F., III↗

A High-Order Eulerian–Lagrangian Runge–Kutta Finite Volume (EL–RK–FV) Method for Scalar Nonlinear Conservation Laws

Abstract We present a class of high-order Eulerian–Lagrangian Runge–Kutta finite volume methods that can numerically solve Burgers’ equation with shock formations, which could be extended to general scalar conservation laws. Eulerian–Lagrangian (EL) and semi-Lagrangian (SL) methods have recently seen increased development and have become a staple for allowing large time-stepping sizes. Yet, maintaining relatively large time-stepping sizes post shock formation remains quite challenging. Our proposed scheme integrates the partial differential equation on a space-time region partitioned by linear approximations to the characteristics determined by the Rankine–Hugoniot jump condition. We trace the characteristics forward in time and present a merging procedure for the mesh cells to handle intersecting characteristics due to shocks. Following this partitioning, we write the equation in a time-differential form and evolve with Runge–Kutta methods in a method-of-lines fashion. High-resolution methods such as ENO and WENO-AO schemes are used for spatial reconstruction. Extension to higher dimensions is done via dimensional splitting. Numerical experiments demonstrate our scheme’s high-order accuracy and ability to sharply capture post-shock solutions with large time-stepping sizes.

Chen, Jiajie↗

Modal ring method for the scattering of sound

The modal element method for acoustic scattering can be simplified when the scattering body is rigid. In this simplified method, called the modal ring method, the scattering body is represented by a ring of triangular finite elements forming the outer surface. The acoustic pressure is calculated at the element nodes. The pressure in the infinite computational region surrounding the body is represented analytically by an eigenfunction expansion. The two solution forms are coupled by the continuity of pressure and velocity on the body surface. The modal ring method effectively reduces the two-dimensional scattering problem to a one-dimensional problem capable of handling very high frequency scattering. In contrast to the boundary element method or the method of moments, which perform a similar reduction in problem dimension, the model line method has the added advantage of having a highly banded solution matrix requiring considerably less computer storage. The method shows excellent agreement with analytic results for scattering from rigid circular cylinders over a wide frequency range (1 is equal to or less than ka is less than or equal to 100) in the near and far fields.

Baumeister, Kenneth J.↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Orientation-dependent mutual crystalline and amorphous order in a single phase solid

Amorphous materials distinguish themselves from crystalline materials by lacking long-range order while retaining structural order at the local scale (2–5 Å). However, the complexity in topological and chemical order prevents current characterization tools from fully unveiling the structure in disordered materials. Consequently, the nature of medium-range order in amorphous materials has remained elusive. The Zachariasen and crystal competing models have been proposed to describe disordered phases and have both been verified through synthesis and characterization. The main difference between them is thought to be whether the amorphous phase shows medium-range order. Here we demonstrate a form of organized inorganic matter that is amorphous in two dimensions, while exhibiting long-range order and a high degree of crystallinity in the third. The structure consists of periodically stacked 2-dimensional amorphous Nb-W-O monolayers without long-range in-plane order. The unique periodic and therefore crystalline stacking along one principal axis enables direct imaging and revealed that the amorphous Nb-W-O monolayers formed in agreement with the Zachariasen model for 2 dimensions. Our findings show that the gap between crystalline and amorphous materials does not only depend on medium-range order but can also apply to principal dimensions within the same solid.

Nanowires↗

Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System

A microfabrication process is proposed to produce a nanopore membrane for continuous passive drug release to maintain constant drug concentrations in the patient s blood throughout the delivery period. Based on silicon microfabrication technology, the dimensions of the nanochannel area, as well as microchannel area, can be precisely controlled, thus providing a steady, constant drug release rate within an extended time period. The multilayered nanochannel structures extend the limit of release rate range of a single-layer nanochannel system, and allow a wide range of pre-defined porosity to achieve any arbitrary drug release rate using any preferred nanochannel size. This membrane system could also be applied to molecular filtration or isolation. In this case, the nanochannel length can be reduced to the nanofabrication limit, i.e., 10s of nm. The nanochannel delivery system membrane is composed of a sandwich of a thin top layer, the horizontal nanochannels, and a thicker bottom wafer. The thin top layer houses an array of microchannels that offers the inlet port for diffusing molecules. It also works as a lid for the nanochannels by providing the channels a top surface. The nanochannels are fabricated by a sacrificial layer technique that obtains smooth surfaces and precisely controlled dimensions. The structure of this nanopore membrane is optimized to yield high mechanical strength and high throughput.

Ferrari, Mauro↗

Taylor approximation variance reduction for approximation errors in PDE-constrained Bayesian inverse problems

In numerous applications, surrogate models are used as a replacement for accurate parameter-to-observable mappings when solving large-scale inverse problems governed by partial differential equations (PDEs). The surrogate model may be a computationally cheaper alternative to the accurate parameter-to-observable mappings and/or may ignore additional unknowns or sources of uncertainty. The Bayesian approximation error (BAE) approach provides a means to account for the induced uncertainties and approximation errors, i.e. the errors between the accurate parameter-to-observable mapping and the surrogate. The statistics of these errors are, however, in general unknown a priori, and are thus calculated using Monte Carlo sampling. Although the sampling is typically carried out offline, i.e. before considering the data, the process can still represent a computational bottleneck. In this work, we develop a scalable computational approach for reducing the costs associated with the sampling stage of the BAE approach. Specifically, we consider the Taylor expansion of the accurate and surrogate forward models with respect to the uncertain parameter fields either as a control variate for variance reduction or as a means to directly and efficiently approximate the mean and covariance of the approximation errors. We propose efficient methods for evaluating the expressions for the mean and covariance of the Taylor approximations based on linear(-ized) PDE solves. Furthermore, the proposed approach is independent of the dimension of the uncertain parameter, depending instead on the intrinsic dimension of the data, ensuring scalability to high-dimensional problems. The potential benefits of the proposed approach are demonstrated for two high-dimensional inverse problems governed by PDE examples, namely for the estimation of a distributed Robin boundary coefficient in a linear diffusion problem, and for a coefficient estimation problem governed by a nonlinear diffusion problem.

Bayesian approximation error↗

Uniform Field Electrode Generator

SAND2025-03788O Uniform Field Electrode Generator is a user-friendly tool designed to create uniform electric field electrodes, essential for high voltage applications. By generating electrodes with precise dimensions, it ensures a consistent electric field across their surfaces. This software is particularly beneficial for researchers and engineers working on projects like closing switches and studying power flow in advanced systems, such as the Z machine. Its unique approach simplifies the design process, making it accessible for users without technical expertise, while enhancing the efficiency and effectiveness of their electrical applications. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Mason, Tyler [Sandia National Lab. (SNL-CA), Liver↗

Utah FORGE: Seismic DAS and Geophone Borehole Data Processing and 3D Imaging of Vp/Vs Ratio in the 2024 Stimulated Reservoir

This dataset includes a final report and a 3D velocity model derived from seismic DAS and geophone borehole data collected during the April 2024 stimulation of the reservoir at Utah FORGE. The report details the processing of over 50,000 P- and S-wave travel times used in a tomographic inversion to estimate the Vp/Vs ratio, revealing anomalies adjacent to wells 16A and 16B that may be associated with injected fracturing fluids. Additionally, Wadati analysis of more than 27,000 pairs of differential P- and S-wave travel times supports this interpretation with a high Vp/Vs estimate of 1.86, averaged over the dimensions of the earthquake cluster. The accompanying data file provides a 3D model of P- and S-wave velocities and Vp/Vs ratios, structured with spatial coordinates and velocity values.

15 GEOTHERMAL ENERGY↗