Search NASA⌕ Search

SEARCH · Search NASA

Results for “Installation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Risk Analysis of Radiological Release from Pu-238 Targets During Manual Handling

Pu-238 Isotope Production Targets are routinely installed in the Advanced Test Reactor (ATR) core, transferred, and stored in the spent fuel canal. These evolutions involve manual handling and manipulation of the targets underwater using long handled tools. The ATR Safety Analysis Report (SAR) postulates a design basis accident which results in damage from manual manipulation of targets, and radiological consequences must be determined for receptors inside the reactor facility, as well as public receptors. This presentation presents the analysis used to determine the radiological consequences due to potential target damage in the ATR canal. The analysis considered radionuclide release fractions, damage ratios for handling evolutions, and entrainment of radionuclides in the canal water.

Advanced Test Reactor↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Dust and Corrosion Witness Samples Recovered from SNF Dry Storage Systems, Maine Yankee, 2023

This report documents the results of a long-term (5.79 year) exposure of 4-point bend corrosion test samples in the inlet and outlet vents of four spent nuclear fuel dry storage systems at the Maine Yankee Independent Spent Fuel Storage Installation. The goal of the test was to evaluate the corrosiveness of salt aerosols in a realistic near-marine environment, providing a data set for improved understanding of stress corrosion cracking of spent nuclear fuel dry storage canisters. Examination of the samples after extraction showed minor corrosion was present, mostly on rough-ground surfaces. However, dye penetrant testing showed that no SCC cracks were present. Dust collected on coupons co-located with the corrosion specimens was analyzed by scanning electron microscopy and leached to determine the soluble salts present. The dust was mostly organic material (pollen and stellate trichomes), with lesser detrital mineral grains. Salts present were a mix of sea-salts and continental salts, with chloride dominating the anions, but significant amounts of nitrate were also present. Both corrosion samples and dust samples showed evidence of wetting, indicating entry of water into the vents. The results of this field test suggest that the environment at Maine Yankee is not highly aggressive, although extrapolation from the periodically wetted vent samples to the hot, dry, canister surface may be difficult. No stress corrosion cracks were observed, but minor corrosion was present despite high nitrate concentrations in the salts. These observations may help address the ongoing question of the importance of nitrate in suppressing corrosion and SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY20, 3rd Quarter, Multi-pass Hybrid Laser Arc Welding of Alloy 740H

Although progress has been slowed by telecommuting restrictions at INL and PSU, progress has been made by PSU on modeling and simulation of deep penetration laser welding. Additionally, both INL and PSU has received critical equipment, in the form of high-powered laser wobble heads, needed to verify the modeling and simulation results. The equipment was installed at INL and preliminary tests, based on a test matrix that was developed in this 3rd quarter, will be made early in the 4th quarter. Similarly, the PSU laser wobble head is expected to be installed early in the 4th quarter and preliminary experiments are expected to commence shortly thereafter. Completion dates on a few milestones have been impacted and new dates proposed.

36 MATERIALS SCIENCE↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

Upgrade of Core Conduction Cooldown Test Facility Control System

The CCCTF was designed and installed at ORNL in the 1990s for high-temperature gas-cooled reactor accident simulation. It is located within a modular hot cell housed in the IFEL facility. In 2008 and 2009, modifications were made to the CCCTF in preparation for AGR safety testing. A new airlock was designed and installed to better support periodic exchange of the fission product deposition cups while maintaining the fuel at safety test temperature, and modifications were made to add routines to the existing user interface software for computer-controlled automation of the He sweep gas flow and liquid nitrogen supply to the 85Kr cold traps. However, the furnace control hardware and software remained essentially unchanged. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, continued use of the CCCTF was in question because of the gradual obsolescence of the hardware and software used to control the furnace and ancillary systems that make up the CCCTF. Therefore, an effort was undertaken to replace all the obsolete components with new hardware and update the software to increase system reliability and ensure this capability’s maintenance for future research and fuel qualification efforts. The modifications included creating a new National Instruments (NI) LabVIEW-based control system with a graphical user interface (GUI).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examination of an Electrified Bar Rack Fish Guidance Device for Hydropower Turbines

The potential of hydropower turbines to cause injury or mortality to fish is a concern. To reduce this risk, engineers have begun to develop a conically arranged, cantilevered electrified bar rack (Center Sender). This device is proposed to be mounted within the intake of a turbine, guiding downstream-passing fish towards the center of the turbine where blade velocities are lower and blades are thicker, likely reducing the potential for fish to be injured. A simplified version was installed in a flume for testing with Rainbow trout (Oncorhynchus mykiss) while examining several parameters such as electrification, bar spacing, bar angle, and water velocity. The most effective settings were observed to be a water velocity of 1.0 m s -1 with all bars installed at an angle of 40° with electrification on. Other combinations were still effective but had varying results. A minimal proportion (2.3%) of fish passed at lower velocities with bars electrified and mounted at 20°, suggesting that while it functions well as a guidance device in high-velocity conditions, it performs better as a barrier at lower velocities. The study suggests that the Center Sender has promising potential for reducing the harmful effects of hydropower turbines on fish populations by guiding them away from stressors. Further research is needed, but current results encourage its potential use in hydropower operations.

13 HYDRO ENERGY↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

Cryogenic Testing of HL-LHC Q1/Q3 Cryo-Assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 Cryo-Assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-Assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressures up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvements for subsequent tests.

Rabehl, R. [Fermilab]↗

Cryogenic testing of HL-LHC Q1/Q3 cryo-assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 cryo-assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvement for subsequent tests.

Rabehl, R. [Fermilab] (ORCID:0000000311130030)↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping (FY2023 Mid-Year Report)

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in FY2022. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2023. Note that the Cask Farm contractor determines this scheduling and not INL directly. Further system automation will be designed and implemented with the goal of obtaining a level of system operation that meets IAEA needs. This includes integration of the scanner array and data-acquisition control software into a single interface for operator use. In addition, commercial operators and the IAEA may have special requirements for portability, shipping, lifting, and installation. Prior to the Field Test at INL, the system will be operated at LLNL to exercise lifting procedure and linear actuators, monitor stability of detector energy and pulse-shape discrimination calibration, and test system software integration efforts. Following the Field Test, we will present results and discuss the technology with the IAEA. We will incorporate additional improvements to the system based on lessons learned from the field test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

“Mirror” magnet experiment for quench studies, quench analysis techniques development and in support of superconducting magnet modeling

In order to progress on various research points related to superconducting magnets, we suggest performing series of tests with induced and natural quenches on a mirror magnet, probably using a “11 T” coil. The “mirror” is to have voltage taps instrumented on half the strands, on both coil ends. It is to be instrumented with multiple spot-heaters, of the order of ten, in designated pole-turn areas. Instrumentation is to include quench antenna array facing the inner coil surface, as well as acoustic sensors on the inner layer pole. Further, acoustic sensors at the magnet ends and an acoustic calibration transducer are to be installed. Thus, we are to test sensitivity and precision of acoustic and quench antenna (QA) array sensors, both at close proximity to the coil, and we are to test and commission acoustic on-magnet real-time “calibration”. New or extended DAQ will be tested as well. In addition to diagnostic development, the purpose of the magnet experiment is to investigate current redistribution in the coil, both during quenching and in operating conditions; to assess voltage build up across strands and in the coil segments during quenching, to explore voltage signature differentiation between different type of quenches; to improve modeling of processes during quenching and for magnet design purposes. In this experiment, we expect to be able to characterize the processes during a quench in unprecedented details.

43 PARTICLE ACCELERATORS↗