Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analysis of Radiation Effects in Silicon using Kinetic Monte Carlo Methods

The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. Neutron irradiation can instigate the formation of quasi-stable defect structures, thereby introducing new energy levels into the bandgap that alter carrier lifetimes and give rise to such phenomena as gain degradation in bipolar junction transistors. Normally, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. A kinetic Monte Carlo (KMC) code has been developed to model both thermal and carrier injection annealing of initial defect structures in semiconductor materials. The code is employed to investigate annealing in electron-irradiated, p-type silicon as well as the recovery of base current in silicon transistors bombarded with neutrons at the Los Alamos Neutron Science Center (LANSCE) “Blue Room” facility. Our results reveal that KMC calculations agree well with these experiments once adjustments are made, within the appropriate uncertainty bounds, to some of the sensitive defect parameters.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multicenter Phase II Study of Intraoperative Radiotherapy of Early Breast Cancer: Ipsilateral Tumor Recurrence

Background: We performed a multicenter phase II study on the efficacy and safety of intraoperative radiotherapy (IORT) as partial breast irradiation using multiple devices. Methods: The primary endpoint was ipsilateral breast tumor recurrence (IBTR). Key inclusion criteria were T < 2.5 cm, age > 50 years, surgical margin > 1 cm, intraoperative pathologically free margins, and sentinel node negative. After resection of the tumor, radiation at 21 Gy was delivered directly to the mammary gland employing an electron linear accelerator in the operating room, otherwise the patient was transported from the surgical suite to the radiation room. Results: Overall, 142 patients were enrolled in this study and 129 underwent IORT. Stage 0: n = 4 (3.1%); stage I: n = 98 (76.0%); and stage IIA: n = 27 (20.9%). Luminal type: n = 116 (89.9%); triple-negative: n = 9 (7.0%); and human epidermal growth factor receptor 2: n = 4 (3.1%). Median follow-up time was 59.5 months (range 27.5–99.0), and the rate of IBTR was 3.1% (95% confidence interval 0.9–7.8). The toxicities included fibrosis in deep-connective tissue: grade 1, 78.1%; wound infection: grade 3, 1.6% and grade 2, 1.6%; and soft tissue necrosis: grade 3, 0.8% and grade 2, 0.8%. Recurrence in the breast occurred in four cases; the site of recurrence was just under the skin near the primary tumor site, with similar histology and subtype. Conclusions: In this multicenter phase II study, the rate of IBTR was low and IORT at 21 Gy was feasible in properly selected patients. It is important to use a careful surgical technique to reduce local recurrence because the skin is not included in the radiation field of IORT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact Models for Defect Diffusivity in Semiconductor Alloys.

Predicting transient effects caused by short - pulse neutron irradiation of electronic devices is an important part of Sandia's mission. For example , predicting the diffusion of radiation - induced point defects is needed with in Sandia's Qualification Alternative to the Sandia Pulsed Reactor (QASPR) pro gram since defect diffusion mediates transient gain recovery in QASPR electronic devices. Recently, the semiconductors used to fabricate radiation - hard electronic devices have begun to shift from silicon to III - V compounds such as GaAs, InAs , GaP and InP . An advantage of this shift is that it allows engineers to optimize the radiation hardness of electronic devices by using alloy s such as InGaAs and InGaP . However, the computer codes currently being used to simulate transient radiation effects in QASP R devices will need to be modified since they presume that defect properties (charge states, energy levels, and diffusivities) in these alloys do not change with time. This is not realistic since the energy and properties of a defect depend on the types of atoms near it and , therefore, on its location in the alloy. In particular, radiation - induced defects are created at nearly random locations in an alloy and the distribution of their local environments - and thus their energies and properties - evolves with time as the defects diffuse through the alloy . To incorporate these consequential effects into computer codes used to simulate transient radiation effects, we have developed procedures to accurately compute the time dependence of defect energies and properties and then formulate them within compact models that can be employed in these computer codes. In this document, we demonstrate these procedures for the case of the highly mobile P interstitial (I P ) in an InGaP alloy. Further dissemination only as authorized to U.S. Government agencies and their contractors; other requests shall be approved by the originating facility or higher DOE programmatic authority.

36 MATERIALS SCIENCE↗

LDRD Report : Analysis of Defect Clustering in Semiconductors using Kinetic Monte Carlo Methods

The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. Neutron irradiation can instigate the formation of quasi-stable defect structures, thereby introducing new energy levels into the bandgap that alter carrier lifetimes and give rise to such phenomena as gain degradation in bipolar junction transistors. Typically, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. A kinetic Monte Carlo (KMC) code has been developed to model both thermal and carrier injection annealing of initial defect structures in semiconductor materials. Following the development of a set of verification tests, the code is employed to investigate annealing in electron-irradiated, p-type silicon as well as the recovery of base current in silicon transistors bombarded with neutrons at the Los Alamos LANSCE "Blue Room" facility. The results reveal that KMC calculations agree well with experiment once adjustments are made to significant defect parameters within the appropriate uncertainty bounds.

36 MATERIALS SCIENCE↗

Memorandum of Understanding for the 2007 Meson Test Beam Program: Tests of LHCb Silicon Detectors

This Memorandum of Understanding applies to the use of the FNAL Meson Test Beam Facility to study the performance of several LHCb silicon vertex detectors. The tests will be carried out as a collaborative effort of CERN, Glasgow, Liverpool, and Syracuse Universities. The Vertex Locator (VELO) of the LHCb detector uses short silicon strips in a unique geometry that features strips at constant radial distance from the beam line and strips at almost constant azimuthal angle. The Silicon detectors in use at LHCb are implemented with n strips on n substrates. Prototype replacement sensors, however, have been produced using n strips on p substrates. The new processing scheme offers the prospect of producing significantly lower cost detectors for future projects and possibly better performance especially of irradiated sensors. The experimenters wish to compare the performance of the n-on-n and n-on-p detectors for irradiated and non-irradiated sensors. To do so, the experimenters plan to use the pixel telescope being constructed in the MTest facility. In particular, the experimenters are planning to study the efficiency of the irradiated and unirradiated devices and the spatial resolution as a function of the track incident angle. They vary over the sensor area due to the unusual geometry. The experimenters will also change the incident angle of the beam by moving the sensors, to investigate how the resolution varies with angle. Besides VELO sensors, some n-on-p sensors are available from the RD50 collaboration at CERN. Many physicists participating in this test beam are members ofRD50. This memorandum is intended solely for the purpose of providing a work allocation for Fermi National Accelerator Laboratory and the participating universities and institutions. It reflects an arrangement that is currently satisfactory to the parties involved. It is recognized, however, that changing circumstances of the evolving research program may necessitate revisions. The parties agree to negotiate amendments to this memorandum to reflect such revisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Memorandum of Understanding for the 2009 to 2012 Meson Test Beam Program T-992: Tests of radiation-hard sensors for the SLHC

This memorandum is intended solely for the purpose of providing a work allocation for Fermi National Accelerator Laboratory and the participating universities and institutions. It reflects an arrangement that is currently satisfactory to the parties involved. It is recognized, however, that changing circumstances of the evolving research program may necessitate revisions. The parties agree to negotiate amendments to this memorandum to reflect such revisions. This Memorandum of Understanding applies to the use of the FERMILAB Meson Test Beam Facility to study the performance of various sensors that are radiation hard and viable candidates for use in the innermost vertex detector for the SLHC environment. The tests will be carried out as a collaborative effort of Fermilab, and Colorado, Milano, Ohio State, Princeton, Purdue, Rutgers, Syracuse, and UCLA Universities. At the SLHC, after 2500 pb -1 of data, the expected maximum fluence for the pixel region (<20 cm) will be 2.5 x 10 16 cm -2 . To cope with this unprecedented radiation environment, there have been quite a few collaborations being formed at CERN to find possible solutions for vertex and tracking detectors at the SLHC. These include the RD42, RD49, and RD50 collaborations. A variety of solutions have been pursued. These include diamond sensors, 3D sensors, MCZ planar silicon detectors made from MCZ wafers, epitaxial, p-type silicon wafers and thin silicon detectors. The experimenters wish to compare the performance of this wide variety of detectors in a test beam before and after irradiation. To do so, the experimenters plan to use the CMS pixel-based telescope currently being commissioned and constructed for the MTest facility. In particular, the experimenters are planning to study the charge collection efficiency of the irradiated and unirradiated devices and the spatial resolution as a function of the track incident angle. The experimenters will change the incident angle of the beam by moving the sensors, to investigate how the resolution varies with angle. Many physicists participating in this beam test are members of the RD42 and/or RD50 collaborations.

43 PARTICLE ACCELERATORS↗

Real-time series resistance monitoring in photovoltaic systems

A device includes at least one processor configured to determine a target irradiance value based on an operating current value of a photovoltaic (PV) device, a short-circuit current value of the PV device, and an operating irradiance value of the PV device. The at least one processor is also configured to determine an open-circuit voltage value of the PV device at the target irradiance value, determine a series resistance value of the PV device based on an operating voltage value of the PV device, the operating current value, and the open-circuit voltage value at the target irradiance value, and execute at least one programmatic action based on the series resistance value.

14 SOLAR ENERGY↗

Electron-Beam-Related Studies of Halide Perovskites: Challenges and Opportunities

Electron beam microscopy and related characterization techniques play an important role in revealing the microstructural, morphological, physical, and chemical information of halide perovskites and their impact on associated optoelectronic devices. However, electron beam irradiation usually causes damage to these beam-sensitive materials, negatively impacting their device performance, and complicating this interpretation. Here, the electron microscopy and spectroscopy techniques are reviewed that are crucial for the understanding of the crystallization and microstructure of halide perovskites. In addition, special attention is paid to assessing and mitigating the electron beam-induced damage caused by these techniques. Since the halide perovskites are fragile, a protocol involving delicate control of both electron beam dose and dose rate, coupled with careful data analysis, is key to enable the acquisition of reliable structural and compositional information such as atomic-resolution images, chemical elemental mapping and electron diffraction patterns. Limiting the electron beam dose is critical parameter enabling the characterization of various halide perovskites. Novel methods to unveil the mechanisms of device operation, including charge carrier generation, diffusion, and extraction are presented in scanning electron microscopy studies combined with electron-beam-induced current and cathodoluminescence mapping. Future opportunities for electron-beam-related characterizations of halide perovskites are also discussed.

36 MATERIALS SCIENCE↗

Electromagnetic Radiation Effects on MgO-Based Magnetic Tunnel Junctions: A Review

Magnetic tunnel junctions (MTJs) have been widely utilized in sensitive sensors, magnetic memory, and logic gates due to their tunneling magnetoresistance. Moreover, these MTJ devices have promising potential for renewable energy generation and storage. Compared with Si-based devices, MTJs are more tolerant to electromagnetic radiation. In this review, we summarize the functionalities of MgO-based MTJ devices under different electromagnetic irradiation environments, with a focus on gamma-ray radiation. We explore the effects of these radiation exposures on the MgO tunnel barriers, magnetic layers, and interfaces to understand the origin of their tolerance. This review enhances our knowledge of the radiation tolerance of MgO-based MTJs, improves the design of these MgO-based MTJ devices with better tolerances, and provides information to minimize the risks of irradiation under various irradiation environments. This review starts with an introduction to MTJs and irradiation backgrounds, followed by the fundamental properties of MTJ materials, such as the MgO barrier and magnetic layers. Then, we review and discuss the MTJ materials and devices’ radiation tolerances under different irradiation environments, including high-energy cosmic radiation, gamma-ray radiation, and lower-energy electromagnetic radiation (X-ray, UV–vis, infrared, microwave, and radiofrequency electromagnetic radiation). In conclusion, we summarize the radiation effects based on the published literature, which might benefit material design and protection.

42 ENGINEERING↗

Role of belly board device in the age of intensity modulated radiotherapy for pelvic irradiation

Small bowel dose often represents a limiting factor for radiation treatment of pelvic malignancies. To reduce small bowel toxicity, a belly board device (BBD) with a prone position is often recommended. Intensity modulated radiotherapy (IMRT) could reduce dose to small bowel based on the desired dose-volume constraints. We investigated the efficacy of BBD in conjunction with IMRT. A total of 11 consecutive patients with the diagnosis of rectal cancer, who were candidates for definitive therapy, were selected. Patients were immobilized with BBD in prone position for simulation and treatment. Supine position computed tomography (CT) data were either acquired at the same time or during a diagnostic scan, and if existed was used. Target volumes (TV) as well as organs at risk (OAR) were delineated in both studies. Three-dimensional conformal treatment (3DCRT) and IMRT plans were made for both scans. Thus for each patient, 4 plans were generated. Statistical analysis was conducted for maximum, minimum, and mean dose to each structure. When comparing the normalized mean Gross TV dose for the different plans, there was no statistical difference found between the planning types. There was a significant difference in small bowel sparing when using prone position on BBD comparing 3DCRT and IMRT plans, favoring IMRT with a 29.6% reduction in dose (p = 0.007). There was also a statistically significant difference in small bowel sparing when comparing supine position IMRT to prone-BBD IMRT favoring prone-BBD IMRT with a reduction of 30.3% (p = 0.002). For rectal cancer when small bowel could be a limiting factor, prone position using BBD along with IMRT provides the best sparing. We conclude that whenever a dose escalation in rectal cancer is desired where small bowel could be limiting factor, IMRT in conjunction with BBD should be selected.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of New Type-B Containers and the 'Alternative Approach' Disposal of High-Activity Sealed Sources - 17385

The DOE/NNSA Office of Radiological Security (ORS) is undertaking two projects to enable the recovery and disposal of high-activity sealed sources. First, ORS has completed the development, certification, and fabrication of a new Type B package to support the recovery and transportation of high-activity sources commonly used in irradiators and cancer treatment devices. A second design is currently undergoing certification. The new containers will enable DOE/NNSA shipment of nearly 100 percent of all commercially used devices containing Cs-137 and Co-60, which are particularly significant from a National security, public health, and safety standpoint. Second, ORS and the Conference of Radiation Control Program Directors (CRCPD) Source Collection and Threat Reduction (SCATR) are piloting the commercial disposal of a high-activity device under the NRC's revised guidance on concentration averaging and encapsulation. The Cs-137 blood irradiator is being proposed for disposal at the U.S. Ecology facility in Richland, WA. The project is intended to serve as a model for commercial disposal of similar Class C sources that for decades have been without a commercial disposal pathway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electroforming-Free TaOx Memristors using Focused Ion Beam Irradiations

In this study, we demonstrate creation of electroforming-free TaOx memristive devices using focused ion beam irradiations to locally define conductive filaments in TaOx films. Electrical characterization shows that these irradiations directly create fully functional memristors without the need for electroforming. Finally, ion beam forming of conductive filaments combined with state-of-the-art nano-patterning presents a CMOS compatible approach to wafer level fabrication of fully formed and operational memristors.

36 MATERIALS SCIENCE↗

Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operando Temperature Measurements of Photovoltaic Laser Power Converter Devices Under Continuous High-Intensity Illumination

Photovoltaic devices that operate under extremely high irradiances, such as laser power converters (LPCs), may also operate at elevated temperatures, even under active cooling, as the result of large temperature gradients. We demonstrate the operation of GaAs LPC devices under orders of magnitude of irradiances up to 150 W/cm 2 in a monochromatic laser simulator with an active cooling stage. The steady-state open-circuit voltage (V OC ) as a function of irradiance is known to droop at high irradiance as the result of junction heating, but the junction temperature can be difficult to measure by conventional methods. Fast, transient V OC measurements under these extreme operating conditions are used here to determine the junction temperature. Empirical V OC temperature coefficients of the devices at each irradiance of interest are determined and used as an integral part of this technique. We show that the thermal design of different LPC devices strongly affects the operating temperature of the junctions. Knowledge of the operating temperature can be a strong tool for understanding the nature of loss mechanisms and improving the design for the operation of photovoltaic LPCs at high irradiances. Furthermore, this technique can be used for laboratory devices during initial design as well as to characterize mass-produced and packaged devices for quality control.

14 SOLAR ENERGY↗

Low cost and facile fabrication of broadband laser power meter based on reduced graphene oxide film

Highlights: • The reduced graphene oxide film is used to fabricate the low cost laser powermeter. • The photoresponse of the device is explored in the visible to near-infrared range. • The photoresponse of the device is linearly related to the irradiated laser power. • The photoelectric current of the device does not depend on the laser spot size. - Abstract: Here, we have demonstrated a new type of broadband reduced graphene oxide-based laser power meter in simple and low cost method. The broadband photosensitivity of the device is confirmed by photocurrent measurements at different incident laser wavelengths of 405, 532, 635 and 808 nm. It is shown that its photocurrent increases linearly with increasing the power of the laser beam. Also, it is observed that the photocurrent behavior of the device does not depend upon the size of the laser spot. It should be noted that the reduced graphene oxide power meter is the thermal detection device. Therefore, the response of the sample in the vacuum is greatly enhanced in compared to the environmental air. Cooling system can also decrease the time required for the establishment of thermal equilibrium and thus reduce the response time of the power meter. These results open up exciting opportunities for developing broadband photodetectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resilience of High-Efficiency CdSeTe:As and CdSeTe:Cu Solar Cells to Proton Irradiation

Power generation in space is currently dominated by expensive III-V multi-junction photovoltaic (PV) devices and cheap crystalline silicon (c-Si) PV devices. Both of these technologies degrade rapidly in proton-radiation-rich space environments, such as the Van Allen belt. The present study of cadmium selenide telluride- (CdSeTe-) based PV devices exposed to 150-to-1500 keV proton irradiation with fluences up to 9 x 1013 cm-2 reveal a more radiation-hard alternative to III-V and c-Si PV technologies. We report on measurement and analysis of current density vs voltage (JV), external quantum efficiency (EQE), external radiative efficiency, and capacitance vs voltage (CV) characteristics. JV characteristics of As-doped CdSeTe devices show 80% remaining power conversion efficiency (PCE) relative to unexposed controls when exposed to 650 keV protons at a fluence of 1012 cm-2. Under these same irradiation conditions, Cu-doped CdSeTe devices demonstrate an even better 95% PCE retention compared with unirradiated control devices. Evidence of radiation-induced absorber p-type doping compensation is observed in the glass-side EQE at 0 V and CV characteristics of most of the irradiated CdSeTe:As devices, but clear compensation is evident only for the most heavily irradiated CdSeTe:Cu devices. Elevated blue-green photocurrent in the film-side 0 V EQE suggests a buried junction in the most heavily irradiated CdSeTe:As devices. Although CdSeTe:Cu devices are the more resilient of the CdSeTe structures, both CdSeTe-based technologies are radiation-hard when compared to c-Si and III-V multi-junction PV.

14 SOLAR ENERGY↗