Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Localization and coherent imaging of hidden moving objects using laser speckle

Imaging and sensing of moving objects through opaque scattering media is a challenging but important problem in a variety of applications, including environmental sensing, biomedical imaging, and material inspection. We have previously demonstrated a technique to coherently image a moving object through thick, heavily scattering random media using correlations of speckle images as a function of the object’s spatial translation. Here, we demonstrate that this technique can be combined with localization to achieve imaging without prior knowledge of the object’s motion, greatly extending the application domain. This method is effective beyond the thin or weakly scattering regime and, rather than motion being deleterious, exploits the information available when the hidden object is moving, as could be the case in a cluttered terrestrial environment or through substantial levels of biological tissue scatter.

Hastings, Ryan L. (ORCID:0009000095977807)↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

NETL RDE Image Classification Dataset 2025 - 14 Classes

Dataset including high-speed down-axis RDE images used for updated image classification study. This dataset includes 180,000 images with 14 classifications: 1CW, 1CCW, 2CW, 2CCW, 3CW, 3CCW, Deflagration, 4CW, 4CCW, 5CW, and 5CCW. Images are cropped to center annulus, and resized to 301x301 pixels. Images are filtered using the AFRL Beta correction factor.

Dataset↗

NETL RDE Image Classification Dataset 2020 - 10 Classes

Dataset including high-speed down-axis RDE images used for updated image classification study. This dataset includes 100,000 images with 10 classifications: 1CW, 1CCW, 2CW, 2CCW, 3CW, 3CCW, and Deflagration. Images are cropped to center annulus, and resized to 301x301 pixels. Images are filtered using the AFRL Beta correction factor.

AS↗

AGR-2 TRISO Shadow Imaging Archive

As a part of fuel quality control characterization, backlit shadow images of particles produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-2 irradiation campaign were acquired at Oak Ridge National Laboratory (ORNL). These images may be of use for the development of image processing algorithms with the benchmark values measured at ORNL. This report provides those benchmark values, along with the raw images and data generated by the ORNL shadow imaging process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Origin of the ring ellipticity in the black hole images of M87*

We investigate the origin of the elliptical ring structure observed in the images of the supermassive black hole M87*, aiming to disentangle contributions from gravitational, astrophysical, and imaging effects. Leveraging the enhanced capabilities of the Event Horizon Telescope (EHT)'s 2018 array, including improved (u,v)-coverage from the Greenland Telescope, we measured the ring's ellipticity using five independent imaging methods, obtaining a consistent average value of τ = 0.08−0.02+0.03 with a position angle of ξ = 50.1−7.6+6.2 degrees. To interpret this measurement, we compared it to general relativistic magnetohydrodynamic (GRMHD) simulations spanning a wide range of physical parameters including the thermal or nonthermal electron distribution function, spins, and ion-to-electron temperature ratios in both low- and high-density regions. We find no statistically significant correlation between spin and ellipticity in GRMHD images. Instead, we identify a correlation between ellipticity and the fraction of non-ring emission, particularly in nonthermal models and models with higher jet emission. These results indicate that the ellipticity measured from the M87* emission structure is consistent with that expected from simulations of turbulent accretion flows around black holes, where it is dominated by astrophysical effects rather than gravitational ones. Future high-resolution imaging, including space very long baseline interferometry and long-term monitoring, will be essential to isolate gravitational signatures from astrophysical effects.Key words: accretion, accretion disks / black hole physics / gravitation / galaxies: active** These authors have contributed equally to this work.*** NASA Hubble Fellowship Program, Einstein Fellow.† Deceased.

Dahale, Rohan [Granada U., Theor. Phys. Astrophys.↗

HAMscope: a snapshot Hyperspectral Autofluorescence Miniscope for real-time molecular imaging

We introduce HAMscope, a compact, snapshot hyperspectral autofluorescence miniscope that enables real-time, label-free molecular imaging in a wide range of biological systems. By integrating a thin polymer diffuser into a widefield miniscope, HAMscope spectrally encodes each frame and employs a probabilistic deep learning framework to reconstruct 30-channel hyperspectral stacks (452-703 nm) or directly infer molecular composition maps from single images. A scalable multi-pass U-Net architecture with transformer-based attention and per pixel uncertainty estimation enables high spatio-spectral fidelity (mean absolute error ∼0.0048) at video rates. While initially demonstrated in plant systems, including lignin, chlorophyll, and suberin imaging in intact poplar and cork tissues, the platform is readily adaptable to other applications such as neural activity mapping, metabolic profiling, and histopathology. We show that the system generalizes to out-of-distribution tissue types and supports direct molecular mapping without the need for spectral unmixing. HAMscope establishes a general framework for compact, uncertainty-aware spectral imaging that combines minimal optics with advanced deep learning, offering broad utility for real-time biochemical imaging across neuroscience, environmental monitoring, and biomedicine.

59 BASIC BIOLOGICAL SCIENCES↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

An Image-Plane Approach to Gravitational Lens Modeling of Interferometric Data

Strong gravitational lensing acts as a cosmic telescope, enabling the study of the high-redshift universe. Astronomical interferometers, such as the Atacama Large Millimeter/submillimeter Array (ALMA), have provided high-resolution images of strongly lensed sources at millimeter and submillimeter wavelengths. To model the mass and light distributions of lensing and source galaxies from strongly lensed images, strong lens modeling for interferometric observations is conventionally performed in the visibility space, which is computationally expensive. In this paper, we implement an image-plane lens modeling methodology for interferometric dirty images by accounting for noise correlations. We show that the image-plane likelihood function produces accurate model values when tested on simulated ALMA observations with an ensemble of noise realizations. We also apply our technique to ALMA observations of two sources selected from the South Pole Telescope survey, comparing our results with previous visibility-based models. Our model results are consistent with previous models for both parametric and pixelated source-plane reconstructions. We implement this methodology for interferometric lens modeling in the open-source software package lenstronomy.

Zhang, Nan [Illinois U., Urbana (main)] (ORCID:000↗

Deep Learning for Spectroscopic X-ray Nano-Imaging Denoising

Synchrotron transmission X-ray microscopy with absorption near edge structure (TXM-XANES) is a powerful tool for investigating the structure and composition of materials at nano- to meso-scales. It is, however, often challenged by high levels of noise that obscure critical details at the single-pixel level. To address this issue, a deep learning-based algorithm is developed for suppressing the image noise, grounded in self-supervised learning principles. In contrast to traditional image denoising methods, this approach successfully enhances the visibility of fine details while significantly reducing the noise in the X-ray images. Through this advancement, the potential of the approach for improving the accuracy and interpretability of the TXM-XANES data is demonstrated, thereby enabling more precise detection of nanoscale phenomena such as inhomogeneous cation redox and metal segregation in battery cathode materials. This technique offers an effective new avenue for harnessing the full potential of synchrotron TXM-XANES imaging, paving the way for a range of exciting new studies in materials science and beyond.

36 MATERIALS SCIENCE↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic resolution coherent x-ray imaging with physics-based phase retrieval

Coherent x-ray imaging and scattering from accelerator based sources such as synchrotrons continue to impact biology, medicine, technology, and materials science. Many synchrotrons around the world are currently undergoing major upgrades to increase their available coherent x-ray flux by approximately two orders of magnitude. The improvement of synchrotrons may enable imaging of materials in operando at the atomic scale which may revolutionize battery and catalysis technologies. Current algorithms used for phase retrieval in coherent x-ray imaging are based on the projection onto sets method. These traditional iterative phase retrieval methods will become more computationally expensive as they push towards atomic resolution and may struggle to converge. Additionally, these methods do not incorporate physical information that may additionally constrain the solution. In this work, we present an algorithm which incorporates molecular dynamics into Bragg coherent diffraction imaging (BCDI). This algorithm, which we call PRAMMol (Phase Retrieval with Atomic Modeling and Molecular Dynamics) combines statistical techniques with molecular dynamics to solve the phase retrieval problem. We present several examples where our algorithm is applied to simulated coherent diffraction from 3D crystals and show convergence to the correct solution at the atomic scale.

47 OTHER INSTRUMENTATION↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Benchmarking image processing techniques for porosity measurement in polymer additive manufacturing: Review and experimental analysis

An image processing workflow is proposed for porosity measurement in polymer additive manufacturing. Various techniques, including global and local thresholding, region growing, and K-means clustering, were applied to microscopic images of carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS) and benchmarked for their ability to accurately measure porosity. Global methods included Otsu, minimum error, iterative, and entropy-based thresholding, while local methods included Niblack, Bernsen, Sauvola, and Bradley-Roth algorithms. Artificial uneven illumination was introduced to test local adaptive thresholds. Results showed significant differences in porosity values across methods. Otsu, region growing, and K-means clustering excelled under uniform illumination, while Sauvola and Bradley-Roth performed better with uneven illumination. Comparison with X-ray computed tomography (XCT) revealed slightly lower porosity values (2.55 %) than optimized methods (2.73–2.79 %) due to XCT's lower resolution excluding smaller pores. While XCT offers finer pore detection, it limits sample volume and underestimates porosity due to spatial variation. Validation using artificial grayscale images with 5 % porosity confirmed that Otsu, Bradley-Roth, region growing, and Sauvola algorithms produced accurate results. Although tested on a single material system, these methods can be adapted to others with optimization. In conclusion, given XCT's high computational and time costs, this study highlights suitable image processing techniques as cost-effective alternatives for porosity analysis in polymer composites.

Additive manufacturing↗