Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS FOR MEASURING PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Cobra Fiber-Optic Positioner Upgrade

A prime focus spectrometer (PFS), along with corrective optics, will mount in place of the secondary mirror of the Subaru telescope on Mauna Kea, Hawaii. This will allow simultaneous observations of cosmologic targets. It will enable large-scale galactic archeology and dark energy surveys to help unlock the secrets of the universe. To perform these cosmologic surveys, an array of 2,400 optical fibers needs to be independently positioned within the 498-mm-diameter focal plane of the PFS instrument to collect light from galaxies and stars for spectrographic analyses. To allow for independent re-positioning of the fibers, a very small positioner (7.7 mm in diameter) is required. One hundred percent coverage of the focal plane is also required, so these small actuators need to cover a patrol region of 9.5 mm in diameter. To optimize the amount of light that can be collected, the fibers need to be placed within 5 micrometers of their intended target (either a star or galaxy). The Cobra Fiber Positioner was designed to meet the size and accuracy requirements stated above. Cobra is a two-degrees-of-freedom mechanism that can position an optical fiber in the focal plane of the PFS instrument to a precision of 5 micrometers. It is a theta-phi style positioner containing two rotary piezo tube motors with one offset from the other, which enables the optic fibers to be placed anywhere in a small circular patrol region. The patrol region of the actuator is such that the array of 2,400 positioners allows for full coverage of the instrument focal plane by overlapping the patrol areas. A second-generation Cobra positioner was designed based on lessons learned from the original prototype built in 2009. Improvements were made to the precision of the ceramic motor parts, and hard stops were redesigned to minimize friction and prevent jamming. These changes resulted in reducing the number of move iterations required to position the optical fiber within 5 micrometers of its target. At the time of this reporting, there are still many tests to be performed that will validate system level performance, but on an individual level, the Cobra positioner demonstrates excellent performance and will enable the PFS instrument to make unprecedented measurements of the universe. What is unique about the upgrades made to the Cobra positioner is the improved performance due to the design changes in the hard stops and the ceramic end caps of the motors. Other changes were made to reduce the unit cost of a Cobra positioner without affecting the performance, since thousands of these devices will have to be built for the PFS instrument.

Fisher, Charles D.↗

Autonomous Navigation of a Lunar Relay Using GNSS and Other Measurements

Many of the highest priority destinations at the Moon lack a continuous view of Earth, such as the lunar poles or lunar far side. Exploration of these sites will require spacecraft in cislunar space to relay communications and provide position, navigation, and timing (PNT) services. Accurate knowledge of relay position, velocity, and time is essential to these services. This paper describes a concept for a PNT Instrument being developed for the Lunar Communications Relay and Navigation Systems (LCRNS) Project. The instrument is intended as a payload that would enable autonomous, on-board, real-time navigation and timing using Global Navigation Satellite System (GNSS), optical navigation, and one-way measurements from Earth-based ground stations. Hardware-in-the-loop simulations using flight software are used to realistically characterize performance on hardware platforms with a path to flight. These results provide preliminary validation of the proposed PNT Instrument, demonstrate the benefits of augmenting GNSS with other measurements, and serve as an insightful reference for the design of future lunar missions, including those that will operate within the LunaNet framework of standards. This instrument concept relies on several technologies developed at NASA Goddard Space Flight Center (GSFC). For GNSS observables, the instrument relies on the high-altitude NavCube 3 mini (NC3m) GNSS receiver specifically designed for cislunar applications. The autoNGC system, which consists of flight software and a hardware platform, is responsible for fusing the observables using its extended Kalman filter, the Goddard Enhanced Onboard Navigation System (GEONS). Optical navigation observables are processed within autoNGC (“autonomous Navigation, Guidance, and Control”) using the Goddard Image Analysis & Navigation Tool (GIANT) which is also responsible for simulating high-fidelity images for test and analysis. In addition to describing the PNT Instrument and its components, the paper will present predicted performance based on simulation results. As a baseline, it will present GNSS-only hardware-in-the loop results using a NC3m test unit to process Spirent-simulated GPS signals in a potential lunar relay trajectory: a 12-hour elliptical frozen lunar orbit (ELFO). GEONS then processes the GPS pseudorange and time differenced carrier phase measurements to estimate and propagate the relay state (position, velocity, and time). These results extend previously published work that showed preliminary ELFO performance. Previous work has shown the importance of other measurement types, so additional simulations are performed which augment GNSS with ground station observables and several methods of optical navigation, including celestial navigation, limb-finding (e.g., observations of the lunar horizon), and terrain relative navigation (TRN). TRN involves correlating simulated predicted images of the lunar surface with actual imagery; misalignments of landmarks identified in each image are translated into relay state updates. TRN is valuable as a measurement of the relay’s state relative to the Moon, especially during GNSS outages or after maneuvers. One-way Pseudorange and Doppler measurements from Earth-based ground stations are also simulated. The full set of observables is processed using autoNGC. These simulations make use of autoNGC and NC3m test units, a lab atomic clock, and a pulse-per-second (PPS) generation and distribution system. This combination of subsystems, and the hardware platforms used in this analysis, represents a PNT Instrument that could be flown on a lunar relay. Results from the hardware-in-the-loop simulations presented in this paper provide a preliminary assessment of the achievable navigation performance of this instrument concept. PNT Instrument performance is compared to the GPS-only performance, and a discussion is provided on the apparent merits and challenges of each measurement type.

Ben Ashman↗

Foundations of measurement and instrumentation

The user of instrumentation has provided an understanding of the factors that influence instrument performance, selection, and application, and of the methods of interpreting and presenting the results of measurements. Such understanding is prerequisite to the successful attainment of the best compromise among reliability, accuracy, speed, cost, and importance of the measurement operation in achieving the ultimate goal of a project. Some subjects covered are dimensions; units; sources of measurement error; methods of describing and estimating accuracy; deduction and presentation of results through empirical equations, including the method of least squares; experimental and analytical methods of determining the static and dynamic behavior of instrumentation systems, including the use of analogs.

Warshawsky, Isidore↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

Preliminary measurements of very low dark currents in MLA/SWIR HgCdTe/DRO arrays

In infrared astronomy observations, one of the key detector performance parameters is the dark current which, together with the optics, establishes the fundamental limit of a space-based instrument. This technical note summarizes an effort to measure dark current performance of the MLA/Short Wave Infrared photovoltaic HgCdTe array (2.5 micron cutoff) at temperatures from 65 to 120 K. The preliminary results indicate that dark current decreased systematically to 100 K, then the value became measurement-limited at about 3.0 E-18 A/pixel, or 19 electrons/sec/pixel.

Yang, B. T.↗

Hypersonic aerodynamic/aerothermodynamic testing capabilities at Langley Research Center

Capabilities of the Langley Hypersonic Facilities Complex that consists of nine blowdown-to-vacuum wind tunnels are reviewed. These tunnels complement one another to provide ranges of Mach number from 6 to 20, unit Reynolds number from 0.03 to 40 million per ft, and normal shock density ratio from 2 to 12. Topics under consideration include the basic components of each facility, status, and upgrades recently performed; instrumentation and testing techniques routinely used to measure forces and moments, surface pressures, surface temperature-time histories, flow properties within the shock layer about the model via survey probes, and flow visualization; and data acquisition systems and upgrades performed via a NASA revitalization program.

Miller, C. G., III↗

Thematic Mapper Image Processing System - Geometric correction performance for Landsat-5

Geometric correction performance data are presented for the Landsat-5 Thematic Mapper and the Thematic Mapper Image Processing System. Temporal registration and geodetic rectification results are displayed in the form of 90 percent errors. Both error estimation and direct measurements demonstrate that the instrument and system meet performance requirements.

Brooks, J.↗

NCTM workshop splinter session, IR thermal measurement instruments

The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

Kaplan, Herbert↗

ASRDI oxygen technology survey. Volume 6: Flow measurement instrumentation

A summary is provided of information available on liquid and gaseous oxygen flowmetering including an evaluation of commercial meters. The instrument types, physical principles of measurement, and performance characteristics are described. Problems concerning flow measurements of less than plus or minus two percent uncertainty are reviewed. Recommendations concerning work on flow reference systems, the use of surrogate fluids, and standard tests for oxygen flow measurements are also presented.

Mann, D. B.↗

Comparative evaluation of twenty pilot workload assessment measure using a psychomotor task in a moving base aircraft simulator

A comparison of the sensitivity and intrusion of twenty pilot workload assessment techniques was conducted using a psychomotor loading task in a three degree of freedom moving base aircraft simulator. The twenty techniques included opinion measures, spare mental capacity measures, physiological measures, eye behavior measures, and primary task performance measures. The primary task was an instrument landing system (ILS) approach and landing. All measures were recorded between the outer marker and the middle marker on the approach. Three levels (low, medium, and high) of psychomotor load were obtained by the combined manipulation of windgust disturbance level and simulated aircraft pitch stability. Six instrument rated pilots participated in four seasons lasting approximately three hours each.

Connor, S. A.↗

The flight test of a grazing incidence relay optics telescope for solar X-ray astronomy utilizing a thinned, back-illuminated CCD detector

The new AS&E Ultrahigh Resolution Soft X-ray Solar Research Rocket Payload has been successfully flown twice on Black Brant IX Sounding Rockets from White Sands Missile Range. These flights, conducted on 15 August 1987 and 11 December 1987, provided the first test of the new payload which consists of 3.8X magnifying hyperboloid-hyperboloid grazing incidence relay optic used in conjunction with an existing Wolter-I primary mirror. An RCA SID 500 series CCD detector was utilized in a thinned, back-illuminated configuration for recording the images. The 5.4 m effective focal length of the compound optics system resulted in a plate scale of 1 arc second per pixel which is comparable to the inherent resolution of the primary mirror. These flights represent the first use in X-ray astronomy of either of these two new technologies. These observations are presented with comparison to laboratory measurements and theoretical expectations of the instrument performance.

Moses, J. Daniel↗

Optical properties of KD*P modulators

Longitudinal KD*P modulators are used in ground-based solar magnetographs to eliminate seeing effects. Although the modulators can be used as variable retarders, the optical properties when zero voltage is applied influences the performance on instruments requiring very accurate polarization measurements. Measurements at the Marshall Space Flight Center are discussed in terms of the optical properties of KD*P modulators when zero voltage is applied. The measurements can be used to predict the modulation characteristics of the devices and to determine the polarization accuracy that can be expected from the vector magnetograph.

West, E. A.↗

Specification list and function structure for a full-body dynamometer to be used aboard Space Station Freedom

NASA has a need for a machine which can be used as an exercise device and as an instrument to measure an astronaut's muscle performance. The purpose of the exercise device is to work various muscle groups of the astronaut to prevent muscle atrophy, the loss of muscle strength and mass from prolonged exposure to a microgravity environment. The measurement part of the machine will be used to collect data on the strength and power of the astronaut's muscle groups to be used in studies examining the effects of prolonged space inhabitation. The principle device used in this machine to both exercise and measure muscle performance is the dynamometer. The dynamometer converts electrical energy to mechanical energy and mechanical energy to electrical energy or signals. The task of the designer will be to incorporate a dynamometer into a device which can meet all of the needs discussed above. This memorandum has two sections which clarify the design task of producing a full-body dynamometer. The first section is a specification list. The specification list provides the requirements that the designer must meet in his/her design. The second part is a function structure. The function structure shows graphically the flow of material, energy, and information through the machine. These two items will be used by the designer in the design process for the full-body dynamometer.

Mcmahan, Robert↗

Space-Based Remote Imaging Spectroscopy of the Aliso Canyon CH4 Superemitter

The Aliso Canyon gas storage facility near Porter Ranch, California, produced a large accidental CH4 release from October 2015 to February 2016. The Hyperion imaging spectrometer on board the EO-1 satellite successfully detected this event, achieving the first orbital attribution of CH4 to a single anthropogenic superemitter. Hyperion measured shortwave infrared signatures of CH4 near 2.3 microns at 0.01 micron spectral resolution and 30 meter spatial resolution. It detected the plume on three overpasses, mapping its magnitude and morphology. These orbital observations were consistent with measurements by airborne instruments. We evaluate Hyperion instrument performance, draw implications for future orbital instruments, and extrapolate the potential for a global survey of CH4 superemitters.

Thompson, D. R.↗

Snow and Water Imaging Spectrometer: Final Instrument Characterization

The Snow and Water Imaging Spectrometer (SWIS) is a science-grade imaging spectrometer and telescope system suitable for CubeSat applications, spanning a 350-1700 nm spectral range with 5.7 nm sampling, a 10 degree field of view and 0.3 mrad spatial resolution. The system operates at F/1.8, providing high throughput for low-reflectivity water surfaces, while avoiding saturation over bright snow or clouds. The SWIS design utilizes heritage from previously demonstrated instruments on airborne platforms, while advancing the state of the art in compact sensors of this kind in terms of size and spectral coverage. Through frequent repeat observations from space at a moderate spatial resolution, SWIS can address key science questions concerning aquatic and terrestrial ecosystem changes, cryosphere warming and melt behavior, cloud and atmospheric science, and potential impacts of climate change and human activities on the environment. We review the optical design and innovations and key technologies developed for this instrument, as well as its measured optical performance. We discuss the radiometric calibration characterization, including detector linearity, flat field correction, and SNR. Finally, we discuss stray light modeling and the development of a focused ghost removal algorithm, which is tested and supported by laboratory results.

Bellardo, John↗

Double-Pulse Two-Micron IPDA Lidar Simulation for Airborne Carbon Dioxide Measurements

An advanced double-pulsed 2-micron integrated path differential absorption lidar has been developed at NASA Langley Research Center for measuring atmospheric carbon dioxide. The instrument utilizes a state-of-the-art 2-micron laser transmitter with tunable on-line wavelength and advanced receiver. Instrument modeling and airborne simulations are presented in this paper. Focusing on random errors, results demonstrate instrument capabilities of performing precise carbon dioxide differential optical depth measurement with less than 3% random error for single-shot operation from up to 11 km altitude. This study is useful for defining CO2 measurement weighting, instrument setting, validation and sensitivity trade-offs.

Refaat, Tamer F.↗

Flight motor set 360L009 (STS-36). Volume 1: System overview

Flight Motor Set 360L009, as part of NASA Space Shuttle Mission STS-36, a Department of Defence mission, was launched after two launch attempts. One launch was scrubbed following the failure of a ground-based Range Safety computer and one was scrubbed due to cloud cover at the return to launch landing site. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns from either motor. All ballistic and mass property parameters that could be assessed, closely matched the predicted values and were well within the required contract item specification levels. All field joint heaters and igniter joint heaters performed without anomalies. Evaluation of the ground environment instrumentation measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria violations occurred. Postflight inspection again verified nominal performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated that both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints. Recommendations were made concerning improved thermal modeling and measurements. The rationale for these recommendations and complete result details are presented.

Garecht, Diane M.↗

Flight Motor Set 360T010 (STS-31R). Volume 1: System Overview

Flight motor set 360T010 was launched at approximately 7:34 a.m. CST (090:114:12:33:50.990 GMT) on 24 Apr. 1990 after one launch attempt (attempt on 10 Apr. 1990 was scrubbed following an indication of erratic operation of the Orbiter No. 1 Auciliary Power Unit No. 1). There were no problems with the solid rocket motor launches, overall motor performance was excellent. There were no debris concerns from either motor. Nearly all ballistic contract end item specification parameters were verified with the exception of ignition interval, pressure rise rate, and ignition time thrust imbalance. These could not be verified due to elimination of developmental flight instrumentation on 360L004 (STS-30R) and subsequent, but low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters that could be assessed closely matched the predicted values and were well within the required contract end item specification levels. All field joint heaters and igniter joint heaters performed without anomalies. Evaluation of the ground environment instrumentation measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria violations occurred. Postflight inspection again verified nominal performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗