Search NASA⌕ Search

SEARCH · Search NASA

Results for “Induced coherence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Advanced NDE research in electromagnetic, thermal, and coherent optics

A new inspection technology called magneto-optic/eddy current imaging was investigated. The magneto-optic imager makes readily visible irregularities and inconsistencies in airframe components. Other research observed in electromagnetics included (1) disbond detection via resonant modal analysis; (2) AC magnetic field frequency dependence of magnetoacoustic emission; and (3) multi-view magneto-optic imaging. Research observed in the thermal group included (1) thermographic detection and characterization of corrosion in aircraft aluminum; (2) a multipurpose infrared imaging system for thermoelastic stress detection; (3) thermal diffusivity imaging of stress induced damage in composites; and (4) detection and measurement of ice formation on the space shuttle main fuel tank. Research observed in the optics group included advancements in optical nondestructive evaluation (NDE).

Skinner, S. Ballou↗

Nonlinear twist-kink instability of a coronal loop

Three-dimensional magnetoinductive particle simulations are used to demonstrate that the mechanical twisting motion applied to a magnetized plasma column induces a current aligned to the external magnetic field direction, pinches the plasma and magnetic fields, and stores the energy in poloidal magnetic fields. As the twist motion continues, the field lines locally begin to wrap around the plasma more than one revolution. A strong MHD instability sets in that is a mixture of kink and ballooning modes, releasing the magnetic energy and causing destruction of coherent column structure and flows of turbulent plasma. A similar episode ensues, exhibiting relaxation oscillations. The buildup of poloidal fields and structure and its sudden release driven by the twist motion may be a model for the solar coronal loop dynamics which exhibits a slow energy buildup with some photospheric motion and a sudden energy release by flares.

Zaidman, E. G.↗

Injection Induced Mixing in Flows Separating From Smooth Surfaces

An analytic model for predicting the effect of unsteady local surface injection on the flow separating from a streamlined body at angle of attack is proposed. The model uses the premise that separation control results from enhanced mixing along the shear layer that develops between the main stream and the fluid in the underlying recirculation zone. High-Reynolds-number asymptotic methods are used to connect the unsteady surface injection to an instability wave propagating on the separating shear layer and then to the large-scale coherent structures that produce the increased mixing. The results is a tool that can guide the choice of fluid-actuator parameters to maximize flow-control effectiveness and may also facilitate computer-based numerical experiments.

Adamczyk, John J.↗

Self-Aligned Focusing Schlieren and OH Planar Laser-Induced Fluorescence Flow Visualization in a Dual-Mode Scramjet

Ahigh-speed self-aligned focusing schlieren (SAFS) system was used to visualize density gradients in and around the cavity flameholder of the combustor section of the University of Virginia Supersonic Combustion Facility (UVASCF). Images with this system were acquired at a framing rate of 110 kHz with no fuel injection, with fuel injection but no flame, and for fuel injection with combustion corresponding to a global equivalence ratio of 𝜙 = 0.18. Images with an air throttle in operation to modify the shock train location with fuel injection and with flame were also acquired. Simultaneous OH planar laser-induced fluorescence (PLIF) images were also acquired at a framing rate of 20 Hz. Results obtained with both visualization techniques are compared to one another to highlight how SAFS can complement more advanced flow visualization techniques and resolve dynamic behavior that may not otherwise be captured. Both proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) analysis techniques are applied to the SAFS image sequences to identify coherent periodic structures for the runs with fuel injection and combustion.

Brett F Bathel↗

Space Flight-Induced Intracranial Hypertension: An Ophthalmic Review

Background: Although physiologic and pathologic changes associated with microgravity exposure have been studied extensively, the effect of this environment on the eye is largely unknown. Over the last several years, NASA s Space Medicine Division has documented astronauts presenting with varying degrees of disc edema, globe flattening, choroidal folds, cotton wool spots, and hyperopic shifts after long-duration space flight. Methods: Before and after long-duration space flight, six astronauts underwent complete eye examinations to include cycloplegic and/or manifest refraction and fundus photography. Five of these astronauts had Optical Coherence Tomography (OCT) and Magnetic Resonance Imaging (MRI) performed following their missions. Results: Following exposure to space flight of approximately 6-months duration, six astronauts had neuro-ophthalmic findings. These consisted of disc edema in four astronauts, globe flattening in four astronauts, choroidal folds in four astronauts, cotton wool spots in three astronauts, nerve fiber layer thickening by OCT in five astronauts, and decreased near vision in five astronauts. Four of the astronauts with near vision complaints had a hyperopic shift equal to or greater than + 0.50D between pre- and post-mission spherical equivalent refraction in one or both eyes (range +0.50D to +1.50D). These same four had globe flattening by MRI. Conclusions: The findings we describe may have resulted from a rise in intracranial pressure caused by microgravity fluid shifts, and could represent parts of a spectrum of ocular and cerebral responses to extended microgravity.

Gibson, Charles Robert↗

Stark effect applicable to optically pumped far-infrared laser

Absorption measurements at CO2 laser frequencies were carried out as a function of Stark fields and CH3OH gas pressures to assess the effect of low electric field Stark tuning on methanol absorption at the P(12) 9.4 micron CO2 laser line, in a continuing search for coherent emitters at submillimeter wavelengths (far infrared). The line center absorption coefficient is found to increase five-fold with a 2.3 kV/cm Stark field at the 220 mtorr methanol pressure optimal for methanol far infrared lasing. The low electric field Stark tuning encourages efforts to enhance the pumping efficiency of a methanol far infrared laser at its normal optimum operating pressure, and suggests that significant Stark field induced frequency modulation of the far IR laser output is feasible.

Claspy, P. C.↗

Analytical and experimental evaluations of Space Shuttle TPS tile vibration response

Analytical studies and laboratory experiments have been performed to evaluate the vibration response of the Space Shuttle Thermal Protection System (TPS) tiles due to the intense rocket generated acoustic noise during lift-off. The TPS tiles are mounted over the exterior of the Space Shuttle Orbiter structure through Strain Isolation Pads (SIP) which protect the tiles from thermal induced shear loads at their interface. The analytical predictions indicate that the response of a typical tile is governed by the structural vibration inputs through the SIP under the tile at frequencies below 250 Hz, and by the direct acoustic excitation over the exterior surface of the tile at frequencies above 250 Hz. An evaluation of the laboratory test data for this same tile, in which conditioned (partial) coherent output spectral analysis procedures were used, leads to exactly the same conclusion. The results demonstrate the power of conditioned spectral analysis procedures in identifying vibration response mechanisms when two or more of the inputs are highly correlated.

Piersol, A. G.↗

Electric field effect in superconductor-ferroelectric structures

Electric field effect (the E-effect) in superconductors has been studied since 1960 when Glover and Sherill published their results on a shift of the critical temperature T(sub c) about 0.1 mK in Sn and In thin films under the action Off the field E=300 kV/cm. Stadler was the first to study the effect or spontaneous polarization of ferroelectric substrate on the electric properties of superconductors. He observed that the reversal of polarization of TGS substrate under action of external electric field in Sn-TGS structures induced the T(sub c) shift in Sn about 1.3 mK. Since in this case the effect is determined not by the electric field but by the spontaneous polarization, we may call this effect the P-effect. High-T(sub c) superconductors opened the new possibilities to study the E- and P-effects due to low charge carrier density, as compared to conventional superconductors, and to anomalously small coherence length. Experiments in this field began in many laboratories but a breakthrough was made where a shift in T(sub c) by 50 mK was observed in YBCO thin films. Much higher effects were observed in subsequent studies. The first experiments on the P-effect in high-T(sub c) superconductors were reported elsewhere. In this report we shall give a short description of study on the P-effect in high-T(sub c) superconductors.

Lemanov, V. V.↗

Velocity-changing collisional effects in nonlinear atomic spectroscopy and photon echo decay in gases

A general theory of atomic dipole coherence under the influence of collisional phase changes, inelastic effects and optically active atom velocity changes, including those due to anisotropic interactions is presented. Velocity change effects are obtained in closed form. Line shapes appear as convolutions of standard pressure broadening contours with velocity-change contours. Width and shift parameters for the He-broadened Na D lines at 2 m bar pressure, 380 K are calculated, as are He-induced photon echo decay rates for these lines. Overall agreement with xperiment is reasonably good.

Herman, R. M.↗

Solar Pumped High Power Solid State Laser for Space Applications

Highly coherent laser light provides a nearly optimal means of transmitting power in space. The simplest most direct means of converting sunlight to coherent laser light is a solar pumped laser oscillator. A key need for broadly useful space solar power is a robust solid state laser oscillator capable of operating efficiently in near Earth space at output powers in the multi hundred kilowatt range. The principal challenges in realizing such solar pumped laser oscillators are: (1) the need to remove heat from the solid state laser material without introducing unacceptable thermal shock, thermal lensing, or thermal stress induced birefringence to a degree that improves on current removal rates by several orders of magnitude and (2) to introduce sunlight at an effective concentration (kW/sq cm of laser cross sectional area) that is several orders of magnitude higher than currently available while tolerating a pointing error of the spacecraft of several degrees. We discuss strategies for addressing these challenges. The need to remove the high densities of heat, e.g., 30 kW/cu cm, while keeping the thermal shock, thermal lensing and thermal stress induced birefringence loss sufficiently low is addressed in terms of a novel use of diamond integrated with the laser material, such as Ti:sapphire in a manner such that the waste heat is removed from the laser medium in an axial direction and in the diamond in a radial direction. We discuss means for concentrating sunlight to an effective areal density of the order of 30 kW/sq cm. The method integrates conventional imaging optics, non-imaging optics and nonlinear optics. In effect we use a method that combines some of the methods of optical pumping solid state materials and optical fiber, but also address laser media having areas sufficiently large, e.g., 1 cm diameter to handle the multi-hundred kilowatt level powers needed for space solar power.

Fork, Richard L.↗

Coherence Effects in Ring Laser Gyros

We predict the propagation of slow and fast light in two co-resonant coupled optical resonators. In coupled resonators, slow light can propagate without attenuation by a cancellation of absorption as a result of mode splitting and destructive interference, whereas transparent fast light propagation can be achieved by the assistance of gain and splitting of the intracavity resonances, which consequently change the dispersion from normal to anomalous. The effective steady-state response of coupled- resonators is derived using the temporal coupled-mode formalism, and the absorptive and dispersive responses are described. Specifically, the occurrence of slow light via coupled-resonator-induced transparency and gain-assisted fast light are discussed. Keywords: whispering gallery modes, optical resonators, slow light, fast light, superluminal pulse propagation, coupled optical resonators.

Smith, David D.↗

Diffraction and Imaging Study of Imperfections of Protein Crystals with Coherent X-rays

High angular-resolution x-ray diffraction and phase contrast x-ray imaging were combined to study defects and perfection of protein crystals. Imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of a uniformly grown lysozyme crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in diffraction images. X-ray imaging and diffraction characterization of the quality of apoferritin crystals will also be discussed in the presentation.

Hu, Z. W.↗

Resonance between coherent whistler mode waves and electrons in the topside ionosphere

Landau resonance and cyclotron resonance of coherent whistler mode waves and energetic electrons are explored for magnetoplasmas with appreciable gradients in the plasma density and magnetic field strength. It is shown that in the topside ionosphere of the earth near the ion transition height the gradients in plasma density and magnetic field strength along a magnetic field line may match in a way which enhances both Landau and cyclotron interactions between waves and electrons at the loss cone pitch angle. The pitch angle scattering induced by a signal from a ground-based VLF transmitter in the ionosphere above the transmitter has been estimated and compared to the pitch angle scattering induced by naturally occurring ELF hiss through cyclotron resonance. It is found that the expected scattering due to plasmapheric hiss is an order of magnitude larger than that due to Landau resonance in the topside ionosphere. Pitch angle scattering due to cyclotron resonance in the topside ionosphere, however, may be larger by a factor of 2. It is suggested that the 'fast Trimpi' effect may be caused by a cyclotron resonance interaction in the topside ionosphere.

Neubert, T.↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Large-scale coherent structure and far-field jet noise

The phenomenon of broadband noise amplification/suppression under controlled excitation is investigated. The suppression is found to occur only at low jet speeds when the exit boundary layer is laminar; excitation at a Strouhal St(theta) number of about 0.017 results in optimum suppression of the far-field broadband noise as well as of the near-flow-field turbulence. The noise amplification is found to be a function of the Mach number, the amplification is higher at higher Mach number for a given excitation Strouhal number and level. The amplification also depends on the Strouhal number (St D), the maximum occurring in the range 0.65-0.85. Vortex pairing induced by the excitation appears to be at the heart of the noise amplification phenomenon under excitation.

Zaman, K. B. M. Q.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Optical Control of Intersubband Absorption in a Multiple Quantum Well-Embedded Semiconductor Microcravity

Optical intersubband response of a multiple quantum well (MQW)-embedded microcavity driven by a coherent pump field is studied theoretically. The n-type doped MQW structure with three subbands in the conduction band is sandwiched between a semi-infinite medium and a distributed Bragg reflector (DBR). A strong pump field couples the two upper subbands and a weak field probes the two lower subbands. To describe the optical response of the MQW-embedded microcavity, we adopt a semi-classical nonlocal response theory. Taking into account the pump-probe interaction, we derive the probe-induced current density associated with intersubband transitions from the single-particle density-matrix formalism. By incorporating the current density into the Maxwell equation, we solve the probe local field exactly by means of Green's function technique and the transfer-matrix method. We obtain an exact expression for the probe absorption coefficient of the microcavity. For a GaAs/Al(sub x)Ga(sub 1-x)As MQW structure sandwiched between a GaAs/AlAs DBR and vacuum, we performed numerical calculations of the probe absorption spectra for different parameters such as pump intensity, pump detuning, and cavity length. We find that the probe spectrum is strongly dependent on these parameters. In particular, we find that the combination of the cavity effect and the Autler-Townes effect results in a triplet in the optical spectrum of the MQW system. The optical absorption peak value and its location can be feasibly controlled by varying the pump intensity and detuning.

Liu, Ansheng↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure syndrome (VIIP) is a newly described space flight-associated medical condition made up of a constellation of symptoms affecting at least 34% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures, and is thought to be related to elevated intracranial pressure secondary to space flightinduced cephalad fluid shifts. Loss of visual acuity could be a significant threat to crew health and performance and may be suggestive of other adaptations with implications for years post-flight. Our primary objective is to determine whether vascular compliance is altered by space flight and whether such adaptations are related to the incidence of VIIP. In particular, we will measure ocular parameters and vascular compliance in vessels of the head and neck in astronauts who have no space flight experience, in astronauts before, during, and after space flight, and in bed rest subjects with conditions similar to space flight. Additionally, we will analyze astronaut data from the Lifetime Surveillance of Astronaut Health (LSAH) archive to determine which factors might be predictive of the development of VIIP. The project will be conducted in four separate but related parts. To understand the baseline condition of astronauts without any prior space flight experience, we will study 10 astronauts who have never flown in space by performing a comprehensive evaluation of the vasculature of the head, neck and eyes. Hemodynamic data (stroke volume and blood pressure), ocular (tonometry and ocular ultrasound), venous and arterial parameters will be acquired across a range of tilt angles (20, 10, 0, -10, -20 degrees). Vessels to be studied include the temporal, jugular, and vertebral veins and the cerebral, carotid and vertebral arteries. Ophthalmic data from the annual physical will be obtained through data sharing. To examine the relation between vascular compliance in the head and neck and the development of VIIP after a long duration space flight, we will study 10 astronauts before, during, and after long-duration ISS missions. Pre- and post-flight testing will be identical to that described above. During flight, images of the same vessels of interest will be obtained for later analysis. Ophthalmic data including VIIP scores will be obtained through data sharing from medically-required tests. To investigate the effects of age and elevated sodium intake, two potential contributors to VIIP, we will study 24 men (in two age groups: 25-35 and 45-55) during a 14 day 6deg head-down bed rest, a well-accepted analog of space flight. Standard NASA bed rest conditions will be maintained except for dietary sodium. Sodium intake will be similar to that of ISS astronauts, which is higher than consumed in previous bed rest studies. Pre- and post-bed rest testing procedures will be identical to the testing protocol described above for astronauts. Ophthalmic testing (optical coherence tomography, fundoscopy, and tonometry) will be conducted on the same day that vascular compliance measures are obtained. To identify parameters that may relate to an increase in an astronaut's susceptibility to developing VIIP, we will use data mining techniques to evaluate astronaut data obtained from the LSAH. Medical history, family history, space flight history and its related exposures, and history of high performance jet aircraft exposure will be examined for their potential relationship to ocular data. We hypothesize that the cephalad fluid shift induced by space flight will result in structural and functional adaptations in head and neck vessels leading to decreased vascular compliance and related to the development of VIIP symptoms. Further, although VIIP has not been observed in previous bed rest studies, we hypothesize that an elevated sodium intake will increase the incidence of VIIP symptoms in this space flight analog. Finally, we hypothesize that data mining analyses will reveal relationships between health history, previous exposures (including space flight and high performance aircraft), and the development of VIIP in the astronaut population.

Ribeiro, L. C.↗