Search NASA⌕ Search

SEARCH · Search NASA

Results for “Humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NREL ASSIST Barge / Thermodynamic retrievals TROPoe v0.19

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe v0.19 (Turner and Löhnert, 2014; Turner and Blumberg, 2019; Turner and Löhnert, 2021). The profiles are retrieved every 10 minutes from instantaneous observations from the NREL ASSIST-II (SN 12) infrared spectrometer. Observations are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from a collocated NREL Vaisala CL51 ceilometer (when available) or vertically staring Halo XR lidar, and surface temperature, relative humidity, and pressure from the collocated Oregon State University met tower. The full pipeline to run the retrieval is available at https://github.com/StefanoWind/TROPoe_processor. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al., 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Rhode Island Site - NREL ASSIST Thermodynamic Retrievals TROPoe v0.19 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe v0.19 (Turner and Löhnert, 2014; Turner and Blumberg, 2019; Turner and Löhnert, 2021). The profiles are retrieved every 10 minutes from instantaneous observations from the NREL ASSIST-II (SN 12) infrared spectrometer. Observations are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from the collocated NREL upgraded Galion lidar (Newsom et al., 2019), and surface temperature, relative humidity, and pressure from the collocated PNNL met tower. The full pipeline to run the retrieval is available at https://github.com/StefanoWind/TROPoe_processor. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al., 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗

Strategic Siting of Direct Air Capture Facilities in the United States

Direct air capture (DAC) systems that capture carbon dioxide (CO 2 ) directly from the atmosphere are garnering considerable attention for their potential role as negative emission technologies in achieving net-zero CO 2 emission goals. Common DAC technologies are based either on liquid–solvent (L-DAC) or solid–sorbent (S-DAC) to capture CO 2 . A comprehensive multi-factor comparative economic analysis of the deployment of L-DAC and S-DAC facilities across various United States (U.S.) cities is presented in this paper. The analysis considers the influence of various factors on the favorability of DAC deployment, including local climatic conditions such as temperature, humidity, and CO 2 concentrations; the availability of energy sources to power the DAC system; and costs for the transport and storage of the captured CO 2 along with the consideration of the regional market and policy drivers. The deployment analysis in over 70 continental U.S. cities shows that L-DAC and S-DAC complement each other spatially, as their performance and operational costs vary in different climates. L-DAC is more suited to the hot, humid Southeast, while S-DAC is preferrable in the colder, drier Rocky Mountain region. Strategic deployment based on regional conditions and economics is essential for promoting the commercial adoptability of DAC, which is a critical technology to meet the CO 2 reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implications of reduced-complexity aerosol thermodynamics on organic aerosol mass concentration and composition over North America

Atmospheric organic aerosol (OA) mass concentrations can be affected by water uptake through its impact on the gas–particle partitioning of semi-volatile compounds. Current chemical transport models (CTMs) neglect this process. We have implemented the Binary Activity Thermodynamics model coupled to a volatility basis set partitioning scheme in the GEOS-Chem CTM, providing an efficient reduced-complexity OA model that predicts relative-humidity-dependent mixing and partitioning thermodynamics, while limiting the impact on computational efficiency. We provide a quantitative assessment of this water-sensitive OA treatment, focusing on a subdomain over North America. The updated OA scheme predicts a spatiotemporal mean enhancement in surface-level OA mass concentration of 145 % for January 2019 and 76 % for July 2019 compared to GEOS-Chem's most advanced OA scheme. The temporal mean surface-level OA organic mass concentration can increase by up to ∼590 % for January 2019 and ∼280 % for July 2019, with the greatest enhancements occurring over the ocean. The updated OA scheme also quantifies the OA-associated water content. The simulations show how different OA precursors and related OA surrogates contribute and respond to water uptake, including that due to changes in temperature and relative humidity over the diurnal cycle in selected winter and summer months. These results are independent of future CTM improvements involving updates to chemical reaction schemes and emission inventories. Our water-sensitive OA scheme allows for a better representation of the seasonal and regional variations in OA mass concentration in CTMs.

54 ENVIRONMENTAL SCIENCES↗

Uncertainties in the effects of organic aerosol coatings on polycyclic aromatic hydrocarbon concentrations and their estimated health effects

We used the CAM5 model to examine how different particle-bound polycyclic aromatic hydrocarbon (PAH) degradation approaches affect the spatial distribution of benzo(a)pyrene (BaP). Three approaches were evaluated: NOA (no effect of OA coatings state on BaP), shielded (viscous OA coatings shield BaP from oxidation under cool and dry conditions) and ROI-T (viscous OA coatings slow BaP oxidation in response to temperature and humidity). Results show that BaP concentrations vary seasonally, influenced by emissions, deposition, transport and degradation approach, all of which are influenced by meteorological conditions. All simulations predict higher population-weighted global average (PWGA) fresh BaP concentrations during December–January–February (DJF) compared to June–July–August (JJA), due to increased emissions from household activities and reduced removal processes during colder months. The shielded and ROI-T approaches, which account for OA coatings, result in 2–6 times higher BaP concentrations in DJF compared to NOA. The shielded simulation predicts the highest PWGA fresh BaP concentration (1.3 ng m −3 ), with 90 % of BaP protected from oxidation. In contrast, the ROI-T approach forecasts lower concentrations in middle to low latitudes, as it assumes less effective OA coatings under warmer, more humid conditions. Evaluations against observed BaP concentrations show the shielded approach performs best, with a normalized mean bias (NMB) within ± 20 %. The combined incremental lifetime cancer risk (ILCR) for both fresh and oxidized PAHs is similar across simulations, emphasizing the importance of considering both forms in health risk assessments. This study highlights the critical role of accurate degradation approaches in PAH modeling.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Observing low-altitude features in ozone concentrations in a shoreline environment via uncrewed aerial systems

Abstract. Ozone is a pollutant formed in the atmosphere by photochemical processes involving nitrogen oxides (NOx) and volatile organic compounds (VOCs) when exposed to sunlight. Tropospheric boundary layer ozone is regularly measured at ground stations and sampled infrequently through balloon, lidar, and crewed aircraft platforms, which have demonstrated characteristic patterns with altitude. Here, to better resolve vertical profiles of ozone within the atmospheric boundary layer, we developed and evaluated an uncrewed aircraft system (UAS) platform for measuring ozone and meteorological parameters of temperature, pressure, and humidity. To evaluate this approach, a UAS was flown with a portable ozone monitor and a meteorological temperature and humidity sensor to compare to tall tower measurements in northern Wisconsin. In June 2020, as a part of the WiscoDISCO20 campaign, a DJI M600 hexacopter UAS was flown with the same sensors to measure Lake Michigan shoreline ozone concentrations. This latter UAS experiment revealed a low-altitude structure in ozone concentrations in a shoreline environment showing the highest ozone at altitudes from 20–100 m a.g.l. These first such measurements of low-altitude ozone via a UAS in the Great Lakes region revealed a very shallow layer of ozone-rich air lying above the surface.

Meteorology & Atmospheric Sciences↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty-informed selection of CMIP6 Earth System Model subsets for use in multisectoral and impact models

Earth system models (ESMs) and general circulation models (GCMs) are heavily used to provide inputs to sectoral impact and multisector dynamic models, which include representations of energy, water, land, economics, and their interactions. Therefore, representing the full range of model uncertainty, scenario uncertainty, and interannual variability that ensembles of these models capture is critical to the exploration of the future co-evolution of the integrated human–Earth system. The pre-eminent source of these ensembles has been the Coupled Model Intercomparison Project (CMIP). With more modeling centers participating in each new CMIP phase, the size of the model archive is rapidly increasing, which can be intractable for impact modelers to effectively utilize due to computational constraints and the challenges of analyzing large datasets. In this work, we present a method to select a subset of the latest phase, CMIP6, featuring models for use as inputs to a sectoral impact or multisector dynamics models, while prioritizing preservation of the range of model uncertainty, scenario uncertainty, and interannual variability in the full CMIP6 ensemble results. This method is intended to help impact modelers select climate information from the CMIP archive efficiently for use in downstream models that require global coverage of climate information. This is particularly critical for large-ensemble experiments of multisector dynamic models that may be varying additional features beyond climate inputs in a factorial design, thus putting constraints on the number of climate simulations that can be used. We focus on temperature and precipitation outputs of CMIP6 models, as these are two of the most used variables among impact models, and many other key input variables for impacts are at least correlated with one or both of temperature and precipitation (e.g., relative humidity). Besides preserving the multi-model ensemble variance characteristics, we prioritize selecting CMIP6 models in the subset that preserve the very likely distribution of equilibrium climate sensitivity values as assessed by the latest Intergovernmental Panel on Climate Change (IPCC) report. This approach could be applied to other output variables of climate models and, possibly when combined with emulators, offers a flexible framework for designing more efficient experiments on human-relevant climate impacts. It can also provide greater insight into the properties of existing CMIP6 models.

Snyder, Abigail C.↗

EPCAPE-PT-LANL Measurements: PM Modulair 1

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Quant-AQ MODULAIR. Mounted external to the instrument container, near the GCVI inlet. The MODULAIR™ air quality monitor uses the same patent-pending PM sensor found in the MODULAIR™-PM and adds four gas-phase measurements (CO, NO, NO2, and O3) to provide an all-in-one solution. Files data_10sec_Quant_Gas.csv, data_10min_Quant_Gas.csv Header: - CO[ppb]: Concentration of carbon monoxide (CO) measured at the time of sampling, expressed in parts per billion (ppb) - NO[ppb]: Concentration of nitric oxide (NO) measured at the time of sampling, expressed in parts per billion (ppb). - O3[ppb]: Concentration of ozone (O3) measured at the time of sampling, expressed in parts per billion (ppb). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. Files data_10sec_Quant_PM.csv, data_10min_Quant_PM.csv Header: - PM1[ug/m3]: Concentration of particulate matter with a diameter of 1 micron or less, measured in micrograms per cubic meter (µg/m³). - PM2-5[ug/m3]: Concentration of particulate matter with a diameter of 2.5 microns or less measured in micrograms per cubic meter (µg/m³). - PM10[ug/m3]: Concentration of particulate matter with a diameter of 10 microns or less, measured in micrograms per cubic meter (µg/m³). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage.

54 ENVIRONMENTAL SCIENCES↗

Back Trajectories during SAIL

This data set contains air mass back trajectories generated during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign using the Hybrid Single-Particle Lagrangian Integrated Trajectory model (HYSPLIT, Stein et al. 2015, Rolph et al. 2017). For each hour from January 1, 2021 to June 30, 2023, a 96-hour back trajectory was initiated at the SAIL sampling site, starting 100 m above ground level. The calculations used the GDAS meteorological data set with model vertical velocity. The files within this dataset show location and meteorological parameters of the back trajectory analysis. There are 21 columns within each data file. The first 2 columns pertain to back trajectory parameters: the trajectory number (which is always 1) and the meteorological grid number. The next 9 columns pertain to spatiotemporal information: the year, month, day, hour (0-23), and minute of the trajectory, the previous time of the trajectory (in negative hours), and the airmass location (latitude, longitude, and height in m AGL). The rest of the parameters within each file pertains to surface and meteorological characteristics of the airmass: pressure (in hPa), potential temperature (in K), temperature (in K), precipitation rate (in mm/hr), mixing depth (in m), relative humidity (in % relative to liquid water), specific humidity (in g/kg), H2O mixing ratio (in g/kg), underlying terrain height (in meters above sea level), and incoming radiation (in W/m^2).

back trajectory↗

Surface ozone and meteorological variables at CoURAGE TBS site during summer IOP

This dataset provides continuous near ground-level in situ ozone and meteorological data at the TBS site (S7) during the CoURAGE summer IOP. The ozone inlet and the weather station were approximately 5 meters above the surface. In situ ozone (ppbv) was collected with a 2BTech Model 205 dual beam ozone monitor. The meteorological data (temperature, pressure, relative humidity, wind speed, and wind direction) was collected with an AIRMAR 220WX WeatherStation Instrument with relative humidity (RH) module. The data has 2-second temporal resolution.

bar_pres↗

Particle_hygroscopicity_growth_factor_HFIMS_TRACER_2022_HOUSTON_IOP

This dataset contains high-temporal-resolution measurements of hygroscopic growth factors (GF), and instrument diagnostic/environmental parameters collected during the TRACER campaign using a coupled Differential Mobility Analyzer (DMA) and Fast Integrated Mobility Spectrometer (FIMS) system (HFIMS). The dataset consists of 49,645 time steps and covers 20 discrete growth factor bins (FIMS_GFbinc). The primary data product is the Probability Density Function (FIMS_cPDF), which characterizes aerosol hygroscopic growth behavior under controlled relative humidity conditions. Instrument operational parameters, including flow temperatures, relative humidities, pressures, and counts for both DMA and FIMS, are provided for quality assurance.

DMA_Dp_mean↗

Package Data for CERF-Data Centers

This dataset contains sample input 100m resolution raster files for running the CERF-DC python package (see https://github.com/IMMM-SFA/cerf_data_centers) at the state level across the CONUS. Due to data availability constraints, some of the items included in this dataset are proxies or assumptions for siting factors used in the model. These are individually noted in the item descriptions and can be exchanged with more detailed information upon availability. Data Descriptions The following raster files are included in the data download: state_siting_region.tif — State areas identified by state FIPS code composite_siting_suitability.tif — Value of 1 indicates suitable siting location, 0 otherwise. The following areas are excluded from siting: Areas within 300m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds Developed lands Areas >0.8 km (0.5 miles) from developed lands land_value_dollar_per_sqft.tif — USD per square foot (sqft) derived from USDA $/acre land cost personal_property_tax_rate.tif — Personal property tax rate by state. Uses an assumed 0.0125 personal property tax rate for states with personal property tax, 0 for states without personal property tax. real_property_tax_rate.tif — Real property tax rate. Based on county level residential real estate property tax rates. sales_tax_rate.tif — Sales tax rate by state. mechanical_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through mechanical processes based on local water stress and humidity levels. water_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through evaporative (water cooled) processes based on local water stress and humidity levels. distance_to_substation.tif — Distance to nearest substation in hundreds of meters (i.e., value of 1 equals a distance of 100m). Offshore areas have a value of 0. industrial_electricity_rates_dollar_per_kwh.tif — USD/kWh industrial electricity rates. Represents the average industrial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. commercial_electricity_rates_dollar_per_kwh.tif — USD/kWh commercial electricity rates. Represents the average commercial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. data_center_market_locations.tif — Grid cells with positive values represent the centroid of existing data center market clusters. The value of non-zero grid cells represents the number of data centers in the market cluster. All other grid cells have a value of 0. Geospatial Metadata CRS: Albers Equal Area Conic (ESRI:102003) Extent: -2415585.0000000023283064,-1441981.2605773280374706 : 2384414.9999999976716936,1708018.7394226719625294 Dimensions: X: 48000 Y: 31500 Bands: 1 Origin: -2415585.0000000023283064,1708018.7394226719625294 Pixel Size: 100,-100 Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall↗

Package Data for CERF-Data Centers

This dataset contains sample input 100m resolution raster files for running the CERF-DC python package (see https://github.com/IMMM-SFA/cerf_data_centers) at the state level across the CONUS. Due to data availability constraints, some of the items included in this dataset are proxies or assumptions for siting factors used in the model. These are individually noted in the item descriptions and can be exchanged with more detailed information upon availability. Data Descriptions The following raster files are included in the data download: state_siting_region.tif — State areas identified by state FIPS code composite_siting_suitability.tif — Value of 1 indicates suitable siting location, 0 otherwise. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands land_value_dollar_per_sqft.tif — USD per square foot (sqft) derived from USDA $/acre land cost personal_property_tax_rate.tif — Personal property tax rate by state. Uses an assumed 0.0125 personal property tax rate for states with personal property tax, 0 for states without personal property tax. real_property_tax_rate.tif — Real property tax rate. Based on county level residential real estate property tax rates. sales_tax_rate.tif — Sales tax rate by state. mechanical_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through mechanical processes based on local water stress and humidity levels. water_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through evaporative (water cooled) processes based on local water stress and humidity levels. distance_to_substation.tif — Distance to nearest substation in hundreds of meters (i.e., value of 1 equals a distance of 100m). Offshore areas have a value of 0. industrial_electricity_rates_dollar_per_kwh.tif — USD/kWh industrial electricity rates. Represents the average industrial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. commercial_electricity_rates_dollar_per_kwh.tif — USD/kWh commercial electricity rates. Represents the average commercial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. data_center_market_locations.tif — Grid cells with positive values represent the centroid of existing data center market clusters. The value of non-zero grid cells represents the number of data centers in the market cluster. All other grid cells have a value of 0. Geospatial Metadata CRS: Albers Equal Area Conic (ESRI:102003) Extent: -2415585.0000000023283064,-1441981.2605773280374706 : 2384414.9999999976716936,1708018.7394226719625294 Dimensions: X: 48000 Y: 31500 Bands: 1 Origin: -2415585.0000000023283064,1708018.7394226719625294 Pixel Size: 100,-100 Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall↗

Determining the Crosslinking and Degradation Reaction Kinetics in Photovoltaic Encapsulants Using Accelerated Aging: Preprint

Degradation of photovoltaic (PV) module encapsulant mechanical characteristics that lead to embrittlement and delamination remains a cause of failure in solar installations. A multiscale reliability model based on detailed molecular degradation reaction kinetics was previously published, connecting the encapsulant mechanical properties (elastic modulus, yield strength, and adhesion energy) to the degraded molecular structure and interfacial bond density to adjacent solar cell and glass substrates. The model, developed primarily for poly(ethylene-co-vinyl acetate) (EVA) encapsulants, remains to be experimentally validated. Determining the degradation and crosslinking kinetics of alternative encapsulants, such as polyolefin elastomer (POE) and EVA/POE/EVA composites (EPE), can further generalize the model. Importantly, the activation energy for crosslinking of fully cured PV encapsulant products from temperature or UV is presently unknown or unavailable. In this work, we subject EVA, POE, and EPE encapsulants to a set of accelerated aging conditions, varying the temperature, UV intensity, and relative humidity. We use DSC, FTIR, and Soxhlet extraction (gel content) to characterize the encapsulants' changing molecular structure. This allows for determination of the photochemical degradation and crosslinking kinetics of the encapsulants. Preliminary results show an increase in gel content (crosslinking) and a decrease in crystallinity of EVA, POE, and EPE encapsulants under hot-aerobic (90 deg C, 22% RH) and hot-anaerobic (90oC, sealed in N2 air) accelerated aging, even in the absence of UV and crosslinking initiating agents. For a least squares regression with an assumed first-order crosslinking kinetics, the crosslinking rate parameters were computed for the three encapsulants under hot-aerobic and hot-anaerobic aging conditions. FTIR analysis showed insignificant encapsulant degradation for hot-aerobic and hot-anaerobic aging, demonstrating the critical role of UV and moisture in accelerating degradation. Aging conditions with UV exposure and elevated humidity are presently in progress.

adhesion↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Phosphate anion-quaternary ammonium ion pair coordinated polymer membranes

Ion exchange membranes materials according to the present disclosure exhibit improved conductivity at low and intermediate relative humidity without sacrificing mechanical strength. Polymers are provided that include a backbone with one or more aryl groups, a halocarbyl group, and a halocarbyl side chain attached to the backbone, wherein the halocarbyl side chain includes a halide separated from the backbone by a hydrocarbyl chain, a hydrocarbyl ring, or combinations thereof. The halide is substituted with a tertiary amine and halide anions are then exchanged with hydroxide anions. The polymers are then contacted with phosphoric acid, which is deprotonated by the hydroxide ions, forming anions which enhance interactions with adjacent quaternary ammonium groups and induce excess phosphoric acid molecules to cluster around those quaternary ammonium groups. The membranes exhibit negligible dopant leaching even at high relative humidity.

Bae, Chulsung↗