Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization

Objective: The objective of this study was to evaluate the potential benefit of a dedicated cone-beam-CT streak metal artifact removal technique (SMART) in terms of both image quality and diagnostic confidence in patients undergoing bronchial artery embolization. Methods: A total of 17 patients were included in this retrospective study. The SMART algorithm was applied to images containing streak artifacts generated by a radiopaque intra-arterial catheter tip. Quantitative evaluation of artifact severity was performed via measurement of the Hounsfield units along a closed loop surrounding the catheter tip and was conducted in the frequency domain following the application of the discrete Fourier transform to the measured data. A high proportion of power in the low frequencies of the resulting spectrum indicated a high level of streak artifacts. Qualitative evaluation of diagnostic confidence was performed using a 4-point Likert scale. Results: Both quantitative and qualitative evaluation demonstrated a significant reduction in artifact severity using the SMART algorithm. Quantitative evaluation demonstrated a mean artifact reduction of 22.5% using SMART compared to non-SMART images (p < 0.001). Qualitative evaluation demonstrated the greatest artifact reduction at the inner and outer aortic curvature, as well as immediately surrounding the tip of the catheter. In 6 of 17 cases, the use of the SMART algorithm yielded additional clinical information, increasing mean diagnostic confidence from 3.17 to 3.78 (p < 0.001). Conclusion: The SMART algorithm allows for efficient reduction of metal artifacts introduced by radiopaque catheter tips during cone-beam CT. Using this algorithm, diagnostic images of the aortic arch were significantly improved both quantitatively and qualitatively, yielding clinically relevant levels of enhanced diagnostic confidence. These results demonstrate that the SMART algorithm improves diagnostic and clinical characterization of the course of bronchial arteries on CBCT images, potentially improving the accuracy and clinical efficacy of bronchial artery embolization. Level of Evidence: 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of X-Ray Computed Tomography Image Quality Indicators, "IQIs"

The intent of this effort, which is funded through the NASA OSMA NDE Program, is to develop a methodology and tools to assess Computed Tomography (CT) system performance. In particular, our team has fabricated Image Quality Indicators (IQIs) using materials and internal features useful for assessing CT detectability limits, contrast sensitivity, and resolution. Unlike traditional 2D radiography IQIs, those for CT should be more conducive to volumetric datasets and of uniform aspect ratio cross-sections.

Additive Manufacturing↗

Image quality against metric capability of an aerial camera

Glass plate targets containing multiple contrast three bar patterns and a military standard resolution target were photographed through a light-source collimator-camera system. The glass plate targets and images were then scanned. Through a computer plotting program selected portions of the scanned items were presented. The plots were then measured and analyzed to obtain information of image quality parameters and effects. The measurement errors are discussed together with aspects of resolution determination.

Ghosh, S. K.↗

Thematic Mapper image quality: Preliminary results

Based on images analyzed so far, the band to band registration accuracy of the thematic mapper is very good. For bands within the same focal plane, the mean misregistrations are well within the specification, 0.2 pixels. For bands between the cooled and uncooled focal planes, there is a consistent mean misregistration of 0.5 pixels along-scan and 0.2-0.3 pixels across-scan. It exceeds the permitted 0.3 pixels for registration of bands between focal planes. If the mean misregistrations were removed by the data processing software, an analysis of the standard deviation of the misregistration indicates all band combinations would meet the registration specifications except for those including the thermal band. Analysis of the periodic noise in one image indicates a noise component in band 1 with a spatial frequency equivalent to 3.2 pixels in the along-scan direction.

Wrigley, R. C.↗

Thematic mapper image quality - Preliminary results

Based on images analyzed so far, the band to band registration accuracy of the thematic mapper is very good. For bands within the same focal plane, the mean misregistrations are well within the specification, 0.2 pixels. For bands between the cooled and uncooled focal planes, there is a consistent mean misregistration of 0.5 pixels along-scan and 0.2-0.3 pixels across-scan. It exceeds the permitted 0.3 pixels for registration of bands between focal planes. If the mean misregistrations were removed by the data processing software, an analysis of the standard deviation of the misregistration indicates all band combinations would meet the registration specifications except for those including the thermal band. Analysis of the periodic noise in one image indicates a noise component in band 1 with a spatial frequency equivalent to 3.2 pixels in the along-scan direction.

Wrigley, R. C.↗

The influence of bowtie filtration on cone-beam CT image quality

The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie filter implemented in a system for image-guided radiation therapy (Elekta oncology system, XVI) as a compensator for improved image quality through fluence modulation, reduction in x-ray scatter, and reduction in patient dose. Dose measurements with and without the bowtie filter were performed on a CTDI Dose phantom and an empirical fit was made to calculate dose for any radial distance from the central axis of the phantom. Regardless of patient size, shape, anatomical site, and field of view, the bowtie filter results in an overall improvement in CT number accuracy, image uniformity, low-contrast detectability, and imaging dose. The implemented bowtie filter offers a significant improvement in imaging performance and is compatible with the current clinical system for image-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tradeoffs among several synthetic aperture radar image quality parameters - Results of a user survey study

The imagery obtained with the aid of synthetic aperture radars (SAR) has been applied to several remote sensing disciplines such as geologic feature mapping, oceanic phenomena studies, and land use and urban morphology studies. The successful SAR experiment on Seasat and the Shuttle demonstrated the feasibility of global radar mapping at relatively high resolution from a spaceborn platform. The present investigation is concerned with the requirements of and the tradeoffs among several SAR image quality parameters. The results are presented from a survey study concerning the interpretability of a set of SAR images. The data used to generate these images were obtained by the Seasat SAR experiments. Attention is given to image scenes and the simulation experiment, image interpretation survey results, multiple-looks, the number of looks vs resolution, and number of bits vs resolution.

Li, F. K.↗

Evaluation of image quality in a Cassegrain-type telescope with an oscillating secondary mirror

A ray-trace analysis is described of aberrations and extreme rays of a Cassegrain-type telescope with a tilted secondary mirror. The work was motivated by the need to understand the factors limiting image quality and to assist in the design of secondary mirrors for three telescopes with oscillating secondary mirrors (OSM) used at Ames Research Center for high altitude infrared astronomy. The telescopes are a 31-cm-diameter Dall-Kirkham (elliptical primary, spherical secondary) flown aboard a Lear jet, a 71-cm balloon-borne Dall-Kirkham flown on the AIROscope gondola, and a 91-cm true Cassegrain (parabolic primary, hyperbolic secondary) flown aboard a C-141 jet transport. The optics for these telescopes were not designed specifically for OSM operation, but all have OSM's and all must be used with various detector configurations; therefore, a facility that evaluates the performance of a telescope for a given configuration is useful. The analytical expressions are summarized and results for the above systems are discussed. Details of the calculation and a discussion of the computer program are given in the appendices.

Erickson, E. F.↗

Improvements in the Image Quality of Neutron Radiograms of NUR Neutron Radiography Facility by Using Several Exposure Techniques

Since the construction of NUR reactor neutron radiography facility in 1991, only transfer exposure method was used as a non destructive technique. The reason is the excess of gamma rays in the neutron beam. To improve radiation performances of the NR system, a stainless steal hollow conical cylinder is introduced at the bottom of the facility beam port, this filter reduce gamma infiltration through the edges of the NR structure without disturbing neutron beam arriving from the in pool divergent collimator. First results confirm our prediction; a gamma rays diminution and a relatively stable neutron flux at the point object are confirmed, consequently the n/{gamma} ratio reaches a value of 2.104 n/cm{sup 2} mR. Radiograms obtained by using the direct exposure method reveal the feasibility of the technique in the new NR configuration facility, but a weak resolution and contrast of the image is observed. In this paper, we describe a procedure to improve the image quality obtained by direct exposure technique. The process consists of using digitized images obtained by several exposure techniques (NR, gamma radiography or X radiography) for a comparison study and then better image definition can be attained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Image quality indicator and dechromator setup for static LANSCE proton radiography experiment

This document describes a static geometry consisting of a sphere of gold and Ti-6Al-4V alloy, along with an energy-loss matching dechromator composed of polycarbonate, to field with the X3 electromagnetic magnifying lens at LANSCE during the next beam cycle. This static configuration will allow us to: (1) characterize the system’s resolution at the material interface between the gold and titanium alloy, and test the image quality for fine features associated with the screws used to fasten the titanium alloy hemispheres; (2) tune our models of proton scattering and imaging for these materials; and (3) test a procedure to align the polycarbonate dechromator and the sphere within the proton beamline. The data will also be suitable for validation of the software options available for proton radiography simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the Effects of Hard Limiting on Image Quality of Synthetic Aperture Radar

Starting with a magnetic tape of a scene viewed by the Landsat satellite, the radar return of reflectors whose average intensity matched that of the picture elements in the scene has been simulated. The returns were processed in three ways: normally or with no quantization, with a procedure simulation IF hard limiting, and with a procedure simulating video (baseband) hard limiting. For each type of processing an image for a one, two, and four-look system has been developed. It was found that IF limiting is slightly better than video limiting, while both can be reasonable trade-offs of image quality for reduced data rates when the number of looks is four or less. These conclusions are supported by photographs representing the different processing techniques.

Lipes, R. G.↗

SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols

Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with three protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy.

60 APPLIED LIFE SCIENCES↗

Development of Software to Model AXAF-I Image Quality

This draft final report describes the work performed under the delivery order number 145 from May 1995 through August 1996. The scope of work included a number of software development tasks for the performance modeling of AXAF-I. A number of new capabilities and functions have been added to the GT software, which is the command mode version of the GRAZTRACE software, originally developed by MSFC. A structural data interface has been developed for the EAL (old SPAR) finite element analysis FEA program, which is being used by MSFC Structural Analysis group for the analysis of AXAF-I. This interface utility can read the structural deformation file from the EAL and other finite element analysis programs such as NASTRAN and COSMOS/M, and convert the data to a suitable format that can be used for the deformation ray-tracing to predict the image quality for a distorted mirror. There is a provision in this utility to expand the data from finite element models assuming 180 degrees symmetry. This utility has been used to predict image characteristics for the AXAF-I HRMA, when subjected to gravity effects in the horizontal x-ray ground test configuration. The development of the metrology data processing interface software has also been completed. It can read the HDOS FITS format surface map files, manipulate and filter the metrology data, and produce a deformation file, which can be used by GT for ray tracing for the mirror surface figure errors. This utility has been used to determine the optimum alignment (axial spacing and clocking) for the four pairs of AXAF-I mirrors. Based on this optimized alignment, the geometric images and effective focal lengths for the as built mirrors were predicted to cross check the results obtained by Kodak.

Ahmad, Anees↗

Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

47 OTHER INSTRUMENTATION↗

Impact of chopping on image quality in the SIRTF telescope

The initial Phase-A concept for the Space Infrared Telescope Facility (SIRTF), which was established in 1981, is concerned with a cryogenically cooled, 85 cm diameter, f/24 Ritchey-Chretien telescope, followed by a Multiple Instrument Chamber (MIC), containing six scientific instruments. In 1982, the Phase-A concept was reviewed with the aim to assess the technical readiness for the next phase of development. Various areas of concern were subsequently investigated in three parallel studies by industry. Two of the arising questions are considered in the present paper, taking into account the system and technology implications of achieving diffraction-limited resolution at 2 microns, and the limitations on the size of the imaging field under this condition. The conducted study takes into account an evaluation of the different methods of chopping. Attention is given to the telescope parameters, symmetric chopping, asymmetrical chopping, focus and alignment errors, the wavefront-error budget, and image quality.

Bottema, M.↗

SU-E-J-155: Automatic Quantitative Decision Making Metric for 4DCT Image Quality

Purpose: To develop a quantitative decision making metric for automatically detecting irregular breathing using a large patient population that received phase-sorted 4DCT. Methods: This study employed two patient cohorts. Cohort#1 contained 256 patients who received a phasesorted 4DCT. Cohort#2 contained 86 patients who received three weekly phase-sorted 4DCT scans. A previously published technique used a single abdominal surrogate to calculate the ratio of extreme inhalation tidal volume to normal inhalation tidal volume, referred to as the κ metric. Since a single surrogate is standard for phase-sorted 4DCT in radiation oncology clinical practice, tidal volume was not quantified. Without tidal volume, the absolute κ metric could not be determined, so a relative κ (κrel) metric was defined based on the measured surrogate amplitude instead of tidal volume. Receiver operator characteristic (ROC) curves were used to quantitatively determine the optimal cutoff value (jk) and efficiency cutoff value (τk) of κrel to automatically identify irregular breathing that would reduce the image quality of phase-sorted 4DCT. Discriminatory accuracy (area under the ROC curve) of κrel was calculated by a trapezoidal numeric integration technique. Results: The discriminatory accuracy of ?rel was found to be 0.746. The key values of jk and tk were calculated to be 1.45 and 1.72 respectively. For values of ?rel such that jk≤κrel≤τk, the decision to reacquire the 4DCT would be at the discretion of the physician. This accounted for only 11.9% of the patients in this study. The magnitude of κrel held consistent over 3 weeks for 73% of the patients in cohort#3. Conclusion: The decision making metric, ?rel, was shown to be an accurate classifier of irregular breathing patients in a large patient population. This work provided an automatic quantitative decision making metric to quickly and accurately assess the extent to which irregular breathing is occurring during phase-sorted 4DCT.

60 APPLIED LIFE SCIENCES↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗