Search NASA⌕ Search

SEARCH · Search NASA

Results for “IT energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Enhancing Worker Safety During Off-Site Construction of Energy-Efficient, Low-Carbon Exterior Envelope

The construction industry is not doing enough to embrace off-site modular construction. It is a missed opportunity for optimized energy efficiency because prefabricated exterior wall envelopes are lower in cost and faster and easier to install. Factory off-site construction offers improved safety for construction workers because work is done in a controlled environment, but lack of intent, understanding, and data is also a missed opportunity for enhancing worker safety. This research looks specifically at the prefabricated wall exterior envelope in the context of safety. The research question is "off-site factories build with ease of energy efficiency and lowered carbon emissions, but is the process safer?" This research was funded by NREL Student Training in Applied Research (STAR) program, University Partnerships Program, and Wells Fargo Bank. Key finding is that modular and prefabricated construction are perceived to be safer, but the accident rates are much higher than in the general construction and manufacturing industries. Proposed solutions to decrease accidents in off-site prefabricated construction includes safety training for workers, provide movable kiosks with PPE at workstations, ensure tools are well-maintained and place safety posters in visible locations. Future work includes improving worker safety to increase worker productivity, perform pilot demonstration, work with factory designers for new modular layout for worker safety, i.e., easy access to PPE kiosks, and work closely with OSHA so that they take notice of this safety niche.

drywall↗

Editors’ Choice—Molten Salt Electrolysis in Chloride Melts for Energy-Efficient Iron Metal Production

This study explores chloride molten salt electrolysis (CMSE) as a promising route for energy-efficient iron metal (Fe) production. Moderate temperature (500 °C) LiCl-KCl molten salts offer excellent thermodynamic stability, high ionic conductivity and diffusivity, and high solubility for FeCl 3 , thereby enabling efficient Fe metal extraction at high electrowinning rates. Here, we demonstrate the two essential steps for converting taconite ore into Fe metal. First, Fe 2 O 3 from taconite pellets was selectively leached in HCl yielding a high-purity FeCl 3 aqueous solution, while the gangue components settled at the bottom. Then, anhydrous FeCl 3 was electrolyzed in a LiCl-KCl eutectic molten salt at 500 °C at high current density (1 A cm −2 ) and at high Coulombic efficiency (>85%). Analysis of the electrowon Fe deposits revealed dendritic structures with purity of >99 wt%, which could be further improved to nearly 100 wt% through arc re-melting. CMSE offers low specific energy consumption (3.7 kWhr kg −1 ), competitive with H 2 -DRI and other electrolytic approaches being pursued globally. Our findings underscore the potential of CMSE as an energy-efficient route for electrosynthesis of Fe metal.

36 MATERIALS SCIENCE↗

Household Energy Efficiency Analysis in San Jose, California

Many households in the City of San Jose, California, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for 83,000 housing units in low-to-moderate-income census tracts experiencing disproportionately high energy burden in San Jose. The results in this fact sheet only pertain to the housing units included in the analysis.

Communities LEAP↗

Akiachak Energy Efficiency Retrofit Project (Final Technical Report)

The Akiachak Native Community (ANC), a federally recognized Yup'ik Tribe, undertook this energy efficiency initiative to enhance energy performance in key community buildings, including the Tribal IRA Office, Laundry, Police Station, Clinic, and Daycare. Through energy audits and upgrades, the project focused on high-impact improvements like air sealing, LED lighting, and programmable thermostats, primarily in the Tribal Office due to funding constraints. The initiative aims to reduce energy waste, lower heating and electricity costs, and improve facility comfort and longevity. The project aims to generate long-term savings for further improvements by decreasing reliance on imported fuel oil. This initiative aligns with the Tribe's vision for responsible energy use, addressing the challenges of high fuel prices in a remote community, and serves as a model for similar efforts in Akiachak and other Alaska Native villages pursuing energy self-reliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Household Energy Efficiency Analysis for the Hill District, Pennsylvania: Version 2

Many households in the Hill District, Pennsylvania, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for the Hill District.

Communities LEAP↗

Household Energy Efficiency Analysis for the Hill District, Pennsylvania: Version 1

Many households in the Hill District, Pennsylvania, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for the Hill District.

Communities LEAP↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Future of Energy Efficiency in Buildings: Drivers and Market Expectations [Slides]

This slide-deck report identifies drivers of energy efficiency in buildings over the next 10 years, for all fuels. The report also provides insights on what the future of efficiency may look like in that time period and considers other distributed energy resources, as well as decarbonization and demand flexibility, to the extent they are intertwined with efficiency activities. Understanding market drivers and possible future market attributes for energy efficiency can help policy makers, regulators and industry make informed decisions—for example, how best to design policies and investments to support desired outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High–Performance NiCo 2 O 4 /Graphene Quantum Dots for Asymmetric and Symmetric Supercapacitors with Enhanced Energy Efficiency

For the sustainable growth of future generations, energy storage technologies like supercapacitors and batteries are becoming more and more common. However, reliable and high-performance materials’ design and development is the key for the widespread adoption of batteries and supercapacitors. Quantum dots with fascinating and unusual properties are expected to revolutionize future technologies. However, while the recent discovery of quantum dots honored with a Nobel prize in Chemistry, their benefits for the tenacious problem of energy are not realized yet. In this context, herein, chemical-composition tuning enabled exceptional performance of NiCo 2 O 4 (NCO)/graphene quantum dots (GQDs) is reported, which outperform the existing similar materials, in supercapacitors. A comprehensive study is performed on the synthesis, characterization, and electrochemical performance evaluation of highly functional NCO/GQDs in supercapacitors delivering enhanced energy efficiency. The high-performance, functional NCO/GQDs electrode materials are synthesized by the incorporation of GQDs into NCO. The effect of variable amount of GQDs on the energy performance characteristics of NCO/GQDs in supercapacitors is studied systematically. In-depth structural and chemical bonding analyses using X-ray diffraction (XRD) and Raman spectroscopic studies indicate that all the NCO/GQDs composites crystallize in the spinel cubic phase of NiCo 2 O 4 while graphene integration evident in all the NCO/GQDs. The scanning electron microscopy imaging analysis reveals homogeneously distributed spherical particles with a size distribution of 5–9 nm validating the formation of QDs. The high-resolution transmission electron microscopy analyses reveal that the NCOQDs are anchored on graphene sheets, which provide a high surface area of 42.27 m 2 g –1 and high mesoporosity for the composition of NCO/GQDs-10%. In addition to establishing reliable electrical connection to graphene sheets, the NCOQDs provide reliable 3D-conductive channels for rapid transport throughout the electrode as well as synergistic effects. Chemical-composition tuning, and optimization yields NCO/GQDs-10% to deliver the best specific capacitance of 3940 Fg –1 at 0.5 Ag –1 , where the electrodes retain ≈98% capacitance after 5000 cycles. The NCO/GQD-10%//AC asymmetric supercapacitor device demonstrates outstanding energy density and power density values of 118.04 Wh kg –1 and 798.76 W kg –1 , respectively. The NCO/GQDs-10%//NCO/GQDs-10% symmetric supercapacitor device delivers excellent energy and power density of 24.30 Wh kg –1 and 500 W kg –1 , respectively. These results demonstrate and conclude that NCO/GQDs are exceptional and prospective candidates for developing next-generation high-performance and sustainable energy storage devices.

25 ENERGY STORAGE↗

Integrating Health and Energy Efficiency in Healthcare Facilities

In this report, PNNL presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. This report includes a review of building standards and certification systems for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency. The healthcare industry includes a wide variety of services and thus facility types. This case study focuses primarily on inpatient facilities, such as hospitals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient and Water-Saving Sorbent Regeneration at Near Room Temperature for Direct Air Capture

Here this study reports energy-efficient and water-saving microwave-accelerated regeneration of sorbent (MARS) for dilute carbon capture from the ambient air. The experimental studies indicated that the CO 2 desorption rate from the chemisorbents increased with microwave output under near-isothermal conditions at near room temperature. The reduced activation energy of MARS, i.e., 20–28 kJ/mol, indicated enhanced CO 2 desorption kinetics by microwave-induced rotational–vibrational (rovibrational) coupling transitions, primarily due to the highly polarized feature of the carbamate (CO 2 -PEI). The instant and selective delivery of microwave energy to the targeted polarized C–N bonds at room temperature is particularly advantageous for energy-efficient direct air capture. The experimental results also demonstrated a good working capacity of 0.6–1.4 mmol of CO 2 /g and a promising rapid MARS-DAC process with microwave swing. As it does not require steam regeneration and heat exchanger, a simple MARS process is attractive for CO 2 capture in water-stressed regions.

36 MATERIALS SCIENCE↗

Comparison of Greenhouse Gas Emission Assessments of Solar and Energy Efficiency Improvements at Small Water Resource Recovery Facilities

Small water resource recovery facilities (WRRFs) account for the majority of centralized systems in the world and have higher energy intensities than large facilities. This study compares potential greenhouse gas emission reductions based on on-site solar energy and energy efficiency (E2) improvements made at small WRRFs. Case study data from 31 existing small WRRFs in Nebraska were collected and included 35 site-specific energy efficiency (E2) recommendations and on-site solar renewable energy systems integrated at three facilities, and the data were used to compare the benefits of on-site solar energy and E2 improvements made at small WRRFs. Improvements in E2 (e.g., improved aeration control) presented the largest reduction in emissions per dollar invested. They often exhibited shorter paybacks, with operational changes in aeration strategies showing the highest impact (up to 0.2 kg CO2eq/m3 treated water). On-site solar systems showed the largest net potential for reducing environmental footprint (0.35 kg CO2eq/m3) but often showed the smallest emissions reduction per cost. While the use of both E2 improvements and the integration of on-site solar renewable energy can significantly improve the sustainability of small WRRFs, on-site solar has advantages for small facilities in that it often requires less operational involvement, allows for greater facility resiliency, and presents less uncertainty in terms of environmental benefit.

Thompson, Matthew↗

Household Energy Efficiency Analysis for the City of Columbia, South Carolina

Many households in the City of Columbia, South Carolina, could save hundreds of dollars annually on their energy bills, reduce carbon emissions, and improve comfort with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for about 94,000 housing units in Columbia.

Columbia↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗