Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Study and simulation of low rate video coding schemes

The semiannual report is included. Topics covered include communication, information science, data compression, remote sensing, color mapped images, robust coding scheme for packet video, recursively indexed differential pulse code modulation, image compression technique for use on token ring networks, and joint source/channel coder design.

Sayood, Khalid↗

A CMOS Imager with Focal Plane Compression using Predictive Coding

This paper presents a CMOS image sensor with focal-plane compression. The design has a column-level architecture and it is based on predictive coding techniques for image decorrelation. The prediction operations are performed in the analog domain to avoid quantization noise and to decrease the area complexity of the circuit, The prediction residuals are quantized and encoded by a joint quantizer/coder circuit. To save area resources, the joint quantizerlcoder circuit exploits common circuitry between a single-slope analog-to-digital converter (ADC) and a Golomb-Rice entropy coder. This combination of ADC and encoder allows the integration of the entropy coder at the column level. A prototype chip was fabricated in a 0.35 pm CMOS process. The output of the chip is a compressed bit stream. The test chip occupies a silicon area of 2.60 mm x 5.96 mm which includes an 80 X 44 APS array. Tests of the fabricated chip demonstrate the validity of the design.

Leon-Salas, Walter D.↗

Information theoretical assessment of digital imaging systems

The end-to-end performance of image gathering, coding, and restoration as a whole is considered. This approach is based on the pivotal relationship that exists between the spectral information density of the transmitted signal and the restorability of images from this signal. The information-theoretical assessment accounts for (1) the information density and efficiency of the acquired signal as a function of the image-gathering system design and the radiance-field statistics, and (2) the improvement in information efficiency and data compression that can be gained by combining image gathering with coding to reduce the signal redundancy and irrelevancy. It is concluded that images can be restored with better quality and from fewer data as the information efficiency of the data is increased. The restoration correctly explains the image gathering and coding processes and effectively suppresses the image-display degradations.

John, Sarah↗

Cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}

In this paper, we study linear and cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}. The ring F{sub 2}+uF{sub 2}+vF{sub 2} is the smallest non-Frobenius ring. We characterize the structure of cyclic codes over the ring R=F{sub 2}+uF{sub 2}+vF{sub 2} using of the work Abualrub and Saip (Des Codes Cryptogr 42:273–287, 2007). We study the rank and dual of cyclic codes of odd length over this ring. Specially, we show that the equation |C||C{sup ⊥}|=|R|{sup n} does not hold in general for a cyclic code C of length n over this ring. We also obtain some optimal binary codes as the images of cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2} under a Gray map, which maps Lee weights to Hamming weights. Finally, we give a condition for cyclic codes over R that contains its dual and find quantum codes over F{sub 2} from cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}.

97 MATHEMATICS AND COMPUTING↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual Information Processing for Television and Telerobotics

This publication is a compilation of the papers presented at the NASA conference on Visual Information Processing for Television and Telerobotics. The conference was held at the Williamsburg Hilton, Williamsburg, Virginia on May 10 to 12, 1989. The conference was sponsored jointly by NASA Offices of Aeronautics and Space Technology (OAST) and Space Science and Applications (OSSA) and the NASA Langley Research Center. The presentations were grouped into three sessions: Image Gathering, Coding, and Advanced Concepts; Systems; and Technologies. The program was organized to provide a forum in which researchers from industry, universities, and government could be brought together to discuss the state of knowledge in image gathering, coding, and processing methods.

Huck, Friedrich O.↗

Area Values from Image Dimensions (AVID) v. 3

This code processes the images collected during high throughput tensile tests to measure the area of each specimen. First, the code identifies the reference images and primary sample images from list of images collected. Then, the size of the reference in the reference images is used to determine a scale (um/pixel) value which can be used to determine the size of each sample in an image. The subsequent sample images are processed to automatically detect the sample present and then identify the size in pixels. The measurements from two different views of the sample are then combined to determine the sample area (um2).

DeJong, StephanieA.↗

Evaluating the Efficacy of Wavelet Configurations on Turbulent-Flow Data

I/O is increasingly becoming a significant constraint for simulation codes and visualization tools on modern supercomputers. Data compression is an attractive workaround, and, in particular, wavelets provide a promising solution. However, wavelets can be applied in multiple configurations, and the variations in configuration impact accuracy, storage cost, and execution time. While the variation in these factors over wavelet configurations have been explored in image processing, they are not well understood for visualization and analysis of scientific data. To illuminate this issue, we evaluate multiple wavelet configurations on turbulent-flow data. Our approach is to repeat established analysis routines on uncompressed and lossy-compressed versions of a data set, and then quantitatively compare their outcomes. Our findings show that accuracy varies greatly based on wavelet configuration, while storage cost and execution time vary less. Overall, our study provides new insights for simulation analysts and visualization experts, who need to make tradeoffs between accuracy, storage cost, and execution time.

97 MATHEMATICS AND COMPUTING↗

Land Analysis System (LAS)

Version 4.1 of LAS provides flexible framework for algorithm development and processing and analysis of image data. Over 500,000 lines of code enable image repair, clustering, classification, film processing, geometric registration, radiometric correction, and manipulation of image statistics.

Pease, P. B.↗

Advanced x-ray imaging spectrometer

An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.

Callas, John L.↗

H420 Imager Calibration Procedure: Field of View Scan

Gamma-ray imagers with coded apertures have a finite field of view (FOV) within which an image of a source can be generated. A “FOV scan” is a facet of imager calibration procedure that involves collecting specialized data for a range of source locations filling the FOV in order to understand and correct for differences in imager performance. Systematic distortions reveal relative displacements between internal imager components, which can be accounted for in data analysis. The success of this scan requires a stable imager position during the full measurement duration (~hours). This document summarizes the hardware and software tools required to conduct a FOV calibration scan of an H3D H420 Coded Aperture Gamma-Ray Imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

The imaging of extra-galactic low-energy gamma-ray sources prospects, techniques, and instrumentation

Improved understanding of the nature of active galaxies will require detailed observations of 10 to 20 sources, while understanding of their gamma ray luminosity function and its evolution will require the detection of approximately 100 sources. Instruments capable of detecting 100 active galaxies at low-energy, gamma ray energies are achievable. The angular resolution of an instrument, as well as its sensitivity, can limit the number of sources it can observe. An investigation of the angular resolution requirements for future low-energy gamma ray instruments is presented. It was found that the strictest requirements arise not from the need to resolve detectable sources, but from the need to control the level of direction-to-direction fluctuations in the diffuse background level. It was concluded that gamma-ray instruments capable of detecting 100 active galaxies must have sub-degree angular resolution. The use of the coded aperture imaging technique is proposed as a method of achieving accurate control of systematic errors and fine angular resolution without unduly increasing the time needed to conduct full sky surveys. An analysis of coded aperture imaging is presented for instruments that employ masks based on hexagonal uniformly redundant arrays. An instrument, the gamma-ray imaging payload, was built that employs these imaging techniques. The design and testing of the instrument is described in detail. Preliminary results from a balloon flight of the instruments are shown, demonstrating its imaging performance.

Finger, Mark Harold↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗