165 records · Page 10

Results of Modeling and Simulation Support to Specia Nuclear Material Handling Facility Operations - 16053

Newport News Shipbuilding (NNS) is the sole designer and provider of nuclear powered aircraft carriers and one of only two companies in the United States to build nuclear powered submarines. As part of the upkeep of aircraft carriers, the ships return to NNS once in their lifetime for a complex overhaul and to be refueled. In support of overhaul operations NNS maintains a state of the art Special Nuclear Material (SNM) handling facility. Due to the complex nature of the operations that occur within this facility, during the design and initial operation of the building NNS developed a facility simulation model to provide decision support during the project planning and operational phases. This tool allows users to experiment with process times, process order, equipment utilization, personnel utilization and spatial utilization. By capturing the planned operations, time distributions for operations, equipment sizes and uses and personnel requirements, the tool accurately reflects the planned use of the facility. This realism allows the user to experiment with any aspect of the facility, in a controlled and cost effective space, and determine how changes or potential delays may impact overall facility operations. Thus the model allows for rapid exploration of multiple scenarios to determine likely outcomes, allowing a user to identify risks well ahead of their realization and explore mitigation strategies in a controlled space, to determine the ideal path forward. The tool was successful during the initial operation of the facility in helping to identify and mitigate risks related to the complex operations occurring during SNM handling. The tool is now in use to support planning for the next series of operations that will occur within the facility. The initial operations the model supported occurred during the deactivation of the USS Enterprise, and future operation will focus on the overhaul of Nimitz class aircraft carriers. The NNS planning team is currently using the tool to assess potential risks and challenges that are identified as potentially impacting the schedule and timelines for these overhaul processes. In addition, the NNS development team is working to add new operational steps to the model, capturing work that is occurring near the facility, but which directly impacts the facilities operational abilities. In conjuncture with the engineering planning division, the NNS development team has run over 20 complex scenarios through the tool. The team has provided output from these scenarios to both NNS personnel and government representatives. To date the model has successfully supported the identification of several feasible paths to incorporate new processes, dictated by the work to support a overhaul vs a deactivation. The model also provides a spatial arrangement component that allows users to experiment with different equipment placement within the facility. Due to the fidelity of the model, arranging equipment with the spatial component allows a user to set up the facility in an experimental layout and run the processes inside the facility to determine if the layout will be feasible, or if it would impact operational capabilities. Additionally, the spatial component allows for visual collaboration between stakeholders to ensure all operational personnel are aware of the current and planned layout, and that they do not locate equipment or work stations in locations that would interfere with facility operations. The spatial component, in combination with the simulation component, has resulted in several documented improvements in process. These include: the identification of additional equipment which could be stored outside the facility, without impacting operations, to increase space; confirmation of the ideal placement of a large water tank; and identification of several risks related to planned equipment storage area, allowing the team to develop new plans and avoid realizing the risk. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The effect of variable fuel staging transients on self-excited instabilities in a multiple-nozzle combustor

Combustion instability in gas turbine engines is often mitigated using fuel staging. Fuel staging, sometimes referred to as fuel splitting, is a strategy by which fuel is unevenly distributed between different nozzles of a multiple-nozzle combustor. These fuel splits are conducted in a transient manner in real engines, and the effects of these transients on instability are not well characterized. This work fills this gap by systematically studying the effects of transient fuel staging on self-excited combustion instability by varying the amount of staging fuel (staging amplitude), timescale in which the fuel is added (transient duration), and whether staging fuel is added or subtracted (transient direction). In this work, three staging amplitudes, five transient durations, and both transient directions are considered. The transient timescales are broadly divided into “short” duration transients, which have fuel delivery timescales shorter than the characteristic instability decay or onset timescales, and “long” duration transients, which have fuel delivery timescales longer than the characteristic instability decay or onset timescales. For short duration transients, we find the instability decay timescale depends on staging amplitude but does not depend on transient duration. For long duration transients, we find the instability decay timescale does not strongly depend on staging amplitude. The instability onset timescale is found to be longer and more variable between runs than the instability decay timescale for a given fuel delivery timescale. The onset timescale is also longer in duration and more variable than the decay timescale at a given fuel delivery timescale, implying that the instability rise process is overall more variable and slower than the instability decay process. Analysis of combustor damping rates show a strong dependence of damping rate on staging amplitude but no strong dependence on transient duration or direction. Instantaneous phase difference images between p' and are used to differentiate regions in the combustor that have constructive versus destructive interference between heat release rate oscillations and pressure fluctuations. Furthermore, the phase images show that p' and q . ' become in-phase early in the transient for the onset transients.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating the Lightning Strike Damage Tolerance for CFRP Composite Laminates Containing Conductive Nanofillers

Conductive nanofillers, such as carbon nanotube, graphene nanoplatelets, and carbon black particles (with diameters in nanometers) have been shown to enhance the electrical conductivity of fiber reinforced polymer matrix composites in many existing studies. The motivation is primarily for lightning strike protection, electromagnetic interference shielding, de-icing, and the manufacturing of lightweight electronic components. Here, we evaluate the lightning strike damage tolerance of carbon fiber reinforced polymer (CFRP) matrix composite laminates containing conductive nanofillers with varying weight fractions, including carbon black (CB), carbon nanotubes (CNT), and a mix of CB and CNT, through simulated lightning strike tests, followed by both non-destructive ultrasonic inspection and destructive sectioning to characterize the damage inflicted by the simulated lightning strike. Three-point flexural tests are performed to evaluate the residual strength retained by all CFRP specimens. Results show that lightning strike damage experienced varying levels of reduction for CFRP composite specimens containing conductive fillers in comparison to the baseline specimen without fillers. Notably, the delamination only penetrated to the interface between the 1st and 2nd layer for the specimen with 0.25 wt.% CNT in comparison to the baseline CFRP specimen for which the delamination penetrated to the interface between the 5th and 6th layer. Moreover, the retention of the flexural modulus increased from 26.5% to a maximum of 95.0% for the specimen with 0.25 wt.% hybrid CB and CNT. Yet, we show that using our chosen conductive fillers cannot fully eliminate lightning strike damage. Additionally, adding conductive fillers could compromise the flexural properties. We provide discussions on future recommendations on using conductive fillers for the lightning strike protection of CFRP composites.

36 MATERIALS SCIENCE↗