Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SFRC Measurement Control Summary - FY23 Q3/Q4

Measurements with the Spent Fuel Rod Counter (SFRC) to be performed bi annually include 3 He detector efficiency checks (in both modules) and ion chamber channel tests with a pocket pulser. These measurements will all be performed at TA-35, building 27 where the SFRC is stored. Refer to LA-UR-22-31737 and LA-CP-22-20079 SFRC measurement control documents for a description of additional tests. Note that during this measurement period, counts could not be confirmed for the Si detectors, as an analog pulse to TTL box necessary for the DAQs to communicate with the detectors was still under construction. For this reason, typical measurements at the Calibrated Dose Facility were not performed for the second half of FY23. When these components are finished by the NEN electrical shop, the Si detectors will be implemented into these measurement control checks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Deblurring for nuclei: 3D characteristics of heavy-ion collisions

Observables from nuclear and high-energy experiments can be degraded by detector performance and/or methodology in extracting the observables, such as of the final-state characteristics of heavy-ion collisions in relation to a coarsely estimated reaction-plane direction. We propose the use of deblurring methods, such as in optics, to correct for observable degradation. Our main focus is the restoration of triple-differential particle distributions in heavy-ion collisions. We demonstrate that these could be extracted from collision measurements following the Richardson-Lucy deblurring method from optics. We illustrate basic features of the restoration methodology in a schematic model assuming either ideal or more realistic particle detection. Here, the inferred three-dimensional (3D) distributions for collisions may be easier to interpret in terms of collision dynamics and sought properties of bulk matter than the currently employed Fourier coefficients, that combine information from different azimuthal angles relative to the reaction plane.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors

Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The potential of a TeV-scale muon-ion collider

We propose the development of a novel muon-proton and muon-nucleus collider facility at the TeV scale that is capable of performing precision deep inelastic scattering measurements in new regimes and providing a rich program in nuclear and particle physics. Such a facility could seed, or leverage, the development of a muon-antimuon collider and make use of the existing hadron accelerator infrastructure when sited at a facility such as Brookhaven National Laboratory, Fermilab, or CERN. Here, we discuss the possible energy and luminosity design parameters for several collider configurations, and illustrate the science potential with several studies on deep inelastic scattering kinematics, Higgs and vector boson production, top quark production, and beyond Standard Model leptoquark production. Detector design considerations and a possible road map toward development are also given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Early Career Award: Single Molecule Fluorescence Imaging for a Background-Free Neutrinoless Double Beta Decay Search

This project aimed to develop a suite of novel technologies targeted at detecting individual barium ions produced in neutrinoless double beta decays of 136 Xe, as part of the NEXT program of gaseous xenon detectors. We realized novel molecules which could sense Ba 2+ ions in dry conditions; new microscopy techniques operable in dry noble gases, including the required operating conditions of xenon at 10 bar pressure; and new radiofrequency ion transport methods (developed both theoretically and experimentally) that can transport ions in dense xenon gas. Together, these developments represent a major advance toward a background-free neutrinoless double beta decay experiment based on single molecule fluorescence imaging of Ba 2+ daughter ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

ALICE upgrades during the LHC Long Shutdown 2

A Large Ion Collider Experiment (ALICE) has been conceived and constructed as a heavy-ion experiment at the LHC. During LHC Runs 1 and 2, it has produced a wide range of physics results using all collision systems available at the LHC. In order to best exploit new physics opportunities opening up with the upgraded LHC and new detector technologies, the experiment has undergone a major upgrade during the LHC Long Shutdown 2 (2019–2022). This comprises the move to continuous readout, the complete overhaul of core detectors, as well as a new online event processing farm with a redesigned online-offline software framework. These improvements will allow to record Pb-Pb collisions at rates up to 50 kHz, while ensuring sensitivity for signals without a triggerable signature.

47 OTHER INSTRUMENTATION↗

The optimal use of segmentation for sampling calorimeters

One of the key design choices of any sampling calorimeter is how fine to make the longitudinal and transverse segmentation. Here, to inform this choice, we study the impact of calorimeter segmentation on energy reconstruction. To ensure that the trends are due entirely to hardware and not to a sub-optimal use of segmentation, we deploy deep neural networks to perform the reconstruction. These networks make use of all available information by representing the calorimeter as a point cloud. To demonstrate our approach, we simulate a detector similar to the forward calorimeter system intended for use in the ePIC detector, which will operate at the upcoming Electron Ion Collider. We find that for the energy estimation of isolated charged pion showers, relatively fine longitudinal segmentation is key to achieving an energy resolution that is better than 10% across the full phase space. These results provide a valuable benchmark for ongoing EIC detector optimizations and may also inform future studies involving high-granularity calorimeters in other experiments at various facilities.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space charge effects in the SπRIT time projection chamber

Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable appropriate for fixed target experiments to study the effects. Finally, we will present an algorithm for correcting the space charge and discuss some of the implications it has on the momentum determination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoproduction of K + K − Pairs in Ultraperipheral Collisions

K + K − pairs may be produced in photonuclear collisions, either from the decays of photoproduced ϕ ( 1020 ) mesons or directly as nonresonant K + K − pairs. Measurements of K + K − photoproduction probe the couplings between the ϕ ( 1020 ) and charged kaons with photons and nuclear targets. The kaon-proton scattering occurs at energies far above those available elsewhere. We present the first measurement of coherent photoproduction of K + K − pairs on lead ions in ultraperipheral collisions using the ALICE detector, including the first investigation of direct K + K − production. There is significant K + K − production at low transverse momentum, consistent with coherent photoproduction on lead targets. In the mass range 1.1 < M K K < 1.4 GeV / c 2 above the ϕ ( 1020 ) resonance, for rapidity | y K K | < 0.8 and p T , K K < 0.1 GeV / c , the measured coherent photoproduction cross section is d σ / d y = 3.37 ± 0.61 ( stat ) ± 0.15 ( syst ) mb . The center-of-mass energy per nucleon of the photon-nucleus (Pb) system W γ Pb , n ranges from 33 to 188 GeV, far higher than previous measurements on heavy-nucleus targets. The cross section is larger than expected for ϕ ( 1020 ) photoproduction alone. The mass spectrum is fit to a cocktail consisting of ϕ ( 1020 ) decays, direct K + K − photoproduction, and interference between the two. The confidence regions for the amplitude and relative phase angle for direct K + K − photoproduction are presented. © 2024 CERN, for the ALICE Collaboration 2024 CERN

43 PARTICLE ACCELERATORS↗

Robust Independent Validation of Experiment and Theory: Rivet version 3

First released in 2010, the Rivet library forms an important repository for analysis code, facilitating comparisons between measurements of the final state in particle collisions and theoretical calculations of those final states. We give an overview of Rivet's current design and implementation, its uptake for analysis preservation and physics results, and summarise recent developments including propagation of MC systematic-uncertainty weights, heavy-ion and ep physics, and systems for detector emulation. In addition, we provide a short user guide that supplements and updates the Rivet user manual.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗