Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Observations of comet Kohoutek (1973f)

The coma region Comet Kohoutek (1973f) was observed with a 40-mm proximity focused image intensifier tube and filters to isolate principal emissions. The low brightness of the comet limited the results, but it was possible to compare the intensity profiles of C2 and continuum in the coma. It appears that Comet Kohoutek was a typical comet in that it did not exhibit unusual coma structure similar to that of Comet Bennet. Photographs taken with the 42 cm Schmidt showed typical type 1, type, 2 and antitail morphology, with increased type 2 activity after perihelion passage. A technique for eliminating the type 2 (dust) component of the tail is given by means of photographic subtraction of blue and red sensitive layers of a color photograph.

Larson, S.↗

Balloon-borne ultraviolet stellar spectrometer: Acquisition, tracking and command systems

The NASA Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) which is carried to an altitude of 40 km by a 15 million cubic foot balloon for night-time observations of ultraviolet stellar spectra is discussed. The BUSS optical system, comprising an 0.40 m aperture Cassegrain telescope and an Ebert-Fastie spectrometer, points at various selected stars and focuses a portion of their spectra on the photocathode of an image dissector tube. The spectral region between 2,775 Angstroms and 2,825 Angstroms is sampled by the detector at 0.25 Angstroms increments using photon counting techniques. The pointing system for the payload uses a pair of orthogonal magnetometers which sense the earth's magnetic field for an aximuth reference, and a platform potentiometer for an elevation reference. This pointing system places the target star within the 3x1 degree field of view of an outer optical star tracker. The outer star tracker is then used to point the entire instrument to within one arc minute of the target star.

Gibson, W. C.↗

Modification, fabrication, testing and delivery of ITT model F4012 RP tube/coil assembly

Results of the improvement program for the ITT model F4012 RP image dissector tube and coil are presented. This program undertaken to improve the characteristics of this assembly to make it more accurate for the Large Space Telescope trackers' applications. Comparisons are given of the performance of the new components and the original design goals. Recommendations for further tests and/or design changes to further improve the F4012 tube/coil assembly performance are given.

Source record↗

Design constraints of the LST fine guidance sensor

The LST Fine Guidance Sensor design is shaped by the rate of occurrence of suitable guide stars, the competition for telescope focal plane space with the Science Instruments, and the sensitivity of candidate image motion sensors. The relationship between these parameters is presented, and sensitivity to faint stars is shown to be of prime importance. An interferometric technique of image motion sensing is shown to have improved sensitivity and, therefore, a reduced focal plane area requirement in comparison with other candidate techniques (image-splitting prism and image dissector tube techniques). Another design requirement is speed in acquiring the guide star in order to maximize the time available for science observations. The design constraints are shown parametrically, and modelling results are presented.

Wissinger, A. B.↗

Anamorphic lens for tracking system

Lens has 2:1 focal-length ratio, consists of three spherical and two cylindrical elements, and is 7.6 cm in length. When used in conjunction with image dissector tube, expected root-mean-square noise equivalent angle is approximately 8 arc seconds.

Burns, R. H.↗

Photography and photometry of the near infrared OH airglow

The instruments employed in the investigation were modified for aircraft use primarily by automating the repetitive measurements and incorporating image intensifier tubes to reduce exposure times. The instruments include a 35-mm camera, an absolutely calibrated photometer, and a 16-mm movie camera. The data obtained will be used in a study of the variation of parallax emission heights with geographical location, and the relationship of OH patch or stripe size to emission height.

Peterson, A. W.↗

Engineering design criteria for an image intensifier/image converter camera

The design, display, and evaluation of an image intensifier/image converter camera which can be utilized in various requirements of spaceshuttle experiments are described. An image intensifier tube was utilized in combination with two brassboards as power supply and used for evaluation of night photography in the field. Pictures were obtained showing field details which would have been undistinguishable to the naked eye or to an ordinary camera.

Sharpsteen, J. T.↗

System for producing chroma signals

A method for obtaining electronic chroma signals with a single scanning-type image device is described. A color multiplexed light signal is produced using an arrangement of dichroic filter stripes. In the particular system described, a two layer filter is used to color modulate external light which is then detected by an image pickup tube. The resulting time division multiplexed electronic signal from the pickup tube is converted by a decoder into a green color signal, and a single red-blue multiplexed signal, which is demultiplexed to produce red and blue color signals. The three primary color signals can be encoded as standard NTSC color signals.

Vorhaben, K. H.↗

Development of the EXITE detector - A new imaging detector for 20 - 300 keV astronomy

The development and testing of a detector to be used in the Energetic X-ray Imaging Telescope Experiment (EXITE) are reported. It consists of a 34 cm diameter NaI(Tl) crystal coupled directly to a single large image intensifier tube with associated silicon PIN diode readout. The measured spatial and energy resolutions at 122 keV are 6mm (FWHM) and 9 percent (FWHM), respectively. This energy resolution is about 50 percent better than that of any previously flown hard X-ray experiment. These resolutions decrease with the square root of the energy of the incident X-ray, indicating that they are determined by the number of photons emitted in the NaI(Tl) scintillator light flash.

Garcia, M. R.↗

The Multichannel Ocean Color Sensor (MOCS)

The MOCS is an imaging spectroradiometer with a sensitivity that matches the light upwelling from open bodies of water. Twenty contiguous spectral channels in the visible are recorded in a line scanning mode from an aircraft. The system also supports a thermal infrared radiometer and will accept input from a position location system. The sensor in the MOCS system is an image dissector tube. A spectral curvature algorithm was developed. No atmospheric correction to the data is needed for low flying aircraft gathering chlorophyll data using this algorithm. Although the MOCS is now about 15 years old, because its response has been so stable, its data recording system was upgraded to the system used by the Aircraft Oceanographic Lidar where possible. The MOCS has been a reliable instrument for recording ocean color from low flying aircraft. As NASA enters the next period of ocean color investigations from space, such a device can play an important role in calibration of the space instrument, as well as provide support for programs developing the next generation of spaceborne devices.

Oberholtzer, J. D.↗

Initial performance of the High Speed Photometer

The Hubble Space Telescope High Speed Photometer has four image dissector tubes, two with UV sensitive photocathodes, two sensitive to the near UV and to visual light, and a single red sensitive photomultiplier tube. The HSP is capable of photometric measurements from 1200 to 7500 A with time resolution of 11 microseconds and has no moving parts. An initial analysis of the on-orbit engineering performance of the HSP is presented with changes in operating procedures resulting from the primary mirror spherical aberration and experience gained during the verification period.

Richards, Evan↗

Preliminary Parallaxes of 40 L and T Dwarfs from the US Naval Observatory Infrared Astronometry Program

We present preliminary trigonometric parallaxes and proper motions for 22 L dwarfs and 18 T dwarfs measured using the ASTROCAM infrared imager on the US naval Observatory (USNO) 1.55 m Strand Astrometric Reflector. The results presented here are based on observations obtained between 2000 September and 2002 November; about half of the objects have an observational time baseline of t 1:3 yr and half t 2:0 yr. Despite these short time baselines, the astrometric quality is sufficient to produce significant new results, especially for the nearer T dwarfs. Seven objects are in common with the USNO optical CCD parallax program for quality control and seven in common with the European Southern Observatory 3.5 m New Technology Telescope parallax program. We compare astrometric quality with both of these programs. Relative to absolute parallax corrections are made by employing Two Micron All Sky Survey and/or Sloan Digital Sky Survey photometry for reference-frame stars. We combine USNO infrared and optical parallaxes with the best available California Institute of Technology (CIT) system photometry to determine MJ , MH, and MK values for 37 L dwarfs between spectral types L0 and L8 and 19 T dwarfs between spectral types T0.5 and T8 and present selected absolute magnitude versus spectral type and color diagrams, based on these results. Luminosities and temperatures are estimated for these objects. Of special interest are the distances of several objects that are at or near the L-T dwarf boundary so that this important transition can be better understood. The previously reported early to mid T dwarf luminosity excess is clearly confirmed and found to be present at J, H, and K. The large number of objects that populate this luminosity-excess region indicate that it cannot be due entirely to selection effects. The T dwarf sequence is extended to MJ 16:9 by 2MASS J041519 0935, which, at d 5:74 pc, is found to be the lluminous LOG (L=L )pa

L DWARFS↗

Space Shuttle Star Tracker Challenges

The space shuttle fleet of avionics was originally designed in the 1970's. Many of the subsystems have been upgraded and replaced, however some original hardware continues to fly. Not only fly, but has proven to be the best design available to perform its designated task. The shuttle star tracker system is currently flying as a mixture of old and new designs, each with a unique purpose to fill for the mission. Orbiter missions have tackled many varied missions in space over the years. As the orbiters began flying to the International Space Station (ISS), new challenges were discovered and overcome as new trusses and modules were added. For the star tracker subsystem, the growing ISS posed an unusual problem, bright light. With two star trackers on board, the 1970's vintage image dissector tube (IDT) star trackers track the ISS, while the new solid state design is used for dim star tracking. This presentation focuses on the challenges and solutions used to ensure star trackers can complete the shuttle missions successfully. Topics include KSC team and industry partner methods used to correct pressurized case failures and track system performance.

Herrera, Linda M.↗

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗

Robotic System Would Inspect Tubes And Fillets

Proposed robotic system inspects arrays of brazed tubes being fabricated for use in heat exchangers and similar objects. Arrays contain coolant tubes mounted in nozzle of main engine of Space Shuttle. Other versions used to inspect components of terrestrial heat exchangers for powerplants, vehicles, and refrigeration equipment. Inspection system provides for automated, complete, objective, and efficient inspection of arrays of coolant tubes. Computer executing image-processing algorithms extracts profiles of tubes and braze fillets and identifies flaws.

Gilbert, Jeffrey L.↗

Imaging Fluorescent Combustion Species in Gas Turbine Flame Tubes: On Complexities in Real Systems

Planar laser-induced fluorescence (PLIF) is used to visualize the flame structure via OH, NO, and fuel imaging in kerosene- burning gas turbine combustor flame tubes. When compared to simple gaseous hydrocarbon flames and hydrogen flames, flame tube testing complexities include spectral interferences from large fuel fragments, unknown turbulence interactions, high pressure operation, and the concomitant need for windows and remote operation. Complications of these and other factors as they apply to image analysis are considered. Because both OH and gas turbine engine fuels (commercial and military) can be excited and detected using OH transition lines, a narrowband and a broadband detection scheme are compared and the benefits and drawbacks of each method are examined.

Hicks, Y. R.↗

Atmospheric Emission Photometric Imaging on Spacelab (AEPI)

Two parallel detector systems are used for atmospheric emission photometric emission. The top system is a TV system using the image intensified S.E.C. tube as the detector. The bottom system, the photon counting array (P.C.A.), uses a microchannel plate intensified anode array tube and is equivalent to a 100 channel photomultiplier. For the television, the filters are selected by means of a filter wheel set. The field of view of the is interchangeable between 20 and 6 degrees, by means of a moveable prism. The quartz window mu channel plate intensifier is fiber optically coupled to a 40-25 demagnifying tube which is in turn coupled to the S.E.C. tube. The PCA channel has a fixed field of view of 4 deg and a remote control interchangeable photometric converter optics which converts the imaging array into a multichannel photometer. The mu channel plate array tube amplifies the photons into detectable counts for the PCA electronics. The entire system is pointed by a two axis gimbal. The flight equipment to be acquired consists of a gyro package and an interactive flight control unit panel. The gyro package is necessary because of the inadequate attitude reference supplied by the current Spacelab systems.

Mende, S. B.↗