Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inventory generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Aboveground Biomass Estimation Using NISAR Simulated ALOS-2 Time Series Data

Aboveground biomass (AGB) is a critical parameter to better understand the global carbon cycle and to develop sustainable forest management. However, a large uncertainty prevails. L-band SAR data have demonstrated strong potential to accurately retrieve AGB over low-biomass regions (<100 Mg ha-1). The upcoming NASA-ISRO Synthetic Aperture Radar mission will collect data at L- and S-band over earth’s landmass with a repeat period of 12 days, allowing us to have ample data for monitoring biomass and its dynamics. One of the key science requirements of the mission is to produce annual AGB maps at 1-ha resolution with RMS accuracy of 20 Mg/ha for 80 percentage of area over low-biomass regions in Calibration/Validation sites. The NISAR biomass algorithm will generate AGB maps based on the parameterization of semi-empirical model along with NISAR time-series dual pol data (HH and HV). To calibrate and validate the model for mission requirements, the mission will use reference estimates of AGB produced from ground inventory plots and airborne LiDAR data collected over selected sites distributed across different global ecoregions. This paper presents the initial results of the calibration/validation of the NISAR AGB retrieval algorithm over the Lenoir Landing (LENO), Alabama, USA site using NISAR simulated ALOS-2 time series data. Five multi-temporal dual-pol HH and HV NISAR Simulated ALOS 2 data collections were used as input to assess the performance of the model. The model AGB retrieval results shows that the NISAR model was able to achieve RMS accuracy within 20 Mg/ha.

Ramachandran, Naveen [Jet Propulsion Laboratory, C↗

Salt Tank Testbed: a Test Site Designed to Replicate Floor Buckles Observed in Commercial TES Tanks

A test site has been designed and is under construction to replicate the buckling failure ob-served in several in-service storage tanks for nitrate salts operating up to 565°C. In commercial tanks multiple factors have been identified that influence the floors susceptibility to buck-ling, including: the as-manufactured shape of the floor, high compressive stresses due to thermal gradients and/or friction, fluid inventory and absolute temperature. Based on exten-sive modeling analysis it was determined that similar buckles can be reproduced in a scaled test tank (approximately 9x smaller than a representative commercial tank design). To buckle the scaled tank a radial thermal gradient is generated in the tank with a low fluid level, the fluid level is then increased while maintaining the thermal gradient; based on the modeling results just one of these cycles can plastically deform the tank floor. The test site which is under construction is designed to replicate this damaging cycle at lower temperatures. The goal of testing will be to reproduce this damaging cycle and buckle the scaled test tank floor, allowing proper model validation and a methodology for comparing different tank designs at a smaller (and less costly) scale.

25 ENERGY STORAGE↗

Pumped Thermal Energy Storage With Liquid Storage

Pumped Thermal Energy Storage (PTES) uses electricity to power a heat pump; transferring heat from a cold space to a hot space forms a hot and a cold thermal reservoir, thereby storing energy. To discharge, the temperature difference between the two stores is used to drive a heat engine which generates electricity. In this chapter, PTES systems which store energy in liquids will be described. The chapter will concentrate on Joule-Brayton power cycles with molten salt storage. Part-load operation of Joule-Brayton PTES with liquid storage can be managed with "inventory control," and it is demonstrated that this control method leads to relatively good performance over a range of operating points.

Carnot batteries↗

Long-life LiNi 0.5 Mn 1.5 O 4 /graphite lithium-ion cells with an artificial graphite-electrolyte interface

The high operating voltage of a spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) cathode leads to electrolyte decomposition and accelerated deterioration of the electrode/electrolyte interface in lithium-ion cells. Aggressive side reactions prevent long-term cycling and hinder its practical application. Advanced characterization shows that the high-voltage operation makes the graphite anode react with the electrolyte, particularly with the lithium salt in the electrolyte, resulting in massive active lithium inventory loss and capacity fade. The side reactions at the graphite are identified as the main culprit for the LNMO/graphite full cell decay. Here, we demonstrate that an artificial solid-electrolyte interface layer consisting of an ultra-thin Al 2 O 3 film, generated via atomic layer deposition (ALD) at the graphite surface, can successfully isolate the graphite from the electrolyte and inhibit the undesired reactions. Consequently, the capacity and cycling stability of the LNMO/graphite cell are drastically improved. After 300 cycles, the capacity retention of LNMO/graphite cell increases from 57.7% to 98.6% with the ALD-coated graphite. Furthermore, our findings provide valuable insights into the LNMO/graphite cell degradation and suggest a simple and robust, yet highly effective, approach for the practical viability of high-voltage lithium-ion batteries.

25 ENERGY STORAGE↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Aggregation bias and its drivers in large‐scale flood loss estimation: A Massachusetts case study

Abstract Large‐scale estimations of flood losses are often based on spatially aggregated inputs. This makes risk assessments vulnerable to aggregation bias, a well‐studied, sometimes substantial outcome in analyses that model fine‐grained spatial phenomena at coarse spatial units. To evaluate this potential in the context of large‐scale flood risk assessments, we use data from a high‐resolution flood hazard model and structure inventory for over 1.3 million properties in Massachusetts and examine how prominent data aggregation approaches affect the magnitude and spatial distribution of flood loss estimates. All considered aggregation approaches rely on aggregate structure inventories but differ in whether flood hazard is also aggregated. We find that aggregating only structure inventories slightly underestimates overall losses (−10% bias), and when flood hazard data is spatially aggregated to even relatively small spatial units (census block), statewide aggregation bias can reach +366%. All aggregation‐based procedures fail to capture the spatial covariation of inputs distributions in the upper tails that disproportionately generate total expected losses. Our findings are robust to several key assumptions, add important context to published risk assessments and highlight opportunities to improve flood loss estimation uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Exploration of oxidative chemistry and secondary organic aerosol formation in the Amazon during the wet season: explicit modeling of the Manaus urban plume with GECKO-A

The GoAmazon 2014/5 field campaign took place in Manaus, Brazil, and allowed the investigation of the interaction between background-level biogenic air masses and anthropogenic plumes. We present in this work a box model built to simulate the impact of urban chemistry on biogenic secondary organic aerosol (SOA) formation and composition. An organic chemistry mechanism is generated with the Generator for Explicit Chemistry and Kinetics of Organics in the Atmosphere (GECKO-A) to simulate the explicit oxidation of biogenic and anthropogenic compounds. A parameterization is also included to account for the reactive uptake of isoprene oxidation products on aqueous particles. The biogenic emissions estimated from existing emission inventories had to be reduced to match measurements. The model is able to reproduce ozone and NO x for clean and polluted situations. The explicit model is able to reproduce background case SOA mass concentrations but does not capture the enhancement observed in the urban plume. The oxidation of biogenic compounds is the major contributor to SOA mass. A volatility basis set (VBS) parameterization applied to the same cases obtains better results than GECKO-A for predicting SOA mass in the box model. The explicit mechanism may be missing SOA-formation processes related to the oxidation of monoterpenes that could be implicitly accounted for in the VBS parameterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NREL Stratus - Enabling Workflows to Fuse Data Streams, Modeling, Simulation, and Machine Learning

Integrating cloud services into advanced computing facilities provides significant new capabilities over focusing solely on traditional high performance computing (HPC) workloads. This brings complementary capabilities as well as enabling new focused roles for HPC. They are especially potent for workflows that fuse data streams, modeling and simulation ('modsim') and machine learning. A key challenge to adopting a hybrid edge-cloud-HPC model is to align optimal capability, data, and user intent on the right resources for each step in a workflow.?The NREL Stratus service provides a basis for this: Stratus layers capabilities needed to make?cloud services accessible to a lab-based scientific community on commercial offerings, and; currently supports upwards of 200 projects ranging from IOT integration to traditional modeling and simulation. This provides a real-world inventory of scientific workflow elements. A growing knowledge base enables placing these elements appropriately between the edge, cloud, and traditional HPC. This paper outlines a vision via reference architecture and the application of that architecture in a typical workflow highlighting multiple components: sensor data intake, cleaning and transforming (edge/cloud suitable); generation of synthetic data through modsim, computationally heavy ML training and hyperparameter optimization (HPC suitable), and; inference and deployment (cloud ideal). Every step in such a workflow involves a cost-benefit analysis regarding the data movement, computational efficiency, availability, latency, and resource capabilities. The reference architecture and examples outlined allow for understanding new opportunities in the context of emerging workflows that combine IOT, cloud, and HPC to bolster scientific productivity.

AI↗

28 NREL Stratus - Enabling Workflows to Fuse Data Streams, Modeling, Simulation, and Machine Learning: Preprint

Integrating cloud services into advanced computing facilities provides significant new capabilities over focusing solely on traditional high performance computing (HPC) workloads. This brings complementary capabilities as well as enabling new focused roles for HPC. They are especially potent for workflows that fuse data streams, modeling and simulation ('modsim') and machine learning. A key challenge to adopting a hybrid edge-cloud-HPC model is to align optimal capability, data, and user intent on the right resources for each step in a workflow.?The NREL Stratus service provides a basis for this: Stratus layers capabilities needed to make?cloud services accessible to a lab-based scientific community on commercial offerings, and; currently supports upwards of 200 projects ranging from IOT integration to traditional modeling and simulation. This provides a real-world inventory of scientific workflow elements. A growing knowledge base enables placing these elements appropriately between the edge, cloud, and traditional HPC. This paper outlines a vision via reference architecture and the application of that architecture in a typical workflow highlighting multiple components: sensor data intake, cleaning and transforming (edge/cloud suitable); generation of synthetic data through modsim, computationally heavy ML training and hyperparameter optimization (HPC suitable), and; inference and deployment (cloud ideal). Every step in such a workflow involves a cost-benefit analysis regarding the data movement, computational efficiency, availability, latency, and resource capabilities. The reference architecture and examples outlined allow for understanding new opportunities in the context of emerging workflows that combine IOT, cloud, and HPC to bolster scientific productivity.

AI↗

Hydropower Resilience Database for Assessing Microgrid Formation Capability and Enhancing Power Grid Resilience

In the face of increasing frequency of extreme events, enhancing resilience and reliability of energy infrastructure demands innovative solutions. Hydropower, with its inherent generation flexibility and grid-forming capability, offers significant potential for enhancing power grid resilience through the establishment of microgrids. To enable informed decision-making and strategic planning, we present the Hydropower Resilience Database (HRD) that integrates data from various sources such as Oakridge National Laboratory (ORNL) HydroSource, National Inventory of Dams, and US Western Grid database. By integrating relevant information on hydropower plant characteristics, including dams, reservoirs, and connected electrical grid, this resource enables hydropower plant owners, utilities, and community stakeholders to identify and evaluate the feasibility of using hydropower resources in microgrids to support nearby communities and critical infrastructure in various challenging scenarios. Using HRD, a set of metrics are evaluated to quantify the capability of hydropower plants to support essential microgrid functions. An interactive tool is developed using ArcGIS, enabling the visualization and analysis using HRD. Our research contributes to strategic planning efforts for fortifying energy infrastructure, ensuring reliable power supply during disruptions, and advancing the development of robust and resilient energy systems in regions susceptible to grid vulnerabilities.

13 HYDRO ENERGY↗

Hydropower Resilience Database for Assessing Microgrid Formation Capability and Enhancing Power Grid Resilience

In the face of increasing frequency of extreme events, enhancing resilience and reliability of energy infrastructure demands innovative solutions. Hydropower, with its inherent generation flexibility and grid-forming capability, offers significant potential for enhancing power grid resilience through the establishment of microgrids. To enable informed decision-making and strategic planning, we present the Hydropower Resilience Database (HRD) that integrates data from various sources such as Oakridge National Laboratory (ORNL) HydroSource, National Inventory of Dams, and US Western Grid database. By integrating relevant information on hydropower plant characteristics, including dams, reservoirs, and connected electrical grid, this resource enables hydropower plant owners, utilities, and community stakeholders to identify and evaluate the feasibility of using hydropower resources in microgrids to support nearby communities and critical infrastructure in various challenging scenarios. Using HRD, a set of metrics are evaluated to quantify the capability of hydropower plants to support essential microgrid functions. An interactive tool is developed using ArcGIS, enabling the visualization and analysis using HRD. Our research contributes to strategic planning efforts for fortifying energy infrastructure, ensuring reliable power supply during disruptions, and advancing the development of robust and resilient energy systems in regions susceptible to grid vulnerabilities.

13 HYDRO ENERGY↗

Radial Deconsolidation Leach-Burn-Leach of Five AGR-3/4 TRISO Fuel Compacts after Post-Irradiation Heating Tests

Five AGR-3/4 fuel compacts were previously heated in the Fuel Accident Condition Simulator (FACS) furnace. Three of these compacts were also reirradiated in the Neutron Radiography (NRAD) reactor before the FACS tests. One of these was heated to 1200°C, two were heated to 1400°C, one was heated to 1600°C, and one was held for a period of time at 1600 and 1700°C. After these FACS tests, the compacts were subjected to destructive post-irradiation examination (PIE) via radial-deconsolidation-leach-burn-leach (RDLBL) at INL. The RDLBL process deconsolidated the compacts in multiple radial steps, followed by a final, single-step axial deconsolidation. The samples generated at each step were analyzed for isotopes of key fission products and actinides. After each deconsolidation step, the compact volume was assessed, and this was used to normalize the measured quantities of nuclides of interest to give volumetric concentrations as a function of radial position within the compact. The total inventories of measured fission products and actinides and the radial concentration profiles were compared with their sibling compacts within the same capsule (similar irradiation conditions) that went through RDLBL in the as-irradiated state. These data will be used to refine the fission product transport models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radial Deconsolidation and Leach-Burn-Leach of Eight As-Irradiated AGR-3/4 TRISO Fuel Compacts

Eight as-irradiated AGR-3/4 fuel compacts were subjected to destructive post-irradiation examination via radial-deconsolidation-leach-burn-leach (RDLBL) at INL. The RDLBL process deconsolidated the compacts in multiple, radial steps, followed by a final, single-step axial deconsolidation. The samples generated at each step were analyzed for isotopes of key fission products and actinides. After each deconsolidation step, the compact volume was assessed, and this was used to normalize the measured quantity of nuclides of interest to give a volumetric concentration as a function of radial position within the compact. The total inventories of measured fission products and actinides and the radial concentration profiles were compared among the eight compacts deconsolidated at INL and four other as-irradiated compacts examined at ORNL. The results were analyzed for the effects of irradiation temperature. These results will be used for comparisons with fission product transport models and as input from which fission product diffusivities can be calculated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative life cycle assessment of woody biomass processing: air classification, drying, and size reduction powered by bioelectricity versus grid electricity

Sulfur accumulation during biofuel production is pollutive and toxic to conversion catalysts and causes the premature breakdown of processing equipment. Air classification is an effective preprocessing technology for ash and sulfur reduction from biomass feedstocks. Here, a life cycle assessment (LCA) sought to understand the environmental impact of implementing air classification as a sulfur-mitigation technique to improve feedstock quality for pine residues using a grid electricity scenario (GES) versus a bioelectricity scenario (BES). Global warming potential (GWP) for preprocessing was simulated using inventory databases embedded in SimaPro and the Argonne National Laboratory’s GREET model, specifically focusing on comparing the GWP of a GES versus a BES. Overall, the GES had a GWP impact over seven times that of the BES (136 versus 18 kg CO 2 equivalent per tonne of usable feedstock), with steam generation during rotary drying accounting for 57% of the GES’s GWP. Air classification represents 0.4% and 1.6% of the total GWP impact for the GES and BES, respectively. Therefore, air classification can facilitate a 30% reduction in feedstock sulfur content to improve feedstock quality for biofuel conversion and lessen corrosion of equipment while contributing minimal GWP impact during preprocessing.

Air classification↗

Temperature sensitivity of the equilibrium neutronics and accident analysis of the HTR-10

Pebble-Bed High-Temperature Gas-cooled Reactors (PB-HTGR) are moderated by the graphite in the fuel pebbles and the graphite reflector surrounding the pebble-bed. Because graphite is by far the most abundant material in PB-HTGRs and the primary moderator, accurate modeling of the graphite material, including density, impurities, and temperatures, is crucial for accurate computational modeling and simulation of these reactors. While main characteristics of the graphite components are often known, the local temperature is less well known and often averaged over all components. Here, this work studies the impact of considering accurate temperature profiles in the graphite material on the generation of a small PB-HTGR model at the state of equilibrium operation and on short-term accident progression. The fuel compositions for the PB-HTGR were determined using a jump-in equilibrium modeling method, the Axial Radial Zone Equilibrium Modeling (AR-ZEM) method. In contrast to previous work, the AR-ZEM method was used considering thermal-hydraulic feedback from the MELCOR code to determine temperatures of the fuel pebbles and the surrounding graphite reflector. The consideration of an axial and radial temperature profile in the core and reflector, as opposed to uniform material temperatures, had an impact of almost 1,300 pcm on the equilibrium core eigenvalue and caused significant differences in the discharged plutonium fuel inventory with up to 4.9% and 11.0% for Pu-239 and Pu-242, respectively. To assess the impact on short-term accident progression, two Anticipated Transient Without SCRAM (ATWS) events, a Pressurized Loss of Forced Coolant (PLOFC) and a Control Rod Withdrawal (CRW) with loss of flow, were simulated with MELCOR. The use of temperature profiles in the equilibrium core models did not reveal a significant impact on the temperature, power, or reactivity responses during the transients. In conclusion, a need for consideration of accurate temperature profiles, in particular for the graphite reflector, was found for the generation of equilibrium PB-HTGRs core models using jump-in methods, but detailed temperature profiles may not be necessary when performing conservative transient analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 °C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30°, 45° and 60°) leads to significant temperature differences in the floor, between 57 °C and 62 °C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 °C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.

14 SOLAR ENERGY↗