Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor simulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Review of Noise Metric Sensitivities for Analysis of Quiet Supersonic Overflight

Six different noise metrics (PL, ASEL, BSEL, DSEL, ESEL, and ISBAP) are currently used to quantify sonic boom levels from overflight of supersonic aircraft. A previous meta-analysis using laboratory subjective data identified these metrics, each of which correlated well with human perception of low-boom sounds both indoors and outdoors. Because the analysis did not identify a single metric that was significantly superior, no internationally agreed-upon metric has been chosen for the quiet supersonic aircraft noise certification procedures currently under development. Other analyses of metric sensitivities using existing empirical and simulation datasets, however, have shown significant differences between metrics. Variability of metrics due to macro-atmospheric effects and atmospheric turbulence perturbations have been explored, as well as variability in measurements due to microphone setup configurations, array layouts, and ambient noise effects. This paper reviews these prior studies, summarizes the current understanding of metric sensitivities, and discusses how they may impact future downselection of metrics for certification procedures.

sonic boom↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User’s Manual for RESRAD-BUILD Code V.4: Vol. 1 – Methodology and Models Used in RESRAD-BUILD Code

The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.

61 RADIATION PROTECTION AND DOSIMETRY↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Dynamically Downscaled Hourly Future Weather Data with 12-km Resolution Covering Most of North America

This is an hourly future weather dataset for energy modeling applications. The dataset is primarily based on the output of a regional climate model (RCM), i.e., the Weather Research and Forecasting (WRF) model version 3.3.1. The WRF simulations are driven by the output of a general circulation model (GCM), i.e., the Community Climate System Model version 4 (CCSM4). This dataset is in the EPW format, which can be read or translated by more than 25 building energy modeling programs (e.g., EnergyPlus, ESP-r, and IESVE), energy system modeling programs (e.g., System Advisor Model (SAM)), indoor air quality analysis programs (e.g., CONTAM), and hygrothermal analysis programs (e.g., WUFI). It contains 13 weather variables, which are the Dry-Bulb Temperature, Dew Point Temperature, Relative Humidity, Atmospheric Pressure, Horizontal Infrared Radiation Intensity from Sky, Global Horizontal Irradiation, Direct Normal Irradiation, Diffuse Horizontal Irradiation, Wind Speed, Wind Direction, Sky Cover, Albedo, and Liquid Precipitation Depth. The weather data is created for two emissions scenarios: RCP4.5 and RCP8.5 and spans two 10-year time slices in the future: 2045 - 2054 and 2085 - 2094. It offers a spatial resolution of 12 km by 12 km with extensive coverage across most of North America. Due to the enormous size of the entire dataset, in the first stage of its distribution, we provide 20 years of future weather data for the centroid of each Public Use Microdata Area (PUMA), excluding Hawaii. PUMAs are non-overlapping, statistical geographic areas that partition each state or equivalent entity into geographic areas containing no fewer than 100,000 people each. The 2,378 PUMAs as a whole cover the entirety of the U.S. The weather data can be utilized alongside the large-scale energy analysis tools, ResStock and ComStock, developed by National Renewable Energy Laboratory, whose smallest resolution is at the PUMA scale. The data for RCP4.5 is still being processed and will be published soon.

Array↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor test and long-term weathering effects on the thermal performance of the solar energy system (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on a liquid solar collector are presented. The narrow flat plate collector with reflective concentrating mirrors uses water as the working fluid. The double-covered collector weighs 137 pounds and has overall dimensions of about 35" by 77" by 6.75". The test program was conducted to obtain the following information: thermal performance data under simulated conditions, structural behavior under static load, and the effects of long term exposure to natural weathering.

Source record↗

Scaling Deep Energy Retrofits for Residential Walls - Energy, Cost, and Economic Assessment of Five Wall Systems

Providing strong economic and performance value is a primary challenge of convincing homeowners to implement deep energy retrofits to their wall systems. This study combines energy modeling and technoeconomic assessment of six experimental residential retrofit wall systems to typical existing homes in cold climates to evaluate their energy performance and cost effectiveness. Deep energy retrofits can significantly improve the energy performance of a home’s thermal envelope, help manage indoor environmental pollutants, increase homeowner comfort, increase building value, and register significant energy and cost savings in the process. We are evaluating exterior wall retrofit components and construction practices to measure and recommend steps to improve financial performance for manufacturers, installers and consumers. This study leverages a literature review, inputs from an advisory group made up of thermal enclosure experts, and simulations to identify state-of-the-art technologies for energy efficient wall systems that are suitable for cold and very cold climate zones. This paper will present results from energy modeling of six experimental wall systems compared to one baseline, that inform cost and energy performance of the subject wall systems.

Ganguli, Sumitrra↗